Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Curr Opin Otolaryngol Head Neck Surg ; 32(3): 193-199, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38547365

RESUMO

PURPOSE OF REVIEW: The purpose of this review is to examine current practices in surgical equipment donation to lower- and middle-income countries (LMICs) with a particular focus on otolaryngology-head and neck surgery (OHNS). This is designed as a pragmatic review to guide potential donor communities to implement sustainable OHNS equipment donation in LMICs. RECENT FINDINGS: LMICs are increasingly reliant on international equipment donation. In terms of OHNS services, global OHNS have compiled a list of essential equipment for baseline care in LMICs. Especially in terms of audiology, OHNS equipment donation has the potential to have a significant impact on populational health. However, there is a scarcity of research on donated equipment in OHNS. A suggested blueprint for sustainable equipment donation follows these steps: establish partnerships, assess needs, source equipment, and follow-up and evaluate the intervention. Key further considerations for sustainability include remanufacturing and repurposing methods, maintenance, and contextual understanding. SUMMARY: Sustainable equipment donation in otolaryngology is an important part of global health equity and healthcare delivery in low-resource settings. Despite the good intentions behind medical equipment donations, there are many challenges; donors and recipients should engage in collaborative, needs-based planning processes that result in long-term sustainability, local capacity building, and community participation.


Assuntos
Países em Desenvolvimento , Otolaringologia , Humanos , Saúde Global
2.
Eur J Vasc Endovasc Surg ; 67(1): 119-129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37572869

RESUMO

OBJECTIVE: Despite widespread use, long term outcomes for fenestrated endovascular aneurysm repair (FEVAR) are uncertain. This meta-analysis reports long term survival, freedom from re-intervention, target vessel patency, and one year sac regression after FEVAR. DATA SOURCES: Systematic review and meta-analysis to pool time to event data according to PRISMA guidelines. The study was registered with the international prospective register of systematic reviews (PROSPERO) (ID: CRD42023401468). REVIEW METHODS: Medline, Embase, and Cochrane databases were searched from 1992 - 2023; articles were independently screened by two authors. Publication of complete time to event data for any outcome of interest was an inclusion criterion. Raw Kaplan-Meier probabilities were directly extracted from published curves and pooled by random effects. Risk of bias was assessed using ROBINS I and certainty with GRADE. RESULTS: A total of 3 569 records were retrieved, 2 869 screened after duplicate removal, yielding 37 included studies (n = 4 371). The pooled mean age was 73.2 years (interquartile range [IQR] 72.2, 73.7) and 87.4% were male (95% confidence interval [CI] 85.8 - 88.9). Pooled Kaplan-Meier estimated probabilities of survival (n = 34 studies, n = 4 192 patients) at one, three, and five years were 91.6% (95% CI 90.2 - 92.9), 80.8% (95% CI 78.0 - 83.2), and 65.1% (95% CI 60.9 - 69.1). For freedom from re-intervention (n = 24, n = 3 211 patients) at one, three, and five years these were 90.2% (95% CI 87.3 - 92.7), 80.9% (95% CI 76.5 - 84.9), and 73.8% (95% CI 67.1 - 79.6). For target vessel patency (n = 13, n = 5805 target vessels) at one, three, and five years, these were 96.6% (95% CI 94.9 - 98.0), 94.5% (95% CI 91.7 - 96.7), and 93.1% (95% CI 89.3 - 96.0). Pooled estimate of sac regression (n = 8, n = 560) at one year was 40.2% (95% CI 28.9 - 52.7). Risk of bias was judged as moderate in 11 studies and low for the remaining 26. CONCLUSION: There are moderate to low certainty data supporting reasonable long term outcome estimates following fenestrated endovascular aneurysm repair. Beyond five years there is a lack of data in the literature.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Prótese Vascular , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese
3.
Heart ; 108(21): 1707-1715, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-34702756

RESUMO

OBJECTIVE: Nickel allergy is common; endovascular specialists are often confronted with nickel allergic patients ahead of the implantation of endovascular devices, many of which are nickel-containing. Our aim was to elucidate whether nickel hypersensitivity is significantly associated with worse or adverse outcomes after placement of a nickel-containing endovascular device. METHODS: Inclusion criteria were: endovascular and transcatheter procedures for coronary, structural heart, neurovascular and peripheral vascular pathology involving nickel-allergic patients. All adverse outcomes were included as defined by included studies. A systematic review and meta-analysis were undertaken using a random-effects model. Searches of MEDLINE and EMBASE were conducted for articles published 1947-2019. RESULTS: 190 records were identified, 78 articles were included for qualitative synthesis and 15 met criteria for meta-analysis. Patch-test confirmed nickel allergy was associated with an increased risk of adverse outcomes following implantation of a nickel-containing endovascular device (n=14 articles, 1740 patients; OR 2.61, 95% CI 1.41 to 4.85). This finding further was observed in coronary (n=12 articles, 1624 patients; OR 1.94, 95% CI 1.16 to 3.23) and structural heart subgroups (n=2 articles, 83 patients; OR 52.28, 95% CI 1.31 to 2079.14), but not in the neurovascular subgroup (n=1 article, 33 patients; OR 3.04, 95% CI 0.59 to 15.72) or with a patient-reported history of nickel allergy (n=2 articles, 207 patients; OR 2.14, 95% CI 0.23 to 19.70). CONCLUSIONS: Patch-tested nickel allergy is associated with an increased risk of adverse outcomes following endovascular device implantation and alternative treatment options should be considered. Specialists faced with patients' self-reporting nickel allergy should consider proceeding to diagnostic patch-testing.


Assuntos
Procedimentos Endovasculares , Hipersensibilidade , Procedimentos Endovasculares/efeitos adversos , Humanos , Hipersensibilidade/diagnóstico , Hipersensibilidade/epidemiologia , Hipersensibilidade/etiologia , Níquel/efeitos adversos , Testes do Emplastro/efeitos adversos , Resultado do Tratamento
5.
J Endovasc Ther ; 27(3): 428-435, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32517557

RESUMO

Purpose: To investigate the long-term outcomes of endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysm (rAAA) from a single center over an 11-year period. Materials and Methods: A retrospective analysis was conducted of 121 patients (median age 78 years; 100 men) with rAAA who underwent emergency EVAR at a single tertiary vascular center from January 2006 to December 2016. The study included only ruptures confirmed by evidence of hematoma on preoperative computed tomography; both iliac and aortic aneurysm ruptures were eligible. The primary outcome measures included mortality and reintervention rates. Kaplan-Meier estimates of survival and freedom from reintervention are reported with the 95% confidence interval (CI). Results: In-hospital and 30-day mortality rates for emergency EVAR were 16.5%; 90-day mortality was 24.0%. The mortality estimates were 27.3% (95% CI 20% to 36%) at 1 year and 61.7% (95% CI 51% to 72%) at 5 years. In the observation period to 2017, 63 reinterventions were performed on 37 patients (30.6%). Median time to the first reintervention was 3.2 years. Freedom from reintervention in surviving patients at 1 year was 86% (95% CI 72% to 94%) and 51% (95% CI 26% to 71%) at 5 years. Four patients (3.3%) had a secondary sac rupture over the study period. Conclusion: Emergency EVAR for ruptured AAA can be performed with acceptable short-term outcomes; however, long-term surveillance is necessary, and reintervention is common.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Intervalo Livre de Progressão , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
6.
BMJ Case Rep ; 12(9)2019 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-31551320

RESUMO

Brown tumours are rare osteolytic lesions that occur secondary to hyperparathyroidism (HPT). In 2% of all cases, the craniofacial bones are affected, most frequently the mandible. HPT is classified according to aetiology into three types, of which tertiary HPT is the rarest. Here we present the case of a 42-year-old man who had received a renal transplant 16 years previously and was referred due to swelling on the right side of his jaw. An orthopantomogram revealed a multilocular radiolucency in the right body of the mandible. The bony lesion was treated by surgical enucleation. After histopathological examination of the lesion, the diagnosis of brown tumour of the mandible secondary to tertiary HPT was reached. The patient's recovery was uneventful and follow-up radiography showed good bone healing.


Assuntos
Hiperparatireoidismo Secundário/complicações , Transplante de Rim , Neoplasias Mandibulares/etiologia , Neoplasias Mandibulares/cirurgia , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Neoplasias Mandibulares/diagnóstico por imagem , Radiografia Panorâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA