Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Heliyon ; 10(10): e31181, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38807885

RESUMO

Purpose: This study aimed to explore the practices of optometrists in Hong Kong towards diagnosing and managing dry eye disease (DED). Methods: From September 2021 to March 2022, an online questionnaire was distributed to optometrists in Hong Kong through several professional associations. The questionnaire included questions about the importance and usefulness of various diagnostic tests, as well as inquiries about management strategies and recommended follow-up schedules for DED. Responses were compared between optometrists who were more or less proactive in continuing education to identify potential differences. Results: The analysis included 68 valid responses. Sixty-one of them were Part 1 optometrists that represents 5.5 % of registered Part 1 optometrists back in 2022. Assessment of clinical symptoms was the most commonly performed investigation (93 %) and considered the most important (75 %) procedure in DED assessments, followed by corneal staining and fluorescein tear break-up time. Traditional diagnostic tests were preferred over newer methods, such as osmolarity, which were not yet commonly used. Unpreserved lubricants (90 %) and lid hygiene (63 %) were the primary treatments recommended for mild DED. Optometrists who had more experience and frequent participation in continuing education were more confident in diagnosing and managing DED, and more likely to recommend omega-3 supplements for moderate DED. Conclusion: The diagnostic and management strategies of optometrists in Hong Kong were generally consistent with the recommendations of the Dry Eye Workshop II report. However, standardized DED questionnaires and newer diagnostic tools were not commonly used. Evidence-based optometric care for dry eye management should be encouraged in Hong Kong optometric practice.

2.
Cont Lens Anterior Eye ; 46(5): 102047, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37626009

RESUMO

PURPOSE: To report the characteristics (prevalence, severity, and location) of corneal epithelial microcysts and investigate associated risk factors in children wearing orthokeratology (ortho-k) lenses. METHOD: Ninety-five myopic children wearing ortho-k lenses (examined by one of three independent investigators from March to September 2020) were included in this retrospective cross-sectional study. Pertinent data at baseline before ortho-k treatment and at the aftercare visits (the first visit when the microcysts were observed for children with microcysts, and the last visit before October 2020 for children without microcysts) were retrieved and analysed. RESULTS: A microcystic response was observed in 52.6% of children wearing ortho-k lenses. Children with high myopia (≥ 5.00 D) had a higher prevalence (100.0%, 23/23) and severity (69.5% (16/23) > grade 2 Efron scale) compared to children with low myopia (≤ 4.00 D) (prevalence of 37.5% (27/72) and 7.0% (5/72) > grade 2, p < 0.001). Microcysts were predominantly (86.0%) observed in the region of the inferior pigmented arc, typically originating in the inferior mid-peripheral cornea, and expanding over time into a semi- or whole annulus. Baseline myopia and topographical change at the treatment zone centre were significantly greater (p < 0.05) in low myopic children with microcysts (univariate analyses). CONCLUSIONS: During the COVID-19 pandemic, probably due to lifestyle changes, microcysts were frequently observed in children wearing ortho-k lenses and were associated with higher baseline myopia. Practitioners should examine ortho-k wearers with caution using a slit lamp with high magnification and illumination, especially the mid-peripheral cornea. The use of highly oxygen permeable lenses and frequent aftercare are necessary for ortho-k wearers, especially those with higher myopia.


Assuntos
COVID-19 , Cistos , Miopia , Humanos , Criança , Estudos Transversais , Hong Kong/epidemiologia , Pandemias , Estudos Retrospectivos , Córnea , Miopia/terapia
3.
Ophthalmic Physiol Opt ; 43(6): 1449-1461, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37545099

RESUMO

PURPOSE: To compare axial elongation (AE) and treatment zone (TZ) characteristics in children wearing 6 mm or 5 mm back optic zone diameter (BOZD) orthokeratology (ortho-k) lenses over 2 years. METHODS: Forty-five (6 to <11 years of age) myopic (-4.00 to -0.75 D) children of Chinese ethnicity were randomly assigned to use the two different lens designs (23 and 22 wore the 6 and 5 mm lenses, respectively). Data collection was performed at baseline and every 6-months after commencing lens wear. RESULTS: After 24 months, subjects wearing lenses with a 5 mm BOZD achieved smaller TZ diameter (horizontal: 2.69 ± 0.28 vs. 3.84 ± 0.39 mm; vertical: 2.65 ± 0.22 vs. 3.42 ± 0.34 mm, p < 0.001) and less AE (0.15 ± 0.21 vs. 0.35 ± 0.23, p = 0.005) compared to those using the 6 mm design, with no difference in choroidal thickness (ChT) changes (p = 0.93). A significant increase in ChT, using pooled data analysis, was noted at the 6-month (11.8 ± 19.77 µm, p < 0.001) and 12-month (12.0 ± 23.7 µm, p = 0.004) visits, compared to baseline, indicating a transient change in ChT. Significant associations were noted, using linear mixed models, between AE and the TZ diameters (p < 0.003) after adjusting for baseline data. A very weak association was found between ChT changes and AE, with the effect size close to zero. CONCLUSIONS: Smaller BOZD ortho-k lenses resulted in a smaller TZ diameter, which was associated with less AE after 2 years of treatment. The changes in ChT played a very weak role, suggesting that other factors may contribute more to the reduced AE in subjects wearing lenses having a smaller BOZD.

4.
Eye Vis (Lond) ; 10(1): 25, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37391828

RESUMO

PURPOSE: To compare changes in ocular aberrations in children wearing orthokeratology (ortho-k) lenses with a back optic zone diameter (BOZD) of 6 mm (6-MM group) or 5 mm (5-MM group) and their associations with axial elongation (AE) over two years. METHODS: Seventy Chinese children, aged 6 to < 11 years, with myopia between - 4.00 to - 0.75 D, were randomly allocated to 5-MM and 6-MM groups. Ocular aberrations were measured, rescaled to a 4-mm pupil, and fitted with a 6th order Zernike expansion. Measurements, including axial length, were taken prior to commencing ortho-k treatment and then every six months over two years. RESULTS: After two years, the 5-MM group displayed a smaller horizontal treatment zone (TZ) diameter (by 1.14 ± 0.11 mm, P < 0.001) and less AE (by 0.22 ± 0.07 mm, P = 0.002) compared with the 6-MM group. A greater increase in total root mean square (RMS) of higher-order aberrations (HOAs), primary spherical aberration (SA) ([Formula: see text], and coma were also observed in the 5-MM group at all follow-up visits. The horizontal TZ diameter was significantly associated with changes in RMS HOAs, SA (RMS, primary and secondary SA), and RMS coma. After controlling for baseline parameters, RMS HOAs, RMS SA, RMS coma, and primary ([Formula: see text] and secondary ([Formula: see text] SA were significantly associated with AE. CONCLUSIONS: Ortho-k lenses with a smaller BOZD created a smaller horizontal TZ diameter and a significant increase in total HOAs, total SA, total coma, and primary SA and a decrease in secondary SA. Of these ocular aberrations, total HOAs, total SA, and primary SA were negatively correlated with AE over two years. TRIAL REGISTRATION: ClinicalTrial.gov, NCT03191942. Registered 19 June 2017, https://clinicaltrials.gov/ct2/show/NCT03191942 .

5.
Ophthalmic Physiol Opt ; 42(4): 773-785, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35366332

RESUMO

PURPOSE: To compare the treatment zone (TZ) measurements obtained using manual and software-based methods in orthokeratology (ortho-k) subjects and explore the TZ characteristics of children with slow and fast axial elongation after ortho-k. METHODS: Data from 69 subjects (aged 7 to <13 years old), who participated in three 24-month longitudinal orthokeratology studies, showing fast (>0.27 mm, n = 38) and slow (<0.09 mm, n = 31) axial elongation, were retrieved. The TZ after ortho-k was defined as the central flattened area enclosed by points with no refractive power change. TZ parameters, including decentration, size, width of the peripheral steepened zone (PSZ), central and peripheral refractive power changes and peripheral rate of power change, were determined manually and using python-based software. TZ parameters were compared between measurement methods and between groups. RESULTS: Almost all TZ parameters measured manually and with the aid of software were significantly different (p < 0.05). Differences in decentration, size and the PSZ width were not clinically significant, but differences (0.45 to 0.92 D) in refractive power change in the PSZ were significant, although intraclass coefficients (0.95 to 0.98) indicated excellent agreement between methods. Significantly greater TZ decentration, smaller TZ size and greater inferior rate of power change (relative to the TZ centre) were observed in slow progressors using both methods, suggesting a potential role of TZ in regulating myopia progression in ortho-k. CONCLUSION: TZ measurements using manual and software-based methods differed significantly and cannot be used interchangeably. The combination of TZ decentration, TZ size and peripheral rate of power change may affect myopia control effect in ortho-k.


Assuntos
Miopia , Procedimentos Ortoceratológicos , Adolescente , Comprimento Axial do Olho , Criança , Topografia da Córnea , Humanos , Miopia/diagnóstico , Miopia/terapia , Procedimentos Ortoceratológicos/métodos , Refração Ocular , Software
6.
Cont Lens Anterior Eye ; 45(4): 101484, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34303626

RESUMO

PURPOSE: To investigate the repeatability and reproducibility of choroidal thickness measurements using Lenstar images in young myopic children before and after one-month orthokeratology (ortho-k) treatment. METHOD: Ocular biometry of 39 subjects were performed using the Lenstar 900. The first five measurements with maximum differences of 0.02 mm in axial length in the right eyes were saved and used for measurement of choroidal thickness. Subfoveal choroidal thickness were manually measured by identifying the signals from the retinal pigmented epithelium layer and chorioscleral interface. Repeatability was determined by comparing measurements of the same images made by the same observer on two separate occasions (four weeks apart), while reproducibility was calculated by comparing measurements of the same images made by two independent observers. Data was analysed using intra-class correlation coefficients (ICC) and non-parametric Bland and Altman plots. RESULTS: The choroidal peaks could not be identified in all five measurements in all subjects. On average, only 71% subjects had at least four definable images. Compared with the use of fewer than four images, reliability using an average of four definable images improved statistically, but remained clinically unacceptable (>10 µm), although pre- and post-ortho-k ICC values were good to excellent for repeatability (0.867 and 0.975, respectively) and excellent and good for reproducibility (0.959 and 0.868, respectively). Non-parametric pre- and post-ortho-k limits of agreement (2.5% and 97.5% percentiles) obtained were -45.8 to 79.3 µm and -30.3 to 9.5 µm, respectively for repeatability, and -29.0 to 33.5 µm and -21.8 to 70.0 µm, respectively for reproducibility. CONCLUSION: Choroidal thickness measurements using the Lenstar did not show good reliability, despite the high ICC values, non-parametric Bland and Altman plots demonstrated a wide variability of measurement errors. Any changes in subfoveal choroidal thickness, measured by Lenstar, of <80 µm may not represent real changes.


Assuntos
Miopia , Tomografia de Coerência Óptica , Biometria , Criança , Corioide/diagnóstico por imagem , Humanos , Miopia/terapia , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
7.
Ophthalmic Physiol Opt ; 41(4): 702-714, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33991112

RESUMO

PURPOSE: To present the 1-year results of the Variation of Orthokeratology Lens Treatment Zone (VOLTZ) Study, which aims to investigate the myopia control effect of orthokeratology (ortho-k) lenses with different back optic zone diameters (BOZD). METHOD: Children, aged 6 to <11 years, having myopia -4.00 D to -0.75 D, were randomly assigned to wear ortho-k lenses with 6 mm (6-MM group) or 5 mm (5-MM group) BOZD. Data collection included changes in refraction, vision, lens performance and binding, ocular health conditions, axial length and characteristics of the treatment zone (TZ) area. RESULTS: The 1-year results of 34 and 36 subjects (right eye only) in the 6-MM and 5-MM groups, respectively, are presented. No significant differences in baseline demographics were found between the groups (p > 0.05). The first-fit success rates, based on satisfactory centration at the 1-month visit, were 100% and 94% respectively. Horizontal TZ size was 0.92 mm and 0.72 mm smaller in the 5-MM group at the 6-month and 12-month visits, respectively (p < 0.05). At the 12-month visit, no significant between-group differences were found in the incidence of corneal staining (low grade only), lens binding and visual performance (all p > 0.05). Axial elongation was slower in the 5-MM group (0.04 ± 0.15 mm) than the 6-MM group (0.17 ± 0.13 mm) (p = 0.001). A significant positive correlation was observed between the horizontal TZ size and axial elongation (r = 0.36, p = 0.006). CONCLUSION: Clinical performance of the two ortho-k lenses was similar, indicating that a smaller BOZD (5 mm) did not affect lens performance or ocular integrity. However, a smaller BOZD led to a reduced TZ, with retardation of axial elongation by 0.13 mm compared to conventional 6 mm BOZD ortho-k lenses after one year of lens wear.


Assuntos
Lentes de Contato , Miopia , Procedimentos Ortoceratológicos , Comprimento Axial do Olho , Criança , Topografia da Córnea , Humanos , Miopia/terapia , Estudos Prospectivos , Refração Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA