Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
AJNR Am J Neuroradiol ; 42(3): 487-492, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33446501

RESUMO

BACKGROUND AND PURPOSE: Transradial access for neurointerventional procedures has been proved a safer and more comfortable alternative to femoral artery access. We present our experience with transradial (distal radial/anatomic snuffbox and radial artery) access for treatment of intracranial aneurysms using all 3 FDA-approved flow diverters. MATERIALS AND METHODS: This was a high-volume, dual-center, retrospective analysis of each institution's data base between June 2018 and June 2020 and a collection of all patients treated with flow diversion via transradial access. Patient demographic information and procedural and radiographic data were obtained. RESULTS: Seventy-four patients were identified (64 female patients) with a mean age of 57.5 years with a total of 86 aneurysms. Most aneurysms were located in the anterior circulation (93%) and within the intracranial ICA (67.4%). The mean aneurysm size was 5.5 mm. Flow diverters placed included the Pipeline Embolization Device (Flex) (PED, n = 65), the Surpass Streamline Flow Diverter (n = 8), and the Flow-Redirection Endoluminal Device (FRED, n = 1). Transradial access was successful in all cases, but femoral crossover was required in 3 cases (4.1%) due to tortuous anatomy and inadequate support of the catheters in 2 cases and an inability to navigate to the target vessel in a patient with an aberrant right subclavian artery. All 71 other interventions were successfully performed via the transradial approach (95.9%). No access site complications were encountered. Asymptomatic radial artery occlusion was encountered in 1 case (3.7%). CONCLUSIONS: Flow diverters can be successfully placed via the transradial approach with high technical success, low access site complications, and a low femoral crossover rate.


Assuntos
Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/terapia , Artéria Radial/cirurgia , Idoso , Prótese Vascular , Catéteres , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
2.
Int J Stroke ; 15(5): 467-476, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31679478

RESUMO

The recent advent of endovascular procedures has created the unique opportunity to collect and analyze thrombi removed from cerebral arteries, instigating a novel subfield in stroke research. Insights into thrombus characteristics and composition could play an important role in ongoing efforts to improve acute ischemic stroke therapy. An increasing number of centers are collecting stroke thrombi. This paper aims at providing guiding information on thrombus handling, procedures, and analysis in order to facilitate and standardize this emerging research field.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Trombose , Isquemia Encefálica/complicações , Isquemia Encefálica/cirurgia , Humanos , Acidente Vascular Cerebral/cirurgia , Trombectomia
3.
AJNR Am J Neuroradiol ; 38(3): 442-449, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28104643

RESUMO

BACKGROUND AND PURPOSE: Advancements in medical device and imaging technology as well as accruing clinical evidence have accelerated the growth of the endovascular treatment of cerebrovascular diseases. However, the augmented role of these procedures raises concerns about the radiation dose to patients and operators. We evaluated patient doses from an x-ray imaging platform with radiation dose-reduction technology, which combined image noise reduction, motion correction, and contrast-dependent temporal averaging with optimized x-ray exposure settings. MATERIALS AND METHODS: In this single-center, retrospective study, cumulative dose-area product inclusive of fluoroscopy, angiography, and 3D acquisitions for all neurovascular procedures performed during a 2-year period on the dose-reduction platform were compared with a reference platform. Key study features were the following: The neurointerventional radiologist could select the targeted dose reduction for each patient with the dose-reduction platform, and the statistical analyses included patient characteristics and the neurointerventional radiologist as covariates. The analyzed outcome measures were cumulative dose (kerma)-area product, fluoroscopy duration, and administered contrast volume. RESULTS: A total of 1238 neurointerventional cases were included, of which 914 and 324 were performed on the reference and dose-reduction platforms, respectively. Over all diagnostic and neurointerventional procedures, the cumulative dose-area product was significantly reduced by 53.2% (mean reduction, 160.3 Gy × cm2; P < .0001), fluoroscopy duration was marginally significantly increased (mean increase, 5.2 minutes; P = .0491), and contrast volume was nonsignificantly increased (mean increase, 15.3 mL; P = .1616) with the dose-reduction platform. CONCLUSIONS: A significant reduction in patient radiation dose is achievable during neurovascular procedures by using dose-reduction technology with a minimal impact on workflow.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Transtornos Cerebrovasculares/cirurgia , Procedimentos Endovasculares/métodos , Radiografia Intervencionista/métodos , Idoso , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação , Estudos Retrospectivos , Raios X
4.
AJNR Am J Neuroradiol ; 38(1): 97-104, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28059705

RESUMO

BACKGROUND AND PURPOSE: Although most cervical dissections are managed medically, emergent endovascular treatment may become necessary in the presence of intracranial large-vessel occlusions, flow-limiting and long-segment dissections with impending occlusion, and/or hypoperfusion-related ischemia at risk of infarction. We investigated the role of emergent endovascular stenting of long-segment carotid dissections in the acute ischemic stroke setting. MATERIALS AND METHODS: We retrospectively studied long-segment carotid dissections requiring stent reconstruction with multiple tandem stents (≥3 stents) and presenting with acute (<12 hours) ischemic stroke symptoms (NIHSS score, ≥4). We analyzed patient demographics, vascular risk factors, clinical presentations, imaging/angiographic findings, technical procedures/complications, and clinical outcomes. RESULTS: Fifteen patients (mean age, 51.5 years) with acute ischemic stroke (mean NIHSS score, 15) underwent endovascular stent reconstruction for vessel and/or ischemic tissue salvage. All carotid dissections presented with >70% flow limiting stenosis and involved the distal cervical ICA with a minimum length of 3.5 cm. Carotid stent reconstruction was successful in all patients with no residual stenosis or flow limitation. Nine patients (60%) harbored intracranial occlusions, and 6 patients (40%) required intra-arterial thrombolysis/thrombectomy, achieving 100% TICI 2b-3 reperfusion. Two procedural complications were limited to thromboembolic infarcts from in-stent thrombus and asymptomatic hemorrhagic infarct transformation (7% morbidity, 0% mortality). Angiographic and ultrasound follow-up confirmed normal carotid caliber and stent patency, with 2 cases of <20% in-stent stenosis. Early clinical improvement resulted in a mean discharge NIHSS score of 6, and 9/15 (60%) patients achieved a 90-day mRS of ≤2. CONCLUSIONS: Emergent stent reconstruction of long-segment and flow-limiting carotid dissections in acute ischemic stroke intervention is safe and effective, with favorable clinical outcomes, allowing successful thrombectomy, vessel salvage, restoration of cerebral perfusion, and/or prevention of recurrent thromboembolic stroke.


Assuntos
Dissecção Aórtica/cirurgia , Doenças das Artérias Carótidas/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Dissecção Aórtica/complicações , Doenças das Artérias Carótidas/complicações , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
5.
AJNR Am J Neuroradiol ; 38(3): 582-589, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28007769

RESUMO

BACKGROUND AND PURPOSE: Flow diverters for the treatment of posterior circulation aneurysms remain controversial. We aimed to identify factors contributing to outcome measures in patients treated with the Surpass flow diverter for aneurysms in this location. MATERIALS AND METHODS: We conducted an observational study of 53 patients who underwent flow-diverter treatment for posterior circulation aneurysms at 15 centers. Key outcome measures were mortality, complete aneurysm occlusion, and modified Rankin Scale score at follow-up. RESULTS: At follow-up (median, 11.3 months; interquartile range, 5.9-12.7 months), 9 patients had died, resulting in an all-cause mortality rate of 17.3% (95% CI, 7%-27.6%); 7 deaths (14%) were directly related to the procedure and none occurred in patients with a baseline mRS score of zero. After adjusting for covariates, a baseline mRS of 3-5 was more significantly (P = .003) associated with a higher hazard ratio for death than a baseline mRS of 0-2 (hazard ratio, 17.11; 95% CI, 2.69-109.02). After adjusting for follow-up duration, a 1-point increase in the baseline mRS was significantly (P < .001) associated with higher values of mRS at follow-up (odds ratio, 2.93; 95% CI, 1.79-4.79). Follow-up angiography in 44 patients (median, 11.3 months; interquartile range, 5.9-12.7 months) showed complete aneurysm occlusion in 29 (66%; 95% CI, 50.1%-79.5%). CONCLUSIONS: Clinical results of flow-diverter treatment of posterior circulation aneurysms depend very much on patient selection. In this study, poorer outcomes were related to the treatment of aneurysms in patients with higher baseline mRS scores. Angiographic results showed a high occlusion rate for this subset of complex aneurysms.


Assuntos
Prótese Vascular , Aneurisma Intracraniano/cirurgia , Artéria Cerebral Posterior/cirurgia , Adolescente , Adulto , Idoso , Implante de Prótese Vascular/mortalidade , Angiografia Cerebral , Embolização Terapêutica , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Posterior/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
6.
AJNR Am J Neuroradiol ; 36(1): 146-52, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25273534

RESUMO

BACKGROUND AND PURPOSE: Although myeloperoxidase activity in vivo can be visualized by using noninvasive imaging, successful clinical translation requires further optimization of the imaging approach. We report a motion-sensitized driven-equilibrium MR imaging approach for the detection of a myeloperoxidase activity-specific gadolinium-containing imaging agent in experimental aneurysm models, which compensates for irregular blood flow, enabling vascular wall imaging in the aneurysm. MATERIALS AND METHODS: A phantom was built from rotational angiography of a rabbit elastase aneurysm model and was connected to a cardiac pulse duplicator mimicking rabbit-specific flow conditions. A T1-weighted turbo spin-echo-based motion-sensitized driven-equilibrium pulse sequence was optimized in vitro, including the addition of fat suppression and the selection of the velocity-encoding gradient parameter. The optimized sequence was applied in vivo to rabbit aneurysm models with and without inflammation in the aneurysmal wall. Under each condition, the aneurysms were imaged before and after intravenous administration of the imaging agent. The signal-to-noise ratio of each MR imaging section through the aneurysm was calculated. RESULTS: The motion-sensitized driven-equilibrium sequence was optimized to reduce flow signal, enabling detection of the myeloperoxidase imaging agent in the phantom. The optimized imaging protocol in the rabbit model of saccular aneurysms revealed a significant increase in the change of SNR from pre- to post-contrast MR imaging in the inflamed aneurysms compared with naïve aneurysms and the adjacent carotid artery (P < .0001). CONCLUSIONS: A diagnostic MR imaging protocol was optimized for molecular imaging of a myeloperoxidase-specific molecular imaging agent in an animal model of inflamed brain aneurysms.


Assuntos
Aumento da Imagem/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Neuroimagem/métodos , Peroxidase , Animais , Modelos Animais de Doenças , Gadolínio DTPA , Masculino , Movimento (Física) , Imagens de Fantasmas , Coelhos , Radiografia , Razão Sinal-Ruído
7.
AJNR Am J Neuroradiol ; 36(1): 98-107, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25125666

RESUMO

BACKGROUND AND PURPOSE: Incomplete occlusion and recanalization of large and wide-neck brain aneurysms treated by endovascular therapy remains a challenge. We present preliminary clinical and angiographic results of an experimentally optimized Surpass flow diverter for treatment of intracranial aneurysms in a prospective, multicenter, nonrandomized, single-arm study. MATERIALS AND METHODS: At 24 centers, 165 patients with 190 intracranial aneurysms of the anterior and posterior circulations were enrolled. The primary efficacy end point was the percentage of intracranial aneurysms with 100% occlusion on 6-month DSA. The primary safety end point was neurologic death and any stroke through a minimum follow-up of 6 months. RESULTS: Successful flow-diverter delivery was achieved in 161 patients with 186 aneurysms (98%); the mean number of devices used per aneurysm was 1.05. Clinical follow-up (median, 6 months) of 150 patients (93.2%), showed that the primary safety end point occurred in 18 subjects. Permanent neurologic morbidity and mortality were 6% and 2.7%, respectively. Morbidity occurred in 4% and 7.4% of patients treated for aneurysms of the anterior and posterior circulation, respectively. Neurologic death during follow-up was observed in 1.6% and 7.4% of patients with treated intracranial aneurysms of the anterior and posterior circulation, respectively. Ischemic stroke at ≤30 days, SAH at ≤7 days, and intraparenchymal hemorrhage at ≤7 days were encountered in 3.7%, 2.5%, and 2.5% of subjects, respectively. No disabling ischemic strokes at >30 days or SAH at >7 days occurred. New or worsening cranial nerve deficit was observed in 2.7%. Follow-up angiography available in 158 (86.8%) intracranial aneurysms showed 100% occlusion in 75%. CONCLUSIONS: Clinical outcomes of the Surpass flow diverter in the treatment of intracranial aneurysms show a safety profile that is comparable with that of stent-assisted coil embolization. Angiographic results showed a high rate of intracranial aneurysm occlusion.


Assuntos
Prótese Vascular , Aneurisma Intracraniano/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral/instrumentação , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
8.
AJNR Am J Neuroradiol ; 34(11): 2163-70, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23721899

RESUMO

BACKGROUND AND PURPOSE: Developments in flat panel angiographic C-arm systems have enabled visualization of both the neurovascular stents and host arteries in great detail, providing complementary spatial information in addition to conventional DSA. However, the visibility of these structures may be impeded by artifacts generated by adjacent radio-attenuating objects. We report on the use of a metal artifact reduction algorithm for high-resolution contrast-enhanced conebeam CT for follow-up imaging of stent-assisted coil embolization. MATERIALS AND METHODS: Contrast-enhanced conebeam CT data were acquired in 25 patients who underwent stent-assisted coiling. Reconstructions were generated with and without metal artifact reduction and were reviewed by 3 experienced neuroradiologists by use of a 3-point scale. RESULTS: With metal artifact reduction, the observers agreed that the visibility had improved by at least 1 point on the scoring scale in >40% of the cases (κ = 0.6) and that the streak artifact was not obscuring surrounding structures in 64% of all cases (κ = 0.6). Metal artifact reduction improved the image quality, which allowed for visibility sufficient for evaluation in 65% of the cases, and was preferred over no metal artifact reduction in 92% (κ = 0.9). Significantly higher scores were given with metal artifact reduction (P < .0001). CONCLUSIONS: Although metal artifact reduction is not capable of fully removing artifacts caused by implants with high x-ray absorption, we have shown that the image quality of contrast-enhanced conebeam CT data are improved drastically. The impact of the artifacts on the visibility varied between cases, and yet the overall visibility of the contrast-enhanced conebeam CT with metal artifact reduction improved in most the cases.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents , Ecrans Intensificadores para Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Humanos , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
AJNR Am J Neuroradiol ; 34(4): E36-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22081678

RESUMO

We report a novel model of arterial tortuosity in the porcine brachial artery for testing of endovascular devices in the flexed forelimb position. This provides an ideal vascular territory for an in vivo assessment of guidewires, microcatheters, and endovascular implants because it closely mimics the challenging curvature at the carotid siphon.


Assuntos
Artéria Braquial/diagnóstico por imagem , Cateterismo/métodos , Procedimentos Endovasculares/métodos , Membro Anterior/irrigação sanguínea , Angiografia Digital , Animais , Artéria Carótida Primitiva , Artéria Carótida Interna , Cateterismo/instrumentação , Procedimentos Endovasculares/instrumentação , Membro Anterior/diagnóstico por imagem , Humanos , Masculino , Modelos Animais , Stents , Artéria Subclávia , Sus scrofa
10.
J Huntingtons Dis ; 2(1): 41-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-25063428

RESUMO

Our goal is delivery of a long-term treatment for Huntington's disease. We administer intracerebrally in sheep adeno-associated virus (AAV) to establish optimal safety, spread and neuronal uptake of AAV based therapeutics. Sheep have large gyrencephalic brains and offer the opportunity to study a transgenic Huntington's disease model. However, lack of a relevant brain stereotactic atlas and the difficulty of skull fixation make conventional stereotaxy unreliable. We describe a multi-modal image-guidance technique to achieve accurate placement of therapeutics into the sheep striatum.


Assuntos
Corpo Estriado/cirurgia , Modelos Animais de Doenças , Terapia Genética/métodos , Vetores Genéticos/administração & dosagem , Doença de Huntington , Animais , Animais Geneticamente Modificados , Convecção , Corpo Estriado/anatomia & histologia , Dependovirus , Doença de Huntington/terapia , Carneiro Doméstico , Técnicas Estereotáxicas
11.
AJNR Am J Neuroradiol ; 33(10): 1998-2003, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22555570

RESUMO

BACKGROUND AND PURPOSE: A number of thrombectomy devices are currently undergoing clinical evaluation; meanwhile, various novel devices are under investigation. The aims of this study were to quantify flow restoration and the particle size distribution of the effluent pursuant to MET in an in vitro occlusion model. MATERIALS AND METHODS: The model system was composed of 3 elements: an ICA/MCA replica, a clot model with mechanical properties similar to those of thrombi found in patients at risk of stroke, and a pulsatile flow loop. Different thrombectomy mechanisms including mechanical retrieval, aspiration, and waveguide induced cavitation were used. The efficacy end points were recanalization rate and amount of flow restoration. The risk of the embolic shower was assessed to evaluate device safety. RESULTS: The recanalization rates were the following: Merci, 67%; Solitaire, 100%; Penumbra, 83%; Enterprise, 17%; and the waveguide, 0%. In experiments in which recanalization was achieved, the amount of flow restoration for the Merci, Solitaire, and Enterprise devices was 100%, 92%, and 86%, respectively. The mean sizes of generated small and large clot fragments were between 23 and 37 and 215 and 285 µm, respectively, depending on the device used. The Merci device generated the fewest number of large fragments compared with the Penumbra system (P < .05) and Solitaire (not significant). CONCLUSIONS: The risk of embolic shower was influenced by the mechanism of action for the thrombectomy device. Clinically reported recanalization rates for the Solitaire, Penumbra, and Merci devices were nearly identical in this model system, suggesting that this model may provide a predictive tool for preclinical evaluation of MET.


Assuntos
Circulação Cerebrovascular , Transtornos Cerebrovasculares/fisiopatologia , Transtornos Cerebrovasculares/cirurgia , Trombólise Mecânica/instrumentação , Trombólise Mecânica/métodos , Materiais Biomiméticos , Velocidade do Fluxo Sanguíneo , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Resultado do Tratamento
12.
AJNR Am J Neuroradiol ; 33(9): 1657-62, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22538075

RESUMO

BACKGROUND AND PURPOSE: Recently, the use of stents to assist in the coiling and repair of wide-neck aneurysms has been shown to be highly effective; however, the effect of these stents on the RC of the parent vessel has not been quantified. The purpose of this study was to quantify the effect of intracranial stenting on the RC of the implanted artery using 3D datasets. MATERIALS AND METHODS: Twenty-four patients receiving FDA-approved neurovascular stents to support coil embolization of brain aneurysms were chosen for this study. The stents were located in the ICA, ACA, or MCA. We analyzed C-arm rotational angiography and contrast-enhanced cone beam CT datasets before and after stent implantation, respectively, to ascertain changes in vessel curvature. The images were reconstructed, and the vessel centerline was extracted. From the centerline, the RC was calculated. RESULTS: The average implanted stent length was 25.4 ± 5.8 mm, with a pre-implantation RC of 7.1 ± 2.1 mm and a postimplantation RC of 10.7 ± 3.5 mm. This resulted in a 3.6 ± 2.7 mm change in the RC due to implantation (P < .0001), more than a 50% increase from the pre-implantation value. There was no difference in the change of RC for the different locations studied. The change in RC was not impacted by the extent of coil packing within the aneurysm. CONCLUSIONS: The implantation of neurovascular stents can be shown to have a large impact on the RC of the vessel. This will lead to a change in the local hemodynamics and flow pattern within the aneurysm.


Assuntos
Prótese Vascular , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Trombólise Mecânica/instrumentação , Trombólise Mecânica/métodos , Stents , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos , Radiografia , Resultado do Tratamento , Adulto Jovem
13.
AJNR Am J Neuroradiol ; 33(9): 1651-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22492570

RESUMO

BACKGROUND AND PURPOSE: Recanalization is observed in 20-40% of endovascularly treated intracranial aneurysms. To further reduce the recanalization and expand endovascular treatment, we evaluated the safety and efficacy of closed-cell SACE. MATERIALS AND METHODS: Between 2007 and 2010, 147 consecutive patients (110 women; mean age, 54 years) presenting at 2 centers with 161 wide-neck ruptured and unruptured aneurysms were treated by using SACE. Inclusion criteria were wide-neck aneurysms (>4 mm or a dome/neck ratio ≤ 2). Clinical outcomes were assessed by the mRS score at baseline, discharge, and follow-up. Aneurysm occlusion was assessed on angiograms by using the RS immediately after SACE and at follow-up. RESULTS: Eighteen aneurysms (11%) were treated following rupture. Procedure-related mortality and permanent neurologic deficits occurred in 2 (1.4%) and 5 patients (3.4%), respectively. In total, 7 patients (4.8%) died, including 2 with reruptures. Of the 140 surviving patients, 113 (80.7%) patients with 120 aneurysms were available for follow-up neurologic examination at a mean of 11.8 months. An increase in mRS score from admission to follow-up by 1, 2, or 3 points was seen in 7 (6.9%), 1 (1%), and 2 (2%) patients, respectively. Follow-up angiography was performed in 120 aneurysms at a mean of 11.9 months. Recanalization occurred in 12 aneurysms (10%), requiring retreatment in 7 (5.8%). Moderate in-stent stenosis was seen in 1 (0.8%), which remained asymptomatic. CONCLUSIONS: This series adds to the evidence demonstrating the safety and effectiveness of SACE in the treatment of intracranial aneurysms. However, SACE of ruptured aneurysms and premature termination of antiplatelet treatment are associated with increased morbidity and mortality.


Assuntos
Prótese Vascular , Angiografia Cerebral , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Trombólise Mecânica/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Massachusetts , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Acta Neurochir (Wien) ; 154(1): 21-6; discussion 26, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22002552

RESUMO

BACKGROUND: Primary endovascular reconstruction with flow diversion represents a fundamental paradigm shift in the technique of endovascular aneurysm treatment. Unlike coil embolization, often there remains residual post-procedural filling within the aneurysm with flow diverters, the curative reconstruction presumably occurring over a period of weeks. Thus, conventional grading scales for post-procedural aneurysm occlusion and recanalization are inadequate. The aim of this paper is to propose a new angiographic grading scale that addresses this fundamentally new treatment option. METHOD: A five-point grading scale describes the location of residual flow within the aneurysm in the venous phase [grade 1: patent aneurysm with diffuse inflow; grade 2: residual filling of the aneurysm dome (saccular) or wall (fusiform); grade 3: only residual neck (saccular) or only intra-aneurysmal filling with former boundaries covered (fusiform); grade 4: complete occlusion]. FINDINGS: Grade 0 represents any aneurysm, regardless of occlusion rate with early phase, coherent inflow jet. Intra-aneurysmal flow stagnation is categorized into: (a) none, (b) capillary phase, and (c) venous phase. Prevailing parent vessel hemodynamics with in-stent stenosis (ISS) are divided into none (ISS0), mild (ISS1), moderate (ISS2), severe (ISS3), and total (ISS4) occlusion. The proposed grading scales allow assessment of the hemodynamic consequences of stent placement on endosaccular in-flow, stasis, and location of stasis as well as parent vessel hemodynamics. CONCLUSIONS: Further studies need to show the applicability and possible predictive value of this new grading scale on the efficacy of the stent in promoting intra-aneurysmal flow stagnation, thus creating the potential to harmonize the results of future papers. This may help to optimize treatment and future device design.


Assuntos
Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/fisiopatologia , Aneurisma Intracraniano/terapia , Modelos Cardiovasculares , Stents/normas , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Lactente , Aneurisma Intracraniano/patologia , Stents/efeitos adversos
15.
AJNR Am J Neuroradiol ; 33(4): 655-60, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22194374

RESUMO

BACKGROUND AND PURPOSE: Intracranial aneurysms treated by coiling have a risk for recurrence, requiring surveillance imaging. MRA has emerged as an attractive technique for postcoiling aneurysm imaging. Previous research has evaluated MR imaging artifacts of the coil mass in vitro. Our aim in this study was to evaluate MR imaging artifacts of coiled aneurysms in vivo with time. MATERIALS AND METHODS: Four sidewall aneurysms were created in each of 4 dogs. Aneurysms were embolized receiving only 1 type of coils. After embolization, the animals were transferred to MR imaging, which included axial 3D TOF MRA (TEs, 3.5, 5, and 6.9 ms), phase-contrast MRA, and coronal CE-MRA. MR imaging studies were repeated at 1, 4, 6, 8, 14, and 28 weeks. We calculated an OEF: OEF = V(A)/V(CM), where the numerator represents the volume of the MR imaging artifacts and the denominator is the true volume of the coil mass measured by 3D RA. RESULTS: OEFs were largest immediately after embolization and showed a gradual decay until approximately 4 weeks, when there was stabilization of the size of the artifacts. By 4 weeks, there was mild coil compaction (average coil mass volume decrease of 7.8%); however, the OEFs decreased by 25% after 4 weeks (P < .001). CONCLUSIONS: MR imaging susceptibility artifacts change with time, being maximal in the postembolization setting and decaying until 4 weeks. The clinical implications of this study are that baseline MRA for comparison with future imaging should be acquired at a minimum of 1 week after the procedure.


Assuntos
Artefatos , Modelos Animais de Doenças , Aumento da Imagem/métodos , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/cirurgia , Angiografia por Ressonância Magnética/métodos , Trombólise Mecânica/instrumentação , Animais , Cães , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
AJNR Am J Neuroradiol ; 33(2): 353-8, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22173756

RESUMO

BACKGROUND AND PURPOSE: Previous studies have shown the feasibility of assessing qualitative CBV measurements in the angiography suite by using FPD-CBCT systems. We have investigated the correlation of FPD-CBCT CBV lesion volumes to the infarct volume. MATERIALS AND METHODS: Unilateral strokes were created in 7 adult dogs. MR imaging and FPD-CBCT data were obtained after MCA occlusion. FPD-CBCT CBV and ADC maps were generated for all subjects. The animals were sacrificed immediately following the last imaging study to measure infarct volume on histology. The reliability of FPD-CBCT-based lesion volume measurements was compared with those measured histologically by using regression and Bland-Altman analysis. RESULTS: The best correlation (R(2) = 0.72) between lesion volumes assessed with FPD-CBCT and histology was established with a threshold of mean healthy CBV - 2.5 × SD. These results were inferior to the correlation of lesion volumes measured with ADC and histology (R(2) = 0.99). Bland-Altman analysis showed that the agreement of ADC-derived lesion volumes with histology was superior to the agreement of FPD-CBCT-derived lesion volumes with histology. CONCLUSIONS: We correlated FPD-CBCT measurements of CBV and MR ADC lesion volumes with histologically assessed infarct volume. As expected, ADC is a very accurate and precise method for determining the extent of infarction. FPD-CBCT CBV lesion volumes are correlated to the size of the infarct. Improvement of FPD-CBCT image quality provides an opportunity to establish quantitative CBV measurement in the angiography suite.


Assuntos
Volume Sanguíneo , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Tomografia Computadorizada por Raios X , Animais , Modelos Animais de Doenças , Cães
17.
AJNR Am J Neuroradiol ; 32(7): 1237-44, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21596804

RESUMO

BACKGROUND AND PURPOSE: Mechanical behavior of the thromboembolus is one of the key factors that determine the efficacy of thrombectomy devices for revascularization in AIS. We characterized the mechanical properties and composition of thromboemboli from clinical cases and compared them with commonly used EAs. MATERIALS AND METHODS: Thromboemboli were obtained from patients with AIS by using aspiration devices and from carotid atherosclerotic plaques harvested during endarterectomy. In the laboratory, common EAs were created by varying blood donor species (human, porcine, and bovine), thrombin concentration, and presence of barium sulfate. Stiffness and elasticity of the specimens were measured with DMA. Scanning electron microscopy and histology were used to investigate the ultrastructure and composition of all specimens. RESULTS: Red thromboemboli from patients composed mainly of fibrin and erythrocytes were much softer than the calcified and cholesterol-rich material. Of the EAs created in the laboratory, those made from bovine blood presented the highest stiffness that was independent of thrombin concentration. Addition of thrombin increased the stiffness and elasticity of human and porcine EAs (P < .05). The presence of barium sulfate significantly reduced the elasticity of all EAs (P < .05). CONCLUSIONS: Endovascular device testing and development requires realistic EAs. The stiffness and elasticity of the cerebral thromboemboli analyzed in this study were closely matched by recalcified porcine EAs and thrombin-induced human EAs. Stiffness of the thrombus extracted from carotid endarterectomy specimens was similar with that of the thrombin-induced bovine and porcine EAs.


Assuntos
Isquemia Encefálica/sangue , Infarto da Artéria Cerebral Média/sangue , Tromboembolia/sangue , Tromboembolia/fisiopatologia , Doença Aguda , Idoso , Animais , Sulfato de Bário/farmacologia , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/fisiologia , Bovinos , Elasticidade/efeitos dos fármacos , Eritrócitos/fisiologia , Fibrina/fisiologia , Humanos , Masculino , Especificidade da Espécie , Estresse Mecânico , Suínos , Trombectomia , Trombina/farmacologia
18.
Phys Med Biol ; 56(4): 1031-43, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21258138

RESUMO

Spatial and soft tissue information provided by magnetic resonance imaging can be very valuable during image-guided procedures, where usually only real-time two-dimensional (2D) x-ray images are available. Registration of 2D x-ray images to three-dimensional (3D) magnetic resonance imaging (MRI) data, acquired prior to the procedure, can provide optimal information to guide the procedure. However, registering x-ray images to MRI data is not a trivial task because of their fundamental difference in tissue contrast. This paper presents a technique that generates pseudo-computed tomography (CT) data from multi-spectral MRI acquisitions which is sufficiently similar to real CT data to enable registration of x-ray to MRI with comparable accuracy as registration of x-ray to CT. The method is based on a k-nearest-neighbors (kNN)-regression strategy which labels voxels of MRI data with CT Hounsfield Units. The regression method uses multi-spectral MRI intensities and intensity gradients as features to discriminate between various tissue types. The efficacy of using pseudo-CT data for registration of x-ray to MRI was tested on ex vivo animal data. 2D-3D registration experiments using CT and pseudo-CT data of multiple subjects were performed with a commonly used 2D-3D registration algorithm. On average, the median target registration error for registration of two x-ray images to MRI data was approximately 1 mm larger than for x-ray to CT registration. The authors have shown that pseudo-CT data generated from multi-spectral MRI facilitate registration of MRI to x-ray images. From the experiments it could be concluded that the accuracy achieved was comparable to that of registering x-ray images to CT data.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Humanos
19.
AJNR Am J Neuroradiol ; 32(1): 137-44, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20966059

RESUMO

BACKGROUND AND PURPOSE: With modern imaging techniques, visualization of neurovascular stents remains challenging. We present a method for contrast-enhanced C-arm CBCT that provides detailed and simultaneous visualization of neurovascular stents and host arteries. MATERIALS AND METHODS: CBCT was performed with a rotational angiography system by acquiring 620 projection frames over a 200° arc at 80 kVp and a total of 260 mAs. A superselective intra-arterial contrast injection protocol was optimized in swine experiments and implemented in 57 clinical examinations. High-resolution 3D reconstructions were evaluated by 3 blinded interventional neuroradiologists. Reviewers rated the images by answering questions related to both the quality of the stent and artery visualization and the clinical utility of the images. Raw agreement statistics, ICC, and κ statistics were computed for the questionnaire results. RESULTS: Of 57 clinical evaluations, 5 were not evaluated due to the use of large balloon-mounted stents (n = 4) and a failed contrast injection (n = 1). In 50 of 52 evaluated examinations, the reviewers agreed that simultaneous stent and vessel visualization was of diagnostic quality. There was strong agreement that stent-vessel wall apposition could be assessed (κ = 0.79). CBCT detected contrast filling defects (κ = 0.85) and vascular calcification (κ = 0.68). Artifacts resulting from the aneurysm coil mass impaired the delineation of adjacent structures (κ = 0.72). CONCLUSIONS: We have developed a technique that enables simultaneous clinically useful imaging of neurovascular stents and their host arteries that is unobtainable with other current imaging modalities. Further improvements are required to reduce artifacts from large coil masses due to x-ray scattering.


Assuntos
Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Iopamidol , Intensificação de Imagem Radiográfica/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Animais , Prótese Vascular , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Resultado do Tratamento
20.
Gene Ther ; 17(10): 1279-87, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20485380

RESUMO

Both atherosclerosis and arterial interventions induce oxidative stress mediated in part by nicotinamide adenine dinucleotide phosphate (NADPH) oxidases that have a pivotal role in the development of neointimal hyperplasia and restenosis. For small interfering RNA (siRNA) targeting of the NOX2 (Cybb) component of the NADPH oxidase to prevent restenosis, gene transfer with viral vectors is effective, but raises safety issues in humans. We developed a new approach using the amino-acid-based nanoparticle HB-OLD7 for local delivery of siRNA targeting NOX2 to the arterial wall. siRNA-nanoparticle complexes were transferred into the regional carotid artery walls after angioplasty in an atherosclerotic rat model. Compared with angioplasty controls, Cybb gene expression (measured by quantitative reverse transcriptase-PCR) in the experimental arterial wall 2 weeks after siRNA was reduced by >87%. The neointima-to-media-area ratio was decreased by >83%, and the lumen-to-whole-artery area ratio was increased by >89%. Vital organs showed no abnormalities and splenic Cybb gene expression showed no detectable change. Thus, local arterial wall gene transfer with HB-OLD7 nanoparticles provides an effective, nonviral system for efficient and safe local gene transfer in a clinically applicable approach to knock down an NADPH oxidase gene. Local arterial knockdown of the Cybb gene significantly inhibited neointimal hyperplasia and preserved the vessel lumen without systemic toxicity.


Assuntos
Aterosclerose/terapia , Glicoproteínas de Membrana/antagonistas & inibidores , NADPH Oxidases/antagonistas & inibidores , Nanopartículas/administração & dosagem , RNA Interferente Pequeno/administração & dosagem , Animais , Aterosclerose/genética , Aterosclerose/patologia , Vetores Genéticos/administração & dosagem , Hiperplasia/metabolismo , Hiperplasia/patologia , Masculino , Glicoproteínas de Membrana/genética , Camundongos , Modelos Animais , NADPH Oxidase 2 , NADPH Oxidases/genética , Neointima/metabolismo , Neointima/patologia , RNA Interferente Pequeno/genética , Ratos , Ratos Sprague-Dawley , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA