Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Biomaterials ; 309: 122602, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38768544

RESUMO

Endotracheal Tubes (ETTs) maintain and secure a patent airway; however, prolonged intubation often results in unintended injury to the mucosal epithelium and inflammatory sequelae which complicate recovery. ETT design and materials used have yet to adapt to address intubation associated complications. In this study, a composite coating of electrospun polycaprolactone (PCL) fibers embedded in a four-arm polyethylene glycol acrylate matrix (4APEGA) is developed to transform the ETT from a mechanical device to a dual-purpose device capable of delivering multiple therapeutics while preserving coating integrity. Further, the composite coating system (PCL-4APEGA) is capable of sustained delivery of dexamethasone from the PCL phase and small interfering RNA (siRNA) containing polyplexes from the 4APEGA phase. The siRNA is released rapidly and targets smad3 for immediate reduction in pro-fibrotic transforming growth factor-beta 1 (TGFϐ1) signaling in the upper airway mucosa as well as suppressing long-term sequelae in inflammation from prolonged intubation. A bioreactor was used to study mucosal adhesion to the composite PCL-4APEGA coated ETTs and investigate continued mucus secretory function in ex vivo epithelial samples. The addition of the 4APEGA coating and siRNA delivery to the dexamethasone delivery was then evaluated in a swine model of intubation injury and observed to restore mechanical function of the vocal folds and maintain epithelial thickness when observed over 14 days of intubation. This study demonstrated that increase in surface lubrication paired with surface stiffness reduction significantly decreased fibrotic behavior while reducing epithelial adhesion and abrasion.

2.
Nat Commun ; 15(1): 3283, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637507

RESUMO

While poly(ethylene glycol) (PEG) hydrogels are generally regarded as biologically inert blank slates, concerns over PEG immunogenicity are growing, and the implications for tissue engineering are unknown. Here, we investigate these implications by immunizing mice against PEG to stimulate anti-PEG antibody production and evaluating bone defect regeneration after treatment with bone morphogenetic protein-2-loaded PEG hydrogels. Quantitative analysis reveals that PEG sensitization increases bone formation compared to naive controls, whereas histological analysis shows that PEG sensitization induces an abnormally porous bone morphology at the defect site, particularly in males. Furthermore, immune cell recruitment is higher in PEG-sensitized mice administered the PEG-based treatment than their naive counterparts. Interestingly, naive controls that were administered a PEG-based treatment also develop anti-PEG antibodies. Sex differences in bone formation and immune cell recruitment are also apparent. Overall, these findings indicate that anti-PEG immune responses can impact tissue engineering efficacy and highlight the need for further investigation.


Assuntos
Materiais Biocompatíveis , Engenharia Tecidual , Feminino , Masculino , Camundongos , Animais , Materiais Biocompatíveis/farmacologia , Osteogênese , Regeneração Óssea , Polietilenoglicóis/farmacologia , Hidrogéis/farmacologia
3.
Sci Rep ; 14(1): 2821, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308093

RESUMO

Corticosteroid-eluting endotracheal tubes (ETTs) were developed and employed in a swine laryngotracheal injury model to maintain airway patency and provide localized drug delivery to inhibit fibrotic scarring. Polycaprolactone (PCL) fibers with or without dexamethasone were electrospun onto the ETT surface PCL-only coated ETTs and placed in native airways of 18 Yorkshire swine. Regular and dexamethasone-PCL coated ETTs were placed in airways of another 18 swine injured by inner laryngeal mucosal abrasion. All groups were evaluated after 3, 7 and 14 days (n = 3/treatment/time). Larynges were bisected and localized stiffness determined by normal indentation, then sequentially matched with histological assessment. In the native airway, tissue stiffness with PCL-only ETT placement increased significantly from 3 to 7 days (p = 0.0016) and 3 to 14 days (p < 0.0001) while dexamethasone-PCL ETT placement resulted in stiffness decreasing from 7 to 14 days (p = 0.031). In the injured airway, localized stiffness at 14 days was significantly greater after regular ETT placement (23.1 ± 0.725 N/m) versus dexamethasone-PCL ETTs (17.10 ± 0.930 N/m, p < 0.0001). Dexamethasone-loaded ETTs were found to reduce laryngotracheal tissue stiffening after simulated intubation injury compared to regular ETTs, supported by a trend of reduced collagen in the basement membrane in injured swine over time. Findings suggest localized corticosteroid delivery allows for tissue stiffness control and potential use as an approach for prevention and treatment of scarring caused by intubation injury.


Assuntos
Cicatriz , Intubação Intratraqueal , Animais , Suínos , Cicatriz/tratamento farmacológico , Traqueia , Corticosteroides , Dexametasona/farmacologia
4.
J Laryngol Otol ; 138(2): 196-202, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37846168

RESUMO

OBJECTIVE: To investigate changes in neuroregenerative pathways with vocal fold denervation in response to vocal fold augmentation. METHODS: Eighteen Yorkshire crossbreed swine underwent left recurrent laryngeal nerve transection, followed by observation or augmentation with carboxymethylcellulose or calcium hydroxyapatite at two weeks. Polymerase chain reaction expression of genes regulating muscle growth (MyoD1, MyoG and FoxO1) and atrophy (FBXO32) were analysed at 4 and 12 weeks post-injection. Thyroarytenoid neuromuscular junction density was quantified using immunohistochemistry. RESULTS: Denervated vocal folds demonstrated reduced expression of MyoD1, MyoG, FoxO1 and FBXO32, but overexpression after augmentation. Healthy vocal folds showed increased early and late MyoD1, MyoG, FoxO1 and FBXO32 expression in all animals. Neuromuscular junction density had a slower decline in augmented compared to untreated denervated vocal folds, and was significantly reduced in healthy vocal folds contralateral to augmentation. CONCLUSION: Injection augmentation may slow neuromuscular degeneration pathways in denervated vocal folds and reduce compensatory remodelling in contralateral healthy vocal folds.


Assuntos
Traumatismos do Nervo Laríngeo Recorrente , Paralisia das Pregas Vocais , Animais , Suínos , Prega Vocal/cirurgia , Prega Vocal/patologia , Traumatismos do Nervo Laríngeo Recorrente/cirurgia , Paralisia das Pregas Vocais/genética , Paralisia das Pregas Vocais/cirurgia , Músculos Laríngeos/patologia , Nervo Laríngeo Recorrente/cirurgia , Expressão Gênica
5.
Laryngoscope Investig Otolaryngol ; 8(4): 939-945, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37621281

RESUMO

Objective: Inhalational burns frequently lead to dysphonia and airway stenosis. We hypothesize local dexamethasone delivery via a novel drug-eluting electrospun polymer-mesh endotracheal tube (ETT) reduces biomechanical and histologic changes in the vocal folds in inhalational burn. Methods: Dexamethasone-loaded polymer mesh was electrospun onto ETTs trimmed to transglottic endolaryngeal segments and secured in nine Yorkshire Crossbreed swine with directed 150°C inhalation burns. Uncoated ETTs were implanted in nine additional swine with identical burns. ETT segments were maintained for 3 and 7 days. Vocal fold (VF) structural stiffness was measured using automated-indentation mapping and compared across groups and to four uninjured controls, and matched histologic assessment performed. Statistical analysis was conducted using two-way ANOVA with Tukey's post hoc test and Wilcoxon rank-sum test. Results: VF stiffness after burn decreased with longer intubation, from 19.4 (7.6) mN/mm at 3 days to 11.3 (5.2) mN/mm at 7 days (p < .0001). Stiffness similarly decreased with local dexamethasone, from 25.9 (17.2) mN/mm at 3 days to 18.1 (13.0) mN/mm at 7 days (p < .0001). VF stiffness in the dexamethasone group was increased compared to tissues without local dexamethasone (p = .0002), and all groups with ETT placement had higher tissue stiffness at 3 days (p < .001). No significant change in histologic evidence of epithelial ulceration or fibrosis was noted, while an increased degree of inflammation was noted in the dexamethasone group (p = .04). Conclusion: Local dexamethasone delivery increases VF stiffness and degree of inflammation compared to uncoated ETTs in an acute laryngeal burn model, reflected in early biomechanical and histologic changes in an inhalational burn model.

6.
Perfusion ; : 2676591221130175, 2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36196521

RESUMO

BACKGROUND: Patients with kidney failure are at risk for lethal complications from hyperkalemia. Resuscitation, medications, and hemodialysis are used to mitigate increased potassium (K+) levels in circulating blood; however, these approaches may not always be readily available or effective, especially in a resource limited environment. We tested a sorbent cartridge (KC, K+ontrol CytoSorbents Medical Inc., Monmouth Junction, New Jersey) which contains a resin adsorber for K+. The objective of this study was to test the utility of KC in an ex vivo circulation system. We hypothesized that KC reduces K+ levels in extracorporeal circulation of donor swine whole blood infused with KCl. METHODS: A six-hour circulation study was carried out using KC, a NxStage (NxStage Medical, Inc., Lawrence, MA) membrane, blood bag containing heparinized whole blood with KCl infusion, 3/16-inch ID tubing, a peristaltic pump, and flow sensors. The NxStage permeate line was connected back to the main circuit in the Control group (n = 6), creating a recirculation loop. For KC group (n = 6), KC was added to the recirculation loop, and a continuous infusion of KCl at 10 mEq/hour was administered for two hours. Blood samples were acquired at baseline and every hour for 6 h. RESULTS: In the control group, K+ levels remained at ∼9 mmol/L; 9.1 ± 0.4 mmol/L at 6 h. In the KC group, significant decreases in K+ at hour 1 (4.3 ± 0.3 mmol/L) and were sustained for the experiment duration equilibrating at 4.6 ± 0.4 mmol/L after 6 h (p = 0.042). Main loop blood flow was maintained under 400 mL/min; recirculation loop flow varied between 60 and 70 mL/min in the control group and 45-55 mL/min in the KC group. Decreases in recirculation loop flow in KC group required 7% increase of pump RPM. CONCLUSIONS: During ex-vivo extracorporeal circulation using donor swine blood, KC removed approximately 50% of K+, normalizing circulating levels.

7.
Laryngoscope Investig Otolaryngol ; 7(4): 1057-1064, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36000036

RESUMO

Objectives/hypothesis: Composite vocal fold (VF) biomechanical data are lacking for augmentation after recurrent laryngeal nerve (RLN) injury. We hypothesize resulting atrophy decreases VF stiffness and augmentation restores native VF biomechanics. Methods: Sixteen Yorkshire Crossbreed swine underwent left RLN transection and were observed or underwent carboxymethylcellulose (CMC) or calcium hydroxyapatite (CaHa) augmentation at 2 weeks. Biomechanical measurements (structural stiffness, displacement, and maximum load) were measured at 4 or 12 weeks. Thyroarytenoid (TA) muscle cross-sectional area was quantified and compared with two-way ANOVA with Tukey's post hoc test. Results: After 4 weeks, right greater than left structural stiffness (mean ± SE) was observed (49.6 ± 0.003 vs. 28.4 ± 0.002 mN/mm), left greater than right displacement at 6.3 mN (0.54 ± 0.01 vs. 0.46 ± 0.01 mm, p < .01) was identified, and right greater than left maximum load (72.3 ± 0.005 vs. 40.8 ± 0.003 mN) was recorded. TA muscle atrophy in the injured group without augmentations was significant compared to the noninjured side, and muscle atrophy was seen at overall muscle area and individual muscle bundles. CMC augmentation appears to maintain TA muscle structure in the first 4 weeks with atrophy present at 12 weeks. Conclusions: VF biomechanical properties match TA muscle atrophy in this model, and both CMC and CaHa injection demonstrated improved biomechanical properties and slower TA atrophy compared to the uninjured side. Taken together, these data provide a quantifiable biomechanical basis for early injection laryngoplasty to improve dysphonia and potentially improve healing in reversible unilateral vocal fold atrophy. Level of evidence: N/A.

8.
Bone Res ; 10(1): 49, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35851577

RESUMO

Physical mechanical stimulation can maintain and even increase bone mass. Here, we report an important role of osteocytic integrin α5 in regulating the anabolic response of bone to mechanical loading using an Itga5 conditional gene knockout (cKO) mouse model. Integrin α5 gene deletion increased apoptotic osteocytes and reduced cortical anabolic responses to tibial compression including decreased endosteal osteoblasts and bone formation, and increased endosteal osteoclasts and bone resorption, contributing to the decreased bone area fraction and biomechanical properties, leading to an enlarged bone marrow area in cKO mice. Similar disruption of anabolic responses to mechanical loading was also detected in cKO trabecular bone. Moreover, integrin α5 deficiency impeded load-induced Cx43 hemichannel opening, and production and release of PGE2, an anabolic factor, resulting in attenuated effects of the loading on catabolic sclerostin (SOST) reduction and anabolic ß-catenin increase. Together, this study shows an indispensable role of integrin α5 in osteocytes in the anabolic action of mechanical loading on skeletal tissue through activation of hemichannels and PGE2-evoked gene expression. Integrin α5 could act as a potential new therapeutic target for bone loss, especially in the elderly population with impeded mechanical sensitivity.

9.
Tissue Eng Part C Methods ; 28(7): 363-374, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35615881

RESUMO

Regenerating large bone defects requires a multifaceted approach combining optimal scaffold designs with appropriate growth factor delivery. Supraphysiological doses of recombinant human bone morphogenetic protein 2 (rhBMP2), typically used for the regeneration of large bone defects clinically in conjunction with an acellular collagen sponge (ACS), have resulted in many complications. In this study, we develop a hydroxyapatite/collagen I (HA/Col) scaffold to improve the mechanical properties of the HA scaffolds, while maintaining open connected porosity. Varying rhBMP2 dosages were then delivered from a collagenous periosteal membrane and paired with HA or HA/Col scaffolds to treat critical-sized (15 mm) diaphyseal radial defect in New Zealand white rabbits. The groups examined were ACS +76 µg rhBMP2 (clinically used INFUSE dosage), HA +76 µg rhBMP2, HA +15 µg rhBMP2, HA/Col +15 µg rhBMP2, and HA/Col +15 µg rhBMP2 + bone marrow-derived stromal cells (bMSCs). After 8 weeks of implantation, all regenerated bones were evaluated using microcomputed tomography, histology, histomorphometry, and torsional testing. It was observed that the bone volume regenerated in the HA/Col +15 µg rhBMP2 group was significantly higher than that in the groups with 76 µg rhBMP2. The same scaffold and growth factor combination resulted in the highest bone mineral density of the regenerated bone, and the most bone apposition on the scaffold surface. Both the HA and HA/Col scaffolds paired with 15 µg rhBMP2 had sustained ingrowth of the mineralization front after 2 weeks compared to the groups with 76 µg rhBMP2, which had far greater mineralization in the first 2 weeks after implantation. Complete bridging of the defect site and no significant difference in torsional strength, stiffness, or angle at failure were observed across all groups. No benefit of additional bMSC seeding was observed on any of the quantified metrics, while bone-implant apposition was reduced in the cell-seeded group. This study demonstrated that the controlled spatial delivery of rhBMP2 at the periosteum at significantly lower doses can be used as a strategy to improve bone regeneration around space maintaining scaffolds. Tweet Inside-out or outside-in: growth factors delivered from the outside of porous mineral-collagen scaffolds, maintain strength and regrow bone better in a rabbit study. Twitter handle for senior author (@Guda_Lab) and sponsoring institution (@UTSA) Impact Statement This study provides insights on bone regeneration in the presence of spatially controlled delivery of recombinant human bone morphogenetic protein 2 (rhBMP2) from porous hydroxyapatite scaffolds coated with collagen I films. Using critical-sized defects created in the radial diaphysis of skeletally mature New Zealand White rabbits, microcomputed tomography and histomorphometry indicated significantly higher bone regeneration, bone mineral density, and bone-implant contact, as well as sustained regeneration over longer durations with lower dosage of rhBMP2 delivered periosteally.


Assuntos
Proteína Morfogenética Óssea 2 , Durapatita , Animais , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea , Colágeno/farmacologia , Humanos , Periósteo , Coelhos , Rádio (Anatomia)/diagnóstico por imagem , Alicerces Teciduais , Microtomografia por Raio-X
10.
Elife ; 112022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35132953

RESUMO

Mechanical stimulation, such as physical exercise, is essential for bone formation and health. Here, we demonstrate the critical role of osteocytic Cx43 hemichannels in anabolic function of bone in response to mechanical loading. Two transgenic mouse models, R76W and Δ130-136, expressing dominant-negative Cx43 mutants in osteocytes were adopted. Mechanical loading of tibial bone increased cortical bone mass and mechanical properties in wild-type and gap junction-impaired R76W mice through increased PGE2, endosteal osteoblast activity, and decreased sclerostin. These anabolic responses were impeded in gap junction/hemichannel-impaired Δ130-136 mice and accompanied by increased endosteal osteoclast activity. Specific inhibition of Cx43 hemichannels by Cx43(M1) antibody suppressed PGE2 secretion and impeded loading-induced endosteal osteoblast activity, bone formation and anabolic gene expression. PGE2 administration rescued the osteogenic response to mechanical loading impeded by impaired hemichannels. Together, osteocytic Cx43 hemichannels could be a potential new therapeutic target for treating bone loss and osteoporosis.


Assuntos
Remodelação Óssea , Osso e Ossos/fisiologia , Conexina 43/metabolismo , Prostaglandinas/metabolismo , Animais , Fenômenos Biomecânicos , Conexina 43/genética , Dinoprostona/metabolismo , Junções Comunicantes/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Mutação , Osteócitos/metabolismo , Estresse Mecânico , Suporte de Carga
11.
J Mater Sci Mater Med ; 32(8): 94, 2021 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-34390404

RESUMO

Beta-tricalcium phosphate (ß-TCP)-based bioinks were developed to support direct-ink 3D printing-based manufacturing of macroporous scaffolds. Binding of the gelatin:ß-TCP ink compositions was optimized by adding carboxymethylcellulose (CMC) to maximize the ß-TCP content while maintaining printability. Post-sintering, the gelatin:ß-TCP:CMC inks resulted in uniform grain size, uniform shrinkage of the printed structure, and included microporosity within the ceramic. The mechanical properties of the inks improved with increasing ß-TCP content. The gelatin:ß-TCP:CMC ink (25:75 gelatin:ß-TCP and 3% CMC) optimized for mechanical strength was used to 3D print several architectures of macroporous scaffolds by varying the print nozzle tip diameter and pore spacing during the 3D printing process (compressive strength of 13.1 ± 2.51 MPa and elastic modulus of 696 ± 108 MPa was achieved). The sintered, macroporous ß-TCP scaffolds demonstrated both high porosity and pore size but retained mechanical strength and stiffness compared to macroporous, calcium phosphate ceramic scaffolds manufactured using alternative methods. The high interconnected porosity (45-60%) and fluid conductance (between 1.04 ×10-9 and 2.27 × 10-9 m4s/kg) of the ß-TCP scaffolds tested, and the ability to finely tune the architecture using 3D printing, resulted in the development of novel bioink formulations and made available a versatile manufacturing process with broad applicability in producing substrates suitable for biomedical applications.


Assuntos
Fosfatos de Cálcio/química , Impressão Tridimensional , Alicerces Teciduais/química , Regeneração Óssea , Substitutos Ósseos/química , Carboximetilcelulose Sódica/química , Proliferação de Células , Cerâmica/química , Força Compressiva , Humanos , Teste de Materiais , Porosidade , Pressão , Estresse Mecânico , Engenharia Tecidual/métodos , Dente/fisiologia , Difração de Raios X
12.
Front Chem ; 9: 599631, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33614599

RESUMO

Electrical stimulus-responsive drug delivery from conducting polymers such as polypyrrole (PPy) has been limited by lack of versatile polymerization techniques and limitations in drug-loading strategies. In the present study, we report an in-situ chemical polymerization technique for incorporation of biotin, as the doping agent, to establish electrosensitive drug release from PPy-coated substrates. Aligned electrospun polyvinylidene fluoride (PVDF) fibers were used as a substrate for the PPy-coating and basic fibroblast growth factor and nerve growth factor were the model growth factors demonstrated for potential applications in musculoskeletal tissue regeneration. It was observed that 18-h of continuous polymerization produced an optimal coating of PPy on the surface of the PVDF electrospun fibers with significantly increased hydrophilicity and no substantial changes observed in fiber orientation or individual fiber thickness. This PPy-PVDF system was used as the platform for loading the aforementioned growth factors, using streptavidin as the drug-complex carrier. The release profile of incorporated biotinylated growth factors exhibited electrosensitive release behavior while the PPy-PVDF complex proved stable for a period of 14 days and suitable as a stimulus responsive drug delivery depot. Critically, the growth factors retained bioactivity after release. In conclusion, the present study established a systematic methodology to prepare PPy coated systems with electrosensitive drug release capabilities which can potentially be used to encourage targeted tissue regeneration and other biomedical applications.

13.
Tissue Eng Part A ; 27(9-10): 549-560, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32878567

RESUMO

Skeletal muscle is a tissue that is directly involved in the progression and persistence of type 2 diabetes (T2D), a disease that is becoming increasingly common. Gaining better insight into the mechanisms that are affecting skeletal muscle dysfunction in the context of T2D has the potential to lead to novel treatments for a large number of patients. Through its ability to emulate skeletal muscle architecture while also incorporating aspects of disease, tissue-engineered skeletal muscle (TE-SkM) has the potential to provide a means for rapid high-throughput discovery of therapies to treat skeletal muscle dysfunction, to include that which occurs with T2D. Muscle precursor cells isolated from lean or obese male Zucker diabetic fatty rats were used to generate TE-SkM constructs. Some constructs were treated with adipogenic induction media to accentuate the presence of adipocytes that is a characteristic feature of T2D skeletal muscle. The maturity (compaction and creatine kinase activity), mechanical integrity (Young's modulus), organization (myotube orientation), and metabolic capacity (insulin-stimulated glucose uptake) were all reduced by diabetes. Treating constructs with adipogenic induction media increased the quantity of lipid within the diabetic TE-SkM constructs, and caused changes in construct compaction, cell orientation, and insulin-stimulated glucose uptake in both lean and diabetic samples. Collectively, the findings herein suggest that the recapitulation of structural and metabolic aspects of T2D can be accomplished by engineering skeletal muscle in vitro.


Assuntos
Diabetes Mellitus Tipo 2 , Animais , Humanos , Insulina , Masculino , Fibras Musculares Esqueléticas , Músculo Esquelético , Ratos , Ratos Zucker
14.
J Biomed Mater Res B Appl Biomater ; 109(4): 538-547, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32915522

RESUMO

Extracellular matrix (ECM) products have the potential to improve cellular attachment and promote tissue-specific development by mimicking the native cellular niche. In this study, the therapeutic efficacy of an ECM substratum produced by bone marrow stem cells (BM-MSCs) to promote bone regeneration in vitro and in vivo were evaluated. Fluorescence-activated cell sorting analysis and phenotypic expression were employed to characterize the in vitro BM-MSC response to bone marrow specific ECM (BM-ECM). BM-ECM encouraged cell proliferation and stemness maintenance. The efficacy of BM-ECM as an adjuvant in promoting bone regeneration was evaluated in an orthotopic, segmental critical-sized bone defect in the rat femur over 8 weeks. The groups evaluated were either untreated (negative control); packed with calcium phosphate granules or granules+BM-ECM free protein and stabilized by collagenous membrane. Bone regeneration in vivo was analyzed using microcomputed tomography and histology. in vivo results demonstrated improvements in mineralization, osteogenesis, and tissue infiltration (114 ± 15% increase) in the BM-ECM complex group from 4 to 8 weeks compared to mineral granules only (45 ± 21% increase). Histological observations suggested direct apposition of early bone after 4 weeks and mineral consolidation after 8 weeks implantation for the group supplemented with BM-ECM. Significant osteoid formation and greater functional bone formation (polar moment of inertia was 71 ± 0.2 mm4 with BM-ECM supplementation compared to 48 ± 0.2 mm4 in untreated defects) validated in vivo indicated support of osteoconductivity and increased defect site cellularity. In conclusion, these results suggest that BM-ECM free protein is potentially a therapeutic supplement for stemness maintenance and sustaining osteogenesis.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Proteínas da Matriz Extracelular/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Animais , Regeneração Óssea/fisiologia , Calcificação Fisiológica/efeitos dos fármacos , Fosfatos de Cálcio/farmacologia , Colágeno/uso terapêutico , Fêmur/diagnóstico por imagem , Fêmur/lesões , Fêmur/fisiologia , Técnicas In Vitro , Teste de Materiais , Especificidade de Órgãos , Osteogênese/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Microtomografia por Raio-X
15.
Tissue Eng Part A ; 27(13-14): 940-961, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32924856

RESUMO

Vascularization is critical for engineering mineralized tissues. It has been previously shown that biomaterials containing preformed endothelial networks anastomose to host vasculature following implantation. However, the networks alone may not increase regeneration. In addition, a clinically applicable source of cells for vascularization is needed. In this study, vascular networks were generated from endothelial cells (ECs) derived from human induced pluripotent stem cells (iPSCs). Network formation by iPSC-ECs within fibrin gels was investigated in a mesenchymal stem cells (MSCs) coculture spheroid model. Statistical design of experiments technique was evaluated for its predicting capability during the optimization of experimental parameters. The prevascularized units were combined with hydroxyapatite nanoparticles to develop a vascularized composite hydrogel that was implanted in a rodent critical-sized cranial defect model. Immunohistological staining for human-specific CD31 at week 1 indicated the presence and maintenance of the implanted vessels. At 8 weeks, the prevascularized systems resulted in higher vessel density over MSC-only scaffolds. The implanted vessels appeared to establish flow with host vasculature. While there was a slight increase in bone volume in the prevascularized bone construct compared to MSC-only bone constructs, there was not a profound increase in bone regeneration. These results show that scaffolds with network structures can be generated from ECs derived from iPSC and that the networks survive and inosculate with the host postimplantation in a bone model. Impact statement Vascularization is critical for engineering bone. Prevascularized scaffolds have been shown to improve postimplantation vascularization. Herein, vascularized networks were generated from induced pluripotent cells derived from endothelial cells. These vascularized units were combined with a fibrin/hydroxyapatite scaffold to develop a prevascularized construct for bone regeneration. Implantation of these scaffolds in a small animal cranial defect model resulted in network inosculation and increased vascularization, but exhibited only a limited effect on bone formation. This study provides insight into the challenges of generating vascularized bone.


Assuntos
Células-Tronco Pluripotentes Induzidas , Animais , Regeneração Óssea , Células Endoteliais , Humanos , Neovascularização Fisiológica , Osteogênese , Engenharia Tecidual , Alicerces Teciduais
16.
Laryngoscope ; 131(9): 1958-1966, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33125169

RESUMO

OBJECTIVES/HYPOTHESIS: Novel laryngotracheal wound coverage devices are limited by complex anatomy, smooth surfaces, and dynamic pressure changes and airflow during breathing. We hypothesize that a bioinspired mucoadhesive patch mimicking how geckos climb smooth surfaces will permit sutureless wound coverage and also allow drug delivery. STUDY DESIGN: ex-vivo. METHODS: Polycaprolactone (PCL) fibers were electrospun onto a substrate and polyethylene glycol (PEG) - acrylate flocks in varying densities were deposited to create a composite patch. Sample topography was assessed with laser profilometry, material stiffness with biaxial mechanical testing, and mucoadhesive testing determined cohesive material failure on porcine tracheal tissue. Degradation rate was measured over 21 days in vitro along with dexamethasone drug release profiles. Material handleability was evaluated via suture retention and in cadaveric larynges. RESULTS: Increased flocking density was inversely related to cohesive failure in mucoadhesive testing, with a flocking density of PCL-PEG-2XFLK increasing failure strength to 6880 ± 1810 Pa compared to 3028 ± 791 in PCL-PEG-4XFLK density and 1182 ± 262 in PCL-PEG-6XFLK density. The PCL-PEG-2XFLK specimens had a higher failure strength than PCL alone (1404 ± 545 Pa) or PCL-PEG (2732 ± 840). Flocking progressively reduced composite stiffness from 1347 ± 15 to 763 ± 21 N/m. Degradation increased from 12% at 7 days to 16% after 10 days and 20% after 21 days. Cumulative dexamethasone release at 0.4 mg/cm2 concentration was maintained over 21 days. Optimized PCL-PEG-2XFLK density flocked patches were easy to maneuver endoscopically in laryngeal evaluation. CONCLUSIONS: This novel, sutureless, patch is a mucoadhesive platform suitable to laryngeal and tracheal anatomy with drug delivery capability. LEVEL OF EVIDENCE: NA Laryngoscope, 131:1958-1966, 2021.


Assuntos
Dexametasona/administração & dosagem , Glucocorticoides/administração & dosagem , Técnicas de Fechamento de Ferimentos/instrumentação , Cicatrização/efeitos dos fármacos , Animais , Materiais Biocompatíveis , Cadáver , Dexametasona/uso terapêutico , Sistemas de Liberação de Medicamentos/tendências , Avaliação Pré-Clínica de Medicamentos , Glucocorticoides/uso terapêutico , Humanos , Laringe/anatomia & histologia , Laringe/patologia , Preparações Farmacêuticas/administração & dosagem , Poliésteres/química , Polietilenoglicóis/química , Procedimentos Cirúrgicos sem Sutura/métodos , Suínos , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Traqueia/anatomia & histologia , Traqueia/patologia , Cicatrização/fisiologia
17.
Cell Mol Bioeng ; 13(5): 507-526, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33184580

RESUMO

BACKGROUND: Volumetric tissue-engineered constructs are limited in development due to the dependence on well-formed vascular networks. Scaffold pore size and the mechanical properties of the matrix dictates cell attachment, proliferation and successive tissue morphogenesis. We hypothesize scaffold pore architecture also controls stromal-vessel interactions during morphogenesis. METHODS: The interaction between mesenchymal stem cells (MSCs) seeded on hydroxyapatite scaffolds of 450, 340, and 250 µm pores and microvascular fragments (MVFs) seeded within 20 mg/mL fibrin hydrogels that were cast into the cell-seeded scaffolds, was assessed in vitro over 21 days and compared to the fibrin hydrogels without scaffold but containing both MSCs and MVFs. mRNA sequencing was performed across all groups and a computational mechanics model was developed to validate architecture effects on predicting vascularization driven by stiffer matrix behavior at scaffold surfaces compared to the pore interior. RESULTS: Lectin staining of decalcified scaffolds showed continued vessel growth, branching and network formation at 14 days. The fibrin gel provides no resistance to spread-out capillary networks formation, with greater vessel loops within the 450 µm pores and vessels bridging across 250 µm pores. Vessel growth in the scaffolds was observed to be stimulated by hypoxia and successive angiogenic signaling. Fibrin gels showed linear fold increase in VEGF expression and no change in BMP2. Within scaffolds, there was multiple fold increase in VEGF between days 7 and 14 and early multiple fold increases in BMP2 between days 3 and 7, relative to fibrin. There was evidence of yap/taz based hippo signaling and mechanotransduction in the scaffold groups. The vessel growth models determined by computational modeling matched the trends observed experimentally. CONCLUSION: The differing nature of hypoxia signaling between scaffold systems and mechano-transduction sensing matrix mechanics were primarily responsible for differences in osteogenic cell and microvessel growth. The computational model implicated scaffold architecture in dictating branching morphology and strain in the hydrogel within pores in dictating vessel lengths.

18.
Int J Oral Maxillofac Implants ; 35(1): 39-51, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31923288

RESUMO

PURPOSE: This study evaluated a novel injectable, self-setting, osteoconductive, resorbable adhesive that provides immediate implant stabilization. MATERIALS AND METHODS: Twenty-six large canines had the mandibular second through fourth premolars and the first molar removed bilaterally. After 3 months, oversized osteotomies were prepared with only the apical 2 mm of the implant engaging native bone. One site had a novel resorbable, self-setting, mineral-organic adhesive (TN-SM) placed around the implant, a second site received bone graft, and a third site received only blood clot. Removal torque, standardized radiography, and histology were used to evaluate implant stability and tissue contact after 24 hours, 10 days, and 4 months. RESULTS: Mean removal torque values after 24 hours were 1.4, 1.3, and 22.2 Ncm for the control, bone graft, and mineral-organic adhesive, respectively. After 10 days, these values were 5.7, 6.2, and 45.7 Ncm and at 4 months increased to 88.7, 77.8, and 104.7 Ncm, respectively. Clinical, radiographic, and histologic evaluations showed a lack of inflammatory reaction. Control defects were initially radiolucent in the coronal area; grafted sites revealed particles in the gap, with both conditions gradually filling with bone over time. At 10 days, histologic evaluation demonstrated excellent biocompatibility and intimate contact of mineral-organic adhesive to both the implant and bone, providing an osseointegration-like bond; control sites revealed no bone contact in the defect area, while the bone-grafted sites revealed unattached graft particles. At 4 months, much of the mineral-organic adhesive was replaced with bone; the control and grafted sites had some bone fill, and many of the defects demonstrated no bone-to-implant contact and were filled with soft tissue or isolated graft particles. CONCLUSION: The mineral-organic adhesive provides immediate (osseointegration-like) and continued implant stabilization over 4 months in sites lacking primary stability. Experimental sites demonstrated maintenance of crestal bone levels adjacent to the mineral-organic adhesive and soft tissue exclusion without the use of membranes in this canine model. These results demonstrate that this novel mineral-organic adhesive can enable implant osseointegration in a site where insufficient native bone exists to allow immediate implant placement.


Assuntos
Implantes Dentários , Cimentos Dentários , Implantação Dentária Endóssea , Mandíbula , Minerais , Osseointegração
19.
J Biomed Mater Res B Appl Biomater ; 108(3): 1157-1166, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31410993

RESUMO

Critically sized bone defects are often compounded by infectious complications. The standard of care consists of bone autografts with systemic antibiotics. These injuries and treatments lead to donor site morbidity, antibiotic resistant strains of bacteria, and often end stage amputation. This study proposes an alternative to the autograft using a porous, hydroxyapatite (HA) scaffold evaluated with and without infection and antibiotics. Twenty-four New Zealand white rabbits received either our HA scaffold or a pulverized autograft (PBA) within a surgically created critical-sized defect in the femur. The two grafts were evaluated in either septic or aseptic defects and with or without antibiotic treatment. The HA scaffolds were characterized with micro computed tomography. Post-euthanasia, micro computed tomography, histology, and white blood cells component analysis were completed. The HA had significantly greater (p < .001) mineralization to total volume than the PBA groups with 27.56% and 14.88%, respectively, and the septic HA groups were significantly greater than the aseptic groups both with and without antibiotics (p = .016). The bone quality denoted by bone mineral density was also significantly greater (p < .001) in the HA groups (67.01 ± 0.38 mgHA/cm3 ) than the PBA groups (64.66 ± 0.85 mgHA/cm3 ). The HA scaffold is a viable alternative to the bone autograft in defects with and without infection as shown by the quality and quantity of bone.


Assuntos
Osso e Ossos/patologia , Durapatita/química , Animais , Autoenxertos , Densidade Óssea , Regeneração Óssea , Transplante Ósseo , Farmacorresistência Bacteriana , Feminino , Fêmur , Osteomielite/tratamento farmacológico , Porosidade , Coelhos , Regeneração , Engenharia Tecidual/métodos , Alicerces Teciduais , Cicatrização , Microtomografia por Raio-X
20.
Laryngoscope ; 130(2): 454-459, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31059589

RESUMO

OBJECTIVES: Development of novel vocal fold (VF) therapeutics is limited by a lack of standardized, meaningful outcomes. We hypothesize that automated microindentation-based VF biomechanical property mapping matched to histology permits quantitative assessment. STUDY DESIGN: Ex vivo. METHODS: Twelve anesthetized New Zealand white rabbits underwent endoscopic right VF injury. Larynges were harvested/bisected day 7, 30, or 60 (n = 4/group), with four uninjured controls. Biomechanical measurements (normal force, structural stiffness, and displacement at 1.96 mN) were calculated using automated microindentation mapping (0.3 mm depth, 1.2 mm/s, 2 mm spherical indenter) with a grid overlay (>50 locations weighted toward VF edge, separated into 14 zones). Specimens were marked/fixed/sectioned, and slides matched to measurement points. RESULTS: In the injury zone, normal force/structural stiffness (mean, standard deviation [SD]/mean, SD) increased from uninjured (2.2 mN, 0.64/7.4 mN/mm, 2.14) and day 7 (2.7 mN, 0.75/9.0 mN/mm, 2.49) to day 30 (4.3 mN, 2.11/14.2 mN/mm, 7.05) and decreased at 60 days (2.7 mN, 0.77/9.1 mN/mm, 2.58). VF displacement decreased from control (0.28 mm, 0.05) and day 7 (0.26 mm, 0.05) to day 30 (0.20 mm, 0.05), increasing at day 60 (0.25 mm, 0.06). A one-way ANOVA was significant; Tukey's post hoc test confirmed day-30 samples differed from other groups (P < 0.05), consistent across adjacent zones. Zones far from injury remained similar across groups (P = 0.143 to 0.551). These measurements matched qualitative histologic variations. CONCLUSION: Quantifiable VF biomechanical properties can be linked to histology. This technological approach is the first to simultaneously correlate functional biomechanics with histology and is ideal for future preclinical studies. LEVEL OF EVIDENCE: NA Laryngoscope, 130:454-459, 2020.


Assuntos
Prega Vocal/lesões , Cicatrização/fisiologia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Laringoscopia , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA