Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Scand J Trauma Resusc Emerg Med ; 29(1): 98, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34281616

RESUMO

BACKGROUND: Self-Inflating Resuscitation Bags (SIRB) are common and essential tools in airway management and ventilation. They are often used in resuscitation and emergency anaesthesia outside the operating theatre. There is a common notion that all SIRBs applied with a tight sealed mask will deliver close to 100 % oxygen during spontaneous breathing. The aim of the study was to measure the oxygen delivery of six commonly used SIRBs in a mechanical spontaneous breathing adult in vitro model. METHODS: Three SIRBs of each of the six models were evaluated for oxygen delivery during simulated breathing with an adult mechanical lung. The test was repeated three times per device (54 tests in total). The breathing profile was fixed to a minute volume of 10 L/min, a tidal volume of 500 mL and the SIRBs supplied with an oxygen fresh gas flow of 15 L/min. The fraction of delivered oxygen (FDO2) was measured over a three-minute period. Average FDO2 was calculated and compared at 30, 60 and 90 s. RESULTS: At 90 s all models had reached a stable FDO2. Average FDO2 at 90 s; Ambu Oval Plus 99,5 %; Ambu Spur II 99,8 %; Intersurgical BVM Resuscitator 76,7 %; Laerdal Silicone 97,3 %; Laerdal The Bag II 94,5 % and the O-Two Smart Bag 39,0 %. All differences in FDO2 were significant apart from the two Ambu models. CONCLUSIONS: In simulated spontaneous breathing, four out of six (by Ambu and Laerdal) Self-Inflating Resuscitation Bags delivered a high fraction of oxygen while two (Intersurgical and O-two) underperformed in oxygen delivery. These large variations confirm results reported in other studies. It is our opinion that underperforming Self-Inflating Resuscitation Bags might pose a serious threat to patients' health if used in resuscitation and anaesthesia. Manufacturers of Self-Inflating Resuscitation Bags rarely provide information on performance for spontaneous breathing. This poses a challenge to all organizations that need their devices to deliver adequate oxygen during spontaneous breathing.


Assuntos
Simulação por Computador , Oxigênio/administração & dosagem , Ressuscitação/instrumentação , Desenho de Equipamento , Humanos , Oxigênio/análise , Volume de Ventilação Pulmonar
2.
Anesthesiol Res Pract ; 2016: 6308371, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27974889

RESUMO

Introduction. For surgery on the upper extremity, the anaesthetist often has a choice between regional anaesthesia (RA) and general anaesthesia (GA). We sought to investigate the possible differences between RA and GA after upper extremity surgery with regard to postoperative patient comfort. Methods. This is a retrospective observational study that was performed at an acute care secondary referral centre. One hundred and eighty-seven procedures involving orthopaedic surgery on the upper extremity were included. The different groups (RA and GA) were compared regarding the primary outcome variable, length of stay in Postanaesthesia Unit, and secondary outcome variables, opioid consumption and nausea treatment. Results. RA was associated with significantly shorter median length of stay (99 versus 171 minutes). In the GA group, 32% of the patients received opioid analgesics and 21% received antiemetics. In the RA group, none received opioid analgesics and 3% received antiemetics. Conclusion. In this observational study, RA was superior to GA for surgery of the upper extremity regarding Postanaesthesia Care Unit length of stay, number of doses of analgesic, and number of doses of antiemetic administered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA