Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Diagnostics (Basel) ; 14(4)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38396417

RESUMO

Accurate measurement and interpretation of serum levels of troponin (Tn) is a central part of the clinical workup of a patient presenting with chest pain suspicious for acute coronary syndrome (ACS). Knowledge of the molecular characteristics of the troponin complex and test characteristics of troponin measurement assays allows for a deeper understanding of causes of false positive and false negative test results in myocardial injury. In this review, we discuss the molecular structure and functions of the constituent proteins of the troponin complex (TnT, TnC, and TnI); review the different isoforms of Tn and where they are from; survey the evolution of clinical Tn assays, ranging from first-generation to high-sensitivity (hs); provide a primer on statistical interpretation of assay results based on different clinical settings; and discuss potential causes of false results. We also summarize the advances in technologies that may lead to the development of future Tn assays, including the development of point of care assays and wearable Tn sensors for real-time continuous measurement.

2.
Am J Cardiol ; 207: 28-34, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37722198

RESUMO

Transcatheter aortic valve replacement (TAVR) generates significant debris, and strategies to mitigate cerebral embolization are needed. The novel Emboliner embolic protection catheter (Emboline, Inc., Santa Cruz, California) is designed to capture all particles generated during TAVR. This first-in-human study sought to assess the safety and feasibility of the device and to characterize the distribution and histopathology of the debris generated during TAVR. The SafePass 2 study was a prospective, nonrandomized, multicenter, single-arm investigation of the Emboliner device. Primary end points included 30-day major adverse cardiac and cerebrovascular events (MACCE) and technical performance. Computed tomography angiography was analyzed by an independent core laboratory, and filters were sent for histopathology of captured debris. Predictors of particle number were identified using >150 µm and >500 µm size thresholds. Of 31 subjects enrolled, technical success was 100%, and 30-day MACCE was 6.5% (2 cerebrovascular accidents, with 1 attributed to subtherapeutic dosing of rivaroxaban along with atrial fibrillation and the other to possible previous small ischemic strokes on magnetic resonance imaging; neither MACCE event had a causal relation to the Emboliner). All filters contained debris, with a median of 191.0 particles >150 µm and 14.0 particles >500 µm. Histopathology revealed mostly acute thrombus and valve or arterial tissue with lesser amounts of calcified tissue. A history of atrial fibrillation predicted a greater number of particles >500 µm (p = 0.0259) and its presence on admission was associated with 4.1 times more particles >150 µm (p = 0.0130) and 8.1 times more particles >500 µm (p = 0.0086). Self-expanding valves were associated with twice the number of particles >150 µm (p = 0.0281). TASK score was positively correlated with number of particles >500 µm (p = 0.0337). The Emboliner device was safe and feasible. Emboli after TAVR appear more numerous than previously documented. Atrial fibrillation, higher TASK score, and self-expanding valve use conferred higher embolic burden. Notably, none of the tested computed tomography angiography features were able to identify with higher embolic risk. Larger-scale studies are needed to identify high-risk patients for selective embolic protection device use.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Dispositivos de Proteção Embólica , Embolia , Embolia Intracraniana , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fibrilação Atrial/complicações , Fatores de Risco , Resultado do Tratamento , Embolia/epidemiologia , Embolia/etiologia , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle
4.
Cardiol Rev ; 28(4): 208-212, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32032131

RESUMO

Despite recent advances in drug-eluting stent (DES) technology, late adverse events remain concerns after percutaneous coronary intervention. The persistence of polymer material on DES has been suggested as a trigger for chronic inflammation. The Firehawk, a novel DES, has a unique design with recessed abluminal grooves, to which sirolimus and biodegradable polymer are applied. The Firehawk stent is designed to minimize polymer volume and antiproliferative drug concentration to reduce inflammation and hypersensitivity reactions. Several recent trials have reported the clinical outcomes of this device. This article provides a review of the current clinical evidence concerning the Firehawk stent.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Implantes Absorvíveis , Humanos , Inflamação/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA