Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Clin Res Cardiol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695900

RESUMO

BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38632135

RESUMO

BACKGROUND: Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS: Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS: The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION: CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.

3.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38516791

RESUMO

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluxo de Trabalho , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva
4.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885302

RESUMO

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos
5.
Stud Health Technol Inform ; 309: 145-149, 2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37869828

RESUMO

Health organizations face barriers when seeking to deploy radical innovations, such as innovative telemonitoring approaches or AI based Clinical Decision Support Systems (CDSS) into their clinical workflow. However, these barriers are of various types and rarely known to organizations and their management. This study conducted a systematic literature review of 99 selected studies to identify the implementation barriers and factors encountered in this process. Using a hierarchical framework comprising of strategies, resources and capabilities, and processes, the study examined 16 barriers generated from the analysis of the individual studies. The findings highlight implementation barriers on all three levels of the proposed framework. By addressing these barriers comprehensively, health care organizations can successfully implement radical health innovations and enhance patient care outcomes and health care delivery.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Atenção à Saúde , Humanos , Organizações
7.
Pacing Clin Electrophysiol ; 46(7): 714-716, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37247251

RESUMO

BACKGROUND: Pulsed field ablation (PFA) results in unique lesion formation, but there is lack of in-vivo validation in terms of scar formation following atrial fibrillation (AF) ablation. OBJECTIVE: We aimed to access atrial lesion formation based on late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) following PFA for pulmonary vein (PV) and posterior wall isolation (PWI). METHODS: AF ablation was performed in 10 patients using a 31 mm pentaspline PFA catheter. After pulmonary vein isolation (PVI; n = 8 PFA-applications/ PV; n = 4 in basket and n = 4 in flower configuration), another eight applications in flower configuration were conducted for concomitant PWI. Patients underwent LGE CMR 3 months after ablation aiming for quantification of left atrial (LA) scar. RESULTS: Acute procedural success was achieved in all patients. Mean procedure duration was 62 ± 7 min. and mean LA dwell time of the PFA catheter was 13 ± 2 min. Mean post ablation total LA scar burden was 8.1 ± 2.1% and mean scar width was 12.8 ± 2.1 mm. At the posterior LA, 22.6 ± 2.2% of the anatomical segment resulted in chronic scar tissue, concentrated at the PW. Postablation CMR found no evidence for PV stenosis or collateral damage of adjacent structures. At 7 months of follow-up, 9/10 patients (90%) were free from arrhythmia recurrence. CONCLUSION: PFA for AF resulted in durable and transmural atrial scar tissue at the PVs and PW. LGE CMR found a very homogeneous and contiguous lesion pattern with no signs for collateral damage.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Cicatriz/cirurgia , Meios de Contraste , Veias Pulmonares/cirurgia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
8.
J Interv Card Electrophysiol ; 66(9): 2125-2133, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37145294

RESUMO

BACKGROUND: Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This observational study aimed to assess the role of individual anatomical characteristics to predict long-term freedom from arrhythmia recurrence after CB-guided PVI for paroxysmal AF (PAF). METHODS: Three hundred fifty three consecutive patients (58 ± 11 years, 56% males), undergoing PVI between 2012 and 2018 were analysed. Individual pulmonary vein (PV) anatomy was assessed using preprocedural cardiac magnetic resonance imaging (MRI). For each PV, the cross-sectional area (CSA) was calculated. The impact of PV characteristics and CSA on long-term AF-free survival was evaluated. RESULTS: Acute PVI was achieved in all patients. Two hundred twenty-three patients (63%) had a normal PV anatomy (2 left- and 2 right-sided PV). Variant PV anatomy was present in 130 patients (37%). During the observation period of 48 months, AF-recurrence was documented in 167 patients (47 %). Patients with AF-recurrence presented with significantly enlarged right-sided PVs and left superior PVs (LSPVs) (p < 0.001). The presence of left common PVs (LCPVs) (n = 75, Log-rank p < 0.001) as well as right variant PVs (n = 35, Log rank p < 0.001) was associated with a significantly impaired long-term AF-free survival rate as compared to patients with normal PV characteristics. CONCLUSION: Variant PV anatomy is a good predictor for AF-recurrence. A correlation between an enlarged CSA of right-sided PVs as well as LSPVs and AF-recurrence was documented.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Imageamento por Ressonância Magnética , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
9.
Europace ; 25(4): 1392-1399, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36815300

RESUMO

AIMS: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. CONCLUSION: Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/patologia , Fluxo de Trabalho , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/patologia , Resultado do Tratamento , Recidiva
10.
Heart Vessels ; 38(7): 984-991, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36786857

RESUMO

A new automated vector-based mapping algorithm (AMA) for 3-dimensional (3D) mapping has been introduced. The aim of this study was to present our experience using AMA to recognize additional catheter ablation targets in patients with ventricular arrhythmias (VA). A total of 16 patients (ICM; ischemic cardiomyopathy, n = 6; NICM; non-ischemic cardiomyopathy n = 10) suffering from VA underwent catheter ablation. Following bipolar voltage mapping, AMA was utilized to reveal zones of decelerated conduction velocity vectors (CVV) and this information was superimposed onto the 3D reconstructions and compared with the presence of scar. Mapping time was 28.1 ± 10 min for the endocardial reconstruction of the left ventricle (LV) and 17 ± 5.4 min for the epicardium (n = 6 patients). The mean area of LV low voltage was 13.9 ± 15% (endocardial) and 11.9 ± 5.7% (epicardial). Decelerating CVV zones were revealed in all patients (mean conduction velocity threshold of 39.3 ± 13%). Sustained VA have been terminated through ablation and substrate modification was performed in all patients. Correlation between the presence of CVV deceleration zones and areas of abnormal low voltage from bipolar mapping was revealed in only 37.5% of patients, but there was good correlation between scar from unipolar voltage mapping and the presence of CCV deceleration zones (94%; p = 0.008). The novel AMA may improve the understanding of individual VA substrates due to the visualization of decelerated CVV zones and their correlation with abnormal low voltage predominantly from unipolar mapping.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Cicatriz/cirurgia , Ventrículos do Coração , Arritmias Cardíacas , Ablação por Cateter/métodos
11.
Cardiol J ; 30(1): 36-43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36588311

RESUMO

BACKGROUND: The DiamondTemp (DT) radiofrequency ablation (RFA) catheter has been introduced as a new tool for atrial fibrillation (AF) ablation. The new technology allows for temperature-controlled irrigated ablation and real-time lesion assessment. Recently, the EnSite X mapping system became commercially available allowing for omnipolar and ultra-high-resolution mapping. We aimed to assess the feasibility of the new DT RFA catheter in performing AF ablation procedures in conjunction with the novel EnSite X system under routine clinical conditions. METHODS: We analyzed data from 10 consecutive patients who underwent AF ablation using the DT RFA catheter guided by EnSite X. Procedural data and short-term follow-up were assessed as well as potential technical issues. RESULTS: Nine out of 10 patients underwent de-novo pulmonary vein isolation (PVI), and 1 patient underwent repeat ablation. First-pass isolation was observed in 7/10 patients. Total procedure duration (skin-to-skin) was 88.9 ± 30.1 min, and left atrium dwell time was 70 ± 22.3 min. The mean number of RF applications needed for PVI and additional ablation was 70.52 ± 26.70. The HD Grid SE mapping catheter was utilized in 8 patients and the Advisor SE in 2 patients. Bidirectional block of the applied lines was achieved in all patients. No steam pops were observed, and no intraprocedural complications occurred. CONCLUSIONS: This first clinical series demonstrated that temperature-controlled irrigated ablation in combination with the novel omnipolar and high-resolution mapping system resulted in rapid, efficient, and durable lesion formation under routine clinical conditions. Randomized controlled trials are needed to elucidate the impact on lesion formation, long-term outcomes, and reproducibility of our initial findings.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Desenho de Equipamento , Catéteres , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
12.
ESC Heart Fail ; 10(1): 284-294, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36208130

RESUMO

AIMS: Baroreflex activation therapy (BAT) is an innovative treatment option for advanced heart failure (HFrEF). We analysed patients' BAT acceptance and the outcome of BAT patients compared with HFrEF patients solely treated with a guideline-directed medical therapy (GDMT) and studied effects of sacubitril/valsartan (ARNI). METHODS: In this prospective study, 40 HFrEF patients (71 ± 3 years, 20% female) answered a questionnaire on the acceptance of BAT. Follow-up visits were performed after 3, 6, and 12 months. Primary efficacy endpoints included an improvement in QoL, NYHA class, LVEF, HF hospitalization, NT-proBNP levels, and 6MHWD. RESULTS: Twenty-nine patients (73%) showed interest in BAT. Ten patients (25%) opted for implantation. BAT and BAT + ARNI patients developed an increase in LVEF (BAT +10%, P-value (P) = 0.005*; BAT + ARNI +9%, P = 0.049*), an improved NYHA class (BAT -88%, P = 0.014*, BAT + ARNI -90%, P = 0.037*), QoL (BAT +21%, P = 0.020*, BAT + ARNI +22%, P = 0.012*), and reduced NT-proBNP levels (BAT -24%, P = 0.297, BAT + ARNI -37%, P = 0.297). BAT HF hospitalization rates were lower (50%) compared with control group patients (83%) (P = 0.020*). CONCLUSIONS: Although BAT has generated considerable interest, acceptance appears to be ambivalent. BAT improves outcome with regard to LVEF, NYHA class, QoL, NT-proBNP levels, and HF hospitalization rates. BAT + ARNI resulted in more pronounced effects than ARNI alone.


Assuntos
Insuficiência Cardíaca , Humanos , Feminino , Masculino , Insuficiência Cardíaca/terapia , Barorreflexo/fisiologia , Estudos Prospectivos , Qualidade de Vida , Volume Sistólico/fisiologia , Inibidores Enzimáticos/farmacologia , Cardiotônicos
13.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
14.
Front Cardiovasc Med ; 9: 956627, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36247422

RESUMO

Background: Ventricular fibrillation (VF) is a leading cause of cardiovascular death worldwide. However, recurrence rates of arrhythmia are high leading to mortality and morbidity. Recently, Purkinje fibers have been identified as potential sources of VF initiation and maintenance. Aim: The study analyzes the feasibility and effectiveness of catheter ablation in patients with recurrent VF by specific Purkinje de-networking (PDN). Methods: Consecutive patients with recurrent VF undergoing PDN were included in this observational study. The procedural endpoint was the non-inducibility of sustained ventricular arrhythmia. A three-dimensional -anatomical mapping was conducted, and the specific cardiac conduction system and Purkinje fibers were tagged. All detectable Purkinje signals were ablated in the left ventricle (LV). Additional right ventricular (RV) PDN was performed in case of VF inducibility after LV ablation. Follow-up was performed by patient visits at our outpatient clinic including device interrogation and by telephone interviews. Results: Eight patients were included in the study. Six patients were females (75%); the median age during the procedure was 43 [37;57] years and the median body mass index was 24 [23;33] kg/m2. Four patients (50%) had known structural heart disease with two cases of ischemic cardiomyopathy and two cases of dilated cardiomyopathy. In four patients (50%), no underlying structural heart disease could be identified. The median LV ejection fraction was 42 ± 16.4%. All patients had an implantable cardioverter-defibrillator (ICD) prior to ablation with documentation of recurrent VF. The median number of ICD shocks before the ablation was 5 [3;7]. LV PDN was performed in all patients. In two patients (25%), an additional RV PDN was performed. Non-inducibility of any ventricular arrhythmia was achieved in all patients after PDN. Two patients showed complete left bundle branch block post-ablation. The median follow-up duration was 264 [58;421] days. Two patients (25%) experienced ventricular arrhythmia recurrence with recurrent ICD-shock delivery. One patient died during follow-up with an unknown cause of death. Six patients (75%) experienced no arrhythmia recurrence during follow-up. Conclusion: Purkinje de-networking represents a novel treatment option for patients with recurrent VF without arrhythmia substrate or specific arrhythmia triggers with promising results in terms of efficiency and feasibility. Larger and more prospective studies are needed for a systematic evaluation.

15.
J Cardiovasc Electrophysiol ; 33(12): 2606-2613, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36218022

RESUMO

INTRODUCTION: Atrioventricular (AV)-node ablation (AVNA) is a common therapy option for rate control strategy of permanent atrial fibrillation (AF). We hypothesized that isolation of the AV nodal isolation (AVNI) is associated with a more frequent preservation of an adequate escape rhythm compared to AVNA. METHODS: This retrospective study included 20 patients with therapy-refractory AF being treated with AVNI and 40 historical AVNA-controls. In AVNI the AV-node region was mapped using a 3D mapping system. Ablation was performed around the previously mapped HIS-cloud regions isolating the atrium from the AV-node. In the AVNI group, ablation was performed with irrigated tip ablation catheter in all cases. The two approaches were compared regarding rate of escape rhythm, delta QRS, and procedural data. RESULTS: The number of patients with adequate escape rhythm in AVNI was significantly superior to AVNA immediately postoperative (90% vs. 40%, p < 0.01) and during follow-up (77% vs. 36%, p < 0.05). The median change in QRS width was 0 ms in AVNI versus +26 ms in AVNA (p < 0.01). Thirty percent new bundle branch blocks in AVNA were observed compared to 0% in AVNI (p < 0.01). In the AVNI group, fluoroscopy time and total dose area product were significantly lower (p < 0.01). CONCLUSION: The present study suggests that AV-node isolation using 3D navigation mapping system is a feasible and effective alternative to conventional AVNA. The precise application of radiofrequency lesions preserves a stable AV-junctional rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Retrospectivos , Nó Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia
16.
J Cardiovasc Electrophysiol ; 33(12): 2517-2527, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36104929

RESUMO

INTRODUCTION: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation. METHODS: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated. RESULTS: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy. CONCLUSION: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
17.
Herz ; 47(5): 410-418, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-35849125

RESUMO

Diabetes mellitus and atrial fibrillation show a steady increase in their prevalence. Diabetes mellitus is a relevant risk factor for the development and maintenance of atrial fibrillation, which should not be underestimated. Fluctuations in blood glucose levels occurring in diabetes, inflammatory processes and oxidative stress lead to structural, electromechanical, electrical and autonomic remodelling processes in the myocardium that promote atrial fibrillation. When atrial fibrillation and diabetes mellitus coincide, this is often associated with more pronounced symptoms, lower quality of life, more frequent hospitalization and a higher mortality rate. Can early and consistent euglycemic blood glucose monitoring effectively influence atrial remodelling processes, cardiovascular end points and the occurrence of atrial fibrillation? Are there new and combined drug treatment approaches for diabetes mellitus and atrial fibrillation? What ablation strategy should be adopted for the interventional treatment of atrial fibrillation in patients with diabetes mellitus? This review article attempts to find answers to these questions.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus/terapia , Humanos , Qualidade de Vida
18.
J Clin Med ; 11(11)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35683537

RESUMO

Aims: The present study aims to evaluate magnetic-resonance-imaging (MRI)-assessed left atrial strain (LAS) and left atrial strain rate (LASR) as potential parameters for the diagnosis of cardiac amyloidosis (CA), the distinction of clinical subtypes and differentiation from other cardiomyopathies. Methods and results: LAS and LASR were assessed by MRI feature tracking in patients with biopsy-proven CA. LAS and LASR of patients with CA were compared to healthy subjects and patients with hypertrophic cardiomyopathy. LAS and LASR were also analyzed concerning differences between patients with transthyretin (ATTR) and light chain amyloidosis (AL). A total of 44 patients with biopsy-proven CA, 19 patients with hypertrophic cardiomyopathy and 24 healthy subjects were included. In 22 CA patients (50%), histological examination identified ATTR as CA subtype and AL in the remaining patients. No significant difference was observed for reservoir, conduit or booster LAS in patients with AL or ATTR. Reservoir LAS, conduit LAS and booster LAS were significantly reduced in patients with CA and HCM as compared to healthy subjects (p < 0.001). Reservoir LAS and booster LAS were significantly reduced in CA as compared to HCM patients (p < 0.001). A linear correlation was observed between LA global reservoir strain and LA-EF (p < 0.001, r = 0.5), conduit strain and global longitudinal LV strain (p < 0.001, r = 0.5), global booster strain rate and LA-EF (p < 0.001, r = 0.6) and between global booster strain rate and LA area at LVED (p < 0.0001, 0.5). Conclusions: LAS and LASR are severely impaired in patients with CA. The MRI-based assessment of LAS and LASR might allow non-invasive diagnosis and categorization of CA and its distinct differentiation from other hypertrophic phenotypes.

20.
J Interv Card Electrophysiol ; 65(1): 251-260, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35764853

RESUMO

BACKGROUND: Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This study aimed to evaluate ablation efficacy and freedom from arrhythmia recurrence using the novel POLARx compared to the Arctic Front Advance Pro (AFA) CB system including the analysis of individual PV characteristics. METHODS: A total of 687 patients underwent CB-guided ablation for AF. Arrhythmia recurrence was defined as an ECG documented episode of any AF/atrial tachycardia (AT) > 30 s. Anatomical characteristics were assessed using magnetic resonance imaging (MRI). For each PV, the cross-sectional orifice area (CSOA) was determined. Follow-up examinations were scheduled after 3, 6, and 12 months. RESULTS: Acute PVI was achieved in all patients. Twelve-month AF-free survival was similar between the groups (POLARx 43/86 (50%) vs. AFA 318/601 (53%), Log-rank (LR) p = 0.346). MRI found a comparable percentage of patients with normal PV anatomy (POLARx 71/86 (83%) vs. AFA 530/601 (85%), p = 0.162). Patients with variant PV characteristics presented with a significantly impaired 12-month AF-free survival (normal PVs 326/585 (56%) vs. variant PVs 27/102 (27%), LR p < 0.001) independent of the applied CB ablation system. PAF patients with AF recurrence presented with significantly larger CSOA of the left-sided PVs and the right superior PVs (LSPV: p < 0.001; LIPV: p < 0.001; RSPV: p < 0.001). In PERS AF, no association between CSOA and ablation outcome was observed. Multivariate analyses identified PERS AF (hazard ratio (HR) 2.504, confidence interval (CI), 1.900-3.299, p < 0.001) and variant PV anatomy (HR 2.124, CI 1.608-2.805, p < 0.001) as independent predictors for AF recurrence. CONCLUSIONS: Both CB ablation systems are associated with comparable 12-month AF-free survival rates. Variant PV anatomy seems to be predictive for AF recurrence. An association between CSOA and the outcome after CB-guided PVI was demonstrated for PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Estudos Transversais , Criocirurgia/métodos , Liberdade , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA