Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cancer ; 18(1): 204, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29463222

RESUMO

BACKGROUND: The assessment of circulating tumor cells (CTCs) has been shown to enable monitoring of treatment response and early detection of metastatic breast cancer (MBC) recurrence. The aim of this study was to compare a well-established CTC detection method based on immunomagnetic isolation with a new, filtration-based platform. METHODS: In this prospective study, two 7.5 ml blood draws were obtained from 60 MBC patients and CTC enumeration was assessed using both the CellSearch® and the newly developed filtration-based platform. We analyzed the correlation of CTC-positivity between both methods and their ability to predict prognosis. Overall survival (OS) was calculated and Kaplan-Meier curves were estimated with thresholds of ≥1 and ≥5 detected CTCs. RESULTS: The CTC positivity rate of the CellSearch® system was 56.7% and of the filtration-based platform 66.7%. There was a high correlation of CTC enumeration obtained with both methods. The OS for patients without detected CTCs, regardless of the method used, was significantly higher compared to patients with one or more CTCs (p < 0.001). The median OS of patients with no CTCs vs. ≥ 1 CTC assessed by CellSearch® was 1.83 years (95% CI: 1.63-2.02) vs. 0.74 years (95% CI: 0.51-1.52). If CTCs were detected by the filtration-based method the median OS times were 1.88 years (95% CI: 1.74-2.03) vs. 0.59 years (95% CI: 0.38-0.80). CONCLUSIONS: The newly established EpCAM independently filtration-based system is a suitable method to determine CTC counts for MBC patients. Our study confirms CTCs as being strong predictors of prognosis in our population of MBC patients.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/mortalidade , Filtração/métodos , Citometria de Fluxo , Células Neoplásicas Circulantes/patologia , Idoso , Biomarcadores Tumorais , Neoplasias da Mama/metabolismo , Molécula de Adesão da Célula Epitelial/metabolismo , Feminino , Imunofluorescência , Humanos , Separação Imunomagnética , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Células Neoplásicas Circulantes/metabolismo , Modelos de Riscos Proporcionais , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
J Microbiol Methods ; 131: 105-109, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27765617

RESUMO

Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200µL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques.


Assuntos
Patógenos Transmitidos pelo Sangue/isolamento & purificação , Sangue/microbiologia , Técnicas Microbiológicas/métodos , Patologia Molecular/métodos , Sepse/diagnóstico , Sepse/microbiologia , Bactérias/classificação , Bactérias/genética , Bactérias/isolamento & purificação , Bactérias/patogenicidade , Candida tropicalis/genética , Candida tropicalis/isolamento & purificação , Células Cultivadas , Contagem de Colônia Microbiana/métodos , DNA Bacteriano/sangue , DNA Fúngico/sangue , Enterococcus/genética , Enterococcus/isolamento & purificação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Fungos/classificação , Fungos/genética , Fungos/isolamento & purificação , Fungos/patogenicidade , Genoma Humano , Humanos , Limite de Detecção , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Sepse/sangue , Fatores de Tempo , beta 2-Glicoproteína I/administração & dosagem
3.
Anal Chem ; 87(24): 12104-11, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26574152

RESUMO

MicroRNAs are auspicious candidates for a new generation of biomarkers. The detection of microRNA panels in body fluids promises early diagnosis of many diseases, including cancer or acute coronary syndrome. For a fast, sensitive, and specific detection of microRNA panels on the bedside, medical point-of-care systems that measure those biomarkers are required. As microchips are promising technical tools for a robust signal measurement at biochemical interfaces, we developed an assay for the electrochemical multiplex quantification of microRNAs on a CMOS chip with interdigitated gold electrode sensor positions. The method is based on the formation of a tripartite hybridization complex and subsequent both-sided ligation of the target nucleic acid to a reporter and capture strand. With a time to results of 30 min, the reported assay achieves a limit of detection below 1 pM, at a specificity down to single mismatch discrimination. It also offers very good signal dynamics between 1 pM and 1 nM, thus, allowing reliable quantification of the detected microRNAs and easy implementation into automated devices due to a simple workflow.


Assuntos
Técnicas Genéticas , MicroRNAs/análise , Limite de Detecção , MicroRNAs/genética , Técnicas de Diagnóstico Molecular , Fatores de Tempo
4.
Clin Chem ; 61(4): 600-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25617425

RESUMO

BACKGROUND: The implementation of new biomarkers into clinical practice is one of the most important areas in medical research. Besides their clinical impact, novel in vitro diagnostic markers promise to have a substantial effect on healthcare costs. Although numerous publications report the discovery of biomarkers, only a fraction of those markers are routinely used. One key challenge is a measurement system that is compatible with clinical workflows. METHODS: We designed a new immunoassay for microRNA (miRNA) quantification. The assay combines streptavidin-linked microparticles, a biotinylated catcher oligonucleotide complementary to a single miRNA species, and finally, a monoclonal antibody to DNA/RNA heterohybrids labeled with acridinium ester. Importantly, our assay runs on standard immunoassay analyzers. After a technical validation of the assay, we evaluated the clinical performance on 4 Alzheimer disease miRNAs. RESULTS: Our assay has an analytical specificity of 99.4% and is at the same time sensitive (concentrations in the range of 1 pmol/L miRNA can be reliably profiled). Because the novel approach did not require amplification steps, we obtained high reproducibility for up to 40 biological replicates. Importantly, our assay prototype exhibited a time to result of <3 h. With human blood samples, the assay was able to measure 4 miRNAs that can detect Alzheimer disease with a diagnostic accuracy of 82% and showed a Pearson correlation >0.994 with the gold standard qRT-PCR. CONCLUSIONS: Our miRNA immunoassay allowed the measurement of miRNA signatures with sufficient analytical sensitivity and high specificity on commonly available laboratory equipment.


Assuntos
Doença de Alzheimer/genética , Anticorpos Monoclonais , Biomarcadores/sangue , Imunoensaio/métodos , MicroRNAs/sangue , Doença de Alzheimer/sangue , Humanos , Imunoensaio/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Biosens Bioelectron ; 22(8): 1798-806, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17046234

RESUMO

A thermostable, single polypeptide chain enzyme, esterase 2 from Alicyclobacillus acidocaldarius, was covalently conjugated in a site specific manner with an oligodeoxynucleotide. The conjugate served as a reporter enzyme for electrochemical detection of DNA hybridization. Capture oligodeoxynucleotides were assembled on gold electrode via thiol-gold interaction. The esterase 2-oligodeoxynucleotide conjugates were brought to electrode surface by DNA hybridization. The p-aminophenol formed by esterase 2 catalyzed hydrolysis of p-aminophenylbutyrate was amperometrically determined. Esterase 2 reporters allows to detect approximately 1.5 x 10(-18)mol oligodeoxynucleotides/0.6 mm2 electrode, or 3 pM oligodeoxynucleotide in a volume of 0.5 microL. Chemically targeted, single site covalent attachment of esterase 2 to an oligodeoxynucleotide significantly increases the selectivity of the mismatch detection as compared to widely used, rather unspecific, streptavidin/biotin conjugated proteins. Artificial single nucleotide mismatches in a 510-nucleotide ssDNA could be reliably determined using esterase 2-oligodeoxynucleotide conjugates as a reporter.


Assuntos
Eletroquímica/métodos , Esterases/metabolismo , Hibridização de Ácido Nucleico/métodos , Oligodesoxirribonucleotídeos/metabolismo , Pareamento Incorreto de Bases , Biotina , DNA/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA