RESUMO
Importance: Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective: To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants: The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions: Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures: The composite coprimary clinical end point comprised death, disabling stroke, or heart failure-related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results: A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference -2.3%; 95% CI -7.2 to 2.5, P = .35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference, -33.4%; 95% CI, -40.4 to -26.4; P < .001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance: Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration: ClinicalTrials.gov Identifier: NCT04722250.
RESUMO
Importance: Guidelines advise heart team assessment for all patients with aortic stenosis, with surgical aortic valve replacement recommended for patients younger than 65 years or with a life expectancy greater than 20 years. If bioprosthetic valves are selected, repeat procedures may be needed given limited durability of tissue valves; however, younger patients with aortic stenosis may have major comorbidities that can limit life expectancy, impacting decision-making. Objective: To characterize patients younger than 65 years who received transcatheter aortic valve replacement (TAVR) and compare their outcomes with patients aged 65 to 80 years. Design, Setting, and Participants: This retrospective registry-based analysis used data on 139â¯695 patients from the Society for Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (TVT) Registry, inclusive of patients 80 years and younger undergoing TAVR from August 2019 to September 2023. Intervention: Balloon-expandable valve (BEV) TAVR with the SAPIEN family of devices. Main Outcomes and Measures: Comorbidities (heart failure, coronary artery disease, dialysis, and others) and outcomes (death, stroke, and hospital readmission) of patients younger than 65 years compared to patients aged 65 to 80 years. Results: In the years surveyed, 13â¯849 registry patients (5.7%) were younger than 65 years, 125â¯846 (52.1%) were aged 65 to 80 years, and 101â¯725 (42.1%) were 80 years and older. Among those younger than 65, the mean (SD) age was 59.7 (4.8) years, and 9068 of 13â¯849 patients (65.5%) were male. Among those aged 65 to 80 years, the mean (SD) age was 74.1 (4.2) years, and 77â¯817 of 125â¯843 patients (61.8%) were male. Those younger than 65 years were more likely to have a bicuspid aortic valve than those aged 65 to 80 years (3472/13â¯755 [25.2%] vs 9552/125â¯001 [7.6%], respectively; P < .001). They were more likely to have congestive heart failure, chronic lung disease, diabetes, immunocompromise, and end stage kidney disease receiving dialysis. Patients younger than 65 years had worse baseline quality of life (mean [SD] Kansas City Cardiomyopathy Questionnaire score, 47.7 [26.3] vs 52.9 [25.8], respectively; P < .001) and mean (SD) gait speed (5-meter walk test, 6.6 [5.8] seconds vs 7.0 [4.9] seconds, respectively; P < .001) than those aged 65 to 80 years. At 1 year, patients younger than 65 years had significantly higher readmission rates (2740 [28.2%] vs 23â¯178 [26.1%]; P < .001) and all-cause mortality (908 [9.9%] vs 6877 [8.2%]; P < .001) than older patients. When propensity matched, younger patients still had higher 1-year readmission rates (2732 [28.2%] vs 2589 [26.8%]; P < .03) with similar mortality to their older counterparts (905 [9.9%] vs 827 [10.1%]; P = .55). Conclusions and Relevance: Among US patients receiving BEV TAVR for severe aortic stenosis in the low-surgical risk era, those younger than 65 years represent a small subset. Patients younger than 65 years had a high burden of comorbidities and incurred higher rates of death and readmission at 1 year compared to their older counterparts. These observations suggest that heart team decision-making regarding TAVR for most patients in this age group is clinically valid.
RESUMO
BACKGROUND: Transfemoral transcatheter aortic valve replacement (TF-TAVR) has proven superior to alternative access. However, some patients evaluated for TF-TAVR are unfit secondary to peripheral arterial disease (PAD). Peripheral intravascular lithotripsy (IVL) can facilitate femoral access. This study aimed to characterize optimal lesions that can be treated with IVL. METHODS: Single-center, retrospective analysis of an institutional database, queried from 1/2018 through 7/2023 for all patients who underwent TAVR. Patients who received IVL-facilitated transfemoral access were analyzed. RESULTS: Of 2862 TAVR cases identified, 92 (3.2 %) underwent lithotripsy. The IVL-facilitated cohort had a mean age of 78 ± 9.2 years and 45 % were female. The right common iliac artery was most treated (47). Most IVL was performed with 7-mm balloons (73.9 %). All cases were successful. 30-day mortality was 1.1 % (1/92). CONCLUSIONS: In our cohort, complications after IVL-facilitated TF-TAVR were more common with small vessel diameter (≤4.7 mm), significant luminal loss (>50 % stenosis), and heavy calcium burden (arc calcification >180°). The findings support the use of IVL to expand the population of patients who can undergo TF-TAVR without the increased risks associated with the various forms of alternative access. SUMMARY FOR ANNOTATED TABLE OF CONTENTS: IVL-facilitated TF-TAVR is safe and feasible. Despite its introduction to TAVR clinical practice in 2018, IVL-facilitated TF-TAVR is not regularly performed and could increase the population of patients eligible for TF-TAVR.
RESUMO
Background: Lack of standardization in posttranscatheter aortic valve replacement (TAVR) conduction disturbance (CD) identification and treatment may affect permanent pacemaker implantation (PPI) rates and clinical outcomes. The safety and efficacy of a standardized TAVR CD algorithm has not been analyzed. This study analyzes the Optimize PRO post-TAVR CD management algorithm with Evolut PRO/PRO+ valves. Methods: Optimize PRO is a prospective, postmarket study implementing 2 strategies to reduce pacemaker rates: TAVR with cusp overlap technique and a post-TAVR CD algorithm. The 2-hour postprocedural electrocardiogram (ECG) stratified patients to early discharge in the absence of new ECG changes or to CD algorithms for (1) ECG changes with preexisting right or left bundle branch block (LBBB), interventricular conduction delay or first-degree atrioventricular block, (2) new LBBB, or (3) high-degree atrioventricular block (HAVB). Results: The interim analysis of the CD cohort consisted of 125/400 TAVR recipients. In the CD cohort, the 30-day new PPI rate was higher (28.1% vs 1.5%; P <.001), and 60 (48%) patients were discharged with a 30-day continuous ECG monitor. At 30 days, 90% of patients discharged with a monitor did not require PPI. Clinical outcomes, including mortality, stroke, bleeding, and reintervention, were similar in patients with and without CDs. No patient experienced sudden cardiac death. Conclusions: Effective management of CDs using a standard algorithm following Evolut TAVR provides similar 30-day safety outcomes to patients without CDs who undergo routine next day discharge. The CD algorithm may provide an effective strategy to recognize arrhythmias early, improve PPI utilization, and facilitate safe monitoring of patients after discharge.
RESUMO
Mitral regurgitation is the most common valvular disease in the developed world, with approximately 24.2 million people being affected worldwide and a higher prevalence in older age groups. Surgical correction of degenerative mitral regurgitation is the standard of care and can restore cardiac function and provide a lasting result, especially when the mitral valve can be repaired. Secondary mitral regurgitation, or functional mitral regurgitation (FMR), describes atrial or ventricular factors leading to poor coaptation of an otherwise non-diseased valve. For FMR, traditional surgery has not produced the same level of benefit. Transcatheter mitral repair and replacement techniques that mimic surgical correction are under investigation. Transcatheter edge-to-edge repair is the only approved catheter-based therapy for FMR in the US. Here, the transcatheter treatment options for FMR are reviewed.
RESUMO
For decades, surgeons have recognized the risk of prosthesis-patient mismatch (PPM) when treating aortic stenosis (AS) with surgical aortic valve replacement (SAVR). The concept of PPM-or placing a valve that is too small for the cardiac output requirements of the patient-has been associated with worse patient outcomes, including increased risk of death. Transcatheter aortic valve replacement (TAVR) has become the standard treatment for most patients with severe symptomatic AS and is associated with improved hemodynamics and lower risks of PPM. Larger surgical valves, stentless, and sutureless technology, and surgical aortic annulus enlargement (AAE) have been employed to avoid severe PPM. However, especially in the small aortic annulus (SAA), TAVR may provide a benefit. Understanding who is at risk for PPM requires preplanning, and cardiac-gated computed tomography (CT) imaging is the standard of care when considering TAVR. It should be standard for all patients with AS. Once SAA is identified, the risk of PPM can be calculated, and an informed decision made on whether to proceed with SAVR or TAVR. In the current TAVR era, younger patients are treated with TAVR driven by patient preference, but with little long-term data to support the practice. Selecting the best valve for the patient is a multifactorial decision often nuanced by anatomical considerations, hemodynamic and durability expectations, and decisions regarding lifetime management that may include placing a second valve. Although PPM may be only one of the factors to consider, the association with elevated mean gradients and worse outcomes certainly makes TAVR a good solution for many patients.
RESUMO
BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.
RESUMO
BACKGROUND: The mortality risk attributable to moderate aortic stenosis (AS) remains incompletely characterized and has historically been underestimated. We aim to evaluate the association between moderate AS and all-cause death, comparing it with no/mild AS (in a general referral population and in patients with heart failure with reduced ejection fraction). METHODS AND RESULTS: A systematic review and pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data of studies published by June 2023 was conducted to evaluate survival outcomes among patients with moderate AS in comparison with individuals with no/mild AS. Ten studies were included, encompassing a total of 409 680 patients (11 527 with moderate AS and 398 153 with no/mild AS). In the overall population, the 15-year overall survival rate was 23.3% (95% CI, 19.1%-28.3%) in patients with moderate AS and 58.9% (95% CI, 58.1%-59.7%) in patients with no/mild aortic stenosis (hazard ratio [HR], 2.55 [95% CI, 2.46-2.64]; P<0.001). In patients with heart failure with reduced ejection fraction, the 10-year overall survival rate was 15.5% (95% CI, 10.0%-24.0%) in patients with moderate AS and 37.3% (95% CI, 36.2%-38.5%) in patients with no/mild AS (HR, 1.83 [95% CI, 1.69-2.0]; P<0.001). In both populations (overall and heart failure with reduced ejection fraction), these differences correspond to significant lifetime loss associated with moderate AS during follow-up (4.4 years, P<0.001; and 1.9 years, P<0.001, respectively). A consistent pattern of elevated mortality rate associated with moderate AS in sensitivity analyses of matched studies was observed. CONCLUSIONS: Moderate AS was associated with higher risk of death and lifetime loss compared with patients with no/mild AS.
Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico/fisiologia , Causas de Morte , Fatores de Tempo , Feminino , Idoso , MasculinoRESUMO
BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.
Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologiaRESUMO
BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.
Assuntos
Estenose da Valva Aórtica , Alta do Paciente , Readmissão do Paciente , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/tendências , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso , Alta do Paciente/tendências , Sistema de Registros , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Fatores de Tempo , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Fatores de Risco , Valva Aórtica/cirurgia , Estudos Retrospectivos , Desenho de Prótese , Medição de RiscoRESUMO
BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , RetratamentoRESUMO
Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.
Assuntos
Ecocardiografia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Masculino , Insuficiência da Valva Tricúspide/cirurgia , Feminino , Estudos Retrospectivos , Idoso , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença , Resultado do Tratamento , Causas de Morte/tendências , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagemRESUMO
BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversosRESUMO
BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.
Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversosAssuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estudos de Viabilidade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Reoperação , Falha de PróteseRESUMO
BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.
Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Remoção de Dispositivo , Catéteres , Valvas Cardíacas , Sistema de RegistrosAssuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Desenho de PróteseRESUMO
Cardiac amyloidosis is caused by the extracellular deposition of amyloid fibrils in the heart, involving not only the myocardium but also any cardiovascular structure. Indeed, this progressive infiltrative disease also involves the cardiac valves and, specifically, shows a high prevalence with aortic stenosis. Misfolded protein infiltration in the aortic valve leads to tissue damage resulting in the onset or worsening of valve stenosis. Transthyretin cardiac amyloidosis and aortic stenosis coexist in patients > 65 years in about 4-16% of cases, especially in those undergoing transcatheter aortic valve replacement. Diagnostic workup for cardiac amyloidosis in patients with aortic stenosis is based on a multi-parametric approach considering clinical assessment, electrocardiogram, haematologic tests, basic and advanced echocardiography, cardiac magnetic resonance, and technetium labelled cardiac scintigraphy like technetium-99â m (99mTc)-pyrophosphate, 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid, and 99mTc-hydroxymethylene diphosphonate. However, a biopsy is the traditional gold standard for diagnosis. The prognosis of patients with coexisting cardiac amyloidosis and aortic stenosis is still under evaluation. The combination of these two pathologies worsens the prognosis. Regarding treatment, mortality is reduced in patients with cardiac amyloidosis and severe aortic stenosis after undergoing transcatheter aortic valve replacement. Further studies are needed to confirm these findings and to understand whether the diagnosis of cardiac amyloidosis could affect therapeutic strategies. The aim of this review is to critically expose the current state-of-art regarding the association of cardiac amyloidosis with aortic stenosis, from pathophysiology to treatment.