Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Electrocardiol ; 61: 23-26, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32512245

RESUMO

Significant ST-segment changes raise concern for myocardial ischemia, cardiomyopathy or myocardial inflammation and therefore, warrant an extensive and often invasive cardiovascular evaluation. We report a 12 year-old asymptomatic African-American girl with marked ST-segment elevation in leads I and aVL and ST-segment depression in inferior leads II, III and aVF. Extensive cardiovascular evaluation did not reveal any abnormality suggesting that these findings, which have previously not been reported, are likely benign, at least in this young girl.


Assuntos
Infarto do Miocárdio , Isquemia Miocárdica , Arritmias Cardíacas , Criança , Depressão , Eletrocardiografia , Feminino , Humanos , Isquemia Miocárdica/diagnóstico
2.
Pediatr Cardiol ; 39(1): 120-128, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28980053

RESUMO

Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Dilatação/efeitos adversos , Desenho de Prótese/efeitos adversos , Falha de Prótese/efeitos adversos , Stents/efeitos adversos , Cateterismo Cardíaco/métodos , Dilatação/métodos , Cardiopatias Congênitas/cirurgia
3.
Catheter Cardiovasc Interv ; 89(6): 1118-1128, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28258658

RESUMO

OBJECTIVES: The study purpose is to evaluate the safety and efficacy of the ADO II device for closure of patent ductus arteriosus (PDA) in children. BACKGROUND: Transcatheter treatment of PDA has been evolving for 40+ years and is the treatment of choice. The AMPLATZER™ Duct Occluder (ADO) device was developed for larger diameter ducts and is not ideal in all PDAs. ADO II was developed for small to moderate-sized ducts. METHODS: This is a single-arm, multicenter study evaluating safety and efficacy of the ADO II device. Patients <18 years were screened for a PDA ≤5.5 mm in diameter and 3-12 mm in length. Right and left heart catheterization was performed, and hemodynamic data were obtained at the time of implant. The diameter of the left pulmonary artery (LPA) and descending aorta, and the presence of any pre-existing pressure gradients across the LPA or aortic arch were assessed at baseline and 6 months post-implant. RESULTS: A total of 192 patients were enrolled. The median implant time was 74 min. Median fluoroscopy time was 12 min. A retrograde (aortic) approach was used in 33% of procedures and demonstrated a statistically significant reduction in fluoroscopy time (P value = 0.0018) compared to an antegrade approach. The device was successfully implanted in 93% of patients, with complete closure in 98% of successful implantations. CONCLUSIONS: In this prospective study, the ADO II was safe and effective for closure of small to moderate PDAs. Implantation is simple and the ability for retrograde aortic delivery reduces procedure-related radiation exposure. © 2017 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adolescente , Aortografia , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Hemodinâmica , Humanos , Lactente , Masculino , Estudos Prospectivos , Desenho de Prótese , Doses de Radiação , Exposição à Radiação/prevenção & controle , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
4.
Congenit Heart Dis ; 11(6): 741-750, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27463050

RESUMO

OBJECTIVE: Intravascular stents are now routinely used to treat young patients with vascular stenoses. Future stent redilations are often necessary to account for somatic growth. The purpose of this study was to compile a database of characteristics for stents commonly used in the treatment of congenital heart disease patients, and compare serial dilation to direct dilation to the maximal diameter. DESIGN: A standardized bench testing protocol was established and utilized in the assessment of all stents. Ultra high pressure balloons were used to serially dilate each stent by set increments until the stent reached at least 24 mm in diameter, developed a napkin-ring configuration, or fractured. Length and diameter of each stent were measured at baseline and following each stage of dilation. Maximal stent diameters, foreshortening properties, and ability to fracture were reported. Stents were then tested for direct dilation from the primary diameter to the maximal diameter, and the same data was obtained. RESULTS: A total of 127 stents were bench-tested, 80 of which were serially dilated and 47 directly dilated. Most premounted stents could be serially dilated to approximately twice their stated nominal diameter. All tested unmounted stents could be serially dilated to ≥20 mm. Foreshortening occurred at larger diameters, but varied significantly among different stent types. Serial dilation offered more consistent results with significantly less foreshortening and more symmetric expansion when compared with direct dilation. Most premounted stents could be fractured when serially dilated. CONCLUSIONS: All tested vascular stents can be dilated beyond their nominal implantation diameter. Serial dilation offers a much more reliable response with uniform expansion, less foreshortening, greater maximal diameter, and improved intentional fracture potential, as compared to direct dilation from the nominal to maximal diameter. In vivo studies are necessary to corroborate these findings in the congenital heart disease population.


Assuntos
Angioplastia com Balão/instrumentação , Cardiopatias Congênitas/complicações , Stents , Doenças Vasculares/terapia , Bases de Dados Factuais , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Pressão , Desenho de Prótese , Falha de Prótese , Estresse Mecânico , Doenças Vasculares/etiologia
5.
J Vet Cardiol ; 18(1): 79-87, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26777393

RESUMO

An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation.


Assuntos
Coração Triatriado/veterinária , Doenças do Cão/terapia , Forame Oval Patente/veterinária , Stents/veterinária , Animais , Coração Triatriado/terapia , Cães , Cuidados Paliativos
6.
Catheter Cardiovasc Interv ; 87(2): 302-9, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26527119

RESUMO

OBJECTIVES: We sought to develop a scoring system that predicts the risk of serious adverse events (SAE's) for individual pediatric patients undergoing cardiac catheterization procedures. BACKGROUND: Systematic assessment of risk of SAE in pediatric catheterization can be challenging in view of a wide variation in procedure and patient complexity as well as rapidly evolving technology. METHODS: A 10 component scoring system was originally developed based on expert consensus and review of the existing literature. Data from an international multi-institutional catheterization registry (CCISC) between 2008 and 2013 were used to validate this scoring system. In addition we used multivariate methods to further refine the original risk score to improve its predictive power of SAE's. RESULTS: Univariate analysis confirmed the strong correlation of each of the 10 components of the original risk score with SAE attributed to a pediatric cardiac catheterization (P < 0.001 for all variables). Multivariate analysis resulted in a modified risk score (CRISP) that corresponds to an increase in value of area under a receiver operating characteristic curve (AUC) from 0.715 to 0.741. CONCLUSION: The CRISP score predicts risk of occurrence of an SAE for individual patients undergoing pediatric cardiac catheterization procedures.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Técnicas de Apoio para a Decisão , Cardiopatias Congênitas/terapia , Pediatria/métodos , Adolescente , Fatores Etários , Área Sob a Curva , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Recém-Nascido , Modelos Logísticos , Análise Multivariada , Valor Preditivo dos Testes , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 84(5): 785-93, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24585540

RESUMO

OBJECTIVES: We examine normalized air Kerma area product (PKA ) by body weight (PKA /BW) as a reference value of radiation dose and benchmark PKA /BW in pediatric laboratories using a multicenter registry database. BACKGROUND: Reduction of radiation dose is an important quality improvement task in pediatric cardiac catheterization laboratories. Physicians need to agree on a standard method of reporting radiation dose that would allow comparisons to be made between operators and institutions. METHODS: This was a multicenter observational study of radiation dose in pediatric laboratories. Patient demographic, procedural and radiation data including fluoroscopic time and PKA (µGy m(2) ) were analyzed. PKA /BW was obtained by indexing PKA to body weight. RESULTS: A total of 8,267 pediatric catheterization procedures (age <18 years) were included from 16 institutions. The procedures consisted of diagnostic (n = 2,827), transplant right ventricular (RV) biopsy (n = 1,172), and interventional catheterizations (n = 4268). PKA correlated with body weight better than with age and best correlated with weight-fluoroscopic time product. PKA /BW showed consistent values across pediatric ages. Interventional catheterizations had the highest PKA /BW (50th, 75th, and 90th percentiles: 72, 151, and 281 µGy m(2) /kg), followed by diagnostic (59, 105, and 175 µGy m(2) /kg) and transplant RV biopsy (27, 79, and 114 µGy m(2) /kg). CONCLUSION: PKA /BW appeared to be the most reliable standard to report radiation dose across all procedure types and patient age. We recommend PKA /BW to be used as the standard unit in documenting radiation usage in pediatric laboratories and can be used to evaluate strategies to lower radiation dosage in pediatric patients undergoing cardiac catheterizations. © 2014 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/normas , Doses de Radiação , Proteção Radiológica/normas , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Serviço Hospitalar de Cardiologia , Criança , Pré-Escolar , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Humanos , Lactente , Laboratórios Hospitalares , Segurança do Paciente , Pediatria/métodos , Sistema de Registros , Medição de Risco , Estatísticas não Paramétricas , Fatores de Tempo
8.
Am J Cardiol ; 112(2): 286-91, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23587279

RESUMO

The risk factors for superior vena cava (SVC) obstruction after pediatric orthotopic heart transplantation (OHT) have not been identified. This study tested the hypothesis that pretransplant superior cavopulmonary anastomosis (CPA) predisposes patients to SVC obstruction. A retrospective review of the Pediatric Cardiac Care Consortium registry from 1982 through 2007 was performed. Previous CPA, other cardiac surgeries, gender, age at transplantation, and weight at transplantation were assessed for the risk of developing SVC obstruction. Death, subsequent OHT, or reoperation involving the SVC were treated as competing risks. Of the 894 pediatric OHT patients identified, 3.1% (n = 28) developed SVC obstruction during median follow-up of 1.0 year (range: 0 to 19.5 years). Among patients who developed SVC obstruction, 32% (n = 9) had pretransplant CPA. SVC surgery before OHT was associated with posttransplant development of SVC obstruction (p <0.001) after adjustment for gender, age, and weight at OHT and year of OHT. Patients with previous CPA had increased risk for SVC obstruction compared with patients with no history of previous cardiac surgery (hazard ratio 10.6, 95% confidence interval: 3.5 to 31.7) and to patients with history of non-CPA cardiac surgery (hazard ratio 4.7, 95% confidence interval: 1.8 to 12.5). In conclusion, previous CPA is a significant risk factor for the development of post-heart transplant SVC obstruction.


Assuntos
Derivação Cardíaca Direita/efeitos adversos , Transplante de Coração/efeitos adversos , Síndrome da Veia Cava Superior/epidemiologia , Síndrome da Veia Cava Superior/etiologia , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
9.
Pediatr Transplant ; 17(3): 294-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23464863

RESUMO

PE can occur following HCT. However, the incidence, etiology, risk factors, and treatment remain unclear. We performed a retrospective study evaluating 355 pediatric recipients of HCT treated at a single institution between January 2005 and August 2010. No cases of PE were identified in the autologous HCT (auto-HCT) recipients (0/43), while 19% (57/296) of allogeneic HCT (allo-HCT) developed PE. Among the 57 PE patients, 40 (70%) were males; the median age at transplantation was 6.6 yr (0.1-17.3 yr). Thirty-six patients (63%) had significant PE with 23 patients (40%) treated by pericardiocentesis, and 19 (33%) experiencing recurrent PE. OS rates for patients who developed PE were 84% at 100 days and 65% at three yr after HCT. Risk factors associated with PE on multivariate analysis included myeloablative conditioning (p = 0.01), delayed neutrophil engraftment (p < 0.01), and CMV + serostatus of the recipient (p = 0.03). Recipients with non-malignant diseases were significantly less likely to die after development of PE (p = 0.02 and 0.004 when comparing with standard and high-risk diseases, respectively). In summary, PE is a common and significant complication of pediatric allo-HCT. Prospective studies are needed to better determine the etiology and optimal method of PE treatment after HCT.


Assuntos
Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Derrame Pericárdico/diagnóstico , Adolescente , Criança , Pré-Escolar , Infecções por Citomegalovirus/complicações , Feminino , Transplante de Células-Tronco Hematopoéticas/métodos , Humanos , Lactente , Masculino , Neutrófilos/citologia , Pericardiocentese/métodos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Estações do Ano , Fatores de Tempo , Condicionamento Pré-Transplante/efeitos adversos , Condicionamento Pré-Transplante/métodos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 74(3): 482-7, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19405162

RESUMO

OBJECTIVES: To describe a new percutaneous PDA device. BACKGROUND: The ADO II was developed by AGA Medical for closure of small-moderate sized PDAs via a small delivery catheter from an antegrade or retrograde catheter approach. The objective of this study was to evaluate the technical feasibility, safety, and efficacy of the ADO II in a canine PDA model. METHODS: The ADO-II consists of multi-layer nitinol wire braid with symmetric retention disks and an articulating connecting center waist, without sewn-in polyester, that can be delivered though a 4-5F catheter. A PDA was surgically created in nine dogs. Transcatheter occlusion of the PDA was performed using the ADO II. Angiographic and hemodynamic data were obtained at 7, 30, 60, and 90 days post-procedure. The devices were then harvested for pathology. RESULTS: Devices were placed transarterially (n = 8) and transvenously (n = 1). All PDAs were occluded and there were no significant pressure gradients (P > 0.05) at the immediate and 90 post-implant evaluations. Pathology found endothelial coverage on all aortic and pulmonary disks, except at the tip of the microscrew. There were no procedural complications. One canine was euthanized 4 hr after device implant because of a clinical deterioration. The staff veterinarian and pathologist concluded that the animal's illness was not device related. CONCLUSIONS: The Amplatzer ADO II devices can be safely deployed in animal models of PDAs, with complete resolution of the PDA shunt. The lower profile and symmetry of the ADO II allows for venous or arterial approach and smaller delivery catheter size. The ADO-II is expected to be a preferred alternative for closure of small-moderate PDAs.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Animais , Aorta/fisiopatologia , Aortografia , Cateterismo Cardíaco/efeitos adversos , Modelos Animais de Doenças , Cães , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Hemodinâmica , Masculino , Teste de Materiais , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fatores de Tempo
11.
J Invasive Cardiol ; 20(2): E41-3, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18252976

RESUMO

We report a unique combination of PDA stent placement and occlusion of a persistent cavo-atrial connection in an adult with complex cyanotic congenital heart disease. The unusual anatomy and physiology with prior palliative surgery were amenable to catheterization intervention and have resulted in marked clinical improvement.


Assuntos
Permeabilidade do Canal Arterial/terapia , Átrios do Coração/cirurgia , Cardiopatias Congênitas/terapia , Stents , Veia Cava Superior/cirurgia , Adulto , Cateterismo Cardíaco , Feminino , Átrios do Coração/anormalidades , Cardiopatias Congênitas/complicações , Humanos , Veia Cava Superior/anormalidades
12.
J Interv Cardiol ; 16(5): 367-70, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14603791

RESUMO

PURPOSE: In circulations with pulsatile pulmonary artery flow the pulmonary venous wedge pressure (PVWp) has been validated as a good estimate of pulmonary artery pressure (PAp), when PAp is low. The purpose of this study was to validate PVWp estimates of PAp in the less-pulsatile pulmonary circulation of children after bidirectional Glenn shunts. METHODS: A retrospective study was performed of 22 simultaneous measurements of PVWp and PAp made during 20 catheterizations in 19 children who had undergone bidirectional Glenn procedures. The PAp was measured directly from the branch PA ipsilateral to the side of the PVWp, or in the SVC. Pulmonary resistance (Rp) was calculated with both PAp and PVWp, to assess the impact of PAp estimates on Rp determinations. RESULTS: Patients ranged in age from 5 months to 10.7 years. There were a variety of univentricular cardiac malformations in the study group. Two children had antegrade pulmonary blood flow in addition to a bidirectional Glenn shunt. The mean PAp ranged from 4 to 14 mmHg, while mean PVWp ranged from 3 to 15 mmHg. Mean PVWp never differed from mean PAp by more than 3 mmHg. There was a significant linear relation between mean PAp and PVWp: PAp = 0.86 (PVWp) + 2.0 (R2 = 0.89; P < 0.0001). PVWp provided a good approximation of PAp regardless of the presence (n = 2) or absence (n = 19) of antegrade pulmonary flow. There was a good linear correlation between the Rp calculated by both methods (RpPAp = 0.9 (RpVWp) + 0.5; R2 = 0.74; P < 0.0001). CONCLUSION: The mean PVWp provides a close approximation of mean PAp in children with a bidirectional Glenn shunt and provides valuable hemodynamic information in cases where direct PAp measurements are unavailable.


Assuntos
Derivação Arteriovenosa Cirúrgica , Cardiopatias Congênitas/fisiopatologia , Artéria Pulmonar/fisiopatologia , Pressão Propulsora Pulmonar , Cateterismo Cardíaco , Criança , Pré-Escolar , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Artéria Pulmonar/cirurgia , Circulação Pulmonar/fisiologia , Estudos Retrospectivos , Veias Cavas/cirurgia , Função Ventricular Direita/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA