1.
Artif Organs ; 36(10): 875-85, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22803968

RESUMO

New generation oxygenators with integrated arterial line filters have been marketed to improve the efficacy of cardiopulmonary bypass (CPB). Differences in designs, materials, coating surfaces, pore size of arterial filter, and static prime exist between the oxygenators. Despite abundant preclinical data, literature lacks clinical studies. From September 2010 to March 2011, 80 consecutive patients were randomized to CPB using Terumo Capiox FX25 (40 patients, Group-T) or Sorin Synthesis (40 patients, Group-S) oxygenators. Pressure drop and gas exchange efficacy were registered during CPB. High-sensitivity C-reactive protein (hs-CRP), white blood cells (WBCs), fluid balance, activated clotting time, international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, platelets (PLTs), serum albumin, and total proteins were measured perioperatively at different timepoints. Clinical outcome was recorded. Repeated measure analysis of variance and nonparametric statistics assessed between-groups and during time differences. The two groups showed similar baseline and intraoperative variables. No differences were recorded in pressure drop and gas exchange (group-P and group*time-P = N.S. for all) during CPB. Despite similar fluid balance (P = N.S. for static/dynamic priming and ΔVolume administered intraoperatively), Group-T showed higher hs-CRP (group-P = 0.034), aPTT (group-P = 0.0001), and INR (group-P= 0.05), with lower serum albumin (group-P = 0.014), total proteins (group-P = 0.0001), fibrinogen (group-P = 0.041), and PLTs (group-P = 0.021). Group-T also showed higher postoperative bleeding (group-P = 0.009) and need for transfusions (P = 0.008 for packed red cells and P = 0.0001 for fresh frozen plasma and total transfused volumes). However, clinical outcome was comparable (P = N.S. for all clinical endpoints). Both oxygenators proved effective and resulted in comparable clinical outcomes. However, Sorin Synthesis seems to reduce inflammation and better preserve the coagulative cascade and serum proteins, resulting in lower transfusions and post-CPB inflammatory response.


Assuntos
Ponte Cardiopulmonar/instrumentação , Filtração/instrumentação , Oxigenadores , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Proteína C-Reativa/imunologia , Feminino , Humanos , Contagem de Leucócitos , Masculino , Oxigenadores/efeitos adversos , Contagem de Plaquetas , Troca Gasosa Pulmonar
2.
Clin Chem Lab Med ; 46(8): 1183-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18724812

RESUMO

BACKGROUND: To investigate the potential use of Artificial Neural Network (ANN) in the evaluation of serum protein electrophoresis, we set up a multicenter study involving six Italian laboratories. For this purpose, we developed an algorithm named CASPER (Computer Assisted Serum Protein Electrophoresis Recognizer). METHODS: A total of 59,516 samples from the six centers were divided into three groups. Training and validation sets were used to develop the neural network, whereas evaluation set was used to test the performance of CASPER in recognizing abnormal electrophoretic profiles. RESULTS: CASPER showed 93.0% sensitivity and 47.4% specificity. CASPER sensitivity and specificity ranged in the six sites from 88% (site 3) to 97% (site 5) and from 36% (site 6) to 53% (site 3), respectively. Sensitivity for gamma zone was 94.6%, for beta zone 89.7% and for oligoclonal patterns 92.0%. CONCLUSIONS: The sensitivity of the CASPER algorithm does not allow us to recommend its use as a replacement for the visual inspection, but it could be helpful in avoiding accidental misclassifications by the operator. Moreover, the CASPER algorithm may be a useful tool for training operators and students. This study evidenced a high inter-observer variability, which should be addressed in a dedicated study. Data set to train and validate ANNs should contain a huge range and an adequate number of different abnormalities.


Assuntos
Algoritmos , Anticorpos Monoclonais/sangue , Computadores , Eletroforese das Proteínas Sanguíneas , Redes Neurais de Computação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade