Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
PLoS One ; 19(3): e0292203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38446766

RESUMO

Considering sex as a biological variable in modern digital health solutions, we investigated sex-specific differences in the trajectory of four physiological parameters across a COVID-19 infection. A wearable medical device measured breathing rate, heart rate, heart rate variability, and wrist skin temperature in 1163 participants (mean age = 44.1 years, standard deviation [SD] = 5.6; 667 [57%] females). Participants reported daily symptoms and confounders in a complementary app. A machine learning algorithm retrospectively ingested daily biophysical parameters to detect COVID-19 infections. COVID-19 serology samples were collected from all participants at baseline and follow-up. We analysed potential sex-specific differences in physiology and antibody titres using multilevel modelling and t-tests. Over 1.5 million hours of physiological data were recorded. During the symptomatic period of infection, men demonstrated larger increases in skin temperature, breathing rate, and heart rate as well as larger decreases in heart rate variability than women. The COVID-19 infection detection algorithm performed similarly well for men and women. Our study belongs to the first research to provide evidence for differential physiological responses to COVID-19 between females and males, highlighting the potential of wearable technology to inform future precision medicine approaches.


Assuntos
COVID-19 , Masculino , Humanos , Feminino , Adulto , COVID-19/diagnóstico , Estudos Retrospectivos , SARS-CoV-2 , Algoritmos , Biofísica
2.
Adv Clin Chem ; 116: 31-111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37852722

RESUMO

There is a need for blood biomarkers to detect individuals at different Alzheimer's disease (AD) stages because obtaining cerebrospinal fluid-based biomarkers is invasive and costly. Plasma phosphorylated tau proteins (p-tau) have shown potential as such biomarkers. This systematic review was conducted according to the PRISMA guidelines and aimed to determine whether quantification of plasma tau phosphorylated at threonine 181 (p-tau181), threonine 217 (p-tau217) and threonine 231 (p-tau231) is informative in the diagnosis of AD. All p-tau isoforms increase as a function of Aß-accumulation and discriminate healthy individuals from those at preclinical AD stages with high accuracy. P-tau231 increases earliest, followed by p-tau181 and p-tau217. In advanced stages, all p-tau isoforms are associated with the clinical classification of AD and increase with disease severity, with the greatest increase seen for p-tau217. This is also reflected by a better correlation of p-tau217 with Aß scans, whereas both, p-tau217 and p-tau181 correlated equally with tau scans. However, at the very advanced stages, p-tau181 begins to plateau, which may mirror the trajectory of the Aß pathology and indicate an association with a more intermediate risk of AD. Across the AD continuum, the incremental increase in all biomarkers is associated with structural changes in widespread brain regions and underlying cognitive decline. Furthermore, all isoforms differentiate AD from non-AD neurodegenerative disorders, making them specific for AD. Incorporating p-tau181, p-tau217 and p-tau231 in clinical use requires further studies to examine ideal cut-points and harmonize assays.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Humanos , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides , Biomarcadores , Isoformas de Proteínas , Proteínas tau , Treonina
3.
Diagnostics (Basel) ; 13(18)2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37761305

