Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Mil Med ; 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38850224

RESUMO

INTRODUCTION: Operating room fires can have devastating consequences and as such must be prevented. There exists a paucity of literature requiring further elucidation regarding manufacturer recommendations of a predefined waiting period prior to patient draping after using alcohol-based surgical antiseptics, in order to reduce the risk of operating room fires. METHODS: This was further investigated by exposing two common alcohol-based surgical antiseptics to electrosurgery and open flames at various power settings and time intervals in an ex vivo porcine model. The simulated surgical site was prepped following manufacturer recommendations and exposed to monopolar electrosurgery at low and high power, using both PURE CUT and COAGULATION modes, and open flame, at 15-s increments after application. RESULTS: While using PURE CUT mode at both low and high power, no ignition was observed on hairless surgical sites prepped with ChloraPrep® at any time point. However, use of COAGULATION mode at both low and high powers resulted in ignition consistently out to 1-min post-application. Additionally, if the prepped area subjectively appeared wet, especially with pooling of the antiseptic, both COAGULATION mode and open flame caused ignition. Dry time was found to be about 59 s for both prep solutions. It was also observed that the amount of pressure directly correlated with the amount of prep dispersed and increased dry times. CONCLUSION: In conclusion, our data suggest an average dry time of less than 1-min, with ignition only observed when the antiseptic was visibly wet. Ignition did not occur on hairless skin with electrocautery on CUT mode using ChloraPrep at any time point. Additionally, ignition on hair-bearing skin was not observed past 3 min, with current manufacturer recommendations stating 1 h wait time for hair-bearing skin. Arbitrarily waiting a specific predetermined dry time until patient draping, as recommended by the manufacturers, may be unnecessary and lead to hours' worth of time wasted each year. Ongoing research will further investigate the utility of drying the antiseptic after application and its affect on not only preventing ignition but also antimicrobial efficacy.

2.
BMJ Case Rep ; 17(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479827

RESUMO

Castleman disease (CD) is a rare, benign lymphoproliferative disorder with characteristic histopathological features, but variable aetiology, presentation, treatment and prognosis. It is broadly classified based on its location and histopathological features, with unicentric hyaline vascular disease presenting most commonly. We present a case of primary, unicentric hepatic CD that was incidentally found on imaging and managed with laparoscopic resection.


Assuntos
Hiperplasia do Linfonodo Gigante , Transtornos Linfoproliferativos , Humanos , Hiperplasia do Linfonodo Gigante/diagnóstico por imagem , Hiperplasia do Linfonodo Gigante/cirurgia , Prognóstico
3.
BMJ Case Rep ; 17(3)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538095

RESUMO

Infectious aortitis is a rare disease process which can be of fungal, viral or bacterial aetiology. This disease process is often incidentally found during concomitant infectious processes, likely due to haematogenous spread. Common sources are from cardiac, genitourinary and gastroenterologic sources. CT imaging of the aorta is essential in identifying physiological changes-wall thickness changes, ectasia and stenosis. We present a case of a female in her early 60s with a medical history of cardiomyopathy with heart failure and reduced ejection fraction, who was initially admitted for acute cholecystitis complicated by the development of gallstone pancreatitis. Imaging evaluation incidentally noted findings consistent with aortitis with a penetrating ulcer, and blood cultures were positive for Staphylococcus aureus bacteraemia, confirming her diagnosis of infectious aortitis. She was started on intravenous antibiotics, required preoperative nutritional optimisation, and subsequently underwent an open aortic resection and aortoiliac reconstruction with rifampin-soaked Dacron graft.


Assuntos
Aortite , Bacteriemia , Infecções dos Tecidos Moles , Infecções Estafilocócicas , Estados Unidos , Humanos , Feminino , Aortite/diagnóstico , Aortite/terapia , Aortite/complicações , Bacteriemia/complicações , Hospitais Militares , Infecções Estafilocócicas/complicações , Staphylococcus aureus , Infecções dos Tecidos Moles/complicações
4.
Knee ; 41: 106-114, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36642034

RESUMO

BACKGROUND: Tibial footprint of anterior cruciate ligament (ACL) is situated close to the anterior lateral meniscal root (ALMR) attachment. PURPOSE: To investigate the impact of the size and location of the tibial tunnel for ACL reconstruction on the ACL footprint coverage and overlap to the ALMR. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty knee MRI scans from twenty healthy subjects were recruited, and three-dimensional (3D) tibia models were created to show the tibial attachment sites of ACL and ALMR. Surgical simulation of the tibial tunnel drilling was performed on each 3D model, entering the joint at an angle set at 60 degrees from the tibial plateau plane and 55 degrees from the posterior tibial condylar axis, with analysis for six different drill sizes; 7.5, 8, 8.5, 9, 9.5 and 10 mm; and nine locations; the center of the ACL attachment and eight locations 2% of the tibial width apart surrounding it. The width of the tibial plateau, the distance between ACL and ALMR attachment centers, and the size and location of the potential tibial tunnel were evaluated to determine association with the area of the ACL footprint coverage and ALMR overlap using a linear mixed effects model. RESULTS: A large tunnel (p <.001), a central and anterior location (p <.029), and small tibial width (p =.015) were all associated with larger coverage of the ACL footprint. A large tunnel (p <.001), posteriorly and laterally located (p ≤ 0.001), and a small distance between the ACL and ALMR centers (p =.001) were significantly associated with a larger ALMR overlap. The association of the tunnel size to ALMR overlap reduced with a medial tunnel location. CONCLUSIONS: The short distance between the centers of the ALMR attachment and native ACL footprint suggests that the ALMR will always be susceptible to overlap when the tibial tunnel is drilled in ACL reconstruction. Small alterations in tunnel location can lead to a statistically significant alteration with the amount of ALMR overlap. To minimize this overlap, whilst maintaining acceptable coverage of the ACL footprint, a tibial tunnel positioned in a medial or anteromedial location from the center of the ACL footprint is recommended.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Cadáver , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Imageamento por Ressonância Magnética , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Fêmur/cirurgia
5.
J Robot Surg ; 17(2): 413-417, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35739435

RESUMO

The purpose of this study is to update the available literature with information on the current use of robotic assisted surgery (RAS) in the Department of Defense (DoD) compared to the civilian world, and how the coronavirus disease 2019 (COVID-19) pandemic impacted RAS in the DoD. A total of 9,979 RAS cases between 01st October 2017 and 31st December 2020 were reviewed from every DoD Military Treatment Facility (MTF) that meets our inclusion criteria and employs various models of da Vinci robotic surgical systems (Intuitive Surgical). Specialty, number, and facility were recorded for each case. These data were then compared to previously known trends about RAS use in the DoD as well as with civilian trends. Before COVID-19, the use of RAS had increased over time, but not at the same rate as in the civilian sector. General surgery cases constituted most RAS cases in both the DoD and the civilian sector. The arrival of COVID-19 in the United States significantly decreased the use of RAS in the DoD as well as in the civilian sector in all surgical specialties because it led to postponement or cancellation of many non-emergent surgical procedures. In conclusion, the use of RAS has continued to increase, and general surgery cases continue to constitute most of these cases. However, since the COVID-19 pandemic began, there was a significant decline in both DoD and civilian RAS cases, with a more pronounced decline in the DoD.


Assuntos
COVID-19 , Procedimentos Cirúrgicos Robóticos , Especialidades Cirúrgicas , Humanos , Estados Unidos , Procedimentos Cirúrgicos Robóticos/métodos , Pandemias
6.
Surg Endosc ; 37(7): 5570-5575, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36315283

RESUMO

BACKGROUND: Endoscopy is performed routinely during bariatric surgery. It is often used for provocative testing and intraluminal inspection during Roux-en-Y gastric bypass (RNYGB) and sleeve gastrectomy (SG). Recent publications would indicate about one-quarter of bariatric cases are performed with concurrent endoscopy, resulting in a slight increase in time but no increase in complications within 30 days compared with cases where no endoscopy is performed. Do these results persist for endoscopy during revisional bariatric surgery (RBS)? METHODS: An analysis of the American College of Surgeons National Surgical Quality Initiative Program (NSQIP) was conducted for the years 2005-2017. Seventeen postoperative outcomes were analyzed in this database. A 1:1 propensity score matching analysis was completed for 13 patient comorbidities and demographics. A McNemar's test for paired categorical variables and a paired t-test for continuous variables were completed, with a significant P value of 0.05. The results were reported as the frequency and percentage for categorical variables and the mean (± standard deviation) for continuous variables. RESULTS: A total of 7249 RBS cases were identified. After propensity score matching for patient comorbidities and demographics 2329 cases remained. Esophagogastroduodenoscopy (EGD) was performed in 375 (16%) of these patients. There were no differences in complication rates between the two groups. CONCLUSIONS: Similar to non-revisional bariatric surgery, there is no difference in 30-day postoperative complications when endoscopy is performed in RBS. Endoscopy is performed in about one-sixth of RBS cases.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Reoperação/métodos , Cirurgia Bariátrica/efeitos adversos , Cirurgia Bariátrica/métodos , Derivação Gástrica/efeitos adversos , Derivação Gástrica/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Endoscopia Gastrointestinal/efeitos adversos , Obesidade Mórbida/cirurgia , Obesidade Mórbida/complicações , Estudos Retrospectivos , Gastrectomia/métodos , Resultado do Tratamento , Laparoscopia/efeitos adversos
7.
Am J Sports Med ; 50(8): 2102-2110, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35612835

RESUMO

BACKGROUND: An increase has been seen in the number of studies of anterior cruciate ligament reconstruction (ACLR) that use magnetic resonance imaging (MRI) as an outcome measure and proxy for healing and integration of the reconstruction graft. Despite this, the MRI appearance of a steady-state graft and how long it takes to achieve such an appearance have not yet been established. PURPOSE: To establish whether a hamstring tendon autograft for ACLR changes in appearance on MRI scans between 1 and 2 years and whether this change affects a patient's ability to return to sports. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Patients with hamstring tendon autograft ACLR underwent MRI and clinical outcome measures at 1 year and at a final follow-up of at least 2 years. MRI graft signal was measured at multiple regions of interest using oblique reconstructions both parallel and perpendicular to the graft, with lower signal indicative of better healing and expressed as the signal intensity ratio (SIR). Changes in tunnel aperture areas were also measured. Clinical outcomes were side-to-side anterior laxity and patient-reported outcome measures (PROMs). RESULTS: A total of 42 patients were included. At 1 year, the mean SIR for the graft was 2.7 ± 1.2. Graft SIR of the femoral aperture was significantly higher than that of the tibial aperture (3.4 ± 1.3 vs 2.6 ± 1.8, respectively; P = .022). Overall, no significant change was seen on MRI scans after 2 years; a proximal graft SIR of 1.9 provided a sensitivity of 96% to remain unchanged. However, in the 6 patients with the highest proximal graft SIR (>4) at 1 year, a significant reduction in signal was seen at final follow-up (P = .026), alongside an improvement in sporting level. A significant reduction in aperture area was also seen between 1 and 2 years (tibial, -6.3 mm2, P < .001; femoral, -13.3 mm2, P < .001), which was more marked in the group with proximal graft SIR >4 at 1 year and correlated with a reduction in graft signal. The patients had a high sporting level; the median Tegner activity score was 6 (range, 5-10), and a third of patients scored either 9 or 10. Overall, PROMs and knee laxity were not associated with MRI appearance. CONCLUSION: In the majority of patients, graft SIR on MRI did not change significantly after 1 year, and a proximal graft SIR <2 was a sensitive indicator for a stable graft signal, implying healing. Monitoring is proposed for patients who have a high signal at 1 year (proximal graft SIR >4), because a significant reduction in signal was seen in the second year, indicative of ongoing healing, alongside an improvement in sporting level. A reduction in tunnel aperture area correlated with a reduction in graft SIR, suggesting this could also be a useful measure of graft integration.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Tendões dos Músculos Isquiotibiais , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Autoenxertos/cirurgia , Tendões dos Músculos Isquiotibiais/transplante , Humanos , Articulação do Joelho/cirurgia , Escore de Lysholm para Joelho , Imageamento por Ressonância Magnética , Transplante Autólogo
8.
Surg Obes Relat Dis ; 18(5): 658-665, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35248482

RESUMO

BACKGROUND: Two large nationwide databases collect data on common operations in the United States. The Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP) collects bariatric data, whereas the National Quality Improvement Program (NSQIP) gathers details on a broader range of general surgical cases. OBJECTIVE: Evaluate the differences in rates of complications between both databases regarding Roux-en-Y gastric bypass and sleeve gastrectomy. SETTING: National databases, United States. METHODS: We evaluated the MBSAQIP and NSQIP from 2017 to 2019 using the procedure codes 43644 and 43775. Fifteen common complications were evaluated. Propensity-matched analyses (PMAs) were done to control for differences across databases. Significantly different variables after a PMA were included in multivariable models. The data were examined for differences between the 2 databases before and after the PMA, with and without adjustment for operation type. RESULTS: There were 483,361 cases reported in the MBSAQIP and 57,598 in the NSQIP. PMA matched 57,479 cases for each database. Seven complications were different, with higher rates reported in the NSQIP than in the MBSAQIP: myocardial infarction, sepsis, organ/space surgical site infections, deep vein thrombosis, urinary tract infections, pulmonary embolism, ventilator dependence >48 hours, and pneumonia. When adjusting for the procedure performed, sleeve gastrectomy in the NSQIP had higher rates of organ/space surgical site infections, deep vein thrombosis, sepsis, and death. Roux-en-Y gastric bypass in the NSQIP had higher rates of organ/space surgical site infections, ventilator dependence >48 hours, urinary tract infections, myocardial infarction, deep vein thrombosis, and sepsis. CONCLUSION: When compared with the MBSAQIP, the NSQIP reports higher rates of bariatric complications. Further studies are needed to confirm the reasons behind this.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Infarto do Miocárdio , Obesidade Mórbida , Sepse , Trombose Venosa , Acreditação , Cirurgia Bariátrica/métodos , Gastrectomia/métodos , Derivação Gástrica/métodos , Humanos , Infarto do Miocárdio/complicações , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Melhoria de Qualidade , Estudos Retrospectivos , Sepse/cirurgia , Infecção da Ferida Cirúrgica , Resultado do Tratamento , Estados Unidos/epidemiologia , Trombose Venosa/complicações
9.
J ISAKOS ; 6(2): 66-73, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33832979

RESUMO

OBJECTIVES: Given the common occurrence of residual laxity and re-injury post anterior cruciate ligament reconstruction (ACLR), additional anterolateral procedures are increasingly used in combination with an ACLR. Despite the perception that there is a risk of over-constraining the lateral tibiofemoral (LTF) compartment, potentially leading to osteoarthritis, assessment on their effect on intra-articular compartment pressures is still lacking. Our objective was therefore, through a pilot biomechanical study, to compare LTF contact pressures after the most commonly used anterolateral procedures. METHODS: A controlled laboratory pilot study was performed using 4 fresh-frozen cadaveric whole lower limbs. Through 0° to 90° of flexion, LTF contact pressures were measured with a Tekscan sensor, located under the lateral meniscus. Knee kinematics were obtained in 3 conditions of rotation (NR: neutral, ER: external and IR: internal rotation) to record the position of the knees for each loading condition. A Motion Analysis system with a coordinate system based on CT scans 3D bone modelling was used. After an ACLR, defined as the reference baseline, 5 anterolateral procedures were compared: anterolateral ligament reconstruction (ALLR), modified Ellison, deep Lemaire, superficial Lemaire and modified MacIntosh procedures. The last 3 procedures were randomised. For each procedure, the graft was fixed in NR at 30° of flexion and with a tension of 20 N. RESULTS: Compared with isolated ACLR, addition of either ALLR or modified Ellison procedure did not increased the overall LTF contact pressure (all p>0.05) through the full range of flexion for the IR condition. Conversely, deep Lemaire, superficial Lemaire and modified MacIntosh procedure (all p<0.05) did increase the overall LTF contact pressure compared with ACLR in IR. No significant difference was observed in ER and NR conditions. CONCLUSION: This pilot study, comparing the main anterolateral procedures, revealed that addition of either ALLR or modified Ellison procedure did not change the overall contact pressure in the LTF compartment through 0° to 90° of knee flexion. In contrast, the deep and superficial Lemaire, and modified MacIntosh procedures significantly increased overall LTF contact pressures when the knee was internally rotated.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamentos Articulares/cirurgia , Tenodese/métodos , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Ligamentos Articulares/fisiopatologia , Projetos Piloto , Pressão , Amplitude de Movimento Articular , Rotação
10.
J ISAKOS ; 6(2): 74-81, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33832980

RESUMO

OBJECTIVE: The optimal anterolateral procedure to control anterolateral rotational laxity of the knee is still unknown. The objective was to compare the ability of five anterolateral procedures performed in combination with anterior cruciate ligament reconstruction (ACLR) to restore native knee kinematics in the setting of a deficient anterior cruciate ligament (ACL) and anterolateral structures. METHODS: A controlled laboratory study was performed using 10 fresh-frozen cadaveric whole lower limbs with intact iliotibial band. Kinematics from 0° to 90° of flexion were recorded using a motion analysis three-dimensional (3D) optoelectronic system, allowing assessment of internal rotation (IR) and anteroposterior (AP) tibial translation at 30° and 90° of flexion. Joint centres and bony landmarks were calculated from 3D bone models obtained from CT scans. Intact knee kinematics were assessed initially, followed by sequential section of the ACL and anterolateral structures (anterolateral ligament, anterolateral capsule and Kaplan fibres). After ACLR, five anterolateral procedures were performed consecutively on the same knee: ALLR, modified Ellison, deep Lemaire, superficial Lemaire and modified MacIntosh. The last three procedures were randomised. For each procedure, the graft was fixed in neutral rotation at 30° of flexion and with a tension of 20 N. RESULTS: Isolated ACLR did not restore normal overall knee kinematics in a combined ACL plus anterolateral-deficient knee, leaving a residual tibial rotational laxity (p=0.034). Only the ALLR (p=0.661) and modified Ellison procedure (p=0.641) restored overall IR kinematics to the normal intact state. Superficial and deep Lemaire and modified MacIntosh tenodeses overconstrained IR, leading to shifted and different kinematics compared with the intact condition (p=0.004, p=0.001 and p=0.045, respectively). Compared with ACLR state, addition of an anterolateral procedure did not induce any additional control on AP translation at 30° and 90° of flexion (all p>0.05), except for the superficial Lemaire procedure at 90° (p=0.032). CONCLUSION: In biomechanical in vitro setting, a comparison of five anterolateral procedures revealed that addition of either ALLR or modified Ellison procedure restored overall native knee kinematics in a combined ACL plus anterolateral-deficient knee. Superficial and deep Lemaire and modified MacIntosh tenodeses achieved excellent rotational control but overconstrained IR, leading to a change from intact knee kinematics. LEVEL OF EVIDENCE: The level-of-evidence statement does not apply for this laboratory experiments study.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Tenodese/métodos , Fenômenos Biomecânicos , Cadáver , Fascia Lata/cirurgia , Humanos , Articulação do Joelho/fisiopatologia , Ligamentos Articulares/fisiopatologia , Ligamentos Articulares/cirurgia , Amplitude de Movimento Articular , Procedimentos de Cirurgia Plástica/métodos , Rotação , Tíbia/fisiopatologia , Tíbia/cirurgia
11.
Am J Sports Med ; 49(5): 1270-1278, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33630656

RESUMO

BACKGROUND: There is currently no analysis of 1-year postoperative magnetic resonance imaging (MRI) that reproducibly evaluates the graft of a hamstring autograft anterior cruciate ligament reconstruction (ACLR) and helps to identify who is at a higher risk of graft rupture upon return to pivoting sports. PURPOSE: To ascertain whether a novel MRI analysis of ACLR at 1 year postoperatively can be used to predict graft rupture, sporting level, and clinical outcome at a 1-year and minimum 2-year follow-up. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Graft healing and integration after hamstring autograft ACLR were evaluated using the MRI signal intensity ratio at multiple areas using oblique reconstructions both parallel and perpendicular to the graft and tunnel apertures. Clinical outcomes were assessment of side-to-side laxity and International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Lysholm, and Tegner activity level scores at 1 year. Repeat outcome measures and detection of graft rupture were evaluated at a minimum of 2 years. RESULTS: A total of 250 patients (42.4% female) underwent MRI analysis at 1 year, and assessment of 211 patients between 1 year and the final follow-up (range, 24-36 months) detected 9 graft ruptures (4.3%; 5 in female patients). A significant predictor for graft rupture was a high signal parallel to the proximal intra-articular graft and perpendicular to the femoral tunnel aperture (P = .032 and P = .049, respectively), with each proximal graft signal intensity ratio (SIR) increase by 1 corresponding to a 40% increased risk of graft rupture. A cutoff SIR of 4 had a sensitivity and specificity of 66% and 77%, respectively, in the proximal graft and 88% and 60% in the femoral aperture. In all patients, graft signal adjacent to and within the tibial tunnel aperture, and in the mid intra-articular portion, was significantly lower than that for the femoral aperture (P < .001). A significant correlation was seen between the appearance of higher graft signal on MRI and those patients achieving top sporting levels by 1 year. CONCLUSION: ACLR graft rupture after 1 year is associated with MRI appearances of high graft signal adjacent to and within the femoral tunnel aperture. Patients with aspirations of quickly returning to a high sporting level may benefit from MRI analysis of graft signal. Graft signal was highest at the femoral tunnel aperture, adding further radiographic evidence that the rate-limiting step to graft healing occurs proximally.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Tendões dos Músculos Isquiotibiais , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Autoenxertos/cirurgia , Estudos de Casos e Controles , Feminino , Tendões dos Músculos Isquiotibiais/diagnóstico por imagem , Humanos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Masculino , Transplante Autólogo , Resultado do Tratamento
12.
Surg Obes Relat Dis ; 17(3): 555-561, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33272856

RESUMO

BACKGROUND: Magnetic sphincter augmentation (MSA) has gained popularity as a treatment for gastroesophageal reflux disease (GERD). The role of MSA in treating GERD in metabolic and bariatric surgery (MBS) patients at the time of primary MBS is unknown. OBJECTIVE: To determine the short-term outcomes of MSA placed at the time of MBS. SETTING: National database, United States. METHODS: We queried the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP) database for MSA performed at time of the sleeve gastrectomy (SG) and Roux-en-Y gastric bypass (RYGB) for the years 2017-2018. A propensity adjusted analysis was performed to assess 30-day outcomes of patients who had MSA placed versus those who did not. RESULTS: There were 319,580 patients who underwent MBS in the study period. Twenty-four patients had MSA at time of surgery. These patients did not have a higher reported rate of preoperative GERD (P = .93). Six patients (25%) with MSA had a RYGB; the other 18 patients (75%) patients had SG (P < .001). Operative times were similar between the groups and there was no difference in length of stay. After propensity matched analysis (with 24 patients in each arm), patients who underwent an MSA had shorter discharge times (1.4 days [.8] versus 2.0 [.9], P = .012). CONCLUSION: MSA is safe in the short term in MBS. There is no difference in major morbidity or mortality and operative times are similar in MSA patients. The long-term efficacy of this practice is unknown.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Acreditação , Gastrectomia , Humanos , Fenômenos Magnéticos , Obesidade Mórbida/cirurgia , Melhoria de Qualidade , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos
13.
Knee ; 28: 1-8, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33278738

RESUMO

BACKGROUND: There has been increased use of adjustable suspensory fixation (ASF) for anterior cruciate ligament reconstruction (ACLR). Potential benefits are the ability to use a shorter graft and to prevent graft displacement and damage. The purpose of this study was to establish the efficacy of this fixation method and assess whether it leads to less tunnel widening, and avoids known complications of screw fixation. METHODS: Thirty-eight patients who underwent ACLR with ASF on both the femoral and tibial sides met the inclusion criteria and were propensity matched demographically with 38 patients who underwent hybrid fixation with femoral suspensory and tibial screw and sheath. At one-year, KT-1000 knee laxity measurements were recorded and detailed MRI analysis looking at tunnel aperture widening, tunnel appearance, graft integration within the tunnels, and graft healing. RESULTS: MRI comparison between ASF and hybrid cohorts revealed no significant differences in graft signal or integration, and clinically there were no differences in knee laxity between cohorts (mean 1.5 mm ± 2.0 and 1.5 mm ± 2.3 (n.s.) in the ASF and hybrid fixation respectively). Significantly less aperture tibial tunnel widening (2.2 mm versus 4.4 mm, p < 0.0001) and tibial cysts (2 versus 9, p = 0.047) were observed in the ASF cohort, whilst mean femoral tunnel widening was comparable between both cohorts (ASF 2.8 mm, hybrid 3.2 mm; n.s.). CONCLUSIONS: Hamstring autografts for ACLR fixed using either ASF or a hybrid fixation technique provided comparable knee stability and MRI graft signal intensity. Tibial ASF demonstrated significantly less tibial aperture widening and tunnel cyst formation when compared to screw and sheath fixation.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tendões dos Músculos Isquiotibiais/transplante , Adulto , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Autoenxertos/transplante , Parafusos Ósseos , Estudos de Coortes , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tíbia/cirurgia , Transplante Autólogo
14.
Knee Surg Sports Traumatol Arthrosc ; 29(9): 3010-3016, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33118063

RESUMO

PURPOSE: For a successful return to sport (RTS) after an anterior cruciate ligament reconstruction (ACLR), patients are recommended to attend a comprehensive rehabilitation program, followed by an RTS assessment, that is a combination of tests. The purpose of this study was to predict a successful return to sport using the results of the RTS assessment and self-reported questionnaires at minimum 2 years after ACLR. METHODS: A total of 123 consecutive ACLR patients undertook an intensive rehabilitation program followed by a comprehensive RTS assessment that included an established combination of balance and strength tests, the ACL-return to sport after Injury scale (ACL-RSI) questionnaire and a KT1000 laximetry test. Preinjury and expected Tegner and Lysholm were collected at baseline, at RTS and prospectively collected at minimum 2-year follow-up. The patients were asked if they returned to their previous sport and at which level. All variables were included in a regression analysis predicting a successful return to previous sport, return to the same level of sport as well as the Tegner level at 2 years. RESULTS: Sixty-two patients (50%) returned to their previous sport by the 2-year follow-up, without a difference in preinjury Tegner between these two groups (n.s.). Expected preoperative Tegner was the only significant predictor of a successful return to previous sport (p = 0.042; OR 1.300, 95% CI 1.010-1.672). Out of the 62 patients returning to their previous sport, 38 (61%) reported to be on the same or higher level. The only predictive variable for returning to the same level was the higher preinjury Tegner level (p = 0.048; OR 1.522). Multivariate regression analysis of Tegner level at 2 years found younger age to be the only predictive value. From the RTS assessment tests, the ACL-RSI questionnaire and the posterolateral balance test were predictive variables for Tegner at 2-year follow-up, albeit in the univariate regression analysis. CONCLUSIONS: Preoperative Tegner and expected Tegner level collected prior to an ACL reconstruction can aid in the objective prediction of patients' return to sport after 2 years. High-level athletes are more likely to return to their previous sport and to the previous level. Younger patients achieve a higher Tegner level at 2 years. LEVEL OF EVIDENCE: Level III study.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Esportes , Lesões do Ligamento Cruzado Anterior/cirurgia , Atletas , Humanos , Volta ao Esporte
15.
Knee Surg Sports Traumatol Arthrosc ; 28(7): 2105-2115, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32157364

RESUMO

PURPOSE: The aim of this study was to determine if a difference exists in the relationship between the femoral intercondylar notch volume, and the volumes of anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) in ACL injured patients and healthy subjects. METHODS: Intact knees of 19 healthy subjects and bilateral knees of 18 ipsilateral ACL reconstructed patients were scanned using 3-tesla high-resolution magnetic resonance imaging. The intercondylar notch, ACL, PCL and hamstring graft were segmented using three-dimensional (3D) processing software. The native intercondylar notch, ACL, and PCL volumes were compared between both groups. The volumes of native ACL and graft were compared in ACL injured patients. RESULTS: The following volumes showed no significant differences between the ACL injured group and control group; intercondylar notch (9.9 ± 2.3 vs 9.6 ± 1.7 cm3), ACL (2.4 ± 0.7 vs 2.4 ± 0.6 cm3) and PCL (3.9 ± 1.0 vs 3.4 ± 0.8 cm3), and the ratio of the ACL to the intercondylar notch (24.6 ± 5.0 vs 25.4 ± 2.9%). There was a significant difference in the ratio of PCL to the intercondylar notch (39.1 ± 4.3 vs 35.9 ± 4.9%, p = 0.023). The graft was significantly larger than native ACL volume (3.0 ± 0.7 vs 2.4 ± 0.7 cm3, p = 0.012). CONCLUSIONS: The ratio of the PCL volume in the femoral intercondylar notch was higher in the ACL injured group compared to the healthy control group, despite the ratio of ACL volume in the femoral intercondylar notch being similar in both groups. A greater awareness of the potentially limited space for the graft alongside the PCL within the femoral intercondylar notch may allow surgeons a more informed choice of graft type and size. LEVEL OF EVIDENCE: IV.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/fisiologia , Adolescente , Adulto , Reconstrução do Ligamento Cruzado Anterior , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Adulto Jovem
16.
Arch Orthop Trauma Surg ; 140(6): 801-806, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32146591

RESUMO

INTRODUCTION: The most commonly used tool for implant positioning are conventional instruments (CI) followed by computer-assisted surgery (CAS). A number of studies have investigated the cutting error of the tibial component when CAS is used, but most of them were focused on the cutting angles. The accuracy of CAS to determine the depth of the cut has not received much attention, even though implications are similar or worse, than with an angle mismatch. MATERIALS AND METHODS: This was an ethics board approved, prospective study of 23 consecutive varus TKAs by a single surgeon. Implant positioning was performed using CAS; however, the depth of the tibial cut was determined with both CAS and CI. Targeted alignment was the mechanical axis and 3° of posterior slope. The planned and the achieved cut, as determined by CAS needed to match. The achieved cut was then measured using a caliper and compared to the depth of the cut as per CAS. Medial and lateral cuts were analyzed separately. Analysis of variance and Bland-Altman plots were used for the comparison. RESULTS: Mean medial navigated cut was 6.3 (± 2.2) mm, mean measured medial cut was 6.6 (± 2.3) mm. Mean lateral navigated cut was 8.9 (± 1.8) mm, mean measured lateral cut was 8.8 (± 1.5) mm. There was a statistical significance for both the medial (p < 0.001) and the lateral (p = 0.004) navigated and measured cuts. CONCLUSIONS: The results of this study suggest that the tibial cut depth, measured by the navigation, does not match the actual bony cuts performed, even if a perfect cut was achieved in both sagittal and coronal plane. Surgeons should be aware of the measurement error in the navigation system and potentially add an additional step for verifying the achieved depth of the cut.


Assuntos
Artroplastia do Joelho , Cirurgia Assistida por Computador , Tíbia/cirurgia , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/normas , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Estudos Prospectivos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/normas , Cirurgia Assistida por Computador/estatística & dados numéricos
17.
Knee Surg Sports Traumatol Arthrosc ; 28(3): 906-914, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31209542

RESUMO

PURPOSE: To present the clinical outcomes and magnetic resonance imaging (MRI) analysis of adjustable cortical suspensory fixation for the femur and tibia in hamstring autograft anterior cruciate ligament reconstruction. METHODS: A cohort of 233 sequential patients was analysed for graft failure rate and subjective IKDC, Tegner and Lysholm scores. 144 validated 1-year MRIs assessed and correlated graft healing and tunnel widening. RESULTS: At mean follow-up of 28 months ± 8.2 [median 26, range 12-49], the graft failure rate was 4.7%. Significant improvements were seen in all clinical scores (p < 0.001). MRI analysis showed 71% with fully integrated grafts in the tibia and 24% in the femur, with the remainder all showing greater than 50% integration. Graft signal was low and homogenous in 67% in the tibia, 29% in the intra-articular portion and 20% in the femur. One patient had greater than 50% high signal in the tibial graft and one in the intra-articular graft, all others demonstrated greater than 50% low signal. Both graft integration and signal were significantly better in the tibia than the femur (p < 0.01). Tunnel widening was 2.2 ± 1.4 mm and 2.7 ± 1.3 mm in the tibia and femur, respectively. Comparison of individual MRI appearances and overall clinical outcome at the same 12-month point demonstrated no consistent significant correlation. CONCLUSION: Adjustable cortical suspensory fixation in both femoral and tibial tunnels provides good clinical outcomes and a low graft rupture rate. Grafts demonstrate healing with comparatively low tunnel widening. There was no consistent significant correlation between the appearances on MRI and clinical outcome. LEVEL OF EVIDENCE: Case-control study, Level III.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Tendões/transplante , Tíbia/cirurgia , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Estudos de Casos e Controles , Estudos de Coortes , Músculos Isquiossurais/cirurgia , Humanos , Imageamento por Ressonância Magnética , Transplante Autólogo , Cicatrização , Adulto Jovem
18.
Am J Sports Med ; 48(1): 99-108, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31730373

RESUMO

BACKGROUND: The combined influence of anatomic and operative factors affecting graft healing after anterior cruciate ligament (ACL) reconstruction within the femoral notch is not well understood. PURPOSE: To determine the influence of graft size and orientation in relation to femoral notch anatomy, with the signal/noise quotient (SNQ) of the graft used as a measure of graft healing after primary single-bundle ACL reconstruction. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 98 patients with a minimum 2-year follow-up after primary single-bundle ACL reconstruction with hamstring tendon autografts were included. Graft healing was evaluated at 1 year on magnetic resonance imaging (MRI) scan as the mean SNQ measured from 3 regions situated at sites at the proximal, middle, and distal graft. Patient characteristics, chondropenia severity score, tunnel sizes, tunnel locations, graft bending angle (GBA), graft sagittal angle, posterior tibial slope (PTS), graft length, graft volume, femoral notch volume, and graft-notch volume ratio (measured using postoperative 3-T high-resolution MRI) were evaluated to determine any association with 1-year graft healing. The correlation between 1-year graft healing and clinical outcome at minimum 2 years was also assessed. RESULTS: There was no significant difference in mean SNQ between male and female patients (P > .05). Univariate regression analysis showed that a low femoral tunnel (P = .005), lateral tibial tunnel (P = .009), large femoral tunnel (P = .011), large tibial tunnel (P < .001), steep lateral PTS (P = .010), steep medial PTS (P = .004), acute graft sagittal angle (P < .001), acute GBA (P < .001), large graft volume (P = .003), and high graft-notch volume ratio (P < .001) were all associated with higher graft SNQ values. A multivariate regression analysis showed 2 significant factors: a large graft-notch volume ratio (P = .001) and an acute GBA (P = .004). The 1-year SNQ had a weak correlation with 2-year Tegner Activity Scale score (r = 0.227; P = .026) but no other clinical findings, such as International Knee Documentation Committee subjective and Lysholm scores and anterior tibial translation side-to-side difference. CONCLUSION: The 1-year SNQ value had a significant positive association with graft-notch volume ratio and GBA. Both graft size and graft orientation appeared to have a significant influence on graft healing as assessed on 1-year high-resolution MRI scan.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Adulto , Autoenxertos/cirurgia , Feminino , Tendões dos Músculos Isquiotibiais/transplante , Humanos , Escore de Lysholm para Joelho , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Tíbia/cirurgia , Transplante Autólogo , Adulto Jovem
19.
Mil Med ; 184(9-10): e412-e416, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31216358

RESUMO

INTRODUCTION: Since inception of robotic-assisted surgery (RAS) in 1999, there has been an exponential rise in RAS in both number and complexity of surgical cases performed. The majority of these cases are gynecologic surgery in nature, with only a quarter of them labeled as general surgery. The purpose of this study is to determine if RAS in the Department of Defense (DoD) mirrors these trends. METHODS: A total of 6,204 RAS cases from across the DoD were reviewed between 01 January 2015 and 30 September 2017 from every Military Treatment Facility (MTF) that employs a robotic surgical device (various models of the da Vinci robotic surgical system by Intuitive Surgical). Specialty, number, and surgeon were recorded for each case. These end points were also examined for trends overtime and compared to similar civilian data. RESULTS: The number of MTFs performing robotic surgery and the number of cases performed increased significantly. An average of 373 cases per quarter-year were performed in 2015, 647 in 2016, and 708 in 2017. The number of RAS cases increased by about 10% every quarter-year during this time period. RAS was most commonly performed by general surgery in 10 of the 14 MTFs examined. CONCLUSIONS: MTFs implemented RAS much later than the civilian world. However, since its implementation, the frequency of RAS use has increased at a faster rate in the DoD than in the civilian world. Possible reasons for this are a younger pool of surgeons in the military and less demands on cost-effective productivity, allowing these younger surgeons to focus on emerging technology rather than maximizing surgical cost efficiency. General surgery constitutes the majority of RAS cases in the DoD. It is unclear why this difference from the civilian world exists.


Assuntos
Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/tendências , Humanos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Resultado do Tratamento , Estados Unidos , United States Department of Defense/organização & administração , United States Department of Defense/estatística & dados numéricos
20.
Knee ; 26(3): 537-544, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31103414

RESUMO

BACKGROUND: The tibial bony attachments of the anterior cruciate ligament (ACL) and the anterolateral meniscal root (ALMR) are very close, and drilling the tibial tunnel in ACL reconstruction may damage the ALMR attachment. This study investigated the relationship between the tibial attachment of the ACL and ALMR using high-resolution 3-T magnetic resonance imaging (MRI). METHODS: Twenty healthy subjects (35.8 ±â€¯13.0 years) had 20 knees scanned using high resolution 3-T MRI. The tibial bony attachments of ACL, ALMR, and the tibia were segmented and three-dimensional models were created. The shape, area, and location of each attachment were evaluated using this model. RESULTS: The ACL tibial attachment was elliptical in nine knees (45%), C-shaped in nine knees (45%) and triangle in two knees (10%). The mean values of the ACL vs ALMR tibial attachments were as follows: area, 106.2 ±â€¯21.3 vs 56.2 ±â€¯21.3 mm2; length, 16.8 ±â€¯2.0 vs 11.0 ±â€¯1.8 mm; and width, 6.9 ±â€¯1.3 vs 6.6 ±â€¯1.0 mm. The location of the ACL vs ALMR attachment centres was 46.5 ±â€¯1.7% vs 56.5 ±â€¯1.9% in the medial-lateral direction and 36.3 ±â€¯3.6% vs 36.7 ±â€¯3.5% in the anterior-posterior direction. The distance between the ACL and ALMR centres was 8.1 ±â€¯1.3 mm. CONCLUSIONS: ACL and ALMR tibial attachments were individually distinguished using high resolution 3-T MRI. The short distance between both centres of the attachments may suggest that ALMR can be damaged when the tibial tunnel is drilled in ACL reconstruction.


Assuntos
Ligamento Cruzado Anterior/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Meniscos Tibiais/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Adulto , Ligamento Cruzado Anterior/anatomia & histologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Meniscos Tibiais/anatomia & histologia , Tíbia/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA