1.
Med Phys ; 51(2): 1061-1073, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38103261

RESUMO

BACKGROUND: Many healthcare institutions have guidelines concerning the usage of protective procedures, and various x-ray shields have been used to reduce unwanted radiation exposure to medical staff and patients when using x-rays. Most x-ray shields are in the form of sheets and lack elasticity, which limits their effectiveness in shielding areas with movement, such as the thyroid. To overcome this limitation, we have developed an innovative elastic x-ray shield. PURPOSE: The purpose of this study is to explain the methodology for developing and evaluating a novel elastic x-ray shield with sufficient x-ray shielding ability. Furthermore, valuable knowledge and evaluation indices are derived to assess our shield's performance. METHODS: Our x-ray shield was developed through a process of embedding Bi2 O3 particles into porous polyurethane. Porous polyurethane with a thickness of 10 mm was dipped into a solution of water, metal particles, and chemical agents. Then, it was air-dried to fix the metal particles in the porous polyurethane. Thirteen investigational x-ray shields were fabricated, in which Bi2 O3 particles at various mass thicknesses (ranging from 585 to 2493 g/m2 ) were embedded. To determine the performance of the shielding material, three criteria were evaluated: (1) Dose Reduction Factor ( D R F $DRF$ ), measured using inverse broad beam geometry; (2) uniformity, evaluated from the standard deviation ( S D $SD$ ) of the x-ray image obtained using a clinical x-ray imaging detector; and (3) elasticity, evaluated by a compression test. RESULTS: The elastic shield with small pores, containing 1200 g/m2 of the metal element (Bi), exhibited a well-balanced performance. The D R F $DRF$ was approximately 80% for 70 kV diagnostic x-rays. This shield's elasticity was -0.62 N/mm, a loss of only 30% when compared to porous polyurethane without metal. Although the non-uniformity of the x-ray shield leads to poor shielding ability, it was found that the decrease in the shielding ability can be limited to a maximum of 6% when the shield is manufactured so that the S D $SD$ of the x-ray image of the shield is less than 10%. CONCLUSIONS: It was verified that an elastic x-ray shield that offers an appropriate reduction in radiation exposure can be produced by embedding Bi2 O3 particles into porous polyurethane. Our findings can lead to the development of novel x-ray shielding products that can reduce the physical and mental stress on users.


Assuntos
Poliuretanos , Tomografia Computadorizada por Raios X , Humanos , Raios X , Porosidade , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
2.
Med Phys ; 48(8): 4621-4635, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33760234

RESUMO

PURPOSE: We aimed to develop a disposable rectum dosimeter and to demonstrate its ability to measure exposure dose to the rectum during brachytherapy for cervical cancer treatment using high-dose rate 192 Ir. Our rectum dosimeter measures the dose with an optically stimulated luminescence (OSL) sheet which was furled to a catheter. The catheter we used is 6 mm in diameter; therefore, it is much less invasive than other rectum dosimeters. The rectum dosimeter developed in this study has the characteristics of being inexpensive and disposable. It is also an easy-to-use detector that can be individually sterilized, making it suitable for clinical use. METHODS: To obtain a dose calibration curve, phantom experiments were performed. Irradiation was performed using a cubical acrylic phantom, and the response of the OSL dosimeter was calibrated with the calculation value predicted by the treatment planning system (TPS). Additionally, the dependence of catheter angle on the dosimeter position and repeatability were evaluated. We also measured the absorbed dose to the rectum of patients who were undergoing brachytherapy for cervical cancer (n = 64). The doses measured with our dosimeters were compared with the doses calculated by the TPS. In order to examine the causes of large differences between measured and planned doses, we classified the data into common and specific cases when performing this clinical study. For specific cases, the following three categories were considered: (a) patient movement, (b) gas in the vagina and/or rectum, and (c) artifacts in the X-ray image caused by applicators. RESULTS: A dose calibration curve was obtained in the range of 0.1 Gy-10.0 Gy. From the evaluation of the dependence of catheter angle on the dosimeter position and repeatability, we determined that our dosimeter can measure rectum dose with an accuracy of 3.1% (k = 1). In this clinical study, we succeeded in measuring actual doses using our rectum dosimeter. We found that the deviation of the measured dose from the planned dose was derived to be 12.7% (k = 1); this result shows that the clinical study included large elements of uncertainty. The discrepancies were found to be due to patient motion during treatment, applicator movement after planning images were taken, and artifacts in the planning images. CONCLUSIONS: We present the idea that a minimally invasive rectum dosimeter can be fabricated using an OSL sheet. Our clinical study demonstrates that a rectum dosimeter made from an OSL sheet has sufficient ability to evaluate rectum dose. Using this dosimeter, valuable information concerning organs at risk can be obtained during brachytherapy.


Assuntos
Braquiterapia , Dosímetros de Radiação , Feminino , Humanos , Luminescência , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reto
3.
Appl Radiat Isot ; 170: 109617, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33592487

RESUMO

In this study, we propose an effective atomic number (Zeff) determination method based on a photon-counting technique. The proposed method can correct for the beam hardening effect and detector response based on polychromatic X-rays to allow high accuracy material identification. To demonstrate the effectiveness of our method, the procedure was applied to X-ray images acquired by a prototype energy-resolving photon-counting detector and we obtained an Zeff image with accuracy of Zeff ± 0.5 regardless of the mass thickness.