RESUMO

The soluble urokinase plasminogen activator receptor (suPAR), as a correlate of chronic low-grade inflammation, may be used to predict individual cardiovascular risk. Since chronic low-grade inflammation is thought to be associated with the development of cardiovascular disease, this study aimed to evaluate if suPAR plasma levels are correlated with cardiovascular risk factors in young and healthy adults (aged 25-41 years). Consequently, data from the GAPP (genetic and phenotypic determinants of blood pressure and other cardiovascular risk factors) study were used to investigate suPAR plasma levels in relation to the following cardiovascular risk factors and laboratory parameters: BMI, physical activity, alcohol consumption, smoking status, blood pressure parameters, glucose status, and lipid levels. Additionally, suPAR was compared to the healthy lifestyle score and the Framingham score representing the overall cardiovascular risk profile. These associations were assessed using two different statistical approaches. Firstly, all cardiovascular risk factors and scores were compared amongst sex-specific suPAR plasma levels with ANOVA analysis. Secondly, sex-specific multivariable linear regressions were performed. Female participants had higher plasma suPAR levels than male participants (1.73 ng/mL versus 1.50 ng/mL; p < 0.001). A significant inverse correlation between suPAR plasma levels and HDL cholesterol was found in men (p = 0.001) and women (p < 0.001). Furthermore, male (p < 0.001) and female participants (p < 0.001) who smoked showed significantly higher plasma levels of suPAR (p < 0.001). For male participants, an inverse correlation of the healthy lifestyle score with suPAR plasma levels (p = 0.001) and a positive correlation of the Framingham score with suPAR plasma levels (p < 0.001) were detected. In women, no such correlation was found. The cholesterol levels (p = 0.001) and HbA1c (p = 0.008) correlated significantly with plasma suPAR levels in female participants. suPAR plasma levels were found to be strongly associated with certain cardiovascular risk factors; however, sex-specific differences were found. These sex-specific differences might be explained by the higher prevalence of cardiovascular risk factors in men resulting in a stronger correlation of suPAR as a marker of low-grade inflammation, since the existence of the risk factors already led to subclinical damage in men. Further research on suPAR levels in an older study population is needed.

4.
Diagnostics (Basel) ; 13(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37443561

RESUMO

It is unknown whether neurological symptoms are associated with brain injury after SARS-CoV-2 infections and whether brain injury and related symptoms also emerge in Long-COVID patients. Biomarkers such as serum neurofilament light chain (sNfL) and glial fibrillary acidic protein (sGFAP) can be used to elucidate neuro-axonal and astroglial injuries. We investigated whether these biomarkers are associated with COVID-19 infection status, associated symptoms and Long-COVID. From 146 individuals of the general population with a post-acute, mild-to-moderate SARS-CoV-2 infection, sNfL and sGFAP were measured before, during and after (five and ten months) the infection. Individual symptoms and Long-COVID status were assessed using questionnaires. Neurological associated symptoms were described for individuals after a mild and moderate COVID-19 infection; however, sNfL (p = 0.74) and sGFAP (p = 0.24) did not change and were not associated with headache (p = 0.51), fatigue (p = 0.93), anosmia (p = 0.77) or ageusia (p = 0.47). In Long-COVID patients, sGFAP (p = 0.038), but not sNfL (p = 0.58), significantly increased but was not associated with neurological associated symptoms. Long-COVID status, but not post-acute SARS-CoV-2 infections, may be associated with astroglial injury/activation, even if neurological associated symptoms were not correlated.

5.
iScience ; 25(10): 105210, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36267918

RESUMO

Premature atrial contractions (PACs) are frequently observed on electrocardiograms and are associated with increased risks of atrial fibrillation (AF), stroke, and mortality. In this study, we aimed to identify genetic susceptibility loci for PAC frequency. We performed a genome-wide association study meta-analysis with PAC frequency obtained from ambulatory cardiac monitoring in 4,831 individuals of European ancestry. We identified a genome-wide significant locus at the SCN5A gene. The lead variant, rs7373862, located in an intron of SCN5A, was associated with an increase of 0.12 [95% CI 0.08-0.16] standard deviations of the normalized PAC frequency per risk allele. Among genetic variants previously associated with AF, there was a significant enrichment in concordance of effect for PAC frequency (n = 73/106, p = 5.1 × 10-5). However, several AF risk loci, including PITX2, were not associated with PAC frequency. These findings suggest the existence of both shared and distinct genetic mechanisms for PAC frequency and AF.

6.
BMJ Open ; 12(6): e058274, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35728900

RESUMO

OBJECTIVES: We investigated machinelearningbased identification of presymptomatic COVID-19 and detection of infection-related changes in physiology using a wearable device. DESIGN: Interim analysis of a prospective cohort study. SETTING, PARTICIPANTS AND INTERVENTIONS: Participants from a national cohort study in Liechtenstein were included. Nightly they wore the Ava-bracelet that measured respiratory rate (RR), heart rate (HR), HR variability (HRV), wrist-skin temperature (WST) and skin perfusion. SARS-CoV-2 infection was diagnosed by molecular and/or serological assays. RESULTS: A total of 1.5 million hours of physiological data were recorded from 1163 participants (mean age 44±5.5 years). COVID-19 was confirmed in 127 participants of which, 66 (52%) had worn their device from baseline to symptom onset (SO) and were included in this analysis. Multi-level modelling revealed significant changes in five (RR, HR, HRV, HRV ratio and WST) device-measured physiological parameters during the incubation, presymptomatic, symptomatic and recovery periods of COVID-19 compared with baseline. The training set represented an 8-day long instance extracted from day 10 to day 2 before SO. The training set consisted of 40 days measurements from 66 participants. Based on a random split, the test set included 30% of participants and 70% were selected for the training set. The developed long short-term memory (LSTM) based recurrent neural network (RNN) algorithm had a recall (sensitivity) of 0.73 in the training set and 0.68 in the testing set when detecting COVID-19 up to 2 days prior to SO. CONCLUSION: Wearable sensor technology can enable COVID-19 detection during the presymptomatic period. Our proposed RNN algorithm identified 68% of COVID-19 positive participants 2 days prior to SO and will be further trained and validated in a randomised, single-blinded, two-period, two-sequence crossover trial. Trial registration number ISRCTN51255782; Pre-results.


Assuntos
COVID-19 , Adulto , COVID-19/diagnóstico , Estudos de Coortes , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , SARS-CoV-2
7.
Clin Chim Acta ; 531: 100-111, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35341762

RESUMO

BACKGROUND AND AIMS: The potential of disease-modifying therapies for Alzheimer's disease has greatly stimulated interest in the development of minimally invasive testing for early identification of at-risk individuals. Accordingly, identification of blood-based biomarkers is paramount. The recent discovery of plasma phosphorylated at threonine217 (p-tau217) may provide a turning point in Alzheimer's disease detection. This systematic review aims to evaluate the available evidence on the use of plasma p-tau217 as a marker to predict Alzheimer's disease and to monitor disease progression. MATERIAL AND METHODS: This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Study quality was assessed using the QUADAS-2 tool. In total, 676 publications were identified, of which 16 were in accordance with the pre-defined eligibility criteria. RESULTS: Current evidence shows that plasma p-tau217 is a sensitive maker of the clinical manifestation and progression of Alzheimer's disease and of pathological changes associated with this condition, including amyloid accumulation, tau burden, brain atrophy and physical degradation. Moreover, given that plasma p-tau217 does not predict such changes in patients with other neurodegenerative disorders, plasma p-tau217 is also specific to Alzheimer's disease. CONCLUSION: More large, diverse community studies are needed to harmonize plasma p-tau217 measurements and to determine widely applicable diagnostic cut-off values.


Assuntos
Doença de Alzheimer , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides/metabolismo , Biomarcadores , Progressão da Doença , Humanos , Proteínas tau/metabolismo
8.
Front Cardiovasc Med ; 8: 622619, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33987209

RESUMO

Background: Omega-3 fatty acids are associated with a lower risk of cardiovascular disease (CVD) and with beneficial effects on CV risk factors. The albumin-creatinine ratio (ACR) is a risk factor for CVD, all-cause mortality and accelerated glomerular filtration rate (GFR) decline in the general population. We aimed to investigate the association between n-3 PUFAS and ACR in heathy individuals with preserved GFR. Design and Methods: The present cross-sectional analysis is part of the GAPP study, a population-based cohort of healthy adults aged 25-41 years. Individuals with known CVD, diabetes, or a BMI >35 kg/m2 were excluded. eGFR was calculated according to the combined Creatinine/Cystatin C CKD-EPI formula. ACR was obtained from a fasting morning urine sample. The Omega-3 Index (relative amount of EPA and DHA of total fatty acids in %) was obtained from whole blood aliquots. Results: Overall, 2001 participants (median age 37 years IQR 31; 40, 53% female) were included in this analysis. Median Omega-3 Index was 4.59 (IQR 4.06; 5.25) and median eGFR 111 ml/min/1.73 m2 (IQR 103; 118). Median ACR was 0.14 mg/mmol (IQR 0; 0.43). We found a significant inverse association of the Omega-3 Index with ACR (ratio 0.84, 95%CI 0.73-0.96; p = 0.011) which remained after comprehensive adjustment (ratio 0.86, 95%CI 0.74-1.00; p = 0.048). No association of the Omega-3 Index with eGFR was found. The adjusted difference in eGFR per 1-unit increase in Omega3-Index was -0.21 (95%CI -0.76; 0.35; p = 0.47). Conclusions: A higher Omega-3 Index was significantly associated with lower ACR in this young and healthy population with preserved eGFR. Omega-3 fatty acids may exhibit cardio- and nephroprotective effects in healthy individuals through modulation of ACR.

9.
Dis Markers ; 2021: 8810196, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33532006

RESUMO

Several tests based on chemiluminescence immunoassay techniques have become available to test for SARS-CoV-2 antibodies. There is currently insufficient data on serology assay performance beyond 35 days after symptoms onset. We aimed to evaluate SARS-CoV-2 antibody tests on three widely used platforms. A chemiluminescent microparticle immunoassay (CMIA; Abbott Diagnostics, USA), a luminescence immunoassay (LIA; Diasorin, Italy), and an electrochemiluminescence immunoassay (ECLIA; Roche Diagnostics, Switzerland) were investigated. In a multigroup study, sensitivity was assessed in a group of participants with confirmed SARS-CoV-2 (n = 145), whereas specificity was determined in two groups of participants without evidence of COVID-19 (i.e., healthy blood donors, n = 191, and healthcare workers, n = 1002). Receiver operating characteristic (ROC) curves, multilevel likelihood ratios (LR), and positive (PPV) and negative (NPV) predictive values were characterized. Finally, analytical specificity was characterized in samples with evidence of the Epstein-Barr virus (EBV) (n = 9), cytomegalovirus (CMV) (n = 7), and endemic common-cold coronavirus infections (n = 12) taken prior to the current SARS-CoV-2 pandemic. The diagnostic accuracy was comparable in all three assays (AUC 0.98). Using the manufacturers' cut-offs, the sensitivities were 90%, 95% confidence interval [84,94] (LIA), 93% [88,96] (CMIA), and 96% [91,98] (ECLIA). The specificities were 99.5% [98.9,99.8] (CMIA), 99.7% [99.3,99.9] (LIA), and 99.9% [99.5,99.98] (ECLIA). The LR at half of the manufacturers' cut-offs were 60 (CMIA), 82 (LIA), and 575 (ECLIA) for positive and 0.043 (CMIA) and 0.035 (LIA, ECLIA) for negative results. ECLIA had higher PPV at low pretest probabilities than CMIA and LIA. No interference with EBV or CMV infection was observed, whereas endemic coronavirus in some cases provided signals in LIA and/or CMIA. Although the diagnostic accuracy of the three investigated assays is comparable, their performance in low-prevalence settings is different. Introducing gray zones at half of the manufacturers' cut-offs is suggested, especially for orthogonal testing approaches that use a second assay for confirmation.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Medições Luminescentes/métodos , SARS-CoV-2/imunologia , Adulto , Teste para COVID-19 , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
10.
J Clin Med ; 9(12)2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33317059

RESUMO

Pan-immunoglobulin assays can simultaneously detect IgG, IgM and IgA directed against the receptor binding domain (RBD) of the S1 subunit of the spike protein (S) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 S1-RBD Ig). In this work, we aim to evaluate a quantitative SARS-CoV-2 S1-RBD Ig electrochemiluminescence immunoassay (ECLIA) regarding analytical, diagnostic, operational and clinical characteristics. Our work takes the form of a population-based study in the principality of Liechtenstein, including 125 cases with clinically well-described and laboratory confirmed SARS-CoV-2 infection and 1159 individuals without evidence of coronavirus disease 2019 (COVID-19). SARS-CoV-2 cases were tested for antibodies in sera taken with a median of 48 days (interquartile range, IQR, 43-52) and 139 days (IQR, 129-144) after symptom onset. Sera were also tested with other assays targeting antibodies against non-RBD-S1 and -S1/S2 epitopes. Sensitivity was 97.6% (95% confidence interval, CI, 93.2-99.1), whereas specificity was 99.8% (95% CI, 99.4-99.9). Antibody levels linearly decreased from hospitalized patients to symptomatic outpatients and SARS-CoV-2 infection without symptoms (p < 0.001). Among cases with SARS-CoV-2 infection, smokers had lower antibody levels than non-smokers (p = 0.04), and patients with fever had higher antibody levels than patients without fever (p = 0.001). Pan-SARS-CoV-2 S1-RBD Ig in SARS-CoV-2 infection cases significantly increased from first to second follow-up (p < 0.001). A substantial proportion of individuals without evidence of past SARS-CoV-2 infection displayed non-S1-RBD antibody reactivities (248/1159, i.e., 21.4%, 95% CI, 19.1-23.4). In conclusion, a quantitative SARS-CoV-2 S1-RBD Ig assay offers favorable and sustained assay characteristics allowing the determination of quantitative associations between clinical characteristics (e.g., disease severity, smoking or fever) and antibody levels. The assay could also help to identify individuals with antibodies of non-S1-RBD specificity with potential clinical cross-reactivity to SARS-CoV-2.

11.
Biomed Res Int ; 2020: 9878453, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33224987

RESUMO

Knowledge of the sensitivities of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests beyond 35 days after the clinical onset of COVID-19 is insufficient. We aimed to describe positivity rate of SARS-CoV-2 assays employing three different measurement principles over a prolonged period. Two hundred sixty-eight samples from 180 symptomatic patients with COVID-19 and a reverse transcription polymerase chain reaction (RT-PCR) test followed by serological investigation of SARS-CoV-2 antibodies were included. We conducted three chemiluminescence (including electrochemiluminescence assay (ECLIA)), four enzyme-linked immunosorbent assay (ELISA), and one lateral flow immunoassay (LFIA) test formats. Positivity rates, as well as positive (PPVs) and negative predictive values (NPVs), were calculated for each week after the first clinical presentation for COVID-19. Furthermore, combinations of tests were assessed within an orthogonal testing approach employing two independent assays and predictive values were calculated. Heat maps were constructed to graphically illustrate operational test characteristics. During a follow-up period of more than 9 weeks, chemiluminescence assays and one ELISA IgG test showed stable positivity rates after the third week. With the exception of ECLIA, the PPVs of the other chemiluminescence assays were ≥95% for COVID-19 only after the second week. ELISA and LFIA had somewhat lower PPVs. IgM exhibited insufficient predictive characteristics. An orthogonal testing approach provided PPVs ≥ 95% for patients with a moderate pretest probability (e.g., symptomatic patients), even for tests with a low single test performance. After the second week, NPVs of all but IgM assays were ≥95% for patients with low to moderate pretest probability. The confirmation of negative results using an orthogonal algorithm with another assay provided lower NPVs than the single assays. When interpreting results from SARS-CoV-2 tests, the pretest probability, time of blood draw, and assay characteristics must be carefully considered. An orthogonal testing approach increases the accuracy of positive, but not negative, predictions.


Assuntos
Anticorpos Antivirais/imunologia , Betacoronavirus/imunologia , Infecções por Coronavirus/imunologia , Pneumonia Viral/imunologia , Anticorpos Antivirais/sangue , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/sangue , Infecções por Coronavirus/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/sangue , Pneumonia Viral/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2 , Sensibilidade e Especificidade , Testes Sorológicos/métodos
12.
Clin Chem Lab Med ; 58(12): 2131-2140, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32866113

RESUMO

Objectives The sensitivity of molecular and serological methods for COVID-19 testing in an epidemiological setting is not well described. The aim of the study was to determine the frequency of negative RT-PCR results at first clinical presentation as well as negative serological results after a follow-up of at least 3 weeks. Methods Among all patients seen for suspected COVID-19 in Liechtenstein (n=1921), we included initially RT-PCR positive index patients (n=85) as well as initially RT-PCR negative (n=66) for follow-up with SARS-CoV-2 antibody testing. Antibodies were detected with seven different commercially available immunoassays. Frequencies of negative RT-PCR and serology results in individuals with COVID-19 were determined and compared to those observed in a validation cohort of Swiss patients (n=211). Results Among COVID-19 patients in Liechtenstein, false-negative RT-PCR at initial presentation was seen in 18% (12/66), whereas negative serology in COVID-19 patients was 4% (3/85). The validation cohort showed similar frequencies: 2/66 (3%) for negative serology, and 16/155 (10%) for false negative RT-PCR. COVID-19 patients with negative follow-up serology tended to have a longer disease duration (p=0.05) and more clinical symptoms than other patients with COVID-19 (p<0.05). The antibody titer from quantitative immunoassays was positively associated with the number of disease symptoms and disease duration (p<0.001). Conclusions RT-PCR at initial presentation in patients with suspected COVID-19 can miss infected patients. Antibody titers of SARS-CoV-2 assays are linked to the number of disease symptoms and the duration of disease. One in 25 patients with RT-PCR-positive COVID-19 does not develop antibodies detectable with frequently employed and commercially available immunoassays.


Assuntos
Betacoronavirus/genética , Betacoronavirus/imunologia , Reação em Cadeia da Polimerase em Tempo Real , Testes Sorológicos , Adulto , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2 , Fatores de Tempo , Adulto Jovem
13.
Diagnostics (Basel) ; 10(8)2020 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-32823852

RESUMO

While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology. CLIAs and ELISAs can be automated to a high degree but commonly require larger serum or plasma volumes for sample processing. We addressed the suitability of EDTA-anticoagulated whole blood as an alternative sample material for antibody testing against SARS-CoV-2 by electro-CLIA (ECLIA; Roche, Rotkreuz, Switzerland) and ELISA (IgG and IgA; Euroimmun, Germany). Simultaneously drawn venous serum and EDTA-anticoagulated whole blood samples from 223 individuals were included. Correction of the whole blood results for hematocrit led to a good agreement with the serum results for weakly to moderately positive antibody signals. In receiver-operating characteristic curve analysis, all three assays displayed comparable diagnostic accuracy (area under the curve (AUC)) using corrected whole blood and serum (AUCs: 0.97 for ECLIA and IgG ELISA; 0.84 for IgA ELISA). In conclusion, our results suggest that the investigated assays can reliably detect antibodies against SARS-CoV-2 in hemolyzed whole blood anticoagulated with EDTA. Correction of these results for hematocrit is suggested. This study demonstrates that the automated processing of whole blood for identification of SARS-CoV-2 antibodies with common ECLIA and ELISA methods is accurate and feasible.

14.
Gesundheitswesen ; 81(11): 926-932, 2019 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-29458224

RESUMO

The aim of this paper is to describe the development of an innovative bachelor's degree program for physiotherapy directly affiliated with the medical department, which is a unique approach to making physiotherapy an academic course in Germany. The previous system for qualifying as a physiotherapist was amended by the adaption of qualification objectives resulting in a model that links scientific and vocational knowledge from the beginning of the study. Several lectures support interprofessionality. The vocational training is fully integrated into the curriculum. The exemplary concept is monitored by an extensive quality management program. The approach meets general recommendations of experts and can serve as a model for other universities.


Assuntos
Currículo , Fisioterapeutas , Universidades , Alemanha , Humanos , Fisioterapeutas/educação , Modalidades de Fisioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA