Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 47(5): 533-542, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565717

RESUMO

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.


Assuntos
Simulação por Computador , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem
2.
Drug Deliv ; 30(1): 2226366, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37341184

RESUMO

[Purpose] Transarterial radioembolization (TARE) is an established treatment modality for patients with unresectable liver cancer. However, a better understanding of treatment parameters that influence microsphere distribution could further improve the therapy. This systematic review examines and summarizes the available evidence on intraprocedural parameters that influence the microsphere distribution during TARE as investigated by in vivo, ex vivo, in vitro and in silico studies. [Methods] A standardized search was performed in Medline, Embase and Web of Science to identify all published articles investigating microsphere distribution or dynamics during TARE. Studies presenting original research on parameters influencing the microsphere distribution during TARE were included. [Results] A total of 42 studies reporting a total of 11 different parameters were included for narrative analysis. The investigated studies suggest that flow distribution is not a perfect predictor of microsphere distribution. Increasing the injection velocity may help increase the similarity between flow and microsphere distributions. Furthermore, the microsphere distributions are very sensitive to the radial and axial catheter position. [Conclusion] The most promising parameters for future research which can be controlled in the clinic appear to be microsphere injection velocity as well as the axial catheter position. Up to now, many of the included studies do not take clinical feasibility into account, limiting the translation of results to clinical settings. Future research should therefore focus on the applicability of in vivo, in vitro, or in silico research to patient specific scenarios to improve the efficacy of radioembolization as treatment for liver cancer.


Assuntos
Neoplasias Hepáticas , Humanos , Microesferas , Neoplasias Hepáticas/radioterapia
3.
Cardiovasc Intervent Radiol ; 45(6): 858-866, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35378613

RESUMO

PURPOSE: The feasibility of using a compressed interwoven Supera stent as a flow diverting device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however, what the optimal flow diverting strategy is, because of the fusiform shape of popliteal aneurysms and their exposure to triphasic flow. To assess this flow diverting strategy for popliteal aneurysms, flow profiles and thrombus formation likelihood were investigated in popliteal aneurysm models. MATERIALS AND METHODS: Six popliteal aneurysm models were created and integrated into a pulsatile flow set-up. These models covered a bent and a straight anatomy in three configurations: control, single-lined and dual-lined Supera stents. Two-dimensional flow velocities were visualized by laser particle image velocimetry. In addition, the efficacy of the stent configurations for promoting aneurysm thrombosis was assessed by simulations of residence time and platelet activation. RESULTS: On average for the two anatomies, the Supera stent led to a twofold reduction of velocities in the aneurysm for single-lined stents, and a fourfold reduction for dual-lined stents. Forward flow was optimally diverted, whereas backward flow was generally deflected into the aneurysm. The dual-lined configuration led to residence times of 15-20 s, compared to 5-15 s for the single stent configurations. Platelet activation potential was not increased by the flow diverting stents. CONCLUSION: A compressed Supera stent was successfully able to divert flow in a popliteal aneurysm phantom. A dual-lined configuration demonstrated superior hemodynamic characteristics compared to its single-lined counterpart.


Assuntos
Aneurisma , Artéria Poplítea , Ligas , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Humanos , Artéria Poplítea/diagnóstico por imagem , Desenho de Prótese , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA