Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Bioanalysis ; 14(12): 853-863, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35703321

RESUMO

Gene therapy, cell therapy and vaccine research have led to an increased use of qPCR/ddPCR in bioanalytical laboratories. CROs are progressively undertaking the development and validation of qPCR and ddPCR assays. Currently, however, there is limited regulatory guidance for the use of qPCR and a complete lack of any regulatory guidelines for the use of the newer ddPCR to support regulated bioanalysis. Hence, the Global CRO Council in Bioanalysis (GCC) has issued this White Paper to provide; 1) a consensus on the different validation parameters required to support qPCR/ddPCR assays; 2) a harmonized approach to their validation and 3) a consistent development of standard operating procedures (SOPs) for all the bioanalytical laboratories using these techniques.


Assuntos
Bioensaio , Reação em Cadeia da Polimerase em Tempo Real/métodos
2.
AAPS J ; 24(2): 42, 2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-35288790

RESUMO

The COVID-19 pandemic has strained the biological matrix supply chain. An upsurge in demand driven by numerous COVID-19 therapeutic and vaccine development programs to combat the pandemic, along with logistical challenges sourcing and transporting matrix, has led to increased lead times for multiple matrices. Biological matrix shortages can potentially cause significant delays in drug development programs across the pharmaceutical and biotechnology industry. Given the current circumstances, discussion is warranted around what will likely be increased use of surrogate matrices in support of pharmacokinetic (PK), immunogenicity, and biomarker assays for regulatory filings. Regulatory authorities permit the use of surrogate matrix in bioanalytical methods in instances where matrix is rare or difficult to obtain, as long as the surrogate is appropriately selected and scientifically justified. Herein, the scientific justification and possible regulatory implications of employing surrogate matrix in PK, immunogenicity, and biomarker assays are discussed. In addition, the unique challenges that cell and gene therapy (C>) and other innovative therapeutic modalities place on matrix supply chains are outlined. Matrix suppliers and contract research organizations (CROs) are actively implementing mitigation strategies to alleviate the current strain on the matrix supply chain and better prepare the industry for any future unexpected strains. To maintain ethical standards, these mitigation strategies include projecting matrix needs with suppliers at least 6 months in advance and writing or updating study protocols to allow for additional matrix draws from study subjects and/or re-purposing of subject matrix from one drug development program to another.


Assuntos
COVID-19 , Pandemias , Humanos
3.
Bioanalysis ; 14(4): 187-193, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35135309

RESUMO

Gene therapy, cell therapy and vaccine research have led to an increased need to perform cellular immunity testing in a regulated environment to ensure the safety and efficacy of these treatments. The most common method for the measurement of cellular immunity has been Enzyme-Linked Immunospot assays. However, there is a lack of regulatory guidance available discussing the recommendations for developing and validating these types of assays. Hence, the Global CRO Council has issued this white paper to provide a consensus on the different validation parameters required to support Enzyme-Linked Immunospot assays and a harmonized and consistent approach to Enzyme-Linked Immunospot validation among contract research organizations.


Assuntos
Bioensaio/métodos , Terapia Baseada em Transplante de Células e Tecidos/métodos , ELISPOT/métodos , Terapia Genética/métodos , Humanos
4.
Bioanalysis ; 13(8): 609-619, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33847160

RESUMO

The 13th Global CRO Council (GCC) closed forum for bioanalysis was held in New Orleans, LA, USA on 5 April 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. While ICH M10 will cover requirements for reference standards, one of the biggest challenges facing the CRO community is the lack of consistency and completeness of Certificates of Analysis for reference standards used in regulated bioanalysis. Similar challenges exist with critical reagents (e.g., capture and detection antibodies) used for assays supporting biologics. The recommendations provided in this publication are the minimum requirements for the content that GCC members believe should be included in Certificates of Analysis for reference standards obtained from commercial vendors, sponsors and compendial suppliers, for use in regulated bioanalytical studies. In addition, recommendations for internal standards, metabolites and critical reagents are discussed.


Assuntos
Anticorpos/análise , Bioensaio/normas , Humanos , Padrões de Referência
5.
Bioanalysis ; 8(4): 259-64, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26853375

RESUMO

Boston Society's 11th Annual Applied Pharmaceutical Analysis conference, Hyatt Regency Hotel, Cambridge, MA, USA, 14-16 September 2015 The Boston Society's 11th Annual Applied Pharmaceutical Analysis (APA) conference took place at the Hyatt Regency hotel in Cambridge, MA, on 14-16 September 2015. The 3-day conference affords pharmaceutical professionals, academic researchers and industry regulators the opportunity to collectively participate in meaningful and relevant discussions impacting the areas of pharmaceutical drug development. The APA conference was organized in three workshops encompassing the disciplines of regulated bioanalysis, discovery bioanalysis (encompassing new and emerging technologies) and biotransformation. The conference included a short course titled 'Bioanalytical considerations for the clinical development of antibody-drug conjugates (ADCs)', an engaging poster session, several panel and round table discussions and over 50 diverse talks from leading industry and academic scientists.


Assuntos
Técnicas de Química Analítica , Descoberta de Drogas , Biotransformação , Regulamentação Governamental , Humanos
6.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26916197

RESUMO

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Assuntos
Biomarcadores/análise , Medicamentos Biossimilares/análise , Avaliação Pré-Clínica de Medicamentos/métodos , Biomarcadores/sangue , Registros Eletrônicos de Saúde , Laboratórios , Sociedades Médicas , Estudos de Validação como Assunto
7.
J Chromatogr A ; 1325: 129-36, 2014 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-24377733

RESUMO

We present here a novel and highly sensitive ion-pair hydrophilic interaction chromatography-tandem mass spectrometry (IP-HILIC-MS/MS) method for quantitation of highly polar acid metabolites like adenine nucleotides. A mobile phase based on diethylamine (DEA) and hexafluoro-2-isopropanol (HFIP) and an aminopropyl (NH2) column were applied for a novel chromatographic separation for the determination of AMP, ADP and ATP in biological matrices. This novel IP-HILIC mechanism could be hypothesized by the ion-pairing reagent (DEA) in the mobile phase forming neutral and hydrophilic complexes with the analytes of polar organic acids. The IP-HILIC-MS/MS assay for adenine nucleotides was successfully validated with satisfactory linearity, sensitivity, accuracy, reproducibility and matrix effects. The lower limit of quantitation (LLOQ) at 2.00ng/mL obtained for ATP showed a least 10-fold higher sensitivity than previous LC-MS/MS assays except nano-LC-MS/MS assay. In summary, this novel IP-HILIC-MS/MS assay provides a sensitive method for nucleotides bioanalysis and shows great potential to determine a number of organic acids in biological matrices.


Assuntos
Nucleotídeos de Adenina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/instrumentação , Humanos , Íons/química , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/instrumentação
8.
Anal Chim Acta ; 750: 199-206, 2012 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-23062441

RESUMO

A range of organic solvents (ethanol, isopropanol and acetone) has been investigated as alternatives to acetonitrile and methanol when used in conjunction with Corona Charged Aerosol Detection (Corona CAD). These solvents have been evaluated with regard to their effect on the response of the Corona CAD. Three dimensional response surfaces were constructed using raw data showing the relationship between detector response, analyte concentration and percentage of organic solvent in the mobile phase, using sucralose or quinine as the test analyte. The detector response was non-linear in terms of analyte concentration for all solvents tested. However, detector response varied in an approximately linear manner with percentage of organic solvent over the range 0-40% for ethanol or isopropanol and 0-80% for acetone and methanol. The chromatographic performance of the various solvents when used as aqueous-organic mobile phases was evaluated for isocratic and gradient separations of sugars and sugar alcohols by hydrophilic interaction liquid chromatography (HILIC) using an Asahipak NH2P-504E column coupled with Corona CAD detection. It was found that whilst acetonitrile provided the highest column efficiencies and lowest detection limits of the solvents studied, acetone also performed well and could be used to resolve the same number of analytes as was possible with acetonitrile. Typical efficiencies and detection limits of 5330 plates m(-1) and 1.25 µg mL(-1), respectively, were achieved when acetone was used as the organic modifier. Acetone was utilised successfully as an organic modifier in the HILIC separation of carbohydrates in a beer sample and also for a partially digested dextran sample.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão , Solventes/química , 2-Propanol/química , Acetona/química , Acetonitrilas/química , Química Verde , Interações Hidrofóbicas e Hidrofílicas , Metanol/química
9.
J Chromatogr B Analyt Technol Biomed Life Sci ; 895-896: 186-90, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22483332

RESUMO

Measurement of endogenous epinephrine (E) and norepinephrine (NE) in human plasma is very challenging due to lower endogenous concentrations as compared with animal plasma. An LC-MS/MS in combination with alumina-based SPE and derivatization procedure was validated for the measurement of E and NE in human plasma with acceptable intra-day and inter-day accuracy and precision. Sample was extracted with semi-automated alumina 96-well solid phase extraction (SPE) cartridge. The resulting eluent was dried and derivatized using d4-acetaldehyde. The analytes were separated on a monolithic C(18) column. Extraction efficiencies were >66% for E and NE. The lower limit of quantitation (LLOQ) was 5.00 pg/mL for E and 20.0 pg/mL for NE.


Assuntos
Cromatografia Líquida/métodos , Epinefrina/sangue , Norepinefrina/sangue , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Epinefrina/química , Epinefrina/isolamento & purificação , Humanos , Limite de Detecção , Norepinefrina/química , Norepinefrina/isolamento & purificação , Reprodutibilidade dos Testes
10.
Anal Biochem ; 421(2): 556-65, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22107886

RESUMO

Fatty acid amide hydrolase (FAAH) is one of the main enzymes responsible for the degradation of the endocannabinoid anandamide (N-arachidonoylethanolamine, AEA). FAAH inhibitors may be useful in treating many disorders involving inflammation and pain. Although brain FAAH may be the relevant target for inhibition, rat studies show a correlation between blood and brain FAAH inhibition, allowing blood FAAH activity to be used as a target biomarker. Building on experience with a rat leukocyte FAAH activity assay using [³H]AEA, we have developed a human leukocyte assay using stably labeled [²H4]AEA as substrate. The deuterium-labeled ethanolamine reaction product ([²H4]EA) was analyzed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) in the positive electrospray ionization (ESI) mode. The response for [²H4]EA was linear from 10 nM to 10 µM, and the analysis time was less than 6 min/sample. Results using the [²H4]AEA and HPLC-MS/MS method agreed well with those obtained using the [³H]AEA radiometric assay. In addition to using a nonradioactive substrate, the HPLC-MS/MS method had increased sensitivity with lower background. Importantly, the assay preserved partial FAAH inhibition resulting from ex vivo treatment with a time-dependent irreversible inhibitor, suggesting its utility with clinical samples. The assay has been used to profile the successful inhibition of FAAH in recent clinical trials.


Assuntos
Amidoidrolases/sangue , Cromatografia Líquida de Alta Pressão/métodos , Leucócitos/enzimologia , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Amidoidrolases/antagonistas & inibidores , Biomarcadores/sangue , Humanos
11.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(22): 2023-33, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21684223

RESUMO

A UPLC-MS/MS assay was developed and validated for simultaneous quantification of acetylcholine (ACh), histamine (HA), tele-methylhistamine (t-mHA), and tele-methylimidazolacetic acid (t-MIAA) in rat cerebrospinal fluid (CSF). The biological stability of ACh in rat CSF was investigated. Following fit-for-purpose validation, the method was applied to monitor the drug-induced changes in ACh, HA, t-mHA, and t-MIAA in rat CSF following administration of donepezil or prucalopride. The quantitative method utilizes hydrophilic interaction chromatography (HILIC) Core-Shell HPLC column technology and a UPLC system to achieve separation with detection by positive ESI LC-MS/MS. This UPLC-MS/MS method does not require extraction or derivatization, utilizes a stable isotopically labeled internal standard (IS) for each analyte, and allows for rapid throughput with a 4 min run time. Without an acetylcholinesterase (AChE) inhibitor present, ACh was found to have 1.9±0.4 min in vitro half life in rat CSF. Stability studies and processing modification, including the use of AChE inhibitor eserine, extended this half life to more than 60 min. The UPLC-MS/MS method, including stabilization procedure, was validated over a linear concentration range of 0.025-5 ng/mL for ACh and 0.05-10 ng/mL for HA, t-mHA, and t-MIAA. The intra-run precision and accuracy for all analytes were 1.9-12.3% CV and -10.2 to 9.4% RE, respectively, while inter-run precision and accuracy were 4.0-16.0% CV and -5.3 to 13.4% RE, respectively. By using this developed and validated method, donepezil caused increases in ACh levels at 0.5, 1, 2, and 4h post dose as compared to the corresponding vehicle group, while prucalopride produced approximately 1.6- and 3.1-fold increases in the concentrations of ACh and t-mHA at 1h post dose, respectively, compared to the vehicle control. Overall, this methodology enables investigations into the use of CSF ACh and HA as biomarkers in the study of these neurotransmitter systems and related drug discovery efforts.


Assuntos
Acetilcolina/líquido cefalorraquidiano , Cromatografia Líquida de Alta Pressão/métodos , Histamina/líquido cefalorraquidiano , Imidazóis/líquido cefalorraquidiano , Espectrometria de Massas em Tandem/métodos , Acetilcolina/metabolismo , Acetilcolina/farmacocinética , Animais , Benzofuranos/líquido cefalorraquidiano , Benzofuranos/química , Benzofuranos/farmacologia , Inibidores da Colinesterase/farmacologia , Donepezila , Estabilidade de Medicamentos , Histamina/metabolismo , Histamina/farmacocinética , Interações Hidrofóbicas e Hidrofílicas , Imidazóis/farmacocinética , Indanos/farmacologia , Masculino , Metilistaminas/líquido cefalorraquidiano , Metilistaminas/farmacocinética , Piperidinas/farmacologia , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Chromatogr A ; 1218(12): 1646-55, 2011 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-21315361

RESUMO

The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 µL.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão/métodos , Nebulizadores e Vaporizadores , Cromatografia Líquida de Alta Pressão/instrumentação , Luz , Modelos Químicos , Espalhamento de Radiação , Sensibilidade e Especificidade , Temperatura
13.
J Chromatogr A ; 1217(47): 7418-27, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-20961549

RESUMO

The universality of the response of the Corona Charged Aerosol Detector (CoronaCAD) has been investigated under flow-injection and gradient HPLC elution conditions. A three-dimensional model was developed which relates the CoronaCAD response to analyte concentration and the mobile phase composition used. The model was developed using the response of four probe analytes which displayed non-volatile behavior in the CoronaCAD and were soluble over a broad range of mobile phase compositions. The analyte concentrations ranged from 1µg/mL to 1mg/mL, and injection volumes corresponded to on-column amounts of 25ng to 25µg. Mobile phases used in the model were composed of 0-80% acetonitrile, mixed with complementary proportions of aqueous formic acid (0.1%, pH 2.6). An analyte set of 23 compounds possessing a wide range of physicochemical properties was selected for the purpose of evaluating the model. The predicted response was compared to the actual analyte response displayed by the detector and the efficacy of the model under flow-injection and gradient HPLC elution conditions was determined. The average error of the four analytes used to develop the model was 9.2% (n=176), while the errors under flow-injection and gradient HPLC elution conditions for the evaluation set of analytes were found to be 12.5% and 12.8%, respectively. Some analytes were excluded from the evaluation set due to considerations of volatility (boiling point <400°C), charge and excessive retention on the column leading to elution outside the eluent range covered by the model. The two-part response model can be used to describe the relationship between response and analyte concentration and also to offer a correction for the non-linear detector response obtained with gradient HPLC for analytes which conform to the model, to provide insight into the factors affecting the CoronaCAD response for different analytes, and also as a means for accurately determining the concentration of unknown compounds when individual standards are not available for calibration.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão/instrumentação
14.
Rapid Commun Mass Spectrom ; 24(13): 1902-10, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20533320

RESUMO

During routine liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis of a small molecule analyte in rat serum samples from a toxicokinetic study, an unexpected interfering peak was observed in the extracted ion chromatogram of the internal standard. No interfering peaks were observed in the extracted ion chromatogram of the analyte. The dose-dependent peak area response and peak area response versus time profiles of the interfering peak suggested that it might have been related to a metabolite of the dosed compound. Further investigation using high-resolution mass spectrometry led to unequivocal identification of the interfering peak as an N-desmethyl metabolite of the parent analyte. High-resolution mass spectrometry (HRMS) was also used to demonstrate that the interfering response of the metabolite in the multiple reaction monitoring (MRM) channel of the internal standard was due to an isobaric relationship between the (13)C-isotope of the metabolite and the internal standard (i.e., common precursor ion mass), coupled with a metabolite product ion with identical mass to the product ion used in the MRM transition of the internal standard. These results emphasize (1) the need to carefully evaluate internal standard candidates with regard to potential interferences from metabolites during LC/MS/MS method development, validation and bioanalysis of small molecule analytes in biological matrices; (2) the value of HRMS as a tool to investigate unexpected interferences encountered during LC/MS/MS analysis of small molecules in biological matrices; and (3) the potential for interference regardless of choice of IS and therefore the importance of conducting assay robustness on incurred in vitro or in vivo study samples.


Assuntos
Cromatografia Líquida/métodos , Farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Relação Dose-Resposta a Droga , Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Ratos , Ratos Sprague-Dawley , Padrões de Referência
15.
J Pharm Biomed Anal ; 50(3): 491-500, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19540084

RESUMO

The chromatographic performance of fused-core (superficially porous) HPLC packing materials was compared with conventional fully porous particle materials for LC-MS/MS analysis of two pharmaceuticals in rat plasma. Two commercially available antidepressants, imipramine and desipramine, were assayed using a conventional analytical C(18) column (5 microm, 2.0 mm x 30 mm) and a fused-core C(18) column (2.7 microm, 2.1 mm x 30 mm). Retention time, column efficiency, pressure drop, resolution, and loading capacity were compared under the same operating conditions. The fused-core column demonstrated reduced assay time by 34% and 2-3-fold increased efficiency (N). Loading capacity up to 25 microl of extract injected on column showed no peak distortion. The registered back-pressure from a flow rate of 1.0 ml/min did not exceed 3400 psi making it compatible with standard HPLC equipment (typically rated to 6000 psi). Two mobile phases were examined, and morpholine as an organic base modifier yielded a 2-5-fold increase in S/N near the limit of detection over triethylamine. The 2.7 microm fused-core column was applied to the analysis of imipramine and desipramine in extracted, protein precipitated rat plasma by LC-MS/MS. The calibration curves were linear in the concentration range of 0.5-1000 ng/ml for both imipramine and desipramine. Intra-run precisions (%CV) and accuracies (%bias) were within +/-7.8% and +/-7.3% at three QC levels and within 14.7% and 14.4% at the LOQ level for both analytes. Following a single method qualification run, the method was applied to the quantitation of pharmacokinetic study samples after oral administration of imipramine to male rats.


Assuntos
Cromatografia Líquida/métodos , Desipramina/farmacocinética , Imipramina/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Antidepressivos Tricíclicos/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Masculino , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA