Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Nat Commun ; 8: 16051, 2017 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-28714466

RESUMO

In the rapidly growing field of spintronics, simultaneous control of electronic and magnetic properties is essential, and the perspective of building novel phases is directly linked to the control of tuning parameters, for example, thickness and doping. Looking at the relevant effects in interface-driven spintronics, the reduced symmetry at a surface and interface corresponds to a severe modification of the overlap of electron orbitals, that is, to a change of electron hybridization. Here we report a chemically and magnetically sensitive depth-dependent analysis of two paradigmatic systems, namely La1-xSrxMnO3 and (Ga,Mn)As. Supported by cluster calculations, we find a crossover between surface and bulk in the electron hybridization/correlation and we identify a spectroscopic fingerprint of bulk metallic character and ferromagnetism versus depth. The critical thickness and the gradient of hybridization are measured, setting an intrinsic limit of 3 and 10 unit cells from the surface, respectively, for (Ga,Mn)As and La1-xSrxMnO3, for fully restoring bulk properties.

2.
AIP Adv ; 6(8): 085109, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27648371

RESUMO

We introduce an innovative approach to the simultaneous control of growth mode and magnetotransport properties of manganite thin films, based on an easy-to-implement film/substrate interface engineering. The deposition of a manganite seed layer and the optimization of the substrate temperature allows a persistent bi-dimensional epitaxy and robust ferromagnetic properties at the same time. Structural measurements confirm that in such interface-engineered films, the optimal properties are related to improved epitaxy. A new growth scenario is envisaged, compatible with a shift from heteroepitaxy towards pseudo-homoepitaxy. Relevant growth parameters such as formation energy, roughening temperature, strain profile and chemical states are derived.

3.
Rev Sci Instrum ; 85(7): 075116, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25085182

RESUMO

We present a novel method of delivering a low-concentration (<15%) ozone beam to an ultra-high vacuum environment for the purpose of cleaning and dosing experimental samples through oxidation processing. The system described is safe, low-cost, and practical and overcomes the limitations of ozone transport in the molecular flow environment of high or ultrahigh vacuum whilst circumventing the use of pure ozone gas which is potentially highly explosive. The effectiveness of this method in removing surface contamination is demonstrated through comparison of high-temperature annealing of a simple oxide (MgO) in ozone and oxygen environments as monitored using quadrupole mass spectroscopy and Auger electron spectroscopy. Additionally, we demonstrate the potential of ozone for obtaining clean complex oxide surfaces without the need for high-temperature annealing which may significantly alter surface structure.

4.
Sci Rep ; 4: 5353, 2014 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-24941969

RESUMO

Ultrathin manganite films are widely used as active electrodes in organic spintronic devices. In this study, a scanning tunnelling microscopy (STM) investigation with atomic resolution revealed previously unknown surface features consisting of small non-stoichiometric islands. Based upon this evidence, a new mechanism for the growth of these complex materials is proposed. It is suggested that the non-stoichiometric islands result from nucleation centres that are below the critical threshold size required for stoichiometric crystalline growth. These islands represent a kinetic intermediate of single-layer growth regardless of the film thickness, and should be considered and possibly controlled in manganite thin-film applications.

5.
Chem Commun (Camb) ; 49(98): 11506-8, 2013 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-24177225

RESUMO

Structural features and magnetic behaviour of TbPc2 thin films sublimated on LSMO and on cobalt surfaces have been investigated by synchrotron-based XNLD and XMCD techniques. Different orientation of the molecules is observed for the two substrates. No significant magnetic interaction with the ferromagnetic substrates is detected.

6.
Curr Eye Res ; 17(1): 53-9, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9472471

RESUMO

PURPOSE: To assess intra- and interobserver reproducibility of the Age-Related Eye Disease Study (AREDS) system for grading lens opacities and to provide data on its capacity to reliably detect changes in lens status. METHODS: Independent and replicate grading of 40 sets of lens photographs (one slit-lamp and two retroillumination photographs) were performed by three experienced observers. Patients were participants in the Collaborative Italian-American Clinical Trial of Nutritional Supplements which is testing the effect of a mineral-multivitamin supplement on age-related cataract (CTNS). Scatterplots and intraclass correlation were used to assess measurement error. RESULTS: Analysis revealed good intra- and interobserver reproducibility of the system. Greatest intraobserver measurement error showed 100% of pairs within 10% areal difference for cortical cataract, 97.5% within 15% areal difference for posterior subcapsular cataract, and 100% within 1 density unit difference for nuclear opacity. Greatest interobserver measurement error showed 95% of pairs within 10% areal difference for cortical cataract, 97.5% within 15% areal difference for posterior subcapsular cataract, and 97.5% within 1.5 density unit difference for nuclear opacity. CONCLUSIONS: The AREDS lens opacities grading system appears to be sufficiently reliable to detect changes of at least 10% areal involvement for cortical, 15% areal involvement for posterior subcapsular, and 1.0 units for nuclear opacities. It therefore seems sufficiently sensitive to adequately monitor progression of lens opacities in a longitudinal study of patients with early cataract. Its applicability in a population with advanced or complex mixed opacities must await further testing.


Assuntos
Envelhecimento , Catarata/classificação , Catarata/diagnóstico , Humanos , Cristalino/patologia , Variações Dependentes do Observador , Oftalmologia/métodos , Fotografação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Arq Bras Cardiol ; 67(6): 395-400, 1996 Dec.
Artigo em Português | MEDLINE | ID: mdl-9246827

RESUMO

PURPOSE: To investigate the short-term effects of the partial ventriculectomy (resection of lateral wall associated to mitral annuloplasty) on cardiac mechanics, contractility, shape and geometry of the left ventricle (LV). METHODS: Eleven male patients with severe congestive heart failure due to dilated cardiomyopathy were studied. The mean age was 51 +/- 7 years and the functional class was III (five patients) or IV (six patients) before the surgery. Patients were evaluated before and at 17 +/- 4 days after the surgery by simultaneous LV pressure and echocardiographic data. End-diastolic pressure (EDP-mmHg), wall stress (EDS-g/cm2) and diameter (EDD-cm); endsystolic wall stress (ESS) and diameter (ESD), fractional shortening (FS-%) and maximal elastance (Emax-mmHg/ cm/s); the diastolic slope of the pressure-diameter (Kp-mmHg/cm) and stress-strain (Km-g/cm2) loops; shape (L/ EDD, adimensional, where L is the LV long axis) and geometry (Th/EDD, adimensional, where TH is the LV diastolic thickness) were obtained. RESULTS: 1) The ressected muscle fragments (diamond shape) were 10.8 +/- 1.3 cm in length and 5 +/- 0.6 cm in width; 2) all patients were discharged from hospital (15-29 days) in class I (eight cases), II (two), and III (one); 3) it was observed a decrease in EDP (24.3 +/- 7.7 x 17.5 +/- 3.2, p = 0.016); in EDD (8.0 +/- 0.7 x 7.2 +/- 0.8, p = 0.002); in EDS (57.9 +/- 26.8 x 37.4 +/- 19.2, p = 0.005); in ESS (199 +/- 46.9 x 102.8 +/- 33.1, p = 0.004); in ESD (7.1 +/- 0.7 x 5.7 +/- 0.8, p < 0.001); in Kp (22.3 +/- 15.9 x 11.5 +/- 6.9, p = 0.014); and in K(m) (467.4 +/- 212 x 214.6 +/- 87.4, p = 0.01); and, 4) it was noted an increase in FS (11.5 +/- 1.8 x 19.8 +/- 3.9, p < 0.001); in Emax (13.8 +/- 2.2 x 18.6 +/- 3.2, p < 0.001); and in L/EDD (1.32 +/- 0.1 x 1.47 +/- 0.13, p < 0.007) and Th/Dd (0.11 +/- 0.04 x 0.17 +/- 0.08, p < 0.038). CONCLUSION: The partial ventriculectomy showed multiple significant beneficial effects in these dilated myopathic hearts.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Ventrículos do Coração/cirurgia , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Elasticidade , Eletrocardiografia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Período Pós-Operatório , Função Ventricular
8.
Arq Bras Cardiol ; 67(2): 87-91, 1996 Aug.
Artigo em Português | MEDLINE | ID: mdl-9110439

RESUMO

PURPOSE: The effects of ibopamine (IBO) on left ventricular (LV) mechanics and contractility have not been described. The aim of this study was to test the hypothesis that IBO has a contractile effect at a dose of 200 mg. METHODS: Ten male patients (43 +/- 7 years) with refractory heart failure due to idiopathic dilated cardiomyopathy were studied. The patients were submitted to simultaneous echo-Doppler and hemodynamic (microtip catheter) studies, before (B) and after (20, 40 and 60 minutes) a dose of 200 mg of IBO. LV pressure/diameter and stress/strain relations were obtained. Subsequently, heart rate (HR-bpm), cardiac output (CO-L/m), end-diastolic pressure (EDP-mmHg); fractional shortening (FS-%); maximal elastance (Emax-mmHg/cm/s); end systolic (ESS-g/cm2) and end-diastolic (EDS-g/cm2) stress; chamber (Kp-mmHg/cm) and muscle (K(m)-g/cm2) stiffness, and the time of constant relaxation (Tau-ms) were analyzed. RESULTS: Results were presented as mean +/- standard deviation for conditions before and after IBO (20, 40 and 60 minutes) respectively. There was no change in HR (99 +/- 7; 100 +/- 7; 99 +/- 8; 99 +/- 10). Significant increases were observed in CO (4.13 +/- 1.28; 4.95 +/- 1.38; 5.13 +/- 1.86; 5.18 +/- 1.57), FS (13.7 +/- 2.4; 15.4 +/- 2.8; 15.9 +/- 1.8; 16.1 +/- 2.0), and Emax (14.8 +/- 3.2; 16 +/- 3.6; 17.7 +/- 4.2; 17.6 +/- 4.2). A transient (20 minutes) increase followed by a decrease (40 and 60 minutes) occurred in EDP (26.3 +/- 4.2; 30.6 +/- 6.4; 24.6 +/- 5.6; 22.3 +/- 4.6), EDS (79.7 +/- 22.8; 91.7 +/- 29.6; 79 +/- 31; 63 +/- 17.3), and Kp (27.2 +/- 12.6; 60 +/- 26.7; 27.9 +/- 11.7; 28.1 +/- 11). CONCLUSION: IBO has a beneficial effect on LV systolic and diastolic function as well as on contractility in patients with heart failure due to idiopathic dilated cardiomyopathy.


Assuntos
Cardiomiopatia Dilatada/fisiopatologia , Cardiotônicos/farmacologia , Desoxiepinefrina/análogos & derivados , Contração Miocárdica/efeitos dos fármacos , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Desoxiepinefrina/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
9.
Invest Ophthalmol Vis Sci ; 37(8): 1698-703, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8675414

RESUMO

PURPOSE: To examine the distribution of cortical opacities across the lens in the Italian-American Natural History Study of Age-Related Cataract and to study the association between an index of sunlight exposure and the location of cortical cataract within the lens. METHODS: Lens photographs of one eye of 731 persons with cortical opacities (503 with pure and 228 with mixed types of opacity) were included in the analysis. A radial grid superimposed on the photographs was used to assess presence, location, and severity of wedge-shaped cortical opacities. RESULTS: Both the prevalence and the extent of cortical opacities were highest in the inferior-nasal quadrant and lowest in the superior-nasal quadrant of the lens. In polychotomous logistic regression, persons with the greatest excess areal involvement in the inferior half of the lens were more likely to have high exposure to sunlight, as measured by a sunlight index, than persons with excess involvement in the superior half of the lens (odds ratio, 1.73; 95% confidence interval 1.03, 2.93). Excess areal involvement of the inferior lens also was associated with the pure type of cortical cataract and with the total extent of the opacity. CONCLUSIONS: Age-related cortical opacities occur more frequently inferiorly than superiorly and, to a lesser extent, nasally than temporally. Possibly higher exposure of these lens segments to sunlight may explain this preferential location of cortical opacities.


Assuntos
Envelhecimento , Catarata/classificação , Catarata/patologia , Córtex do Cristalino/patologia , Idoso , Estudos de Casos e Controles , Catarata/etiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Fotografação , Prevalência , Fatores de Risco , Luz Solar/efeitos adversos
10.
Arq Bras Cardiol ; 63(6): 465-8, 1994 Dec.
Artigo em Português | MEDLINE | ID: mdl-7605229

RESUMO

PURPOSE--To evaluate if the levels of lipoprotein (a) [Lp(a)], apolipoproteins (apo) A1, B and the lipid profile (LP) differ among heart transplantation (HT) patients, with coronary artery disease (CAD) and patients without CAD (NL) and if LP discriminates patients with graft vascular disease (GVD). METHODS--A hundred and seventy patients separated in 3 groups: I) HT [n = 43 46 +/- 15 years, 24 months (median) after transplantation], of these 28 were submitted to serial angiography after the first year of transplantation subgroups with GVD (n = 9) and without GVD (NGVD) (n = 19); II) CAD (n = 72, 48 +/- 6 years); III) NL (n = 45, 50 +/- 6 years). RESULTS--HT presented higher apo A1 levels than CAD and NL (1.5 +/- 0.5 vs 1.2 +/- 0.05 vs 1.1 +/- 0.06 g/l p < 0.05 respectively). Apo B was higher on CAD than in HT and NL (1.5 +/- 0.05 vs 1.2 +/- 0.07 vs 1.3 +/- 0.09 g/l p < 0.05). Lp (a) presented a trend to higher levels in HT and CAD than in NL [25(2-97), 24(1-130) and 15 (1-100) mg/dl, p = 0.05)]. However, when individually evaluated against NL Lp(a) levels were higher in HT and CAD (p = 0.019 and 0.03 respectively). LP did not differ between GVD and NGVD. CONCLUSION--Increased Lp(a) levels after transplantation might be related to the high prevalence of GVD. The LP did not discriminate GVD.


Assuntos
Apolipoproteína A-I/sangue , Apolipoproteínas B/sangue , Doença das Coronárias/etiologia , Transplante de Coração/efeitos adversos , Lipídeos/sangue , Lipoproteína(a)/sangue , Adulto , Idoso , Análise de Variância , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco
11.
Invest Ophthalmol Vis Sci ; 35(1): 262-7, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8300354

RESUMO

PURPOSE: To compare the relationship between logMAR visual acuity (VA) and cataract severity and between contrast sensitivity (CS) and cataract severity in pure types of age-related lens opacities. METHODS: Analysis included patients followed in the ongoing Italian-American Study of the Natural History of Age-Related Cataract. Lens opacities were classified and graded according to the Lens Opacities Classification System II (LOCS II). Visual acuity was measured with the Early Treatment Diabetic Retinopathy Study Chart. Contrast sensitivity was measured with the Pelli-Robson chart. RESULTS: Data from 1,076 eyes were used for the analysis (366 clear lenses; 550, 124, and 36 eyes with cortical, nuclear and posterior subcapsular cataract, respectively). In age-adjusted analyses, increasing severity of all three cataract types was associated with progressively higher logMAR VA, which translates into poorer acuity, and lower CS scores. For both VA and CS, the effect of increasing severity was greatest for nuclear and least for cortical opacities. After adjusting for age and VA, CS scores were no longer associated with cataract type and severity, with the exception of advanced cortical opacities. CONCLUSIONS: Increased cataract severity, as determined by LOCS II grading, is strongly associated with both VA and CS scores. Contrast sensitivity scores obtained from testing at low spatial frequency do not seem to offer additional information over standard VA testing in early cortical and posterior subcapsular opacities nor in nuclear cataracts.


Assuntos
Envelhecimento/fisiologia , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Catarata/classificação , Feminino , Humanos , Córtex do Cristalino/fisiopatologia , Núcleo do Cristalino/fisiopatologia , Masculino , Pessoa de Meia-Idade
12.
Invest Ophthalmol Vis Sci ; 32(8): 2400-3, 1991 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2071351

RESUMO

Data collected from 3646 eyes in the Italian-American Natural History Study of Age-Related Cataract were used to investigate whether the reliability of the Lens Opacities Classification System II (LOCS II) by the severity of the opacity that is being graded or is influenced by the presence and severity of coexisting opacities. Reliability was assessed by comparing the slit-lamp gradings of two clinical examiners (346 eyes) and the gradings performed at the slit lamp with gradings of photographs (3646 eyes). The severity of cortical and nuclear opacities did not affect the reproducibility of slit-lamp gradings, but clinical grading of posterior subcapsular opacities became more reliable as the severity of the posterior subcapsular opacities increased. More advanced coexisting opacities decreased the agreement in the slit-lamp diagnosis of nuclear, but not cortical or posterior subcapsular, opacities. Comparisons of clinical and photographic gradings showed very good to excellent agreement for nuclear and cortical opacities, regardless of the severity of the specific opacity or the severity of the coexisting opacities. Agreement in diagnosing posterior subcapsular opacities was decreased in eyes with milder posterior subcapsular opacities and in eyes with more severe coexisting nuclear and/or cortical opacities. The effect of the severity of the opacity being graded and the severity of coexisting opacities on the reliability of the LOCS II must be considered in studies that use the system to classify and grade cataracts.


Assuntos
Catarata/classificação , Cristalino/patologia , Idoso , Idoso de 80 Anos ou mais , Catarata/patologia , Humanos , Córtex do Cristalino/patologia , Núcleo do Cristalino/patologia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Fotografação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA