Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
ACS Omega ; 9(27): 29391-29400, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-39005803

RESUMO

X-ray attenuating contrast agents for imaging thrombi directly during endovascular thrombectomy (EVT) are urgently needed for shortening the wait time for treatment and for reducing the chances of blood clot fragmentation. Neutrophil extracellular traps (NETs) are a product of an innate immune system response by which neutrophils release decondensed chromatin strands decorated with granule and cytosolic proteins, including neutrophil elastase and citrullinated histone H3 (CitH3). NETs are frequently found within fibrous thrombi in pathology and represent a promising target for thrombi-specific imaging agents due to their common occurrence in human cerebrovascular thrombi. We designed and tested 200 nm lipid vesicles (LV) formulated in the presence of a combination of hydrophilic and hydrophobic computed tomography (CT) contrast agents with resultant efficacy of X-ray attenuation corresponding to 312 ± 54 mg/mL iodine. The LV incorporated trans-cyclooctene-terminated pegylated distearoylphosphatidylethanolamine (TCO-PEG-DSPE) for rapid conjugation of methyltetrazine(mTz)-modified monoclonal immunoglobulin G (IgG) with anti-citH3 binding specificity. By using differential fluorescent labeling of the antibody and lipid components, we determined that 80 ± 3% of mTz-linked IgG coprecipitated with the LV after conjugation in contrast to 0.1-0.2% of control IgG. The engineered NET-specific LV were tested in vitro using differentiated human HL60 promyeloblasts (dHL60) as a standard model of NETing neutrophils. Using fibrin meshwork-incorporated dHL60 as well as monolayer cell cultures, we determined that anti-citH3 LV showed specific and high-affinity binding to dHL60 cells, which were stimulated to undergo NETosis. This work suggests the high promise of NET-specific agents in providing thrombus-specific imaging contrast during EVT.

2.
Interv Neuroradiol ; : 15910199241266010, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043215

RESUMO

BACKGROUND: Therapeutic hypothermia has shown potential in cardiac intervention for years; however, its adoption into the neurovascular space has been limited. Studies have pointed to slow cooling and limited depth of hypothermia yielding negative outcomes. Here we present an insulated catheter that allows for consistent infusion of chilled saline directly to the brain. Direct delivery of cold saline allows a faster depth of hypothermia, which could have a benefit to the growth of ischemic lesions. METHODS: Ten canines were randomized to either receive selective brain cooling or no additional therapy. Eight animals were successfully enrolled (n = 4 per group). Each animal underwent a temporary middle cerebral artery occlusion (MCAO) for a total of 45 min. Five minutes prior to flow restoration, chilled saline was injected through the ipsilateral internal carotid artery using an insulated catheter to ensure delivery temperature. The treatment continued for 20 min, after which the animal was transferred to an MRI scanner for imaging. RESULTS: Of the 8 animals that were successfully enrolled in the study, 3 were able to survive to the 30-day endpoint with no differences between the cooled and control animals. There was no difference in the initial mean infarct size between the groups; however, animals that did not receive cooling had infarcts continuing to progress more rapidly after the MCAO was removed (13.8% vs 161.3%, p = 0.016, cooled vs control). CONCLUSIONS: Selective hypothermia was able to reduce the post-MCAO infarct progression in a canine model of temporary MCAO.

3.
J Neurointerv Surg ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38830670

RESUMO

BACKGROUND: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy. METHODS: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies. RESULTS: A standardized methodology is proposed for evaluating and reporting radiological outcomes of FD treatment of intracranial aneurysms. The recommendations include general imaging considerations for clinical studies and evaluations of longitudinal changes, such as neointimal lining and stenosis. They cover standards for classification of aneurysm location, morphology, measurements, as well as the assessment of aneurysm occlusion, wall apposition, and neck coverage. These reporting standards further define four specific braid deformation patterns: foreshortening, fish-mouthing, braid bump deformation, and braid collapse, collectively termed 'F2B2'. CONCLUSIONS: When widely applied, standardization of methods of measuring and reporting outcomes will help to harmonize the assessment of treatment outcomes in clinical studies, help facilitate communication of results among specialists, and help enable research and development to focus on specific aspects of FD techniques and technology.

4.
Sci Transl Med ; 16(747): eadl4497, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748771

RESUMO

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography (nOCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The nOCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using nOCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. nOCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


Assuntos
Artérias Cerebrais , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Artérias Cerebrais/diagnóstico por imagem , Microscopia/métodos , Miniaturização , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos
5.
Stroke ; 55(5): 1428-1437, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648283

RESUMO

BACKGROUND: Intracranial aneurysms (IAs) remain a challenging neurological diagnosis associated with significant morbidity and mortality. There is a plethora of microsurgical and endovascular techniques for the treatment of both ruptured and unruptured aneurysms. There is no definitive consensus as to the best treatment option for this cerebrovascular pathology. The Aneurysm, Arteriovenous Malformation, and Chronic Subdural Hematoma Roundtable Discussion With Industry and Stroke Experts discussed best practices and the most promising approaches to improve the management of brain aneurysms. METHODS: A group of experts from academia, industry, and federal regulators convened to discuss updated clinical trials, scientific research on preclinical system models, management options, screening and monitoring, and promising novel device technologies, aiming to improve the outcomes of patients with IA. RESULTS: Aneurysm, Arteriovenous Malformation, and Chronic Subdural Hematoma Roundtable Discussion With Industry and Stroke Experts suggested the incorporation of artificial intelligence to capture sequential aneurysm growth, identify predictors of rupture, and predict the risk of rupture to guide treatment options. The consensus strongly recommended nationwide systemic data collection of unruptured IA radiographic images for the analysis and development of machine learning algorithms for rupture risk. The consensus supported centers of excellence for preclinical multicenter trials in areas such as genetics, cellular composition, and radiogenomics. Optical coherence tomography and magnetic resonance imaging contrast-enhanced 3T vessel wall imaging are promising technologies; however, more data are needed to define their role in IA management. Ruptured aneurysms are best managed at large volume centers, which should include comprehensive patient management with expertise in microsurgery, endovascular surgery, neurology, and neurocritical care. CONCLUSIONS: Clinical and preclinical studies and scientific research on IA should engage high-volume centers and be conducted in multicenter collaborative efforts. The future of IA diagnosis and monitoring could be enhanced by the incorporation of artificial intelligence and national radiographic and biologic registries. A collaborative effort between academic centers, government regulators, and the device industry is paramount for the adequate management of IA and the advancement of the field.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Roto/terapia , Aneurisma Roto/diagnóstico por imagem , Consenso , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico
6.
J Neurointerv Surg ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388479

RESUMO

BACKGROUND: Middle meningeal artery (MMA) embolization is a promising intervention as a stand-alone or adjunct treatment to surgery in patients with chronic subdural hematomas. There are currently no large animal models for selective access and embolization of the MMA for preclinical evaluation of this endovascular modality. Our objective was to introduce a novel in vivo model of selective MMA embolization in swine. METHODS: Diagnostic cerebral angiography with selective microcatheter catheterization into the MMA was performed under general anesthesia in five swine. Anatomical variants in arterial meningeal supply were examined. In two animals, subsequent embolization of the MMA with a liquid embolic agent (Onyx-18) was performed, followed by brain tissue harvest and histological analysis. RESULTS: The MMA was consistently localized as a branch of the internal maxillary artery just distal to the origin of the ascending pharyngeal artery. Additional meningeal supply was observed from the external ophthalmic artery, although not present consistently. MMA embolization with Onyx was technically successful and feasible. Histological analysis showed Onyx material within the MMA lumen. CONCLUSIONS: Microcatheter access into the MMA in swine with liquid embolic agent delivery represents a reproducible model of MMA embolization. Anatomical variations in the distribution of arterial supply to the meninges exist. This model has a potential application for comparing therapeutic effects of various embolic agents in a preclinical setting that closely resembles the MMA embolization procedure in humans.

7.
J Neurointerv Surg ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38124177

RESUMO

BACKGROUND: The aim of this study was to evaluate the overall rates of braid changes associated with flow diverter (FD) treatment for intracranial aneurysms (IAs). Additionally, we sought to provide an overview of the currently reported definitions related to these complications. METHODS: A systematic search was conducted from the inception of relevant literature up to April 2023, encompassing six databases. The included studies focused on patients with IAs treated with FDs. We considered four main outcome measures as FD braid changes: (1) fish-mouthing, (2) device braid narrowing, (3) device braid collapsing, and (4) device braid deformation. The data from these studies were pooled using a random-effects model. RESULTS: A total of 48 studies involving 3572 patients were included in the analysis. Among them, 14 studies (39%) provided definitions for fish-mouthing. However, none of the included studies offered specific definitions for device braid narrowing, collapsing, or deformation, despite reporting rates for these complications in six, five, and three studies, respectively. The pooled rates for braid changes were as follows: 3% (95% CI 2% to 4%, I2=27%) for fish-mouthing, 7% (95% CI 2% to 20%, I2=85%) for narrowing, 1% (95% CI 0% to 3%, I2=0%) for collapsing, and 1% (95% CI 1% to 4%, I2=0%) for deformation. CONCLUSION: The findings of this study suggest that FD treatment for IAs generally exhibits low rates of fish-mouthing, device braid narrowing, collapsing, and deformation. However, the lack of standardized definitions hinders the ability to compare device outcomes objectively, emphasizing the need for uniform definitions for FD braid changes in future prospective studies on FD.

8.
Mol Ther Methods Clin Dev ; 31: 101122, 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-37920238

RESUMO

Oligonucleotide therapeutics offer great promise in the treatment of previously untreatable neurodegenerative disorders; however, there are some challenges to overcome in pre-clinical studies. (1) They carry a well-established dose-related acute neurotoxicity at the time of administration. (2) Repeated administration into the cerebrospinal fluid may be required for long-term therapeutic effect. Modifying oligonucleotide formulation has been postulated to prevent acute toxicity, but a sensitive and quantitative way to track seizure activity in pre-clinical studies is lacking. The use of intracerebroventricular (i.c.v.) catheters offers a solution for repeated dosing; however, fixation techniques in large animal models are not standardized and are not reliable. Here we describe a novel surgical technique in a sheep model for i.c.v. delivery of neurotherapeutics based on the fixation of the i.c.v. catheter with a 3D-printed anchorage system composed of plastic and ceramic parts, compatible with magnetic resonance imaging, computed tomography, and electroencephalography (EEG). Our technique allowed tracking electrical brain activity in awake animals via EEG and video recording during and for the 24-h period after administration of a novel oligonucleotide in sheep. Its anchoring efficiency was demonstrated for at least 2 months and will be tested for up to a year in ongoing studies.

9.
J Neurointerv Surg ; 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37793794

RESUMO

Flow-diverting stents (FDs) for the treatment of cerebrovascular aneurysms are revolutionary. However, these devices require systemic dual antiplatelet therapy (DAPT) to reduce thromboembolic complications. Given the risk of ischemic complications as well as morbidity and contraindications associated with DAPT, demonstrating safety and efficacy for FDs either without DAPT or reducing the duration of DAPT is a priority. The former may be achieved by surface modifications that decrease device thrombogenicity, and the latter by using coatings that expedite endothelial growth. Biomimetics, commonly achieved by grafting hydrophilic and non-interacting polymers to surfaces, can mask the device surface with nature-derived coatings from circulating factors that normally activate coagulation and inflammation. One strategy is to mimic the surfaces of innocuous circulatory system components. Phosphorylcholine and glycan coatings are naturally inspired and present on the surface of all eukaryotic cell membranes. Another strategy involves linking synthetic biocompatible polymer brushes to the surface of a device that disrupts normal interaction with circulating proteins and cells. Finally, drug immobilization can also impart antithrombotic effects that counteract normal foreign body reactions in the circulatory system without systemic effects. Heparin coatings have been explored since the 1960s and used on a variety of blood contacting surfaces. This concept is now being explored for neurovascular devices. Coatings that improve endothelialization are not as clinically mature as anti-thrombogenic coatings. Coronary stents have used an anti-CD34 antibody coating to capture circulating endothelial progenitor cells on the surface, potentially accelerating endothelial integration. Similarly, coatings with CD31 analogs are being explored for neurovascular implants.

10.
J Neurointerv Surg ; 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527927

RESUMO

BACKGROUND: Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. METHODS: In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. RESULTS: Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (P<0.001) as did incompletely occluded aneurysms (P<0.001). Histologically, all aneurysms treated with SEAL Arc devices were completely healed. CONCLUSION: Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.

11.
J Neurointerv Surg ; 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37419694

RESUMO

BACKGROUND: Mechanical thrombectomy (MT) has become standard for large vessel occlusions, but rates of complete recanalization are suboptimal. Previous reports correlated radiographic signs with clot composition and a better response to specific techniques. Therefore, understanding clot composition may allow improved outcomes. METHODS: Clinical, imaging, and clot data from patients enrolled in the STRIP Registry from September 2016 to September 2020 were analyzed. Samples were fixed in 10% phosphate-buffered formalin and stained with hematoxylin-eosin and Martius Scarlett Blue. Percent composition, richness, and gross appearance were evaluated. Outcome measures included the rate of first-pass effect (FPE, modified Thrombolysis in Cerebral Infarction 2c/3) and the number of passes. RESULTS: A total of 1430 patients of mean±SD age 68.4±13.5 years (median (IQR) baseline National Institutes of Health Stroke Scale score 17.2 (10.5-23), IV-tPA use 36%, stent-retrievers (SR) 27%, contact aspiration (CA) 27%, combined SR+CA 43%) were included. The median (IQR) number of passes was 1 (1-2). FPE was achieved in 39.3% of the cases. There was no association between percent histological composition or clot richness and FPE in the overall population. However, the combined technique resulted in lower FPE rates for red blood cell (RBC)-rich (P<0.0001), platelet-rich (P=0.003), and mixed (P<0.0001) clots. Fibrin-rich and platelet-rich clots required a higher number of passes than RBC-rich and mixed clots (median 2 and 1.5 vs 1, respectively; P=0.02). CA showed a trend towards a higher number of passes with fibrin-rich clots (2 vs 1; P=0.12). By gross appearance, mixed/heterogeneous clots had lower FPE rates than red and white clots. CONCLUSIONS: Despite the lack of correlation between clot histology and FPE, our study adds to the growing evidence supporting the notion that clot composition influences recanalization treatment strategy outcomes.

12.
J Neurointerv Surg ; 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37402572

RESUMO

BACKGROUND: Flow diversion has become a standard treatment for cerebral aneurysms. However, major drawbacks include the need for dual antiplatelet therapy after implant and delayed complete occlusion of the aneurysm, which occurs when new tissue growth excludes the aneurysm from the parent artery. Biomimetic surface modifications such as the phosphorylcholine polymer (Shield surface modification) represent major advances in reducing thrombogenicity of these devices. However, in vitro studies have raised concerns that this modification may also delay endothelialization of flow diverters. METHODS: Bare metal Pipeline, Pipeline Shield, and Vantage with Shield devices were implanted in the common carotid arteries (CCAs) of 10 rabbits (two in the left CCA, one in the right CCA). Following implant and at 5, 10, 15, and 30 days, the devices were imaged with high-frequency optical coherence tomography and conventional angiography to evaluate tissue growth. At 30 days the devices were explanted and their endothelial growth was assessed with scanning electron microscopy (SEM) at five locations along their length using a semi-quantitative score. RESULTS: The average tissue growth thickness (ATGT) was not different between the three devices. Neointima was apparent at 5 days and all devices demonstrated similar ATGT at each time point. On SEM, no difference was found in the endothelium scores between the device types. CONCLUSION: In vivo, neither the Shield surface modification nor the device design (Vantage) altered the longitudinal healing of the flow diverter.

13.
J Neurointerv Surg ; 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37399337

RESUMO

BACKGROUND: Flow diverters carry the risk of thromboembolic complications (TEC). We tested a coating with covalently bound heparin that activates antithrombin to address TEC by locally downregulating the coagulation cascade. We hypothesized that the neuroimaging evidence of TEC would be reduced by the coating. METHODS: 16 dogs were implanted with overlapping flow diverters in the basilar artery, separated into two groups: heparin-coated (n=9) and uncoated (n=7). Following implantation, high-frequency optical coherence tomography (HF-OCT) was acquired to quantify acute thrombus (AT) formation on the flow diverters. MRI was performed postoperatively and repeated at 1, 2, 3, 4, and 8 weeks, consisting of T1-weighted imaging, time-0f-flight (ToF), diffusion weighted imaging (DWI), susceptibility weighted imaging (SWI), and fluid attenuated inversion recovery (FLAIR) sequences. Neurological examinations were performed throughout the 8-week duration of the study. RESULTS: The mean AT volume on coated devices was lower than uncoated (0.014 vs 0.018 mm3); however, this was not significant (P=0.3). The mean number of foci of magnetic susceptibility artifacts (MSAs) on SWI was significantly different between the uncoated and coated groups at the 1-week follow-up (P<0.02), and remained statistically different throughout the duration of the study. The AT volume showed a direct linear correlation with the MSA count and 80% of the variance in the MSA could be explained by the AT volume (P<0.001). Pathological analysis showed evidence of ischemic injury at locations of MSA. CONCLUSIONS: Heparin-coated flow diverters significantly reduced the number of new MSAs after 1 week follow-up, showing the potential to reduce TEC.

15.
Clin Neuroradiol ; 33(4): 1007-1016, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37284876

RESUMO

BACKGROUND: Predicting a challenging clot when performing mechanical thrombectomy in acute stroke can be difficult. One reason for this difficulty is a lack of agreement on how to precisely define these clots. We explored the opinions of stroke thrombectomy and clot research experts regarding challenging clots, defined as difficult to recanalize clots by endovascular approaches, and clot/patient features that may be indicative of such clots. METHODS: A modified DELPHI technique was used before and during the CLOTS 7.0 Summit, which included experts in thrombectomy and clot research from different specialties. The first round included open-ended questions and the second and final rounds each consisted of 30 closed-ended questions, 29 on various clinical and clot features, and 1 on number of passes before switching techniques. Consensus was defined as agreement ≥ 50%. Features with consensus and rated ≥ 3 out of 4 on the certainty scale were included in the definition of a challenging clot. RESULTS: Three DELPHI rounds were performed. Panelists achieved consensus on 16/30 questions, of which 8 were rated 3 or 4 on the certainty scale, namely white-colored clots (mean certainty score 3.1), calcified clots under histology (3.7) and imaging (3.7), stiff clots (3.0), sticky/adherent clots (3.1), hard clots (3.1), difficult to pass clots (3.1) and clots that are resistant to pulling (3.0). Most panelists considered switching endovascular treatment (EVT) techniques after 2-3 unsuccessful attempts. CONCLUSION: This DELPHI consensus identified 8 distinct features of a challenging clot. The varying degree of certainty amongst the panelists emphasizes the need for more pragmatic studies to enable accurate a priori identification of such occlusions prior to EVT.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Trombose , Humanos , Técnica Delphi , Trombose/diagnóstico por imagem , Trombose/terapia , Trombose/patologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Procedimentos Endovasculares/métodos , Isquemia Encefálica/patologia , Resultado do Tratamento
16.
J Clin Neurosci ; 113: 121-125, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37262981

RESUMO

BACKGROUND: Diagnosing and treating acute ischemic stroke patients within a narrow timeframe is challenging. Time needed to access the occluded vessel and initiate thrombectomy is dictated by the availability of information regarding vascular anatomy and trajectory. Absence of such information potentially impacts device selection, procedure success, and stroke outcomes. While the cervical vessels allow neurointerventionalists to navigate devices to the occlusion site, procedures are often encumbered due to tortuous pathways. The purpose of this retrospective study was to determine how neurointerventionalists consider the physical nature of carotid segments when evaluating a procedure's difficulty. METHODS: Seven neurointerventionalists reviewed 3D reconstructions of CT angiograms of left and right carotid arteries from 49 subjects and rated the perceived procedural difficulty on a three-point scale (easy, medium, difficult) to reach the targeted M1. Twenty-two vessel metrics were quantified by dividing the carotids into 5 segments and measuring the radius of curvature, tortuosity, vessel radius, and vessel length of each segment. RESULTS: The tortuosity and length of the arch-cervical and cervical regions significantly impacted difficulty ratings. Additionally, two-way interaction between the radius of curvature and tortuosity on the arch-cervical region was significant (p < 0.0001) wherein, for example, at a given arch-cervical tortuosity, an increased radius of curvature reduced the perceived case difficulty. CONCLUSIONS: Examining the vessel metrics and providing detailed vascular data tailored to patient characteristics may result in better procedure preparation, facilitate faster vessel access time, and improve thrombectomy outcomes. Additionally, documenting these correlations can enhance device design to ensure they suitably function under various vessel conditions.


Assuntos
Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estudos Retrospectivos , Imageamento Tridimensional , Trombectomia/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/métodos
17.
Heliyon ; 9(4): e14837, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37025889

RESUMO

Background: Infarct volume measured from 2,3,5-triphenyltetrazolium chloride (TTC)-stained brain slices is critical to in vivo stroke models. In this study, we developed an interactive, tunable, software that automatically computes whole-brain infarct metrics from serial TTC-stained brain sections. Methods: Three rat ischemic stroke cohorts were used in this study (Total n = 91 rats; Cohort 1 n = 21, Cohort 2 n = 40, Cohort 3 n = 30). For each, brains were serially-sliced, stained with TTC and scanned on both anterior and posterior sides. Ground truth annotation and infarct morphometric analysis (e.g., brain-Vbrain, infarct-Vinfarct, and non-infarct-Vnon-infarct volumes) were completed by domain experts. We used Cohort 1 for brain and infarct segmentation model development (n = 3 training cases with 36 slices [18 anterior and posterior faces], n = 18 testing cases with 218 slices [109 anterior and posterior faces]), as well as infarct morphometrics automation. The infarct quantification pipeline and pre-trained model were packaged as a standalone software and applied to Cohort 2, an internal validation dataset. Finally, software and model trainability were tested as a use-case with Cohort 3, a dataset from a separate institute. Results: Both high segmentation and statistically significant quantification performance (correlation between manual and software) were observed across all datasets. Segmentation performance: Cohort 1 brain accuracy = 0.95/f1-score = 0.90, infarct accuracy = 0.96/f1-score = 0.89; Cohort 2 brain accuracy = 0.97/f1-score = 0.90, infarct accuracy = 0.97/f1-score = 0.80; Cohort 3 brain accuracy = 0.96/f1-score = 0.92, infarct accuracy = 0.95/f1-score = 0.82. Infarct quantification (cohort average): Vbrain (ρ = 0.87, p < 0.001), Vinfarct (0.92, p < 0.001), Vnon-infarct (0.80, p < 0.001), %infarct (0.87, p = 0.001), and infarct:non-infact ratio (ρ = 0.92, p < 0.001). Conclusion: Tectonic Infarct Analysis software offers a robust and adaptable approach for rapid TTC-based stroke assessment.

18.
Interv Neuroradiol ; : 15910199231158444, 2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36872879

RESUMO

BACKGROUND: Neurointerventionalists use in-vitro vascular models to train for worst-case scenarios and test new devices in a simulated use environment to predict clinical performance. According to the Food and Drug Administration (FDA), any neurovascular navigation device should be able to successfully navigate two 360-degree turns and two 180-degree turns at the distal portion of the anatomical model. Here, we present a device benchmarking vascular model that complies with FDA recommendations. METHODS: Our vascular model was assembled from quantitative characterization of 49 patients who underwent CT angiography either for acute ischemic stroke caused by large vessel occlusion or for aneurysm treatment. Following complete characterization of these data, the vascular segments were 3D reconstructed from CT angiograms of 6 selected patients that presented with challenging anatomy. The curvature and total rotational angle were calculated for each segment and the anatomical parts that complied with FDA recommendations were fused together into a single in-vitro model. RESULTS: The model was constructed containing two common carotid branches arising from a type two aortic arch and the dimensions of the overall model exceeded the recommendations of the FDA. Two experienced neurointerventionalists tested the model for navigation difficulty using several devices on an in-vitro perfusion system and concluded that the model provided a realistic, challenging scenario. CONCLUSIONS: This model provides a first prototype designed according to FDA recommendations of cumulative angle while also integrating an aggregation of actual patient-specific anatomy. The availability of this clinically relevant benchmark model presents a potential standardized approach for neurovascular device testing.

19.
J Neurointerv Surg ; 15(12): 1207-1211, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36878688

RESUMO

BACKGROUND: The first-pass complete recanalization by mechanical thrombectomy (MT) for the treatment of stroke remains limited due to the poor integration of the clot within current devices. Aspiration can help retrieval of the main clot but fails to prevent secondary embolism in the distal arterial territory. The dense meshes of extracellular DNA, recently described in stroke-related clots, might serve as an anchoring platform for MT devices. We aimed to evaluate the potential of a DNA-reacting surface to aid the retention of both the main clot and small fragments within the thrombectomy device to improve the potential of MT procedures. METHODS: Device-suitable alloy samples were coated with 15 different compounds and put in contact with extracellular DNA or with human peripheral whole blood, to compare their binding to DNA versus blood elements in vitro. Clinical-grade MT devices were coated with two selected compounds and evaluated in functional bench tests to study clot retrieval efficacy and quantify distal emboli using an M1 occlusion model. RESULTS: Binding properties of samples coated with all compounds were increased for DNA (≈3-fold) and decreased (≈5-fold) for blood elements, as compared with the bare alloy samples in vitro. Functional testing showed that surface modification with DNA-binding compounds improved clot retrieval and significantly reduced distal emboli during experimental MT of large vessel occlusion in a three-dimensional model. CONCLUSION: Our results suggest that clot retrieval devices coated with DNA-binding compounds can considerably improve the outcome of the MT procedures in stroke patients.


Assuntos
Acidente Vascular Cerebral , Trombose , Humanos , Resultado do Tratamento , Trombectomia/métodos , Trombose/terapia , Acidente Vascular Cerebral/cirurgia , Ligas , DNA
20.
J Clin Med ; 12(6)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36983213

RESUMO

(1) Background: Intracranial pressure (ICP) monitoring plays a key role in the treatment of patients in intensive care units, as well as during long-term surgeries and interventions. The gold standard is invasive measurement and monitoring via ventricular drainage or a parenchymal probe. In recent decades, numerous methods for non-invasive measurement have been evaluated but none have become established in routine clinical practice. The aim of this study was to reflect on the current state of research and shed light on relevant techniques for future clinical application. (2) Methods: We performed a PubMed search for "non-invasive AND ICP AND (measurement OR monitoring)" and identified 306 results. On the basis of these search results, we conducted an in-depth source analysis to identify additional methods. Studies were analyzed for design, patient type (e.g., infants, adults, and shunt patients), statistical evaluation (correlation, accuracy, and reliability), number of included measurements, and statistical assessment of accuracy and reliability. (3) Results: MRI-ICP and two-depth Doppler showed the most potential (and were the most complex methods). Tympanic membrane temperature, diffuse correlation spectroscopy, natural resonance frequency, and retinal vein approaches were also promising. (4) Conclusions: To date, no convincing evidence supports the use of a particular method for non-invasive intracranial pressure measurement. However, many new approaches are under development.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA