Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
IEEE Trans Biomed Eng ; PP2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640051

RESUMO

OBJECTIVE: Transcranial focused ultrasound (tFUS) is being explored for neuroscience research and clinical applications due to its ability to affect precise brain regions noninvasively. The ability to target specific brain regions and localize the beam during these procedures is important for these applications to avoid damage and minimize off-target effects. Here, we present a method to combine optical tracking with magnetic resonance (MR) acoustic radiation force imaging to achieve targeting and localizing of the tFUS beam. This combined method provides steering coordinates to target brain regions within a clinically practical time frame. METHODS: Using an optically tracked hydrophone and bias correction with MR imaging we transformed the FUS focus coordinates into the MR space for targeting and error correction. We validated this method in vivo in 18 macaque FUS studies. RESULTS: Across these in vivo studies a single localization scan allowed for the average targeting error to be reduced from 4.8 mm to 1.4 mm and for multiple brain regions to be targeted with one transducer position. CONCLUSIONS: By reducing targeting error and providing the means to target multiple brain regions within a single session with high accuracy this method will allow further study of the effects of tFUS neuromodulation with more advanced approaches such as simultaneous dual or multi-site brain stimulation.

2.
Magn Reson Med ; 92(1): 246-256, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38469671

RESUMO

PURPOSE: To reduce the inter-scanner variability of diffusion MRI (dMRI) measures between scanners from different vendors by developing a vendor-neutral dMRI pulse sequence using the open-source vendor-agnostic Pulseq platform. METHODS: We implemented a standard EPI based dMRI sequence in Pulseq. We tested it on two clinical scanners from different vendors (Siemens Prisma and GE Premier), systematically evaluating and comparing the within- and inter-scanner variability across the vendors, using both the vendor-provided and Pulseq dMRI sequences. Assessments covered both a diffusion phantom and three human subjects, using standard error (SE) and Lin's concordance correlation to measure the repeatability and reproducibility of standard DTI metrics including fractional anisotropy (FA) and mean diffusivity (MD). RESULTS: Identical dMRI sequences were executed on both scanners using Pulseq. On the phantom, the Pulseq sequence showed more than a 2.5× reduction in SE (variability) across Siemens and GE scanners. Furthermore, Pulseq sequences exhibited markedly reduced SE in-vivo, maintaining scan-rescan repeatability while delivering lower variability in FA and MD (more than 50% reduction in cortical/subcortical regions) compared to vendor-provided sequences. CONCLUSION: The Pulseq diffusion sequence reduces the cross-scanner variability for both phantom and in-vivo data, which will benefit multi-center neuroimaging studies and improve the reproducibility of neuroimaging studies.


Assuntos
Encéfalo , Imagem de Difusão por Ressonância Magnética , Imagens de Fantasmas , Humanos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Anisotropia , Algoritmos , Masculino , Adulto , Feminino
3.
J Control Release ; 363: 707-720, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37827222

RESUMO

The use of focused ultrasound to open the blood-brain barrier (BBB) has the potential to deliver drugs to specific regions of the brain. The size of the BBB opening and ability to localize the opening determines the spatial extent and is a limiting factor in many applications of BBB opening where targeting a small brain region is desired. Here we evaluate the performance of a system designed for small opening volumes and highlight the unique challenges associated with pushing the spatial precision of this technique. To achieve small volume openings in cortical regions of the macaque brain, we tested a custom 1 MHz array transducer integrated into a magnetic resonance image-guided focused ultrasound system. Using real-time cavitation monitoring, we demonstrated twelve instances of single sonication, small volume BBB opening with average volumes of 59 ± 37 mm3 and 184 ± 2 mm3 in cortical and subcortical targets, respectively. We found high correlation between subject-specific acoustic simulations and observed openings when incorporating grey matter segmentation (R2 = 0.8577), and the threshold for BBB opening based on simulations was 0.53 MPa. Analysis of MRI-based safety assessment and cavitation signals indicate a safe pressure range for 1 MHz BBB opening and suggest that our system can be used to deliver drugs and gene therapy to small brain regions.


Assuntos
Barreira Hematoencefálica , Macaca , Animais , Barreira Hematoencefálica/patologia , Encéfalo/diagnóstico por imagem , Ultrassonografia , Sonicação/métodos , Imageamento por Ressonância Magnética , Microbolhas
4.
Brain Stimul ; 16(5): 1430-1444, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37741439

RESUMO

BACKGROUND: MRI-guided transcranial focused ultrasound (MRgFUS) as a next-generation neuromodulation tool can precisely target and stimulate deep brain regions with high spatial selectivity. Combined with MR-ARFI (acoustic radiation force imaging) and using fMRI BOLD signal as functional readouts, our previous studies have shown that low-intensity FUS can excite or suppress neural activity in the somatosensory cortex. OBJECTIVE: To investigate whether low-intensity FUS can suppress nociceptive heat stimulation-induced responses in thalamic nuclei during hand stimulation, and to determine how this suppression influences the information processing flow within nociception networks. FINDINGS: BOLD fMRI activations evoked by 47.5 °C heat stimulation of hand were detected in 24 cortical regions, which belong to sensory, affective, and cognitive nociceptive networks. Concurrent delivery of low-intensity FUS pulses (650 kHz, 550 kPa) to the predefined heat nociceptive stimulus-responsive thalamic centromedial_parafascicular (CM_para), mediodorsal (MD), ventral_lateral (VL_ and ventral_lateral_posteroventral (VLpv) nuclei suppressed their heat responses. Off-target cortical areas exhibited reduced, enhanced, or no significant fMRI signal changes, depending on the specific areas. Differentiable thalamocortical information flow during the processing of nociceptive heat input was observed, as indicated by the time to reach 10% or 30% of the heat-evoked BOLD signal peak. Suppression of thalamic heat responses significantly altered nociceptive processing flow and direction between the thalamus and cortical areas. Modulation of contralateral versus ipsilateral areas by unilateral thalamic activity differed. Signals detected in high-order cortical areas, such as dorsal frontal (DFC) and ventrolateral prefrontal (vlPFC) cortices, exhibited faster response latencies than sensory areas. CONCLUSIONS: The concurrent delivery of FUS suppressed nociceptive heat response in thalamic nuclei and disrupted the nociceptive network. This study offers new insights into the causal functional connections within the thalamocortical networks and demonstrates the modulatory effects of low-intensity FUS on nociceptive information processing.


Assuntos
Nociceptividade , Núcleos Talâmicos , Núcleos Talâmicos/fisiologia , Tálamo , Encéfalo , Cognição
5.
Magn Reson Med ; 90(6): 2321-2333, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37526176

RESUMO

PURPOSE: CEST MRI has been used to probe changes in cardiac metabolism via assessment of CEST contrast from Cr. However, B1 variation across the myocardium leads to spatially variable Cr CEST contrast in healthy myocardium. METHODS: We developed a spatial-spectral (SPSP) saturation pulsed CEST protocol to compensate for B1 variation. Flip angle maps were used to individually tailor SPSP pulses comprised of a train of one-dimensional spatially selective subpulses selective along the principal B1 gradient dimension. Complete Z-spectra in the hearts of (n = 10) healthy individuals were acquired using conventional Gaussian saturation and SPSP schemes and supported by phantom studies. RESULTS: In simulations, the use of SPSP pulses reduced the average SD of the effective saturation B1 values within the myocardium (n = 10) from 0.12 ± 0.02 µT to 0.05 ± 0.01 µT (p < 0.01) and reduced the average SD of Cr CEST contrast in vivo from 10.0 ± 4.3% to 6.1 ± 3.5% (p < 0.05). Results from the hearts of human subjects showed a significant reduction of CEST contrast distribution at 2 ppm, as well as amplitude, when using SPSP saturation. Corresponding phantom experiments revealed PCr-specific contrast generation at body temperature when SPSP saturation was used but combined PCr and Cr contrast generation when Gaussian saturation was used. CONCLUSION: The use of SPSP saturation pulsed CEST resulted in PCr-specific contrast generation and enabled ratiometric mapping of PCr to total Cr CEST contrast in the human heart at 3T.

6.
Magn Reson Imaging ; 103: 169-178, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37543175

RESUMO

Current FDA-approved transcranial MR-guided focused ultrasound (tcMRgFUS) transducers cause a curved dark band in 3 T brain images that runs through midbrain targets of ablative treatments for essential tremor and other applications, and signal is reduced by at least 25% elsewhere in the brain. This limits the set of scans that can be performed to guide and assess the effects of treatment. An electromagnetic simulation study was performed to elucidate the mechanisms causing the dark band. Based on the results, a pair of passive antennas in a "propeller-beanie" configuration were designed to manipulate the reflected waves to avoid signal cancellation within the brain. The antennas were optimized and validated with in-vivo experiments and hydrophone measurements. The simulation study revealed that the dark band is caused by RF waves reflected from the transducer's ground plane, which cancel with incoming waves from the scanner's body coil. The passive antennas shifted the dark band out of the brain and increased transmit efficiency in the center of brain 2.3 times while improving field homogeneity by 50%. They also increased receive sensitivity and SNR in anatomic and temperature imaging. They caused no detectable distortion in hydrophone-measured focal pressure profiles. The conductive ground planes and coupling media used in tcMRgFUS and other piezoelectric FUS transducers interact with a 3 T scanner's RF fields to reduce transmit efficiency and SNR. For tcMRgFUS scenario, "propeller beanie" passive reflecting antennas alleviated these effects. This could make a broader set of imaging sequences available to guide tcMRgFUS treatment.


Assuntos
Artefatos , Tremor Essencial , Humanos , Encéfalo/diagnóstico por imagem , Ultrassonografia , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
7.
Magn Reson Imaging ; 101: 67-75, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37011772

RESUMO

PURPOSE: To understand if unexplained signal artifacts in MRg-LITT proton resonance frequency- (PRF-) shift thermometry images are caused by air bubbles or hemorrhages, and to characterize their effects on temperature measurements. METHODS: Retrospective image data from an IRB-approved clinical trial of intracranial MRg-LITT were inspected for asymmetric distortions observed in phase data during ablations, which have been previously reported as likely hemorrhages. A total of eight patient cases were selected: seven with artifact occurrence and one without. Mathematical image models for air bubbles or hemorrhages were implemented to estimate the size of the air bubble or hemorrhage needed to explain the clinically observed phase artifacts. Correlations and Bland-Altman analyses were used to determine if an air bubble model or a hemorrhage model was better correlated to the clinical data. The model was used to inject bubbles into clean PRF phase data without artifacts to examine how temperature profile distortions change with slice orientation. The simulated air-bubble injected data were compared to clinical data containing artifacts to examine the bubbles' effects on temperature and thermal damage estimates. RESULTS: The model demonstrated that air bubbles up to approximately 1 cm in diameter could explain the clinically observed phase artifacts. The bubble model predicts that a hemorrhage would have to be 2.2 times as large as an air bubble in order to explain the same extent of phase distortion observed in clinical data. Air bubbles had 16% percent higher correlations to the clinical PRF phase data than hemorrhages, even after rescaling the hemorrhage phases to better match the data. The air bubble model also explains how the phase artifacts lead to both large positive and large negative temperature errors, up to ±100 °C, which could cascade to damage estimate errors of several millimeters. CONCLUSION: Results showed that the artifacts are likely caused by air bubbles rather than hemorrhages, which may be introduced before heating or appear during heating. Manufacturers and users of devices that rely upon PRF-shift thermometry should be aware these phase distortions from bubble artifacts can result in large temperature errors.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Lasers , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos , Temperatura
8.
bioRxiv ; 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36909495

RESUMO

Focused ultrasound blood-brain barrier (BBB) opening is a promising tool for targeted delivery of therapeutic agents into the brain. The volume of opening determines the extent of therapeutic administration and sets a lower bound on the size of targets which can be selectively treated. We tested a custom 1 MHz array transducer optimized for cortical regions in the macaque brain with the goal of achieving small volume openings. We integrated this device into a magnetic resonance image guided focused ultrasound system and demonstrated twelve instances of small volume BBB opening with average opening volumes of 59 ± 37 mm 3 and 184 ± 2 mm 3 in cortical and subcortical targets, respectively. We developed real-time cavitation monitoring using a passive cavitation detector embedded in the array and characterized its performance on a bench-top flow phantom mimicking transcranial BBB opening procedures. We monitored cavitation during in-vivo procedures and compared cavitation metrics against opening volumes and safety outcomes measured with FLAIR and susceptibility weighted MR imaging. Our findings show small BBB opening at cortical targets in macaques and characterize the safe pressure range for 1 MHz BBB opening. Additionally, we used subject-specific simulations to investigate variance in measured opening volumes and found high correlation (R 2 = 0.8577) between simulation predictions and observed measurements. Simulations suggest the threshold for 1 MHz BBB opening was 0.53 MPa. This system enables BBB opening for drug delivery and gene therapy to be targeted to more specific brain regions.

9.
Magn Reson Med ; 89(6): 2227-2241, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36708203

RESUMO

PURPOSE: To achieve high-resolution multishot echo-planar imaging (EPI) for functional MRI (fMRI) with reduced sensitivity to in-plane motion and between-shot phase variations. METHODS: Two-dimensional radiofrequency pulses were incorporated in a multishot EPI sequence at 7T which selectively excited a set of in-plane bands (shutters) in the phase encoding direction, which moved between shots to cover the entire slice. A phase- and motion-corrected reconstruction was implemented for the acquisition. Brain imaging experiments were performed with instructed motion to evaluate image quality for conventional multishot and shuttered EPI. Temporal stability was assessed in three subjects by quantifying temporal SNR (tSNR) and artifact levels, and fMRI activation experiments using visual stimulation were performed to assess the strength and distribution of activation, using both conventional multishot and shuttered EPI. RESULTS: In the instructed motion experiment, ghosting was lower in shuttered EPI images without or with corrections and image quality metrics were improved with motion correction. tSNR was improved by phase correction in both conventional multishot and shuttered EPI and the acquisitions had similar tSNR without and with phase correction. However, while phase correction was necessary to maximize tSNR in conventional multishot EPI, it also increased intermittent ghosting, but did not increase intermittent ghosting in shuttered EPI. Phase correction increased activation strength in both conventional multishot and shuttered EPI, but caused increased spurious activation outside the brain and in frontal brain regions in conventional multishot EPI. CONCLUSION: Shuttered EPI supports multishot segmented EPI acquisitions with lower sensitivity to artifacts from motion for high-resolution fMRI.


Assuntos
Algoritmos , Imagem Ecoplanar , Humanos , Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Movimento (Física) , Artefatos , Processamento de Imagem Assistida por Computador/métodos
10.
Magn Reson Med ; 89(2): 729-737, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36161670

RESUMO

PURPOSE: To calculate temperatures from T2 *-weighted images collected during optogenetic fMRI based on proton resonance frequency (PRF) shift thermometry, to monitor confounding heating effects and determine appropriate light parameters for optogenetic stimulation. METHODS: fMRI is mainly based on long-TE gradient-recalled echo acquisitions that are also suitable for measuring small temperature changes via the PRF shift. A motion- and respiration-robust processing pipeline was developed to calculate temperature changes based on the PRF shift directly from the T2 *-weighted images collected for fMRI with a two-shot 2D gradient-recalled echo-EPI sequence at 9.4T. Optogenetic fMRI protocols which differed in stimulation durations (3, 6 and 9 s) within a total block duration of 30 s were applied in a squirrel monkey to validate the methods with blue and green light (20 Hz, 30 mW) delivery interleaved between periods. General linear modeling was performed on the resulting time series temperature maps to verify if light delivery with each protocol resulted in significant heating in the brain around the optical fiber. RESULTS: The temperature SD was 0.05°C with the proposed imaging protocol and processing. Statistical analysis showed that the optogenetic stimulation protocol with a 3 s stimulation duration did not result in significant temperature rises. Significant temperature rises up to 0.13°C (p < 0. 05) were observed with 6 and 9 s stimulation durations for blue and green light. CONCLUSION: The proposed processing pipeline can be useful for the design of optogenetic stimulation protocols and for monitoring confounding heating effects.


Assuntos
Imageamento por Ressonância Magnética , Optogenética , Imageamento por Ressonância Magnética/métodos , Calefação , Encéfalo/diagnóstico por imagem , Prótons , Lasers , Imagens de Fantasmas
11.
Brain Stimul ; 15(6): 1552-1564, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36496128

RESUMO

We have previously shown that focused ultrasound (FUS) pulses in low pressure range exerted bidirectional and brain state-dependent neuromodulation in the nonhuman primate somatosensory cortices by fMRI. Here we aim to gain insights about the proposed neuron selective modulation of FUS and probe feedforward versus feedback interactions by simultaneously quantifying the stimulus (FUS pressures: 925, 425, 250 kPa) and response (% BOLD fMRI changes) function at the targeted area 3a/3b and off-target cortical areas at 7T. In resting-state, lowered intensities of FUS resulted in decreased fMRI signal changes at the target area 3a/3b and off-target area 1/2, S2, MCC, insula and auditory cortex, and no signal difference in thalamic VPL and MD nuclei. In activated states, concurrent high-intensity FUS significantly enhanced touch-evoked signals in area 1/2. Medium- and low-intensity FUS significantly suppressed touch-evoked BOLD signals in all areas except in the auditory cortex, VPL and MD thalamic nuclei. Distinct state dependent and dose-response curves led us to hypothesize that FUS's neuromodulatory effects may be mediated through preferential activation of different populations of neurons. Area 3a/3b may have distinct causal feedforward and feedback interactions with Area 1/2, S2, MCC, insula, and VPL. FUS offers a noninvasive neural stimulation tool for dissecting brain circuits and probing causal functional connections.


Assuntos
Encéfalo , Percepção do Tato , Animais , Encéfalo/diagnóstico por imagem , Córtex Somatossensorial/fisiologia , Mapeamento Encefálico , Tato/fisiologia , Imageamento por Ressonância Magnética/métodos
12.
Magn Reson Med ; 88(6): 2419-2431, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35916311

RESUMO

PURPOSE: To rapidly image and localize the focus in MR-guided focused ultrasound (FUS) while maintaining a low ultrasound duty cycle to minimize tissue effects. METHODS: MR-acoustic radiation force imaging (ARFI) is key to targeting FUS procedures such as neuromodulation, and works by encoding ultrasound-induced displacements into the phase of MR images. However, it can require long scan times to cover a volume of tissue, especially when minimizing the FUS dose during targeting is paramount. To simultaneously minimize scan time and the FUS duty cycle, a 2-min three-dimensional (3D) reduced-FOV spin echo ARFI scan with two-dimensional undersampling was implemented at 3T with a FUS duty cycle of 0.85%. The 3D k-space sampling scheme incorporated uniform undersampling in one phase-encoded axis and partial Fourier (PF) sampling in the other. The scan interleaved FUS-on and FUS-off data collection to improve displacement map quality via a joint low-rank image reconstruction. Experiments in agarose and graphite phantoms and living macaque brains for neuromodulation and blood-brain barrier opening studied the effects of the sampling and reconstruction strategy on the acquisition, and evaluated its repeatability and accuracy. RESULTS: In the phantom, the distances between displacement centroids of 10 prospective reconstructions and a fully sampled reference were below 1 mm. In in vivo brain, the distances between centroids ranged from 1.3 to 2.1 mm. Results in phantom and in vivo brain both showed that the proposed method can recover the FUS focus compared to slower fully sampled scans. CONCLUSION: The proposed 3D MR-ARFI reduced-FOV method enables rapid imaging of the FUS focus while maintaining a low FUS duty cycle.


Assuntos
Grafite , Acústica , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Estudos Prospectivos , Sefarose
13.
JASA Express Lett ; 2(6): 062001, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35782333

RESUMO

Localizing the focus during transcranial focused ultrasound procedures is important to ensure accurate targeting of specific brain regions and interpretation of results. Magnetic resonance acoustic radiation force imaging uses the displacement induced by the ultrasound focus in the brain to localize the beam, but the high pressure required to displace brain tissue may cause damage or confounds during subsequent neuromodulatory experiments. Here, reduced apertures were applied to a phased array transducer to generate comparable displacement to the full aperture but with 20% lower free field pressure.

14.
NMR Biomed ; 35(11): e4793, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772938

RESUMO

The purpose of the current study was to implement unequal microstrip power splitters for parallel transmission at 7 T that are optimized for size and loss and that can be configured for a wide range of power ratios. The splitters will enable the use of more transmit coils without a corresponding increase in the number of transmit channels or amplifiers to control specific absorption rate, shorten RF pulses, and shim inhomogeneous RF fields. Wilkinson unequal power splitters based on a novel microstrip network design were optimized to minimize their size under 8 cm in length and 9 cm in width, enabling them to be included in coil housing or cascaded in multiple stages. Splitters were designed and constructed for a wide range of output power ratios at 298 MHz. Simulations and bench tests were performed for each ratio, and a methodology was established to adapt the designs to other ratios and frequencies. The designs and code are open source and can be reproduced as is or reconfigured. The single-stage designs achieved good matches and isolations between output ports (worst isolation -15.9 dB, worst match -15.1 dB). A two-stage cascaded (one input to four outputs) power splitter with 1:2.5, 1:10, 1:3, and 1:6 ratio outputs was constructed. The worst isolation between output ports was -19.7 dB in simulation and the worst match of the three ports was -17.8 dB. The measured ratios for one- and two-stage boards were within 10% of the theoretical ratios. The power-handling capability of the smallest trace was approximately 70 W. Power loss for the one- and two-stage boards ranged from 1% to 3% in simulation compared with 5.1% to 7.2% on the bench. It was concluded that Wilkinson unequal microstrip power splitters can be implemented with a small board size (low height) and low loss, and across a wide range of output power ratios. The splitters can be cascaded in multiple stages while maintaining the expected ratios and low loss. This will enable the construction of large fixed transmit array-compression matrices with low loss.


Assuntos
Compressão de Dados , Imageamento por Ressonância Magnética , Amplificadores Eletrônicos , Simulação por Computador , Compressão de Dados/métodos , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
15.
Magn Reson Med ; 88(3): 1081-1097, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35468232

RESUMO

PURPOSE: To perform B1+$$ {B}_1^{+} $$ -selective excitation using the Bloch-Siegert shift for spatial localization. THEORY AND METHODS: A B1+$$ {B}_1^{+} $$ -selective excitation is produced by an radiofrequency (RF) pulse consisting of two summed component pulses: an off-resonant pulse that induces a B1+$$ {B}_1^{+} $$ -dependent Bloch-Siegert frequency shift and a frequency-selective excitation pulse. The passband of the pulse can be tailored by adjusting the frequency content of the frequency-selective pulse, as in conventional B0$$ {B}_0 $$ gradient-localized excitation. Fine magnetization profile control is achieved by using the Shinnar-Le Roux algorithm to design the frequency-selective excitation pulse. Simulations analyzed the pulses' robustness to off-resonance, their suitability for multi-echo spin echo pulse sequences, and how their performance compares to that of rotating-frame selective excitation pulses. The pulses were evaluated experimentally on a 47.5 mT MRI scanner using an RF gradient transmit coil. Multiphoton resonances produced by the pulses were characterized and their distribution across B1+$$ {B}_1^{+} $$ predicted. RESULTS: With correction for varying B1+$$ {B}_1^{+} $$ across the desired profile, the proposed pulses produced selective excitation with the specified profile characteristics. The pulses were robust against off-resonance and RF amplifier distortion, and suitable for multi-echo pulse sequences. Experimental profiles closely matched simulated patterns. CONCLUSION: The Bloch-Siegert shift can be used to perform B0$$ {B}_0 $$ -gradient-free selective excitation, enabling the excitation of slices or slabs in RF gradient-encoded MRI.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Algoritmos , Amplificadores Eletrônicos , Imagens de Fantasmas
16.
IEEE Trans Biomed Eng ; 69(10): 3243-3252, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35404807

RESUMO

OBJECTIVE: High-density multi-coil arrays are desirable in MRI because they provide high signal-to-noise ratios (SNR), enable highly accelerated parallel imaging, and provide more uniform transmit fields at high fields. For high-density arrays such as a head array with 16 elements in a row, popular dipole antennas and microstrip transmission line (also referred to as "MTL") resonators both have severe coupling issues. METHODS: In this work, we show that dipoles and MTLs have naturally low coupling and propose a novel array configuration in which they are interleaved. We first show the electromagnetic (EM) coupling between a single dipole and a single MTL across different separations in bench tests. Then we validate and analyze this through EM simulations. Finally, we construct a 16-channel mixed dipole and MTL array and evaluate its performance on the bench and through MRI experiments. RESULTS: Without any decoupling treatments, the worst coupling between a dipole and an MTL was only -15.8 dB when their center-to-center distance was 4.7 cm (versus -5.4 dB for two dipole antennas and -6.0 dB for two MTL resonators). Even in a dense 16-channel mixed array, the inter-element isolation among all elements was better than -14 dB. CONCLUSION: This study reveals, analyzes, and validates a novel finding that the popular dipole antennas and MTL resonators used in ultrahigh field MRI have naturally low coupling. SIGNIFICANCE: These findings will simplify the construction of high-density arrays, enable new applications, and benefit imaging performance in ultrahigh field MRI.


Assuntos
Imageamento por Ressonância Magnética , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
17.
Sci Rep ; 12(1): 4006, 2022 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-35256627

RESUMO

The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm3, 2 × 2 × 3 mm3, and 3 × 3 × 3 mm3) and three temporal resolutions (0.48, 0.72, and 0.97 s) with undersampling acceleration factors ranging from 2 to 17. The combination of radial golden angle GRE acquisition, simultaneous catheter tracking, intra-scan 2D motion correction, and undersampled thermometry enabled temperature monitoring in the myocardium in vivo during RF ablations with high temporal (< 1 s) and high spatial resolution. The temperature uncertainty ranged from 0.2 ± 0.1 to 1.8 ± 0.2 °C for the various temporal and spatial resolutions and, on average, remained superior to the uncertainty of an EPI acquisition while still allowing clinical monitoring of the RF ablation process. The proposed method is a robust and promising alternative to EPI acquisition to monitor in vivo RF cardiac ablations. Further studies remain required to improve the temperature uncertainty and establish its clinical applicability.


Assuntos
Ablação por Cateter , Termometria , Animais , Ablação por Cateter/métodos , Catéteres , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ovinos , Termometria/métodos
18.
IEEE Trans Med Imaging ; 41(6): 1420-1430, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34990352

RESUMO

Balun or trap circuits are critical components for suppressing common-mode currents flowing on the outer conductors of coaxial cables in RF coil systems for Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS). Common-mode currents affect coils' tuning and matching, induce losses, pick up extra noise from the surrounding environment, lead to undesired cross-talk, and cause safety concerns in animal and human imaging. First proposed for microwave antenna applications, the Lattice balun has been widely used in MRI coils. It has a small footprint and can be easily integrated with coil tuning/matching circuits. However, the Lattice balun is typically a single-tuned circuit and cannot be used for multi-nuclear MRI and MRS with two RF frequencies. This work describes a dual-tuned Lattice balun design that is suitable for multi-nuclear MRI/MRS. It was first analyzed theoretically to derive component values. RF circuit simulations were then performed to validate the theoretical analysis and provide guidance for practical construction. Based on the simulation results, a dual-tuned balun circuit was built for 7T 1H/23Na MRI and bench tested. The fabricated dual-tuned balun exhibits superior performance at the Larmor frequencies of both 1H and 23Na, with less than 0.15 dB insertion loss and better than 17 dB common-mode rejection ratio at both frequencies.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas
19.
Magn Reson Med ; 87(2): 614-628, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34480778

RESUMO

PURPOSE: Point-of-care MRI requires operation outside of Faraday shielded rooms normally used to block image-degrading electromagnetic interference (EMI). To address this, we introduce the EDITER method (External Dynamic InTerference Estimation and Removal), an external sensor-based method to retrospectively remove image artifacts from time-varying external interference sources. THEORY AND METHODS: The method acquires data from multiple EMI detectors (tuned receive coils as well as untuned electrodes placed on the body) simultaneously with the primary MR coil during and between image data acquisition. We calculate impulse response functions dynamically that map the data from the detectors to the time varying artifacts then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80 mT portable brain MRI in a controlled EMI environment and with an open 47.5 mT MRI scanner in an uncontrolled EMI setting. RESULTS: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI in phantom experiments. In the uncontrolled EMI experiments, we demonstrate EMI reductions of up to 99% using an electrode and pick-up coil in vivo. We demonstrate up to a nine-fold improvement in image SNR with the method. CONCLUSION: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding and could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Algoritmos , Imagens de Fantasmas , Estudos Retrospectivos
20.
Magn Reson Med ; 86(6): 3382-3390, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34286860

RESUMO

PURPOSE: A ratio adjustable power splitter (RAPS) circuit was recently proposed for add-on RF shimming and array-compressed parallel transmission. Here we propose a new RAPS circuit design based on off-the-shelf components for improved performance and manufacturability. THEORY AND METHODS: The original RAPS used a pair of home-built Wilkinson splitter and hybrid coupler connected by a pair of connectorized coaxial cables. Here we propose a new hybrid-pair RAPS (or HP-RAPS) circuit that replaces the home-built circuits with two commercially available hybrid couplers and replaces connectorized cables with interchangeable microstrip lines. We derive the relation between the desired splitting ratio and the required phase shifts for HP-RAPS and investigate how to generate arbitrary splitting ratios using paired meandering and straight lines. Several HP-RAPSs with different splitting ratios were fabricated and tested on the workbench and MRI experiments. RESULTS: The splitting ratio of an HP-RAPS circuit has a tan or cot dependence on the meandering line's additional length compared to the straight line. The fabricated HP-RAPSs exhibit accurate splitting ratios as expected (<4% deviations) and generate transmit fields that well agree with predicted fields. They also demonstrated a low insertion loss of 0.33 dB, high output isolation of -26 dB, and acceptable impedance matching of -16 dB. CONCLUSION: A novel HP-RAPS circuit was developed and implemented. It is easy-to-fabricate/reproduce with minimal expertise. It also preserves the features of the original RAPS circuit (ratio-adjustable, small footprint, etc.) with lower insertion loss.


Assuntos
Imageamento por Ressonância Magnética , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA