Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Microvasc Res ; 152: 104630, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38048876

RESUMO

OBJECTIVE: Ischemia/reperfusion can impair microcirculatory blood flow. It remains unknown whether colloids are superior to crystalloids for restoration of microcirculatory blood flow during ischemia/reperfusion injury. We tested the hypothesis that goal-directed colloid - compared to crystalloid - therapy improves small intestinal, renal, and hepatic microcirculatory blood flow in pigs with ischemia/reperfusion injury. METHODS: This was a randomized trial in 32 pigs. We induced ischemia/reperfusion by supra-celiac aortic-cross-clamping. Pigs were randomized to receive either goal-directed isooncotic hydroxyethyl-starch colloid or balanced isotonic crystalloid therapy. Microcirculatory blood flow was measured using Laser-Speckle-Contrast-Imaging. The primary outcome was small intestinal, renal, and hepatic microcirculatory blood flow 4.5 h after ischemia/reperfusion. Secondary outcomes included small intestinal, renal, and hepatic histopathological damage, macrohemodynamic and metabolic variables, as well as specific biomarkers of tissue injury, renal, and hepatic function and injury, and endothelial barrier function. RESULTS: Small intestinal microcirculatory blood flow was higher in pigs assigned to isooncotic hydroxyethyl-starch colloid therapy than in pigs assigned to balanced isotonic crystalloid therapy (768.7 (677.2-860.1) vs. 595.6 (496.3-694.8) arbitrary units, p = .007). There were no important differences in renal (509.7 (427.2-592.1) vs. 442.1 (361.2-523.0) arbitrary units, p = .286) and hepatic (604.7 (507.7-701.8) vs. 548.7 (444.0-653.3) arbitrary units, p = .376) microcirculatory blood flow between groups. Pigs assigned to colloid - compared to crystalloid - therapy also had less small intestinal, but not renal and hepatic, histopathological damage. CONCLUSIONS: Goal-directed isooncotic hydroxyethyl-starch colloid - compared to balanced isotonic crystalloid - therapy improved small intestinal, but not renal and hepatic, microcirculatory blood flow in pigs with ischemia/reperfusion injury. Whether colloid therapy improves small intestinal microcirculatory blood flow in patients with ischemia/reperfusion needs to be investigated in clinical trials.


Assuntos
Objetivos , Traumatismo por Reperfusão , Humanos , Animais , Suínos , Soluções Cristaloides , Microcirculação , Hidratação/métodos , Derivados de Hidroxietil Amido/farmacologia , Derivados de Hidroxietil Amido/uso terapêutico , Isquemia/terapia , Coloides/uso terapêutico , Reperfusão , Soluções Isotônicas/farmacologia , Soluções Isotônicas/uso terapêutico
2.
Langenbecks Arch Surg ; 408(1): 168, 2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37120426

RESUMO

PURPOSE: Postoperative complications after major liver surgery are common. Thoracic epidural anesthesia may provide beneficial effects on postoperative outcome. We strove to compare postoperative outcomes in major liver surgery patients with and without thoracic epidural anesthesia. METHODS: This was a retrospective cohort study in a single university medical center. Patients undergoing elective major liver surgery between April 2012 and December 2016 were eligible for inclusion. We divided patients into two groups according to whether or not they had thoracic epidural anesthesia for major liver surgery. The primary outcome was postoperative hospital length of stay, i.e., from day of surgery until hospital discharge. Secondary outcomes included 30-day postoperative mortality and major postoperative complications. Additionally, we investigated the effect of thoracic epidural anesthesia on perioperative analgesia doses and the safety of thoracic epidural anesthesia. RESULTS: Of 328 patients included in this study, 177 (54.3%) received thoracic epidural anesthesia. There were no clinically important differences in postoperative hospital length of stay (11.0 [7.00-17.0] vs. 9.00 [7.00-14.0] days, p = 0.316, primary outcome), death (0.0 vs. 2.7%, p = 0.995), or the incidence of postoperative renal failure (0.6 vs. 0.0%, p = 0.99), sepsis (0.0 vs. 1.3%, p = 0.21), or pulmonary embolism (0.6 vs. 1.4%, p = 0.59) between patients with or without thoracic epidural anesthesia. Perioperative analgesia doses - including the intraoperative sufentanil dose (0.228 [0.170-0.332] vs. 0.405 [0.315-0.565] µg·kg-1·h-1, p < 0.0001) - were lower in patients with thoracic epidural anesthesia. No major thoracic epidural anesthesia-associated infections or bleedings occurred. CONCLUSION: This retrospective analysis suggests that thoracic epidural anesthesia does not reduce postoperative hospital length of stay in patients undergoing major liver surgery - but it may reduce perioperative analgesia doses. Thoracic epidural anesthesia was safe in this cohort of patients undergoing major liver surgery. These findings need to be confirmed in robust clinical trials.


Assuntos
Analgesia Epidural , Anestesia Epidural , Humanos , Estudos Retrospectivos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Fígado
3.
Microvasc Res ; 143: 104383, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35605693

RESUMO

OBJECTIVE: Spinal cord injury induced by ischemia/reperfusion is a devastating complication of aortic repair. Despite developments for prevention and treatment of spinal cord injury, incidence is still considerably high majorly impacting patient outcome. Microcirculation is paramount for tissue perfusion and oxygen supply and often dissociated from macrohemodynamic parameters used to guide resuscitation. Effects of fluids vs. vasopressors in the setting of hemodynamic resuscitation on spinal cord microperfusion are unknown. Aim of this study was to compare the effects of vasopressor and fluid resuscitation on spinal cord microperfusion in a translational acute pig model of hemorrhagic shock induced ischemia/reperfusion injury. METHODS: We designed this study as prospective randomized explorative large animal study. We induced hemorrhagic shock in 20 pigs as a model of global ischemia/reperfusion injury. We randomized animals to receive either fluid or vasopressor resuscitation. We measured spinal cord microperfusion using fluorescent microspheres as well as laser-Doppler probes. We monitored and analyzed macrohemodynamic parameters and cerebrospinal fluid pressure. RESULTS: Spinal cord microperfusion decreased following hemorrhagic shock induced ischemia/reperfusion injury. Both fluids and vasopressors sufficiently restored spinal cord microperfusion. There were no important changes between groups (percentage changes compared to baseline: fluids 14.0 (0.31-27.6) vs. vasopressors 24.3 (8.12-40.4), p = .340). However, cerebrospinal fluid pressure was higher in animals receiving fluid resuscitation (percentage changes compared to baseline: fluids 27.7 (12.6-42.8) vs. vasopressors -5.56 ((-19.8)-8.72), p = .003). Microcirculatory resuscitation was in line with improvements of macrohemodynamic parameters. CONCLUSIONS: Both, fluids and vasopressors, equally restored spinal cord microperfusion in a porcine acute model of hemorrhagic shock induced ischemia/reperfusion injury. However, significant differences in cerebrospinal fluid pressure following resuscitation were present. Future studies should evaluate these effects in perfusion disruption induced ischemia/reperfusion conditions of microcirculatory deterioration.


Assuntos
Traumatismo por Reperfusão , Choque Hemorrágico , Traumatismos da Medula Espinal , Animais , Isquemia/terapia , Microcirculação , Estudos Prospectivos , Reperfusão , Ressuscitação , Choque Hemorrágico/tratamento farmacológico , Medula Espinal , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/tratamento farmacológico , Suínos
4.
J Anesth ; 35(4): 488-494, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33950295

RESUMO

PURPOSE: Dynamic indicators of preload currently only do reflect preload requirements of the left ventricle. To date, no dynamic indicators of right ventricular preload have been established. The aim of this study was to calculate dynamic indicators of right ventricular preload and assess their ability to predict ventricular volume responsiveness. MATERIALS AND METHODS: The study was designed as experimental trial in 20 anaesthetized pigs. Micro-tip catheters and ultrasonic flow probes were used as experimental reference to enable measurement of right ventricular stroke volume and pulse pressure. Hypovolemia was induced (withdrawal of blood 20 ml/kg) and thereafter three volume-loading steps were performed. ROC analysis was performed to assess the ability of dynamic right ventricular parameters to predict volume response. RESULTS: ROC analysis revealed an area under the curve (AUC) of 0.82 (CI 95% 0.73-0.89; p < 0.001) for right ventricular stroke volume variation (SVVRV), an AUC of 0.72 (CI 95% 0.53-0.85; p = 0.02) for pulmonary artery pulse pressure variation (PPVPA) and an AUC of 0.66 (CI 95% 0.51-0.79; p = 0.04) for pulmonary artery systolic pressure variation (SPVPA). CONCLUSIONS: In our experimental animal setting, calculating dynamic indicators of right ventricular preload is possible and appears promising in predicting volume responsiveness.


Assuntos
Ventrículos do Coração , Hipovolemia , Animais , Pressão Sanguínea , Hidratação , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Volume Sistólico , Suínos , Função Ventricular Direita
5.
Sci Rep ; 11(1): 9215, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33911116

RESUMO

Dynamic parameters of preload have been widely recommended to guide fluid therapy based on the principle of fluid responsiveness and with regard to cardiac output. An equally important aspect is however to also avoid volume-overload. This accounts particularly when capillary leakage is present and volume-overload will promote impairment of microcirculatory blood flow. The aim of this study was to evaluate, whether an impairment of intestinal microcirculation caused by volume-load potentially can be predicted using pulse pressure variation in an experimental model of ischemia/reperfusion injury. The study was designed as a prospective explorative large animal pilot study. The study was performed in 8 anesthetized domestic pigs (German landrace). Ischemia/reperfusion was induced during aortic surgery. 6 h after ischemia/reperfusion-injury measurements were performed during 4 consecutive volume-loading-steps, each consisting of 6 ml kg-1 bodyweight-1. Mean microcirculatory blood flow (mean Flux) of the ileum was measured using direct laser-speckle-contrast-imaging. Receiver operating characteristic analysis was performed to determine the ability of pulse pressure variation to predict a decrease in microcirculation. A reduction of ≥ 10% mean Flux was considered a relevant decrease. After ischemia-reperfusion, volume-loading-steps led to a significant increase of cardiac output as well as mean arterial pressure, while pulse pressure variation and mean Flux were significantly reduced (Pairwise comparison ischemia/reperfusion-injury vs. volume loading step no. 4): cardiac output (l min-1) 1.68 (1.02-2.35) versus 2.84 (2.15-3.53), p = 0.002, mean arterial pressure (mmHg) 29.89 (21.65-38.12) versus 52.34 (43.55-61.14), p < 0.001, pulse pressure variation (%) 24.84 (17.45-32.22) versus 9.59 (1.68-17.49), p = 0.004, mean Flux (p.u.) 414.95 (295.18-534.72) versus 327.21 (206.95-447.48), p = 0.006. Receiver operating characteristic analysis revealed an area under the curve of 0.88 (CI 95% 0.73-1.00; p value < 0.001) for pulse pressure variation for predicting a decrease of microcirculatory blood flow. The results of our study show that pulse pressure variation does have the potential to predict decreases of intestinal microcirculatory blood flow due to volume-load after ischemia/reperfusion-injury. This should encourage further translational research and might help to prevent microcirculatory impairment due to excessive fluid resuscitation and to guide fluid therapy in the future.


Assuntos
Débito Cardíaco , Hemodinâmica , Microcirculação , Traumatismo por Reperfusão/patologia , Volume Sistólico , Animais , Pressão Arterial , Pressão Sanguínea , Feminino , Masculino , Projetos Piloto , Estudos Prospectivos , Curva ROC , Traumatismo por Reperfusão/etiologia , Suínos
6.
J Vis Exp ; (166)2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33369603

RESUMO

Spinal cord injury is a devastating complication of aortic repair. Despite developments for the prevention and treatment of spinal cord injury, its incidence is still considerably high and therefore, influences patient outcome. Microcirculation plays a key role in tissue perfusion and oxygen supply and is often dissociated from macrohemodynamics. Thus, direct evaluation of spinal cord microcirculation is essential for the development of microcirculation-targeted therapies and the evaluation of existing approaches in regard to spinal cord microcirculation. However, most of the methods do not provide real-time assessment of spinal cord microcirculation. The aim of this study is to describe a standardized protocol for real-time spinal cord microcirculatory evaluation using laser-Doppler needle probes directly inserted in the spinal cord. We used a porcine model of ischemia/reperfusion to induce deterioration of the spinal cord microcirculation. In addition, a fluorescent microsphere injection technique was used. Initially, animals were anesthetized and mechanically ventilated. Thereafter, laser-Doppler needle probe insertion was performed, followed by the placement of cerebrospinal fluid drainage. A median sternotomy was performed for exposure of the descending aorta to perform aortic cross-clamping. Ischemia/reperfusion was induced by supra-celiac aortic cross-clamping for a total of 48 min, followed by reperfusion and hemodynamic stabilization. Laser-Doppler Flux was performed in parallel with macrohemodynamic evaluation. In addition, automated cerebrospinal fluid drainage was used to maintain a stable cerebrospinal pressure. After completion of the protocol, animals were sacrificed, and the spinal cord was harvested for histopathological and microsphere analysis. The protocol reveals the feasibility of spinal cord microperfusion measurements using laser-Doppler probes and shows a marked decrease during ischemia as well as recovery after reperfusion. Results showed comparable behavior to fluorescent microsphere evaluation. In conclusion, this new protocol might provide a useful large animal model for future studies using real-time spinal cord microperfusion assessment in ischemia/reperfusion conditions.


Assuntos
Traumatismo por Reperfusão/patologia , Traumatismos da Medula Espinal/patologia , Isquemia do Cordão Espinal/patologia , Medula Espinal/patologia , Animais , Aorta/cirurgia , Modelos Animais de Doenças , Feminino , Hemodinâmica , Masculino , Microcirculação , Medula Espinal/irrigação sanguínea , Suínos
7.
J Clin Monit Comput ; 33(3): 377-384, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30264219

RESUMO

Phenylephrine is an α1-adrenergic receptor agonist widely used to treat perioperative hypotension. Its other hemodynamic effects, in particular on preload and contractility, remain controversial. We, therefore, investigated the effect of continuously applied phenylephrine on central hemodynamics in eight mechanically ventilated domestic pigs. Mean arterial pressure (MAP) was increased in steps by 50%, and 100% using phenylephrine. Besides stroke volume (SV), cardiac output (CO), and MAP, mean systemic vascular resistance (SVR) and dynamic arterial elastance (Eadyn) were assessed for characterization of afterload. Changes in preload were assessed by central venous pressure (CVP), global end-diastolic volume (GEDV), mean systemic filling pressure analog (Pmsfa), pulse pressure variation (PPV), and stroke volume variation (SVV). Further, cardiac function index (CFI), global ejection fraction and dPmax were measured as markers of preload dependent contractility. MAP, SV, and CO significantly increased following both interventions, as did SVR. In contrast, Eadyn did not show significant changes. Although the volumetric preload variable GEDV increased after the first step of phenylephrine, this was not reflected by significant changes in CVP or Pmsfa. CFI and dPmax significantly increased after both steps. Phenylephrine does not only affect cardiac afterload, but also increases effective preload. In contrast to CVP and Pmsfa, this effect can be monitored by GEDV. Further, phenylephrine affects contractility.


Assuntos
Hemodinâmica , Fenilefrina/farmacologia , Animais , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Débito Cardíaco , Pressão Venosa Central , Diástole , Modelos Animais de Doenças , Monitorização Fisiológica , Receptores Adrenérgicos alfa 1/metabolismo , Volume Sistólico , Suínos , Resistência Vascular
8.
Eur J Vasc Endovasc Surg ; 57(2): 284-291, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30309783

RESUMO

OBJECTIVES: In the presence of ischaemia/reperfusion (I/R) induced endothelial injury, volume administration may not correlate with increased microcirculation. The aim of this study was to evaluate intestinal microcirculation after standardised sequential volume loading in an animal model of I/R injury following supracoeliac aortic clamping. METHODS: This was a prospective exploratory pilot animal study. Intestinal I/R injury was induced in eight pigs during experimental thoraco-abdominal aortic repair. After 6 h of I/R, microcirculatory blood flow (mFlux, measured in the ileum using direct laser speckle contrast imaging) and macrohaemodynamic parameters (using trans-cardiopulmonary thermodilution) were measured and measurements were repeated after each of four sequential volume loading steps (VLS1 - 4). Each load was administered over 5 min followed by another 5 min for equilibration. RESULTS: All animals survived until after VLS4. After 6 h of I/R cardiac output (CO) (p < .001) and mFlux (p < .001) had both decreased. CO increased again after VLS1 (p < .001) and VLS2 (p = .036), whereas mFlux did not change. In contrast, mFlux further decreased after VLS3 (p < .01) and VLS4 (p < .001), whereas CO did not change anymore. Extravascular lung water continued to increase after VLS2 (p = .046) and VLS4 (p = .049). CONCLUSIONS: I/R leads to impaired intestinal microcirculation, which was not restored by volume administration in spite of improved CO. In contrast, further volume administration exceeding preload reserves was associated with additional decreases in the intestinal microcirculation. The potentially negative effect of excessive volume resuscitation after I/R injury should encourage further translational research.


Assuntos
Reanimação Cardiopulmonar/métodos , Íleo/irrigação sanguínea , Traumatismo por Reperfusão/complicações , Animais , Modelos Animais de Doenças , Microcirculação , Projetos Piloto , Estudos Prospectivos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA