1.
J Contemp Brachytherapy ; 10(4): 285-290, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30237811

RESUMO

PURPOSE: The purpose of this study was to compare the prostate contours drawn by two radiation oncologists and one radiologist on magnetic resonance (MR) and transrectal ultrasound (TRUS) images. TRUS intra- and inter-fraction variability as well as TRUS vs. MR inter-modality and inter-operator variability were studied. MATERIAL AND METHODS: Thirty patients affected by localized prostate cancer and treated with interstitial high-dose-rate (HDR) prostate brachytherapy at the National Cancer Institute in Milan were included in this study. Twenty-five patients received an exclusive two-fraction (14 Gy/fraction) treatment, while the other 5 received a single 14 Gy fraction as a boost after external beam radiotherapy. The prostate was contoured on TRUS images acquired before (virtual US) and after (real US) needle implant by two radiation oncologists, whereas on MR prostate was independently contoured by the same radiation oncologists (MR1, MR2) and by a dedicated radiologist (MR3). Absolute differences of prostate volumes (│ΔV│) and craniocaudal extents (│Δdz│) were evaluated. The Dice's coefficient (DC) was calculated to quantify spatial overlap between MR contours. RESULTS: Significant difference was found between Vvirtual and Vlive (p < 0.001) for the first treatment fractions and between VMR1 and VMR2 (p = 0.043). Significant difference between cranio-caudal extents was found between dzvirtual and dzlive (p < 0.033) for the first treatment fractions, between dzvirtual of the first treatment fractions and dzMR1 (p < 0.001) and between dzMR1 and dzMR3 (p < 0.01). Oedema might be responsible for some of the changes in US volumes. Average DC values resulting from the comparison MR1 vs. MR2, MR1 vs. MR3 and MR2 vs. MR3 were 0.95 ± 0.04 (range, 0.82-0.99), 0.87 ± 0.04 (range, 0.73-0.91) and 0.87 ± 0.04 (range, 0.72-0.91), respectively. CONCLUSIONS: Our results demonstrate the importance of a multiprofessional approach to TRUS-guided HDR prostate brachytherapy. Specific training in MR and US prostate imaging is recommended for centers that are unfamiliar with HDR prostate brachytherapy.

2.
Phys Med ; 44: 58-65, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29254592

RESUMO

PURPOSE: A direct planning approach with multi-channel vaginal cylinders (MVCs) used for HDR brachytherapy of vaginal cancers is particularly challenging. Purpose of this study was to compare the dosimetric performances of different forward and inverse methods used for the optimization of MVC-based vaginal treatments for endometrial cancer, with a particular attention to the definition of strategies useful to limit the high doses to the vaginal mucosa. METHODS: Twelve postoperative vaginal HDR brachytherapy treatments performed with MVCs were considered. Plans were retrospectively optimized with three different methods: Dose Point Optimization followed by Graphical Optimization (DPO + GrO), Inverse Planning Simulated Annealing with two different class solutions as starting conditions (surflPSA and homogIPSA) and Hybrid Inverse Planning Optimization (HIPO). Several dosimetric parameters related to target coverage, hot spot extensions and sparing of organs at risk were analyzed to evaluate the quality of the achieved treatment plans. Dose homogeneity index (DHI), conformal index (COIN) and a further parameter quantifying the proportion of the central catheter loading with respect to the overall loading (i.e., the central catheter loading index: CCLI) were also quantified. RESULTS: The achieved PTV coverage parameters were highly correlated with each other but uncorrelated with the hot spot quantifiers. HomogIPSA and HIPO achieved higher DHIs and CCLIs and lower volumes of high doses than DPO + GrO and surflPSA. CONCLUSIONS: Within the investigated optimization methods, HIPO and homoglPSA showed the highest dose homogeneity to the target. In particular, homogIPSA resulted also the most effective in reducing hot spots to the vaginal mucosa.


Assuntos
Braquiterapia , Mucosa/efeitos da radiação , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Vagina/efeitos da radiação , Neoplasias do Endométrio/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
3.
Radiother Oncol ; 118(1): 148-53, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26796593

RESUMO

BACKGROUND AND PURPOSE: To study if MOSkin detectors coupled to a trans-rectal ultrasound (TRUS) probe may be used for in vivo dosimetry on the rectal wall surface during US-based HDR prostate brachytherapy and to quantify possible discrepancies between planned and delivered doses. MATERIALS AND METHODS: MOSkins are a specific type of MOSFET dosimeter optimized to measure dose in steep dose gradients on interfaces. Two MOSkins were assembled on a TRUS probe used for on-line treatment planning. Measurements of the dose to the rectal wall were performed over 18 treatment sessions and compared to the doses calculated on the pre-treatment plan (DPRE) and reconstructed on post-treatment images (DPOST). RESULTS: Averages of the absolute differences between MOSkin readings and DPRE, MOSkin readings and DPOST and DPRE and DPOST were 6.7 ± 5.1%, 3.6 ± 1.9% and 6.3 ± 4.7%, respectively. Agreement between measurements and DPOST was significantly better than between measurements and DPRE (p=0.002) and DPRE and DPOST (p=0.004). Discrepancy between DPOST and DPRE correlated with the time required for treatment planning. CONCLUSION: MOSkin dosimeters integrated to the TRUS probe proved to be an accurate instrument for measuring the dose delivered to the rectal wall in HDR prostate brachytherapy. The delivered doses may differ significantly from those calculated in the treatment plan.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Reto/efeitos da radiação , Ultrassonografia de Intervenção , Idoso , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiometria/métodos , Dosagem Radioterapêutica , Reto/diagnóstico por imagem