Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Am J Cardiol ; 177: 84-89, 2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35732551

RESUMO

A subset of patients with severe aortic stenosis (AS) who are who underwent transcatheter aortic valve implantation (TAVI) also has mitral regurgitation (MR). Clinical outcomes in these patients with combined MR and AS have varied. The purpose of this study was to assess clinical outcomes and echocardiographic outcomes after TAVI in patients with preprocedural MR. A retrospective chart review from March 2018 to June 2020 identified all TAVI patients. Patients were assigned an MR class of mild, moderate, or severe based upon pre-TAVI transthoracic echocardiogram (TTE). Patients were excluded if they were discharged from the hospital and did not have a 6-month follow-up after TAVI. Clinical outcomes at 6 months included all-cause mortality, major adverse cardiovascular events, clinically significant bleeding, changes in ejection fraction (EF) category, and changes in MR severity. Of 118 included patients (age 76 ± 10 years, 79% male, 46% White), 33% had MR, with 26% being mild and 7% moderate MR. Before TAVI, AS + MR patients were more likely to have a reduced EF (<50%) by category compared with those with AS only (33.3% vs 8.8%, p = 0.01) but were more likely to show an increase in EF by category after TAVI (19.4% vs 5.5%, p = 0.039). No significant differences were observed between the 2 groups in terms of all-cause mortality (12.8 vs 5.1%, p = 0.14), major adverse cardiovascular events (17.9 vs 8.9%, p = 0.15), or clinically significant bleeding (10.3 vs 6.3%, p = 0.45). Patients with AS and co-existing MR experienced similar clinical outcomes at 6 months to those with AS only after TAVI. They were more likely to show increases in EF category 6 months after valve implantation. Our results support the conclusion that in addition to treating the aortic valve, TAVI also potentially benefits left ventricular function in the setting of mild or moderate MR.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Am J Cardiol ; 156: 108-113, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34344508

RESUMO

Aortic valve calcium (AVC) is a strong predictor of aortic stenosis (AS) severity and is typically calculated by multidetector computed tomography (MDCT). We propose a novel method using pixel density quantification software to objectively quantify AVC by two-dimensional (2D) transthoracic echocardiography (TTE) and distinguish severe from non-severe AS. A total of 90 patients (mean age 76 ± 10 years, 75% male, mean AV gradient 32 ± 11 mmHg, peak AV velocity 3.6 ± 0.6 m/s, AV area (AVA) 1.0 ± 0.3 cm2, dimensionless index (DI) 0.27 ± 0.08) with suspected severe aortic stenosis undergoing 2D echocardiography were retrospectively evaluated. Parasternal short axis aortic valve views were used to calculate a gain-independent ratio between the average pixel density of the entire aortic valve in short axis at end diastole and the average pixel density of the aortic annulus in short axis (2D-AVC ratio). The 2D-AVC ratio was compared to echocardiographic hemodynamic parameters associated with AS, MDCT AVC quantification, and expert reader interpretation of AS severity based on echocardiographic AVC interpretation. The 2D-AVC ratio exhibited strong correlations with mean AV gradient (r = 0.72, p < 0.001), peak AV velocity (r = 0.74, p < 0.001), AVC quantified by MDCT (r = 0.71, p <0.001) and excellent accuracy in distinguishing severe from non-severe AS (area under the curve = 0.93). Conversely, expert reader interpretation of AS severity based on echocardiographic AVC was not significantly related to AV mean gradient (t = 0.23, p = 0.64), AVA (t = 2.94, p = 0.11), peak velocity (t = 0.59, p = 0.46), or DI (t = 0.02, p = 0.89). In conclusion, these data suggest that the 2D-AVC ratio may be a complementary method for AS severity adjudication that is readily quantifiable at time of TTE.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico , Cálcio/metabolismo , Ecocardiografia/métodos , Idoso , Valva Aórtica/metabolismo , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Calcinose/metabolismo , Calcinose/fisiopatologia , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença
3.
Am J Cardiovasc Dis ; 11(2): 203-211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34084655

RESUMO

OBJECTIVE: In the United States, racial minorities are underrepresented among patients receiving transcatheter aortic valve replacement (TAVR) and data regarding their outcomes is limited. Global longitudinal strain (GLS) is a measure left ventricular function and has independently predicted outcomes after TAVR. The aim of this study is to assess changes in GLS after TAVR according to race and factors predicting these changes. METHODS: Electronic medical records of patients undergoing TAVR at the University of Illinois, Chicago and Jesse Brown Veteran's Administration Medical Center (Chicago, Illinois) from January 2017-February 2020 were reviewed retrospectively. The most recent transthoracic echocardiogram (TTE) prior to TAVR and the TTE 1-month post-procedure were used to determine GLS. Patients were included if both a pre- and post-procedure study were present and TTE images were of sufficient quality to process strain imaging. RESULTS: A total of 103 patients (average age 76 ± 12 years, 80% male, 42% white) were included. At 1-month post-TAVR, GLS improved for all races: white (-2.7 ± 3.5%, P<0.001), African-American (-2.8 ± 3.3%, P<0.001), and Hispanic (-2.0 ± 2.1%, P<0.001). There were no differences in the degree of improvement among races (P=0.62). Baseline GLS was negatively correlated with changes in GLS overall (r=-0.44, P<0.001). Baseline aortic valve area (cm2) was positively correlated with changes in GLS (r=0.2, P=0.036). CONCLUSIONS: This study demonstrated that GLS improved after TAVR independent of race with similar degrees of change across races. Baseline GLS and aortic valve area predicted strain improvement after TAVR, which suggests that those with more impaired LV function may benefit most from the procedure.

4.
Interv Cardiol Clin ; 8(4): 373-382, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31445721

RESUMO

Patient-prosthesis mismatch (PPM) is common after surgical valve aortic replacement. A significant percentage of patients with a small annulus have moderate to severe PPM. The outcomes for patients with larger effective orifice areas and lower gradients are better than for patients with PPM. With the advent of valve-in-valve TAVR, a degenerated surgical bioprosthesis can be treated with a percutaneous approach. However, the issue of PPM cannot be overcome by simply implanting a new valve. The technique of bioprosthetic valve fracture was therefore developed. This allows for implantation of a fully expanded transcatheter valve and results in a large effective orifice.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Seleção de Pacientes , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Saúde Global , Humanos , Incidência , Falha de Prótese , Fatores de Risco
5.
Circ Cardiovasc Interv ; 11(4): e005635, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29632238

RESUMO

BACKGROUND: The influence of cangrelor on the incidence and outcomes of post-percutaneous coronary intervention (PCI) thrombocytopenia is not defined. We aimed to explore the incidence, predictors, and clinical impact of thrombocytopenia after PCI in cangrelor-treated patients. METHODS AND RESULTS: This was a pooled, patient-level analysis of the CHAMPION trials (Cangrelor Versus Standard Therapy to Achieve Optimal Management of Platelet Inhibition), which compared cangrelor with clopidogrel for prevention of thrombotic complications during and after PCI. Acquired thrombocytopenia was defined as either a drop in platelet count to <100 000 after PCI or a drop of >50% between baseline and a follow-up. The main efficacy outcome was major adverse cardiac events. The primary safety outcome was noncoronary artery bypass grafting-related Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries-defined severe bleeding at 48 hours. Patients (23 783) were enrolled, and 3009 (12.7%) received a GPI (glycoprotein IIb/IIIa inhibitor). Acquired thrombocytopenia occurred in 200 patients (0.8%). The adjusted rate of major adverse cardiovascular events at 48 hours was significantly higher in patients who developed thrombocytopenia compared with those who did not (odds ratio, 3.00; 95% confidence interval, 1.89-4.69; P<0.001), as was major bleeding (odds ratio, 14.71; 95% confidence interval, 5.96-36.30; P<0.001). GPI use was the strongest independent predictor of acquired thrombocytopenia (odds ratio, 2.93; 95% confidence interval, 2.15-3.97; P<0.0001). There was no difference in the rate of acquired thrombocytopenia in patients randomized to cangrelor or clopidogrel. CONCLUSIONS: Acquired thrombocytopenia after PCI is strongly associated with substantial early morbidity and mortality, as well as major bleeding. GPI use is a significant predictor of thrombocytopenia. Cangrelor is not associated with acquired thrombocytopenia, and its clinical efficacy and safety is consistent irrespective of thrombocytopenia occurrence. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifiers: NCT00305162, NCT00385138, and NCT01156571.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Clopidogrel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Trombocitopenia/epidemiologia , Monofosfato de Adenosina/administração & dosagem , Monofosfato de Adenosina/efeitos adversos , Idoso , Clopidogrel/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Contagem de Plaquetas , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Trombocitopenia/sangue , Trombocitopenia/induzido quimicamente , Trombocitopenia/mortalidade , Fatores de Tempo , Resultado do Tratamento
6.
Radiology ; 286(1): 93-102, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29059038

RESUMO

Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (PFPA and PMSM) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (PMICRO), as follows: PFPA_COMBINED = 1.02 PMICRO_COMBINED + 0.11 (r = 0.96) and PMSM_COMBINED = 0.28 PMICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Área Sob a Curva , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Frequência Cardíaca/fisiologia , Reprodutibilidade dos Testes , Suínos
7.
IEEE Trans Biomed Eng ; 64(1): 134-144, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27046887

RESUMO

OBJECTIVE: This study's objective is to develop and validate a fast automated 3-D segmentation method for cardiac magnetic resonance imaging (MRI). The segmentation algorithm automatically reconstructs cardiac MRI DICOM data into a 3-D model (i.e., direct volumetric segmentation), without relying on prior statistical knowledge. METHODS: A novel 3-D active contour method was employed to detect the left ventricular cavity in 33 subjects with heterogeneous heart diseases from the York University database. Papillary muscles were identified and added to the chamber using a convex hull of the left ventricle and interpolation. The myocardium was then segmented using a similar 3-D segmentation method according to anatomic information. A multistage approach was taken to determine the method's efficacy. RESULTS: Our method demonstrated a significant improvement in segmentation performance when compared to manual segmentation and other automated methods. CONCLUSION AND SIGNIFICANCE: A true 3-D reconstruction technique without the need for training datasets or any user-driven segmentation has been developed. In this method, a novel combination of internal and external energy terms for active contour was utilized that exploits histogram matching for improving the segmentation performance. This method takes advantage of full volumetric imaging, does not rely on prior statistical knowledge, and employs a convex-hull interpolation to include the papillary muscles.


Assuntos
Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Circ Cardiovasc Imaging ; 9(12)2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27956409

RESUMO

BACKGROUND: Computed tomographic (CT) angiography is an important tool for the evaluation of coronary artery disease but often correlates poorly with myocardial ischemia. Current dynamic CT perfusion techniques can assess ischemia but have limited accuracy and deliver high radiation dose. Therefore, an accurate, low-dose, dynamic CT perfusion technique is needed. METHODS AND RESULTS: A total of 20 contrast-enhanced CT volume scans were acquired in 5 swine (40±10 kg) to generate CT angiography and perfusion images. Varying degrees of stenosis were induced using a balloon catheter in the proximal left anterior descending coronary artery, and a pressure wire was used for reference fractional flow reserve (FFR) measurement. Perfusion measurements were made with only 2 volume scans using a new first-pass analysis (FPA) technique and with 20 volume scans using an existing maximum slope model (MSM) technique. Perfusion (P) and FFR measurements were related by PFPA=1.01 FFR-0.03 (R2=0.85) and PMSM=1.03 FFR-0.03 (R2=0.80) for FPA and MSM techniques, respectively. Additionally, the effective radiation doses were calculated to be 2.64 and 26.4 mSv for FPA and MSM techniques, respectively. CONCLUSIONS: A new FPA-based dynamic CT perfusion technique was validated in a swine animal model. The results indicate that the FPA technique can potentially be used for improved anatomical and functional assessment of coronary artery disease at a relatively low radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagem de Perfusão do Miocárdio/métodos , Animais , Área Sob a Curva , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Modelos Animais de Doenças , Masculino , Valor Preditivo dos Testes , Curva ROC , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Sus scrofa , Fatores de Tempo
9.
10.
Int J Cardiol ; 210: 164-72, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26950171

RESUMO

BACKGROUND: We assessed in-hospital mortality and utilization of invasive cardiac procedures following Acute Coronary Syndrome (ACS) admissions on the weekend versus weekdays over the past decade in the United States. METHODS: We used data from the Nationwide Inpatient Survey (2001-2011) to examine differences in all-cause in-hospital mortality between patients with a principal diagnosis of ACS admitted on a weekend versus a weekday. Adjusted and hierarchical logistic regression model analysis was then used to identify if weekend admission was associated with a decreased utilization of procedural interventions and increased subsequent complications as well. RESULTS: 13,988,772 ACS admissions were identified. Adjusted mortality was higher for weekend admissions for Non-ST-Elevation Acute Coronary Syndromes [OR: 1.15, 95% CI, 1.14-1.16] and only somewhat higher for ST-Elevation Myocardial Infarction [OR: 1.03; 95% CI, 1.01-1.04]. Additionally, patients were significantly less likely to receive coronary revascularization intervention/therapy on their first day of admission [OR: 0.97, 95% CI: 0.96-0.98 and OR: 0.75, 95% CI: 0.75-0.75 for STEMI and NSTE-ACS respectively]. For ACS patients admitted during the weekend who underwent procedural interventions, in-hospital mortality and complications were higher as compared to patients undergoing the same procedures on weekdays. CONCLUSION: For ACS patients, weekend admission is associated with higher mortality and lower utilization of invasive cardiac procedures, and those who did undergo these interventions had higher rates of mortality and complications than their weekday counterparts. This data leads to the possible conclusion that access to diagnostic/interventional procedures may be contingent upon the day of admission, which may impact mortality.


Assuntos
Síndrome Coronariana Aguda/mortalidade , Mortalidade Hospitalar/tendências , Admissão do Paciente/tendências , Síndrome Coronariana Aguda/terapia , Idoso , Estudos de Coortes , Feminino , Hospitalização/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Estados Unidos/epidemiologia
11.
Heart Fail Clin ; 12(1): 83-95, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26567976

RESUMO

Coronary angiography is the gold standard for the diagnosis of coronary artery disease and guides revascularization strategies. The emergence of new diagnostic modalities has provided clinicians with adjunctive physiologic and image-based data to help formulate treatment strategies. Fractional flow reserve can predict whether percutaneous intervention will benefit a patient. Intravascular ultrasonography and optical coherence tomography are intracoronary imaging modalities that facilitate the anatomic visualization of the vessel lumen and characterize plaques. Near-infrared spectroscopy can characterize plaque composition and potentially provide valuable prognostic information. This article reviews the indications, basic technology, and supporting clinical studies for these modalities.

12.
Ann Biomed Eng ; 43(10): 2314-33, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26224522

RESUMO

In this final portion of an extensive review of heart valve engineering, we focus on the computational methods and experimental studies related to heart valves. The discussion begins with a thorough review of computational modeling and the governing equations of fluid and structural interaction. We then move onto multiscale and disease specific modeling. Finally, advanced methods related to in vitro testing of the heart valves are reviewed. This section of the review series is intended to illustrate application of computational methods and experimental studies and their interrelation for studying heart valves.


Assuntos
Simulação por Computador , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Feminino , Humanos , Masculino
13.
EuroIntervention ; 11(5): 591-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25772904

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is an emerging field with technological challenges. One major challenge is to minimise delivery catheter size to reduce vascular trauma, while maintaining features such as repositionability and retrievability. This study was designed as proof of concept of FOLDAVALVE, using a short-term ovine model. METHODS AND RESULTS: FOLDAVALVE is a fully repositionable and retrievable transcatheter aortic valve with a 14 Fr delivery system whose leaflets are excluded from the stent during crimping. A short-term ovine model (n=3) was used for transfemoral implantations at the Institut Mutualiste Montsouris in Paris. There was a smooth transition of the valve over the aortic arch followed by seamless delivery into the native ovine aortic position. Implantation was followed by repositioning, resheathing and retrieval, then implantation of a fresh prosthesis in the same animal. Transoesophageal echocardiography and fluoroscopy were used to monitor the delivery and implantation processes and to demonstrate valve functionality. Animal sacrifice and direct visualisation after explant confirmed excellent final position. CONCLUSIONS: FOLDAVALVE was successfully implanted in the aortic position of an ovine model. FOLDAVALVE is a promising technology which has been shown to be feasible in this preclinical TAVI study.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Animais , Cateteres Cardíacos , Modelos Animais , Ovinos , Substituição da Valva Aórtica Transcateter/métodos
14.
Ann Biomed Eng ; 43(4): 858-70, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25287646

RESUMO

In this portion of an extensive review of heart valve engineering, we focus on the current and emerging technologies and techniques to repair or replace the mitral valve. We begin with a discussion of the currently available mechanical and bioprosthetic mitral valves followed by the rationale and limitations of current surgical mitral annuloplasty methods; a discussion of the technique of neo-chordae fabrication and implantation; a review the procedures and clinical results for catheter-based mitral leaflet repair; a highlight of the motivation for and limitations of catheter-based annular reduction therapies; and introduce the early generation devices for catheter-based mitral valve replacement.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Engenharia Tecidual/métodos , Engenharia Tecidual/tendências , Animais , Humanos
15.
Ann Biomed Eng ; 43(4): 833-43, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25488074

RESUMO

As the first section of a multi-part review series, this section provides an overview of the ongoing research and development aimed at fabricating novel heart valve replacements beyond what is currently available for patients. Here we discuss heart valve replacement options that involve a biological component or process for creation, either in vitro or in vivo (tissue-engineered heart valves), and heart valves that are fabricated from polymeric material that are considered permanent inert materials that may suffice for adults where growth is not required. Polymeric materials provide opportunities for cost-effective heart valves that can be more easily manufactured and can be easily integrated with artificial heart and ventricular assist device technologies. Tissue engineered heart valves show promise as a regenerative patient specific model that could be the future of all valve replacement. Because tissue-engineered heart valves depend on cells for their creation, understanding how cells sense and respond to chemical and physical stimuli in their microenvironment is critical and therefore, is also reviewed.


Assuntos
Bioprótese , Microambiente Celular , Próteses Valvulares Cardíacas , Coração Artificial , Engenharia Tecidual , Animais , Humanos , Engenharia Tecidual/métodos , Engenharia Tecidual/tendências
16.
Ann Biomed Eng ; 43(4): 844-57, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25449148

RESUMO

The engineering of technologies for heart valve replacement (i.e., heart valve engineering) is an exciting and evolving field. Since the first valve replacement, technology has progressed by leaps and bounds. Innovations emerge frequently and supply patients and physicians with new, increasingly efficacious and less invasive treatment options. As much as any other field in medicine the treatment of heart valve disease has experienced a renaissance in the last 10 years. Here we review the currently available technologies and future options in the surgical and transcatheter treatment of aortic valve disease. Different valves from major manufacturers are described in details with their applications.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Engenharia Tecidual/métodos , Engenharia Tecidual/tendências , Animais , Humanos
17.
Cardiol Clin ; 32(3): 405-17, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25091966

RESUMO

Coronary angiography is the gold standard for the diagnosis of coronary artery disease and guides revascularization strategies. The emergence of new diagnostic modalities has provided clinicians with adjunctive physiologic and image-based data to help formulate treatment strategies. Fractional flow reserve can predict whether percutaneous intervention will benefit a patient. Intravascular ultrasonography and optical coherence tomography are intracoronary imaging modalities that facilitate the anatomic visualization of the vessel lumen and characterize plaques. Near-infrared spectroscopy can characterize plaque composition and potentially provide valuable prognostic information. This article reviews the indications, basic technology, and supporting clinical studies for these modalities.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Doença da Artéria Coronariana/fisiopatologia , Humanos , Valor Preditivo dos Testes
18.
ASAIO J ; 60(5): 545-552, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25010918

RESUMO

Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantify the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using digital particle image velocimetry and an advanced heart-flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible.


Assuntos
Aorta/cirurgia , Hemodinâmica/fisiologia , Hidrodinâmica , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Humanos , Técnicas In Vitro
19.
Am J Cardiol ; 114(5): 686-91, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25037677

RESUMO

Epicardial adipose tissue (EAT) has been shown to have important effects on the development of coronary artery disease (CAD) through local paracrine influences on the vascular bed. We compared a cohort of asymptomatic patients with type II diabetes mellitus (DM) without known CAD to an age- and gender-matched group of asymptomatic patients without DM from the CTRAD (Cardiac CT's Role in Asymptomatic Patients with DM-II) study in which patients underwent a cardiac computed tomography angiogram, for early detection of CAD. Mean EAT volumes of 118.6 ± 43.0 and 70.0 ± 44.0 cm(3) were found in the DM and non-DM groups, respectively. When stratified by the presence and severity of CAD, it was found that in the DM (p = 0.003) and non-DM groups (p <0.001), there was a statistically significant increase in EAT volume as the patients were found to have increasingly severe CAD. After adjusting for age, race, gender, DM, hypertension, insulin use, body mass index, and coronary artery calcium (CAC) score, the presence of >120 cm(3) of EAT was found to be highly correlated with the presence of significant CAD (adjusted odds ratio 4.47, 95% confidence interval 1.35 to 14.82). We found that not only is EAT volume an independent predictor of CAD but that an increasing volume of EAT predicted increasing severity of CAD even after adjustment for CAC score.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Adiposidade/fisiologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus Tipo 2 , Tomografia Computadorizada Multidetectores/métodos , Pericárdio/diagnóstico por imagem , Adulto , Doença da Artéria Coronariana/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
20.
J Vasc Surg ; 60(2): 318-24, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24709439

RESUMO

OBJECTIVE: Ruptured aortic aneurysm is a condition with a high rate of mortality that requires prompt surgical intervention. It has been noted that in some conditions requiring such prompt intervention, in-hospital mortality is increased in patients admitted on the weekends compared with patients admitted on weekdays. We sought to determine if this was indeed the case for both ruptured thoracic aortic aneurysms (TAA) and abdominal aortic aneurysms (AAA) and to elucidate the possible reasons. METHODS: Using the Nationwide Inpatient Sample, a publicly available database of inpatient care, we analyzed the incidence of mortality among 7200 patients admitted on the weekends compared with weekdays for ruptured aortic aneurysm. Among these patients, 19% had a TAA and 81% had an AAA, and each group was analyzed for differences in mortality during the hospitalization. We adjusted for demographics, comorbid conditions, hospital characteristics, rates of surgical intervention, timing of surgical intervention, and use of additional therapeutic measures. RESULTS: Patients admitted on the weekend for both ruptured TAA and AAA had a statistically significant increase in mortality compared with those admitted on the weekdays (TAA: odds ratio, 2.55; 95% confidence interval, 1.77-3.68; P = .03; AAA: odds ratio, 1.32; 95% confidence interval, 1.13-1.55; P = .0004). Among those with TAA, a surgical intervention was performed on day of admission in 62.1% of weekday admissions vs 34.9% of weekend admissions (P < .0001). This difference was much smaller among those with an aortic aneurysm; 79.6% had a surgical intervention on day of admission on a weekday vs 77.2% on the weekend (P < .0001). CONCLUSIONS: Weekend admission for ruptured aortic aneurysm is associated with an increased mortality compared with admission on a weekday, and this is likely due to several factors including a delay in prompt surgical intervention.


Assuntos
Plantão Médico , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Acessibilidade aos Serviços de Saúde , Admissão do Paciente , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA