Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Acta Biomater ; 128: 384-392, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33945880

RESUMO

In cases of aortic stenosis, bioprosthetic heart valves (BHVs), with glutaraldehyde-fixed bovine pericardium leaflets (GLBP), are often implanted to replace the native diseased valve. Widespread use of BHVs, however, is restricted due to inadequate long-term durability, owing specifically to premature leaflet failure. Mechanical fatigue damage and calcification remain the primary leaflet failure modes, where glutaraldehyde treatment is known to accelerate calcification. The literature in this area is limited, with some studies suggesting mechanical damage increases calcification and others that they are independent degenerative mechanisms. In this study, specimens which were non-destructively pre-sorted according to collagen fibre architecture and uniaxially cyclically loaded until failure or 1 million cycles, were placed in an in vitro calcification solution. The weakest specimen group (those with fibres aligned perpendicular to the load) had statistically significantly higher volumes of calcification when compared to those with a high fatigue life. Moreover, SEM imaging revealed that ruptured and damaged fibres presented calcium binding sites; resulting in 4 times more calcification in fractured samples in comparison to those which did not fail by fatigue. To the authors' knowledge, this study quantifies for the first time, that mechanical damage drives calcification in commercial-grade GLBP and that calcification varies spatially according to localised damage levels. These findings illustrate that not only is calcification of GLBP exacerbated by fatigue damage, but that both failure phenomena are underpinned by the collagen fibre organisation. Consequently, controlling for GLBP collagen fibre architecture in leaflets could minimise the progression of these primary failure modes in patient BHVs. STATEMENT OF SIGNIFICANCE: Mechanical damage and calcification are the primary premature failure modes of glutaraldehyde-fixed bovine pericardial (GLBP) leaflets in bioprosthetic heart valves. In this study, commercial-grade GLBP specimens which were uniaxially cyclically loaded to failure or 1 million cycles, were placed in an in vitro calcification solution. MicroCT and SEM analysis showed that localised calcification levels varied spatially according to damage, where ruptured fibres offered additional calcium binding sites. Furthermore, specimens with a statistically significant lower fatigue life were associated with statistically significant higher calcification. This study revealed that mechanical damage drives calcification of GLBP. Non-destructive pre-screening of collagen fibres demonstrated that both the fatigue life and calcification potential of commercial-grade GLBP, are underpinned by the collagen fibre architecture.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Bioprótese/efeitos adversos , Bovinos , Colágeno , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas , Humanos , Pericárdio
2.
Ann Biomed Eng ; 49(3): 1022-1032, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33063231

RESUMO

Bioprosthetic heart valves (BHVs) are implanted in aortic valve stenosis patients to replace the native, dysfunctional valve. Yet, the long-term performance of the glutaraldehyde-fixed bovine pericardium (GLBP) leaflets is known to reduce device durability. The aim of this study was to investigate a type of commercial-grade GLBP which has been over-looked in the literature to date; that of high collagen fibre dispersion (HD). Under uniaxial cyclic loading conditions, it was observed that the fatigue behaviour of HD GLBP was substantially equivalent to GLBP in which the fibres are highly aligned along the loading direction. It was also found that HD GLBP had a statistically significant 9.5% higher collagen content when compared to GLBP with highly aligned collagen fibres. The variability in diseased BHV delivery sites results in unpredictable and complex loading patterns across leaflets in vivo. This study presents the possibility of a shift from the traditional choice of circumferentially aligned GLBP leaflets, to that of high fibre dispersion arrangements. Characterised by its high fatigue life and increased collagen content, in addition to multiple fibre orientations, GLBP of high fibre dispersion may provide better patient outcomes under the multi-directional loading to which BHV leaflets are subjected in vivo.


Assuntos
Próteses Valvulares Cardíacas , Pericárdio , Animais , Bovinos , Colágeno , Fixadores , Glutaral , Pericárdio/diagnóstico por imagem , Falha de Prótese , Estresse Mecânico
3.
J Wound Care ; 28(9): 639-640, 2019 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-31513495

Assuntos
Bandagens , Biofilmes
4.
Biomech Model Mechanobiol ; 18(1): 79-88, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30128675

RESUMO

It has been proposed that inappropriate positioning of transcatheter aortic valves (TAVs) is associated with procedural complications and decreased device durability. Second-generation TAVs allow for repositioning giving greater control over the final deployment position. However, the impact of positioning on the tissue surrounding these devices needs to be better understood, in particular for the interleaflet triangle in which the conductance system (bundle of His) resides. In this study, we investigate the impact of implantation depth on the frame-tissue interaction for a next-generation repositionable Lotus™ valve. For this purpose, a computational model simulating deployment of the Lotus valve frame into a calcified patient-specific aortic root geometry was generated to predict aortic root stress and frame eccentricity at three different deployment depths. The results of this study predicted that positioning of the Lotus valve had an influence on the stresses in the aortic sinus and frame eccentricity. An analysis of levels of stress arising in the vicinity of the bundle of His, as a function of implantation depth, was conducted, and it was found that, for the specific patient anatomy studied, although the sub-annular position showed reduced peak stress in the aortic sinus, this implantation position showed the highest stress in the area of greatest risks of conductance interference. In contrast, while a supra-annular position increased the peak arterial stress, this implantation position resulted in lower stress in the interleaflet triangle and thus might reduce the risk of conductance interference. These results provide pre-operative information that can inform clinical decision-making regarding TAVI positioning.


Assuntos
Fascículo Atrioventricular/cirurgia , Estresse Mecânico , Substituição da Valva Aórtica Transcateter , Valva Aórtica/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Seio Coronário/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Modelos Cardiovasculares
5.
Anal Bioanal Chem ; 411(1): 217-229, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30402675

RESUMO

Biomedical devices are complex products requiring numerous assembly steps along the industrial process chain, which can carry the potential of surface contamination. Cleanliness has to be analytically assessed with respect to ensuring safety and efficacy. Although several analytical techniques are routinely employed for such evaluation, a reliable analysis chain that guarantees metrological traceability and quantification capability is desirable. This calls for analytical tools that are cascaded in a sensible way to immediately identify and localize possible contamination, both qualitatively and quantitatively. In this systematic inter-comparative approach, we produced and characterized sodium dodecyl sulfate (SDS) films mimicking contamination on inorganic and organic substrates, with potential use as reference materials for ambient techniques, i.e., ambient mass spectrometry (AMS), infrared and Raman spectroscopy, to reliably determine amounts of contamination. Non-invasive and complementary vibrational spectroscopy techniques offer a priori chemical identification with integrated chemical imaging tools to follow the contaminant distribution, even on devices with complex geometry. AMS also provides fingerprint outputs for a fast qualitative identification of surface contaminations to be used at the end of the traceability chain due to its ablative effect on the sample. To absolutely determine the mass of SDS, the vacuum-based reference-free technique X-ray fluorescence was employed for calibration. Convex hip liners were deliberately contaminated with SDS to emulate real biomedical devices with an industrially relevant substance. Implementation of the aforementioned analytical techniques is discussed with respect to combining multimodal technical setups to decrease uncertainties that may arise if a single technique approach is adopted. Graphical abstract ᅟ.


Assuntos
Dodecilsulfato de Sódio/análise , Análise Espectral/métodos , Vácuo , Humanos , Padrões de Referência , Dodecilsulfato de Sódio/normas , Propriedades de Superfície
6.
J Pharm Biomed Anal ; 150: 308-317, 2018 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-29272815

RESUMO

There is a strong need in the medical device industry to decrease failure rates of biomedical devices by reducing the incidence of defect structures and contaminants during the production process. The detection and identification of defect structures and contaminants is crucial for many industrial applications. The present study exploits reference-free X-ray fluorescence (XRF) analysis as an analytical tool for the traceable characterization of surface contaminants of medical devices, in particular N,N'-ethylene-bis (stearamide), an ubiquitous compound used in many industrial applications as a release agent or friction reduction additive. Reference-free XRF analysis as primary method has been proven to be capable of underpinning all other applied methods since it yields the absolute mass deposition of the selected N,N'-ethylene-bis (stearamide) contaminant whilst X-ray absorption fine structure analysis determines the chemical species. Ambient vibrational spectroscopy and mass spectroscopy methodologies such as Fourier transform infrared, Raman, and secondary ion mass spectroscopy have been used in this systematic procedure providing an extensive range of complementary analyses. The calibration procedure described in this paper was developed using specially designed and fabricated model systems varying in thickness and substrate material. Furthermore, typical real medical devices such as both a polyethylene hip liner and a silver-coated wound dressing have been contaminated and investigated by these diverse methods, enabling testing of this developed procedure. These well-characterized samples may be used as calibration standards for bench top instrumentation from the perspective of providing traceable analysis of biomaterials and surface treatments. These findings demonstrate the potential importance and usefulness of combining complementary methods for a better understanding of the relevant organic materials.


Assuntos
Contaminação de Equipamentos , Equipamentos e Provisões , Espectrometria por Raios X/normas , Ácidos Esteáricos/análise , Calibragem , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massa de Íon Secundário , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman
7.
J R Soc Interface ; 12(113): 20150737, 2015 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-26674192

RESUMO

Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a 'peel-back' leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve.


Assuntos
Valvas Cardíacas , Modelos Cardiovasculares , Pericárdio , Stents , Substituição da Valva Aórtica Transcateter , Humanos
8.
Opt Express ; 23(17): 21678-89, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368147

RESUMO

We report a unidirectional frequency dissemination scheme for high-fidelity optical carriers deployable over telecommunication networks. For the first time, a 10 Gb/s Binary Phase Shift Keying (BPSK) signal from an ultra-narrow linewidth laser was transmitted through a field-installed optical fibre with round-trip length of 124 km between Cork City and town of Clonakilty, without inline optical amplification. At the receiver, using coherent communication techniques and optical injection-locking the carrier was recovered with noise suppression. The beat signal between the original carrier at the transmitter and recovered carrier at the receiver shows a linewidth of 2.8 kHz. Long term stability measurements revealed fractional instabilities (True Allan deviation) of 3.3 × 10(-14) for 1 s averaging time, prior to phase noise cancellation.

9.
Ann Biomed Eng ; 42(9): 1989-2001, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24912765

RESUMO

Self expanding Transcatheter Aortic Valve Replacements (TAVR) can conform to the geometry of the aortic annulus and the calcified leaflet complex, which may result in leaflet distortion and altered leaflet kinematics, but such changes have not yet been characterized. In this study we developed a computational model to investigate the deployment of a self expanding TAVR in a realistic aortic root model derived from multi-slice computed tomography (MSCT) images. We simulated TAVR crimping/deployment in realistic and idealized aortic root models, followed by diastolic loading of the TAVR leaflets in its final deployed configuration. The TAVR deployed in a realistic aortic root had increased peak loading in the commissural region of the leaflets compared to TAVRs under idealized circular deployment conditions (2.97 vs. 1.52 MPa). Furthermore, orientation of the TAVR in the asymmetric aortic annulus such that the commissures of the TAVR are aligned with the native valve commissures minimized the effect of TAVR stent distortion on peak stresses in the TAVR leaflets (2.97 vs. 2.35 MPa). We propose that preoperative planning of the orientation of the TAVR in the aortic root annulus might minimize the impact of potential stent distortion on leaflet function and may in turn increase long term leaflet durability.


Assuntos
Valva Aórtica/cirurgia , Análise de Elementos Finitos , Próteses Valvulares Cardíacas , Modelos Biológicos , Idoso de 80 Anos ou mais , Valva Aórtica/anatomia & histologia , Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Cateterismo Cardíaco , Simulação por Computador , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Tomografia Computadorizada Multidetectores , Stents
10.
Ann Biomed Eng ; 42(6): 1195-206, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24719050

RESUMO

Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell damage. Particle Image Velocimetry was used to quantitatively characterize fluid velocity fields, shear stress and turbulent kinetic energy downstream of TAVRs deployed in circular and eccentric orifices representative of deployed TAVRs in vivo. Effective orifice area (EOA) and mean transvalvular pressure gradient (TVG) values did not differ substantially in circular and eccentric deployed valves, with only a minor decrease in EOA observed in the eccentric valve (2.0 cm(2) for circular, 1.9 cm(2) for eccentric). Eccentric deployed TAVR lead to asymmetric systolic jet formation, with increased shear stresses (circular = 97 N/m(2) vs. eccentric = 119 N/m(2)) and regions of turbulence intensity (circular = 180 N/m(2) vs. eccentric = 230 N/m(2)) downstream that was not present in the circular deployed TAVR. The results of this study indicate that eccentric deployment of TAVRs can lead to altered flow characteristics and may potentially increase the hemolytic potential of the valve, which were not captured through hemodynamic evaluation alone.


Assuntos
Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Modelos Cardiovasculares , Fluxo Pulsátil , Humanos , Reologia
11.
Opt Express ; 22(3): 2595-602, 2014 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-24663552

RESUMO

For the first time, we demonstrate the orchestration of elastic datacenter and inter-datacenter transport network resources using a combination of OpenStack and OpenFlow. Programmatic control allows a datacenter operator to dynamically request optical lightpaths from a transport network operator to accommodate rapid changes of inter-datacenter workflows.

12.
Opt Express ; 18(24): 24745-52, 2010 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-21164822

RESUMO

In this paper we report field transmission of a 2 Tbit/s multi-banded Coherent WDM signal over BT Ireland's installed SMF, using EDFA amplification only, with mixed Ethernet (with FEC) and PRBS payloads. To the best of our knowledge, the results obtained represent the highest total capacity transmitted over installed SMF with orthogonal subcarriers. BERs below 10(-5) and no frame-loss were recorded for all 49 subcarriers. Extended BER measurements over several hours showed fluctuations that can be attributed to PMD and to dynamic effects associated with clock instabilities.

13.
Opt Express ; 18(13): 13908-14, 2010 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-20588523

RESUMO

Low-cost, high-capacity optical transmission systems are required for metropolitan area networks. Direct-detected multi-carrier systems are attractive candidates, but polarization mode dispersion (PMD) is one of the major impairments that limits their performance. In this paper, we report the first experimental analysis of the PMD tolerance of a 288Gbit/s NRZ-OOK Coherent Wavelength Division Multiplexing system. The results show that this impairment is determined primarily by the subcarrier baud rate. We confirm the robustness of the system to PMD by demonstrating error-free performance over an unrepeatered 124km field-installed single-mode fiber with a negligible penalty of 0.3dB compared to the back-to-back measurements.


Assuntos
Tecnologia de Fibra Óptica/métodos , Fibras Ópticas , Luz , Teste de Materiais
14.
Colloids Surf B Biointerfaces ; 57(1): 124-33, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17379485

RESUMO

Low density lipoproteins (LDL) from egg yolk have a classical structure of lipoprotein with a core of neutral lipids surrounded by a monolayer of apoproteins and phospholipids. This structure collapses during adsorption and all constituents spread at the interface. To understand better the nature of the interactions between apoproteins and lipids at the interface, we have deposited LDL at an air-water interface and analysed the isotherms during their compression on a Langmuir trough. Then, these LDL films were studied by atomic force microscopy (AFM) imaging. To identify the protein and lipid structures, we imaged films before and after lipid solubilisation by butanol. To study the interactions in the LDL films, we have varied the pH, ionic strength and used simplified model systems. We also studied the correlation between observed structures and interfacial rheology of the film. The isotherms of interfacial LDL films were similar for pH 3 and 7, but their structures observed in AFM were different. At surface pressures below the transition corresponding to the demixion of apoprotein-neutral lipid complexes, the LDL film structure was not governed by electrostatic interactions. However, above this surface pressure transition (45mN/m), there was an effect of charge on this structure. Around the transition zone, the rheological properties of LDL films at pH 3 were different as a function of pH (viscous at pH 3 and visco-elastic at pH 7). So, the rheological properties of LDL films could be linked to the structures formed by apoproteins and observed in AFM.


Assuntos
Gema de Ovo/química , Lipoproteínas LDL/química , Ar , Animais , Butanóis/química , Galinhas , Proteínas do Ovo/química , Elasticidade , Concentração de Íons de Hidrogênio , Lipídeos/química , Membranas Artificiais , Microscopia de Força Atômica , Reologia , Propriedades de Superfície , Termodinâmica , Água
15.
High Alt Med Biol ; 8(1): 50-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17394417

RESUMO

Using automated air gastric tonometry, the hypothesis that gastric perfusion is reduced while exercising at high altitude was explored. This prospective observational study of 5 well acclimatized healthy volunteers was performed during a medical research expedition to Chamlang base camp (5000 m), Hongu valley, Nepal. We used gastric tonometry at rest and during graded submaximal exercise. The end tidal partial pressure of carbon dioxide was subtracted from the gastric mucosal partial pressure of carbon dioxide to calculate the P(CO2) gradient, which is a marker of gastric mucosal perfusion. When compared with rest, there was no increase in the mean P(CO2) gradient at the lower work rate (0.22 vs. 0.18, p 0.10), but an increase was seen between rest and the higher work rate (0.22 vs. 0.77, p = 0.04). We conclude that exercising while at high altitude can lead to a raised P(CO2) gradient when gastric tonometry is performed, indicating reduced perfusion. This may represent reduced gastric mucosal perfusion under these conditions.


Assuntos
Dióxido de Carbono/metabolismo , Exercício Físico/fisiologia , Mucosa Gástrica/irrigação sanguínea , Mucosa Gástrica/metabolismo , Manometria/métodos , Adulto , Humanos , Masculino , Monitorização Fisiológica/métodos , Consumo de Oxigênio , Valores de Referência , Análise de Regressão , Volume de Ventilação Pulmonar
16.
Colloids Surf B Biointerfaces ; 54(2): 241-8, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-17137763

RESUMO

We have studied the structure of films made by low density lipoproteins (LDL) from hen egg yolk, which are composed of apoproteins, neutral lipids and phospholipids. These LDL have been deposited on air-water interface to form a monolayer which has been compressed to measure an isotherm using Langmuir balance. This isotherm presented three transitions (neutral lipid (surface pressure, pi=19 mN/m), apoprotein-lipid (pi=41 mN/m) and phospholipid (pi=51 mN/m) transitions). We have studied only the apoprotein-lipid transition. In order to observe the LDL film structure before (pi=30 mN/m) and after (pi=45 mN/m) the apoprotein-lipid transition, the formed films were transferred and visualised by atomic force microscopy (AFM). Our results have shown that the structures observed in the LDL film were different depending on the surface pressure. The apoproteins and neutral lipids appeared to be miscible up to the apoprotein-lipid transition, when demixing occurred. The structures observed after the apoprotein-lipid transition should be due to the demixing between apoproteins and neutral lipids. On the other hand, apoproteins and phospholipids seemed miscible whatever the surface pressure. Hence, the first transition (pi=19 mN/m) should be attributed to the free neutral lipid collapse; the second transition (pi=41 mN/m) should be attributed to the demixing of apoprotein-neutral lipid complexes; and the last transition (pi=51 mN/m) should be attributed to phospholipid collapse or to demixing of apoprotein-phospholipid complexes.


Assuntos
Proteínas do Ovo/química , Gema de Ovo/química , Lipoproteínas LDL/química , Microscopia de Força Atômica , Animais , Galinhas , Feminino
17.
Biomaterials ; 27(16): 3136-46, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16473404

RESUMO

The purpose of this study was to produce a well-characterised electrospun polystyrene scaffold which could be used routinely for three-dimensional (3D) cell culture experimentation. A linear relationship (p<0.01) between three principal process variables (applied voltage, working distance and polymer concentration) and fibre diameter was reliably established enabling a mathematical model to be developed to standardise the electrospinning process. Surface chemistry and bulk architecture were manipulated to increase wetting and handling characteristics, respectively. X-ray photoelectron spectroscopy (XPS) confirmed the presence of oxygen-containing groups after argon plasma treatment, resulting in a similar surface chemistry to treated tissue culture plastic. The bulk architecture of the scaffolds was characterised by scanning electron microscopy (SEM) to assess the alignment of both random and aligned electrospun fibres, which were calculated to be 0.15 and 0.66, respectively. This compared to 0.51 for collagen fibres associated with native tissue. Tensile strength and strain of approximately of 0.15 MPa and 2.5%, respectively, allowed the scaffolds to be routinely handled for tissue culture purposes. The efficiency of attachment of smooth muscle cells to electrospun scaffolds was assessed using a modified 3-[4,5-dimethyl(thiazol-2yl)-3,5-diphery] tetrazolium bromide assay and cell morphology was assessed by phalloidin-FITC staining of F-actin. Argon plasma treatment of electrospun polystyrene scaffold resulted in significantly increased cell attachment (p<0.05). The alignment factors of the actin filaments were 0.19 and 0.74 for the random and aligned scaffold respectively, compared to 0.51 for the native tissue. The data suggests that electrospinning of polystyrene generates 3D scaffolds which complement polystyrene used in 2D cell culture systems.


Assuntos
Plásticos/química , Poliestirenos/química , Técnicas de Cultura de Tecidos/métodos , Animais , Argônio/química , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Clorofórmio/química , Elasticidade , Humanos , Microscopia Confocal , Microscopia Eletrônica de Varredura , Miócitos de Músculo Liso/citologia , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Tamanho da Partícula , Plásticos/farmacologia , Porosidade , Reprodutibilidade dos Testes , Espectrometria por Raios X , Suínos , Resistência à Tração , Bexiga Urinária/citologia , Molhabilidade
18.
Biochem Biophys Res Commun ; 325(4): 1258-63, 2004 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-15555562

RESUMO

Although the route of sensitization to food allergens is still the subject of debate, it is generally accepted the gut immune system plays a pivotal role. However, hitherto the transport of allergens across the normal, pre-sensitized gut epithelium remained largely unknown. Our aim was to identify the route through which protein bodies and soluble proteins from digested peanuts penetrated the pre-sensitized gut epithelium in vivo and the specific cell types involved in the transport. Digestion of peanuts released a large number of protein bodies that are exclusively transported across the epithelium by specialized antigen-sampling M cells and delivered to the lymphoid tissue of Peyer's patch. Intracellular transport of soluble protein also occurred almost exclusively via M cells and it was negligible across absorptive enterocytes. We hypothesize that these conditions which are known to favour strongly the induction of immune responses rather than oral tolerance may play a significant role in the genesis of allergic reactions.


Assuntos
Alérgenos/metabolismo , Arachis/química , Mucosa Intestinal/metabolismo , Nódulos Linfáticos Agregados/metabolismo , Proteínas de Plantas/metabolismo , Alérgenos/imunologia , Animais , Arachis/imunologia , Transporte Biológico Ativo/fisiologia , Digestão/imunologia , Digestão/fisiologia , Imunização/métodos , Mucosa Intestinal/citologia , Mucosa Intestinal/imunologia , Camundongos , Camundongos Endogâmicos BALB C , Nódulos Linfáticos Agregados/citologia , Nódulos Linfáticos Agregados/imunologia , Proteínas de Plantas/imunologia , Transporte Proteico/fisiologia
19.
Biomacromolecules ; 5(3): 984-91, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15132691

RESUMO

The displacement of the proteins (beta-lactoglobulin and beta-casein) from an air-water interface by the nonionic (Tween 20 and Tween 60) and ionic (sodium dodecyl sulfate, cetyltrimethylammonium bromide, and lyso-phosphatidylcholine-lauroyl) surfactants has been visualized by atomic force microscopy (AFM). The surface structure has been sampled by the use of Langmuir-Blodgett deposition onto mica substrates to allow imaging in the AFM. In all cases, the displacement process was found to occur through the recently proposed orogenic mechanism (Mackie et al. J. Colloid Interface Sci. 1999, 210, 157-166). In the case of the nonionic surfactants, the displacement involved nucleation and growth of surfactant domains leading to failure of the protein network and subsequent loss of protein into the bulk phase. The surface pressure dependence of the growth of surfactant domains and the failure of the network were found to be the same for both Tween 20 and Tween 60, demonstrating that the breakdown of the protein film was dominated by the mechanical properties of the network. The displacement of protein by ionic surfactants was found to be characterized by nucleation of surfactant domains with little domain growth prior to failure of the network. The size of the domains formed by ionic surfactants was found to be limited by the strong intersurfactant repulsive forces between the charged headgroups. Screening of these charges led to an increase in the size of the domains. The surface pressure at which the network continuity was lost was found to be dependent on the type of surfactant and, in all cases, to occur at higher surface pressures than that required for nonionic surfactants. This has been attributed to surfactant-protein binding that initially strengthens the protein network at low surfactant concentrations. Evidence obtained from surface shear rheology supports this assertion.


Assuntos
Caseínas/química , Lactoglobulinas/química , Tensoativos/química , Microscopia de Força Atômica , Ligação Proteica
20.
J Agric Food Chem ; 52(5): 1287-92, 2004 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-14995135

RESUMO

Atomic force microscopy (AFM) has been used to investigate the displacement of a commercial whey protein system and the behavior as compared to that of beta-lactoglobulin (Mackie, A. R.; Gunning, A. P.; Wilde, P. J.; Morris, V. J. Orogenic displacement of protein from the air-water interface by competitive adsorption. J. Colloid Interface Sci. 1999, 210, 157-166). The whey protein isolate (WPI) was displaced from an air-water interface by the surfactants Tween 20 and Tween 60. Displacement data obtained were compared with data obtained for pure beta-lactoglobulin and have shown that WPI was more resistant to displacement from the air-water interface than native beta-lactoglobulin. This was related to the greater surface elasticity of WPI at higher surface stresses. In the presence of Tween 20, WPI was observed to remain on the interface at surface pressures up to 8 mN/m greater than the surface pressure at which complete displacement of beta-lactoglobulin was observed. Displacement of WPI and beta-lactoglobulin films by the surfactant Tween 60 showed similar results. However, because of the lower surface activity of Tween 60, it was not possible to reach surface tension values similar to those obtained for Tween 20. Despite the lower surface activity of Tween 60, WPI was still observed to be present at the interface at surface pressure values greater than those by which beta-lactoglobulin had been completely displaced.


Assuntos
Manipulação de Alimentos/métodos , Proteínas do Leite/química , Fenômenos Químicos , Físico-Química , Lactoglobulinas/química , Microscopia de Força Atômica , Tensão Superficial , Tensoativos , Proteínas do Soro do Leite
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA