1.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197908

RESUMO

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Assuntos
Imageamento por Ressonância Magnética , Imãs , Imageamento por Ressonância Magnética/métodos
2.
Magn Reson Med ; 91(4): 1608-1624, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38102807

RESUMO

PURPOSE: MP2RAGE parameter optimization is redefined to allow more time-efficient MR acquisitions, whereas the T1 -based synthetic imaging framework is used to obtain on-demand T1 -weighted contrasts. Our aim was to validate this concept on healthy volunteers and patients with multiple sclerosis, using plug-and-play parallel-transmission brain imaging at 7 T. METHODS: A "time-efficient" MP2RAGE sequence was designed with optimized parameters including TI and TR set as small as possible. Extended phase graph formalism was used to set flip-angle values to maximize the gray-to-white-matter contrast-to-noise ratio (CNR). Several synthetic contrasts (UNI, EDGE, FGATIR, FLAWSMIN , FLAWSHCO ) were generated online based on the acquired T1 maps. Experimental validation was performed on 4 healthy volunteers at various spatial resolutions. Clinical applicability was evaluated on 6 patients with multiple sclerosis, scanned with both time-efficient and conventional MP2RAGE parameterizations. RESULTS: The proposed time-efficient MP2RAGE protocols reduced acquisition time by 40%, 30%, and 19% for brain imaging at (1 mm)3 , (0.80 mm)3 and (0.65 mm)3 , respectively, when compared with conventional parameterizations. They also provided all synthetic contrasts and comparable contrast-to-noise ratio on UNI images. The flexibility in parameter selection allowed us to obtain a whole-brain (0.45 mm)3 acquisition in 19 min 56 s. On patients with multiple sclerosis, a (0.67 mm)3 time-efficient acquisition enhanced cortical lesion visualization compared with a conventional (0.80 mm)3 protocol, while decreasing the scan time by 15%. CONCLUSION: The proposed optimization, associated with T1 -based synthetic contrasts, enabled substantial decrease of the acquisition time or higher spatial resolution scans for a given time budget, while generating all typical brain contrasts derived from MP2RAGE.


Assuntos
Imageamento por Ressonância Magnética , Esclerose Múltipla , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia
3.
Magn Reson Med ; 90(4): 1328-1344, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37246894

RESUMO

PURPOSE: The acquisition of accurate B1 maps is critical for parallel transmit techniques (pTx). The presaturated turboFLASH (satTFL) method has been widely used in combination with interferometric encoding to provide robust and fast B1 maps. However, typical encodings, mostly evaluated on brain, do not necessarily fit all coils and organs. In this work, we evaluated and improved the accuracy of the satTFL for cervical spine at 7 T, proposing a novel interferometric encoding optimization. The benefits of such improvements were investigated in an exploratory study of quantitative T1 mapping with pTx-MP2RAGE. METHODS: Global optimization of interferometric encoding was implemented by simulating the ability of the satTFL to reconstruct B1 maps, with varying encoding and inclusion of complex noise, inside a region of interest covering the cervical spine. The performance of satTFL before and after optimization was compared to actual flip angle imaging. Optimized and non-optimized B1 maps were then used to calculate pTx pulses for MP2RAGE T1 mapping. RESULTS: Interferometric encoding optimization resulted in satTFL closer to actual flip angle imaging, with substantial gain of signal in regions where non-optimized satTFL could fail. T1 maps measured with non-adiabatic pTx pulses were closer to standard non-pTx results (which used adiabatic pulses) when using optimized-satTFL, with substantially lower specific absorption rate. CONCLUSION: Optimization of the satTFL interferometric encoding improves B1 maps in the spinal cord, in particular in low SNR regions. A linear correction of the satTFL was additionally shown to be required. The method was successfully used for quantitative phantom and in vivo T1 mapping, showing improved results compared to non-optimized satTFL thanks to improved pTx-pulse generation.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Medula Espinal/diagnóstico por imagem
4.
Magn Reson Med ; 90(2): 770-783, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36999747

RESUMO

PURPOSE: Optimization of transmit array performance is crucial in ultra-high-field MRI scanners such as 11.7T because of the increased RF losses and RF nonuniformity. This work presents a new workflow to investigate and minimize RF coil losses, and to choose the optimum coil configuration for imaging. METHODS: An 8-channel transceiver loop-array was simulated to analyze its loss mechanism at 499.415 MHz. A folded-end RF shield was developed to limit radiation loss and improve the B 1 + $$ {B}_1^{+} $$ efficiency. The coil element length, and the shield diameter and length were further optimized using electromagnetic (EM) simulations. The generated EM fields were used to perform RF pulse design (RFPD) simulations under realistic constraints. The chosen coil design was constructed to demonstrate performance equivalence in bench and scanner measurements. RESULTS: The use of conventional RF shields at 11.7T resulted in significantly high radiation losses of 18.4%. Folding the ends of the RF shield combined with optimizing the shield diameter and length increased the absorbed power in biological tissue and reduced the radiation loss to 2.4%. The peak B 1 + $$ {B}_1^{+} $$ of the optimal array was 42% more than the reference array. Phantom measurements validated the numerical simulations with a close match of within 4% of the predicted B 1 + $$ {B}_1^{+} $$ . CONCLUSION: A workflow that combines EM and RFPD simulations to numerically optimize transmit arrays was developed. Results have been validated using phantom measurements. Our findings demonstrate the need for optimizing the RF shield in conjunction with array element design to achieve efficient excitation at 11.7T.


Assuntos
Cabeça , Ondas de Rádio , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento , Neuroimagem
5.
Magn Reson Med ; 90(1): 51-63, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36779346

RESUMO

PURPOSE: To optimize the homogeneity of the presaturation module in a Chemical Exchange Saturation Transfer (CEST) acquisition at 7 T using parallel transmission (pTx). THEORY AND METHODS: An optimized pTx-CEST presaturation scheme based on precomputed universal pulses was designed. The optimization was performed by minimizing the L2-norm between the effective B 1 , RMS + $$ {B}_{1,\mathrm{RMS}}^{+} $$ and a given target while imposing energy constraints under virtual observation points (VOPs) supervision. The proposed method was evaluated through simulations and experimentally, both in vitro, on a realistic human head phantom, and in vivo, on healthy volunteers. The results were compared with circular polarization (CP) presaturation and other pTx approaches previously proposed. All experiments were conducted on a 7 T MRI scanner using a commercial 8Tx/32Rx head coil. RESULTS: The simulations show that the proposed pTx strategy boosted with VOPs is superior to the CP mode and existent pTx approaches. While the best results are obtained with subject specific pulses, the gain provided by the use of VOPs renders the universal pulses superior to tailored pulses optimized under vendor provided Specific Absorption Rate (SAR) management. In the phantom, the glucose MTR asym $$ {\mathrm{MTR}}_{\mathrm{asym}} $$ map was significantly more homogeneous than with CP (root mean square error [RMSE] 17% vs. 30%). The efficiency of the method for in vivo hydroxyl, glutamate and rNOE weighted CEST acquisitions was also demonstrated. CONCLUSION: The use of a pTx presaturation scheme based on universal pulses optimized under VOP SAR management is significantly benefiting CEST imaging at high magnetic field.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Voluntários Saudáveis
6.
Neuroimage ; 261: 119498, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35917918

RESUMO

Increased static field inhomogeneities are a burden for human brain MRI at Ultra-High-Field. In particular they cause enhanced Echo-Planar image distortions and signal losses due to magnetic susceptibility gradients at air-tissue interfaces in the subject's head. In the past decade, Multi-Coil Arrays (MCA) have been proposed to shim the field in the brain better than the 2nd or 3rd order Spherical Harmonic (SH) coils usually offered by MRI manufacturers. Here we present a novel MCA, named SCOTCH, optimized for whole brain shimming. Based on a cylindrical structure, it features several layers of small coils whose shape, size and location are found from a principal component analysis of ideal stream functions computed from an internal 100-brain fieldmap database. From an Open-Access external database of 126 brains, our SCOTCH implementation is shown to be equivalent to a partial 7th-order SH system with unlimited power, outperforming all known existing MCA prototypes. This result is further confirmed by a low-cost  30-cm diameter SCOTCH prototype built with 48 coils on 3 layers, and tested on 7 volunteers at 7T with a parallel-transmit RF coil made to be inserted in SCOTCH. Echo-Planar images of the subject brains before and after SCOTCH shimming show large signal recoveries, especially in the prefrontal cortex.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Ondas de Rádio
7.
Magn Reson Med ; 87(6): 2839-2850, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35122302

RESUMO

PURPOSE: In parallel transmission (pTX), subject-tailored RF pulses allow achieving excellent flip angle (FA) accuracy but often require computationally extensive online optimizations, precise characterization of the static field ( ΔB0 ), and the transmit RF field ( B1+ ) distributions. This costs time and requires expertise from the MR user. Universal pulses (UPs) have been proposed to reduce this burden, yet, with a penalty in FA accuracy. This study introduces the concept of standardized universal pulses (SUPs), where pulses are designed offline and adjusted to the subject through a fast online calibration scan. METHODS: A SUP is designed offline using a so-called standardized database, wherein each B1+ map has been normalized to a reference transmit RF field distribution. When scanning a new subject, a 3-slice B1+ acquisition (scan time <10  s) is performed and used to adjust the SUP to the subject through a linear transform. SUP performance was assessed at 7T with simulations by computing the FA-normalized root mean square error (FA-NRMSE) and the FA pattern stability as measured by the average and coefficient of variation of the FA across 15 control subjects, along with in vivo experiments using an MP2RAGE sequence implementing the SUP variant for the FLASH readout. RESULTS: Adjusted SUP improved the FA-NRMSE (8.8 % for UP vs. 7.1 % for adjusted SUP). Experimentally in vivo, this translated in an improved signal homogeneity and more accurate T1 quantification using MP2RAGE. CONCLUSION: The proposed SUP approach improves excitation accuracy (FA-NRMSE) while preserving the same offline pulse design principle as offered by UPs.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Encéfalo , Calibragem , Bases de Dados Factuais , Humanos , Imagens de Fantasmas , Ondas de Rádio
8.
Ann Clin Transl Neurol ; 8(4): 774-789, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33739604

RESUMO

OBJECTIVES: Genetic variant classification is a challenge in rare adult-onset disorders as in SCA-PRKCG (prior spinocerebellar ataxia type 14) with mostly private conventional mutations and nonspecific phenotype. We here propose a refined approach for clinicogenetic diagnosis by including protein modeling and provide for confirmed SCA-PRKCG a comprehensive phenotype description from a German multi-center cohort, including standardized 3D MR imaging. METHODS: This cross-sectional study prospectively obtained neurological, neuropsychological, and brain imaging data in 33 PRKCG variant carriers. Protein modeling was added as a classification criterion in variants of uncertain significance (VUS). RESULTS: Our sample included 25 cases confirmed as SCA-PRKCG (14 variants, thereof seven novel variants) and eight carriers of variants assigned as VUS (four variants) or benign/likely benign (two variants). Phenotype in SCA-PRKCG included slowly progressive ataxia (onset at 4-50 years), preceded in some by early-onset nonprogressive symptoms. Ataxia was often combined with action myoclonus, dystonia, or mild cognitive-affective disturbance. Inspection of brain MRI revealed nonprogressive cerebellar atrophy. As a novel finding, a previously not described T2 hyperintense dentate nucleus was seen in all SCA-PRKCG cases but in none of the controls. INTERPRETATION: In this largest cohort to date, SCA-PRKCG was characterized as a slowly progressive cerebellar syndrome with some clinical and imaging features suggestive of a developmental disorder. The observed non-ataxia movement disorders and cognitive-affective disturbance may well be attributed to cerebellar pathology. Protein modeling emerged as a valuable diagnostic tool for variant classification and the newly described T2 hyperintense dentate sign could serve as a supportive diagnostic marker of SCA-PRKCG.


Assuntos
Proteína Quinase C/genética , Ataxias Espinocerebelares/diagnóstico , Ataxias Espinocerebelares/genética , Ataxias Espinocerebelares/fisiopatologia , Adulto , Idade de Início , Estudos Transversais , Progressão da Doença , Feminino , Humanos , Masculino , Estudos Prospectivos
9.
Magn Reson Med ; 85(2): 1004-1012, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32851654

RESUMO

PURPOSE: To correct with gradient trim blips for gradient delays in bipolar-spoke RF pulses in slice-selective and slab-selective excitations, compatible with tilted acquisitions and anisotropic delays. THEORY: The effect of small gradient delays with respect to RF pulses results in a dephasing of the second RF spoke, proportional to the slab-selection gradient amplitude and the distance of the slice center from the magnet isocenter. Accordingly, adding a trim blip along the corresponding logical gradient axis between the two spokes compensates for the same dephasing, and therefore cancels the gradient delay effects, regardless of position and orientation. METHODS: Gradient delays on different axes were first measured on a 7T system based on an imaging method. Parallel transmission universal bipolar spokes were designed offline to mitigate the RF field inhomogeneity problem in the human brain. Trim blips were used to compensate for the known delays, which was validated with flip angle and temporal SNR measurements on two different volunteers at 7 T. RESULTS: Pulses corrected with trim blips greatly reduced gradient delay effects. Acquisitions made with corrected and noncorrected pulses showed good fidelity with simulations. CONCLUSIONS: Unlike time or phase-shifting approaches, trim blip-based methods apply to all possible bipolar spoke scenarios such as slice excitations, slab excitations, and anisotropy in the gradient delays.


Assuntos
Transtorno Bipolar , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
10.
Magn Reson Med ; 84(6): 3286-3299, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32618387

RESUMO

PURPOSE: Performing simultaneous quantitative MRI at ultrahigh field is challenging, as B0 and B1+ heterogeneities as well as specific absorption rate increase. Too large deviations of flip angle from the target can induce biases and impair SNR in the quantification process. In this work, we use calibration-free parallel transmission, a dedicated pulse-sequence parameter optimization and signal fitting to recover 3D proton density, flip angle, T1 , and T2 maps over the whole brain, in a clinically suitable time. METHODS: Eleven optimized contrasts were acquired with an unbalanced SSFP sequence by varying flip-angle amplitude and RF phase-cycling increment, at a 1.0 × 1.0 × 3.0 mm3 resolution. Acquisition time was 16 minutes 36 seconds for the whole brain. Parallel transmission and universal pulses were used to mitigate B1+ heterogeneity, to improve the results' reliability over 6 healthy volunteers (3 females/3 males, age 22.6 ± 2.7 years old). Quantification of the physical parameters was performed by fitting the acquired contrasts to the simulated ones using the Bloch-Torrey equations with a realistic diffusion coefficient. RESULTS: Whole-brain 3D maps of effective flip angle, proton density, and relaxation times were estimated. Parallel transmission improved the robustness of the results at 7 T. Results were in accordance with literature and with measurements from standard methods. CONCLUSION: These preliminary results show robust proton density, flip angle, T1 , and T2 map retrieval. Other parameters, such as ADC, could be assessed. With further optimization in the acquisition, scan time could be reduced and spatial resolution increased to bring this multiparametric quantification method to clinical research routine at 7 T.


Assuntos
Processamento de Imagem Assistida por Computador , Prótons , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Adulto Jovem
11.
PLoS One ; 14(11): e0225286, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31751410

RESUMO

The simultaneous multi-slice EPI (SMS-EPI, a.k.a. MB-EPI) sequence has met immense popularity recently in functional neuroimaging. A still less common alternative is the use of 3D-EPI, which offers similar acceleration capabilities. The aim of this work was to compare the SMS-EPI and the 3D-EPI sequences in terms of sampling strategies for the detection of task-evoked activations at 7T using detection theory. To this end, the spatial and temporal resolutions of the sequences were matched (1.6 mm isotropic resolution, TR = 1200 ms) and their excitation profiles were homogenized by means of calibration-free parallel-transmission (Universal Pulses). We used a fast-event "localizer" paradigm of 5:20 min in order to probe sensorimotor functions (visual, auditory and motor tasks) as well as higher level functions (language comprehension, mental calculation), where results from a previous large-scale study at 3T (N = 81) served as ground-truth reference for the brain areas implicated in each cognitive function. In the current study, ten subjects were scanned while their activation maps were generated for each cognitive function with the GLM analysis. The SMS-EPI and 3D-EPI sequences were compared in terms of raw tSNR, t-score testing for the mean signal, activation strength and accuracy of the robust sensorimotor functions. To this end, the sensitivity and specificity of these contrasts were computed by comparing their activation maps to the reference brain areas obtained in the 3T study. Estimated flip angle distributions in the brain reported a normalized root mean square deviation from the target value below 10% for both sequences. The analysis of the t-score testing for the mean signal revealed temporal noise correlations, suggesting the use of this metric instead of the traditional tSNR for testing fMRI sequences. The SMS-EPI and 3D-EPI thereby yielded similar performance from a detection theory perspective.


Assuntos
Encéfalo/fisiologia , Imagem Ecoplanar , Imageamento por Ressonância Magnética , Adulto , Mapeamento Encefálico/métodos , Imagem Ecoplanar/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Curva ROC , Sensibilidade e Especificidade , Razão Sinal-Ruído , Adulto Jovem
12.
Magn Reson Med ; 82(6): 2016-2031, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31257612

RESUMO

PURPOSE: A calibration-free pulse design method is introduced to alleviate B1+ artifacts in clinical routine with parallel transmission at high field, dealing with significant inter-subject variability, found for instance in the abdomen. THEORY AND METHODS: From a dual-transmit 3T scanner, a database of B1+ and off-resonance abdominal maps from 50 subjects was first divided into 3 clusters based on mutual affinity between their respective tailored kT -points pulses. For each cluster, a kT -points pulse was computed, minimizing normalized root-mean-square flip angle deviations simultaneously for all subjects comprised in it. Using 30 additional subjects' field distributions, a machine learning classifier was trained on this 80-labeled-subject database to recognize the best pulse from the 3 ones available, relying only on patient features accessible from the preliminary localizer sequence present in all protocols. This so-called SmartPulse process was experimentally tested on an additional 53-subject set and compared with other pulse types: vendor's hard calibration-free dual excitation, tailored static radiofrequency shimming, universal and tailored kT -points pulses. RESULTS: SmartPulse outperformed both calibration-free approaches. Tailored static radiofrequency shimming yielded similar flip angle homogeneity for most patients but broke down for some while SmartPulse remained robust. Although flip angle homogeneity was systematically better with tailored kT -points, the difference was barely noticeable on in vivo images. CONCLUSION: The proposed method paves the way toward an efficient trade-off between tailored and universal pulse design approaches for large inter-subject variability. With no need for on-line field mapping or pulse design, it can fit seamlessly into a clinical protocol.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Ondas de Rádio , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Índice de Massa Corporal , Calibragem , Análise por Conglomerados , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
13.
Metab Brain Dis ; 34(4): 1071-1076, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31089866

RESUMO

Hepatic encephalopathy (HE) is a frequent and debilitating complication of cirrhosis and its pathogenesis is not definitively clarified. Recent hypotheses focus on the possible existence of low-grade cerebral edema due to accumulation of osmolytes secondary to hyperammonemia. In the present study we investigated increases in cerebral water content by a novel magnetic resonance impedance (MRI) technique in cirrhosis patients with and without clinically manifest HE. We used a 3 T MRI technique for quantitative cerebral water content mapping in nine cirrhosis patients with an episode of overt HE, ten cirrhosis patients who never suffered from HE, and ten healthy aged-matched controls. We tested for differences between groups by statistical non-parametric mapping (SnPM) for a voxel-based spatial evaluation. The patients with HE had significantly higher water content in white matter than the cirrhosis patients (0.6%), who in turn, had significantly higher content than the controls (1.7%). Although the global gray matter water content did not differ between the groups, the patients with HE had markedly higher thalamic water content than patients who never experienced HE (6.0% higher). We found increased white matter water content in cirrhosis patients, predominantly in those with manifest HE. This confirms the presence of increasing degrees of low-grade edema with exacerbation of pathology. The thalamic edema in manifest HE may lead to compromised basal ganglia-thalamo-cortical circuits, in accordance with the major clinical symptoms of HE. The identification of the thalamus as particularly inflicted in manifest HE is potentially relevant to the pathophysiology of HE.


Assuntos
Edema Encefálico/patologia , Encéfalo/patologia , Encefalopatia Hepática/patologia , Cirrose Hepática/patologia , Água , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Edema Encefálico/diagnóstico por imagem , Feminino , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Encefalopatia Hepática/diagnóstico por imagem , Humanos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Adulto Jovem
14.
Magn Reson Med ; 82(4): 1518-1526, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31095776

RESUMO

PURPOSE: To investigate the correlation between electrical conductivity and sodium concentration, both measured in vivo, in the human brain. METHODS: Conductivity measurements were performed on samples with different sodium (Na+ ) and agarose concentrations using a dielectric probe, and the correlation between conductivity and Na+ content was evaluated. Subsequently, brain conductivity and total Na+ content maps were measured in 8 healthy subjects using phase-based MREPT and sodium MRI, respectively. After co-registration and spatial normalization to the 1 mm 152 MNI brain atlas, the relationship between conductivity and tissue sodium concentration (TSC) was examined within different brain regions. RESULTS: The conductivities of agarose gels increased linearly with NaCl concentration, while remaining almost independent of agarose content. When measured in healthy subjects, conductivities showed positive correlation with total tissue sodium concentration (R = 0.39, P < 0.005). The same trend was found in gray matter (R = 0.36, P < 0.005) and in white matter (R = 0.28, P < 0.05). CONCLUSION: Tissue conductivity shows a positive correlation with total sodium concentration. Conductivity might serve as a novel technique to visualize the total tissue electrolyte concentration, although refinements in the consideration of e.g., tissue water content, would be necessary to improve the quantitative value.


Assuntos
Química Encefálica/fisiologia , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sódio/química , Adulto , Encéfalo/fisiologia , Condutividade Elétrica , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Rede Nervosa/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
15.
Magn Reson Imaging ; 61: 104-115, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108151

RESUMO

PURPOSE: To demonstrate that fast-kz spokes can be used in parallel transmission to homogenize flip angle ramp profiles (known as TONE) in slab selections, and thereby improve Time-Of-Flight angiography of the whole human brain at 7T. METHODS: B1+ and B0 maps were measured on seven human brains with a z-segmented coil connected to an 8-channel pTx system. Tailored two-spoke pulses were designed under strict hardware and SAR constraints for uniform slab profile before transforming their subpulse waveforms for linearly-increasing flip-angle ramps. Increasing angulations along the feet-head direction were prescribed in 2-slab and 3-slab TOF acquisitions. Excitation patterns were simulated and compared with RF-shimmed (single spoke) ramp pulses. Excitation performances were assessed in ~10-min TOF acquisitions by visually inspecting Maximal Intensity Projections angiograms. RESULTS: The flip-angle ramp fidelity achieved by double spokes inside slabs of interest was improved by 30-40% compared to RF-shimmed ramps. This allowed better homogenizing signal along arteries, and depicting small vessels in distal areas of the brain, in comparison with RF-shimmed ramp pulses or double-spoke uniform excitation. CONCLUSION: Ramp double spokes used in conjunction with parallel transmission yield better blood saturation compensation and more finely resolved TOF angiograms than mere double spokes or ramp single spokes at 7T.


Assuntos
Artérias/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia por Ressonância Magnética , Adulto , Algoritmos , Artérias Carótidas/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Modelos Estatísticos , Tempo , Adulto Jovem
16.
Neuroimage ; 195: 1-10, 2019 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-30923027

RESUMO

The Human Connectome Project (HCP) has a 7T component that aims to study the human brain's organization and function with high spatial and temporal resolution fMRI and diffusion-weighted acquisitions. For whole brain applications at 7T, a major weakness however remains the heterogeneity of the radiofrequency transmission field (B1+ ), which prevents from achieving an optimal signal and contrast homogeneously throughout the brain. In this work, we use parallel transmission (pTX) Universal Pulses (UP) to improve the flip angle homogeneity and demonstrate their application to highly accelerated multi-band EPI (MB5 and GRAPPA2, as prescribed in the 7T HCP protocol) sequence, but also to acquire at 7T B1+ -artefact-free T1 - and T2 -weighted anatomical scans used in the pre-processing pipeline of the HCP protocol. As compared to typical implementations of pTX, the proposed solution is fully operator-independent and allows "plug and play" exploitation of the benefits offered by multi-channel transmission. Validation in five healthy adults shows that the proposed technique achieves a flip angle homogeneity comparable to that of a clinical 3 T system. Compared to standard single-channel transmission, the use of UPs at 7T yielded up to a two-fold increase of the temporal signal-to-noise ratio in the temporal lobes as well as improved detection of functional connectivity in the brain regions most strongly affected by B1+ inhomogeneity.


Assuntos
Encéfalo/fisiologia , Conectoma/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Imagem Ecoplanar/métodos , Feminino , Humanos , Masculino , Descanso/fisiologia
17.
Magn Reson Med ; 81(5): 3202-3208, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30652352

RESUMO

PURPOSE: The fluid attenuated inversion recovery sequence is a pillar technique to detect brain lesions in MRI. At ultrahigh field, the lengthening of T1 often advocates a T2 -weighting preparation module to regain signal and contrast between tissues, which can be affected by transmit RF field inhomogeneity. In this note, we report an extension of a previous fluid attenuated inversion recovery study that now incorporates the T2 preparation with parallel transmission calibration-free universal pulses to mitigate the problem. METHODS: The preparation consisted of a 90°-τ-180° -τ-90° module to implement an effective inversion in the CSF and a saturation in the brain tissues. Care was taken for the pulses to have the desired phase relationship in every voxel by appropriate pulse design. The RF pulse design made use of the kT -point parametrization and was based on a database of 20 B1+ and ΔB0 maps previously acquired on different subjects at 7 T. Simulations and experiments on 5 volunteers, not contained in the database, were performed for validation. RESULTS: Simulations reported very good inversion efficiency for the preparation module with 8% variation, with respectively 4 and 6 times less power and specific absorption rate than for the adiabatic version. Experiments revealed fluid attenuated inversion recovery images free of B1+ artifacts. CONCLUSION: This work contributes further to the panel of 3D sequences validated and now available with universal pulses at 7 T. The drop in power and specific absorption rate demand compared with adiabatic pulses in the T2 preparation leads to more freedom for the design of the readout train.


Assuntos
Encefalopatias/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Algoritmos , Artefatos , Calibragem , Líquido Cefalorraquidiano , Simulação por Computador , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Esclerose Múltipla/líquido cefalorraquidiano , Imagens de Fantasmas , Razão Sinal-Ruído
18.
Front Neurol ; 10: 1333, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31920951

RESUMO

Water concentration is tightly regulated in the healthy human brain and changes only slightly with age and gender in healthy subjects. Consequently, changes in water content are important for the characterization of disease. MRI can be used to measure changes in brain water content, but as these changes are usually in the low percentage range, highly accurate and precise methods are required for detection. The method proposed here is based on a long-TR (10 s) multiple-echo gradient-echo measurement with an acquisition time of 7:21 min. Using such a long TR ensures that there is no T1 weighting, meaning that the image intensity at zero echo time is only proportional to the water content, the transmit field, and to the receive field. The receive and transmit corrections, which are increasingly large at higher field strengths and for highly segmented coil arrays, are multiplicative and can be approached heuristically using a bias field correction. The method was tested on 21 healthy volunteers at 3T field strength. Calibration using cerebral-spinal fluid values (~100% water content) resulted in mean values and standard deviations of the water content distribution in white matter and gray matter of 69.1% (1.7%) and 83.7% (1.2%), respectively. Measured distributions were coil-independent, as seen by using either a 12-channel receiver coil or a 32-channel receiver coil. In a test-retest investigation using 12 scans on one volunteer, the variation in the mean value of water content for different tissue types was ~0.3% and the mean voxel variability was ~1%. Robustness against reduced SNR was assessed by comparing results for 5 additional volunteers at 1.5T and 3T. Furthermore, water content distribution in gray matter is investigated and regional contrast reported for the first time. Clinical applicability is illustrated with data from one stroke patient and one brain tumor patient. It is anticipated that this fast, stable, easy-to-use, high-quality mapping method will facilitate routine quantitative MR imaging of water content.

19.
J Magn Reson Imaging ; 47(6): 1562-1571, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29159855

RESUMO

BACKGROUND: The excitation inhomogeneity artifact occurring at 3T in the abdomen can lead to dramatic loss of signal and contrast, thereby hampering diagnosis. PURPOSE: To assess excitation homogeneity and image quality achieved by nonselective prototypical kT -points pulses, compared to tailored static RF shimming, in clinical routine on a commercial dual-transmit scanner. STUDY TYPE: Retrospective study with Institutional Review Board approval; informed consent was waived. POPULATION: Fifty consecutive patients referred for liver MRI at a single hospital. FIELD STRENGTH/SEQUENCE: 3D breath-hold dynamic contrast-enhanced (DCE) MRI at 3T. ASSESSMENT: Flip angle homogeneity was estimated via numerical simulation based on measured static and RF field maps. In all, 20 of the 50 patients underwent DCE-MRI while a pulse designer was present. The effect of RF shimming and kT -point pulses could be compared by repeating the acquisition with each transmit scheme before injection and in the late phase. Signal homogeneity, T1 contrast, enhancement quality, structure details, and global image quality were assessed on a 4-level scale (0 to 3) by two radiologists. STATISTICAL TESTS: Means were compared using Wilcoxon signed-rank tests. RESULTS: Normalized root mean square flip angle error was significantly reduced with kT -points compared to static RF shimming (8.5% ± 1.5% [mean ± standard deviation, SD] vs. 20.4% ± 9.8%; P < 0.0001). The worst case (heavy ascites) led to 13.0% (kT -points) vs. 54.9% (RF shimming). Global image quality was significantly higher for kT -points (2.3 ± 0.5 vs. 1.9 ± 0.6; P = 0.008). One subject's examination was judged unusable with RF shimming by one reader, none with kT -points. 85% of kT -points acquisitions were graded at least 2/3, and only 55% for static RF shimming. DATA CONCLUSION: KT -points reduce excitation inhomogeneity quantitatively and qualitatively, especially in patients with ascites and prone to B1 shading. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1562-1571.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Ascite/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Adulto Jovem
20.
Magn Reson Med ; 80(1): 53-65, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193250

RESUMO

PURPOSE: T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, universal pulses were recently demonstrated to save precious time and computational efforts by skipping B1 calibration and online RF pulse tailoring. Here, we report a universal RF pulse design for non-selective refocusing pulses to mitigate the RF inhomogeneity problem at 7T in turbo spin-echo sequences with variable flip angles. METHOD: Average Hamiltonian theory was used to synthetize a single non-selective refocusing pulse with pTx while optimizing its scaling properties in the presence of static field offsets. The design was performed under explicit power and specific absorption rate constraints on a database of 10 subjects using a 8Tx-32Rx commercial coil at 7T. To validate the proposed design, the RF pulses were tested in simulation and applied in vivo on 5 additional test subjects. RESULTS: The root-mean-square rotation angle error (RA-NRMSE) evaluation and experimental data demonstrated great improvement with the proposed universal pulses (RA-NRMSE ∼8%) compared to the standard circularly polarized mode of excitation (RA-NRMSE ∼26%). CONCLUSION: This work further completes the spectrum of 3D universal pulses to mitigate RF field inhomogeneity throughout all 3D MRI sequences without any pTx calibration. The approach returns a single pulse that can be scaled to match the desired flip angle train, thereby increasing the modularity of the proposed plug and play approach. Magn Reson Med 80:53-65, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Adulto , Algoritmos , Aorta/patologia , Mapeamento Encefálico/métodos , Calibragem , Simulação por Computador , Meios de Contraste , Bases de Dados Factuais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Adulto Jovem