Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Heliyon ; 10(5): e27138, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38455530

RESUMO

Irrigation of crops with domestic wastewater (DW) is a common practice in developing countries like India. However, domestic wastewater irrigation poses a risk of migration of toxic heavy metals to edible parts of crops, which requires serious measures to prevent their uptake. In this study, the effect of DW irrigation in comparison with Sarbal Lake water (SLW) and borewell water (BW) on soil characteristics and cultivated saffron (Crocus sativus L.) was investigated. For this purpose, samples of water, soil, and saffron (corm, petal, and stigma) were collected from the suburban area of Pampore, Srinagar district, Jammu and Kashmir, India. The results showed that DW irrigation had the maximum significant (p < 0.05) influence on the physico-chemical and nutrient characteristics of the soil, followed by SLW and BW irrigation, respectively. The growth and yield parameters of saffron were also significantly (p < 0.05) increased in the case of DW irrigation as compared to SLW and BW. The quality ranking of the cultivated saffron was found to be in accordance with the ISO standard (III: BW and II: DW and SLW). On the other hand, DW irrigation showed a significant increase in heavy metal contents (mg/kg) of saffron plant parts such as As (0.21-0.40), Cd (0.04-0.09), Cr (0.16-0.41), Cu (7.31-14. 75), Fe (142.38-303.15), Pb (0.18-0.31), Mn (15.26-22.81), Hg (0.18-0.25), Ni (0.74-1.18), Se (0.13-0.22), and Zn (3.44-4.59), followed by SLW and BW. However, the levels of heavy metals did not exceed the FAO/WHO safe limits. Bioaccumulation factor (BAF), dietary intake modeling (DIM<0.006496), health risk assessment (HRI<0.028571), and target hazard quotient (THQ<1) analyses showed no potential health hazard associated with the consumption of saffron irrigated with DW and SLW. Therefore, the results of this study provide valuable insights into the optimization of irrigation sources for saffron cultivation.

2.
Comput Biol Med ; 140: 105102, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34973521

RESUMO

MOTIVATION: Machine learning (ML) algorithms can provide better cardiovascular event (CVE) prediction. However, ML algorithms are mostly explored for predicting a single CVE at a time. The objective of this study is to design and develop an ML-based system to predict multi-label CVEs, such as (i) coronary artery disease, (ii) acute coronary syndrome, and (iii) a composite CVE-a class of AtheroEdge 3.0 (ML) system. METHODS: Focused carotid B-mode ultrasound and coronary angiography are performed on a group of 459 participants consisting of three cardiovascular labels. Initially, 23 risk predictors comprising (i) patients' demographics, (ii) clinical blood-biomarkers, and (iii) carotid ultrasound image-based phenotypes are collected. Six types of classification techniques comprising (a) four problem transformation methods (PTM) and (b) two algorithm adaptation methods (AAM) are used for multi-label CVE prediction. The performance of the proposed system is evaluated for accuracy, sensitivity, specificity, F1-score, and area-under-the-curve (AUC) using 10-fold cross-validation. The proposed system is also verified using another database of 522 participants. RESULTS: For the primary database, PTM demonstrated a better multi-label CVE prediction than AAM (mean accuracy: 80.89% vs. 62.83%, mean AUC: 0.89 vs. 0.63), validating our hypothesis. The PTM-based binary relevance (BR) technique provided optimal performance in multi-label CVE prediction. The overall multi-label classification accuracy, sensitivity, specificity, F1-score, and AUC using BR are 81.2 ± 3.01%, 76.5 ± 8.8%, 83.8 ± 3.8%, 75.37 ± 5.8%, and 0.89 ± 0.02 (p < 0.0001), respectively. When used on the second Canadian database with seven cardiovascular events (acute coronary syndrome, myocardial infarction, angina, stroke, transient ischemic attack, heart failure, and death), the proposed system showed an accuracy of 96.36 ± 0.87% (AUC: 0.61 ± 0.06, p < 0.0001). CONCLUSION: ML-based multi-label classification algorithms, such as binary relevance, yielded the best predictions for three cardiovascular endpoints.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Canadá , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Humanos , Aprendizado de Máquina , Placa Aterosclerótica/diagnóstico por imagem , Medição de Risco , Fatores de Risco
3.
Int Angiol ; 40(2): 150-164, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33236868

RESUMO

Chronic kidney disease (CKD) and cardiovascular disease (CVD) together result in an enormous burden on global healthcare. The estimated glomerular filtration rate (eGFR) is a well-established biomarker of CKD and is associated with adverse cardiac events. This review highlights the link between eGFR reduction and that of atherosclerosis progression, which increases the risk of adverse cardiovascular events. In general, CVD risk assessments are performed using conventional risk prediction models. However, since these conventional models were developed for a specific cohort with a unique risk profile and further these models do not consider atherosclerotic plaque-based phenotypes, therefore, such models can either underestimate or overestimate the risk of CVD events. This review examined the approaches used for CVD risk assessments in CKD patients using the concept of integrated risk factors. An integrated risk factor approach is one that combines the effect of conventional risk predictors and non-invasive carotid ultrasound image-based phenotypes. Furthermore, this review provided insights into novel artificial intelligence methods, such as machine learning and deep learning algorithms, to carry out accurate and automated CVD risk assessments and survival analyses in patients with CKD.


Assuntos
Doenças Cardiovasculares , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Inteligência Artificial , Doenças Cardiovasculares/diagnóstico por imagem , Taxa de Filtração Glomerular , Humanos , Fenótipo , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Medição de Risco , Fatores de Risco , Ultrassom
4.
Int J Cardiovasc Imaging ; 37(4): 1171-1187, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33184741

RESUMO

Machine learning (ML)-based algorithms for cardiovascular disease (CVD) risk assessment have shown promise in clinical decisions. However, they usually predict binary events using only conventional risk factors. Our overall goal was to develop the "multiclass machine learning (MCML)-based algorithms" (labelled as AtheroEdge 3.0ML) and assess whether considering carotid ultrasound imaging fused with conventional risk factors can provide better CVD/stroke risk prediction than conventional CVD risk calculators (CCVRC). Carotid ultrasound and coronary angiography were performed on 500 participants. Stenosis in the coronary arteries was used to assign participants a coronary angiographic score (CAS). CVD/stroke risk was determined using three types of MCML algorithms: (i) support vector machine (SVM), (ii) random forest (RF), and (iii) extreme gradient boost (XGBoost). The performance of CVD risk assessment using MCML and CCVRC (such as Framingham Risk Score, the Systematic Coronary Risk Evaluation score, and the Atherosclerotic CVD) was evaluated on test patients against the CAS as the gold standard for each class using the area-under-the-curve (AUC) and classification accuracy. The mean percentage improvement in AUC and the mean absolute improvement in accuracy over CCVRC using 90% training and 10% testing protocol (labelled as K10) were ~ 105% and ~ 28%, respectively. Of all the three MCML systems, RF showed the best performance. Further, carotid image phenotypes showed the most effective clinical feature in AtheroEdge 3.0ML performance. The AtheroEdge 3.0ML using carotid imaging are reliable, accurate, and superior to traditional CVD risk scoring methods for predicting the CVD/stroke risk due to coronary artery disease.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Técnicas de Apoio para a Decisão , Diagnóstico por Computador , Aprendizado de Máquina , Placa Aterosclerótica , Acidente Vascular Cerebral/etiologia , Ultrassonografia , Idoso , Estenose das Carótidas/complicações , Estenose Coronária/complicações , Estudos Transversais , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Medição de Risco , Máquina de Vetores de Suporte
5.
J Med Syst ; 44(12): 208, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33175247

RESUMO

This study developed an office-based cardiovascular risk calculator using a machine learning (ML) algorithm that utilized a focused carotid ultrasound. The design of this study was divided into three steps. The first step involved collecting 18 office-based biomarkers consisting of six clinical risk factors (age, sex, body mass index, systolic blood pressure, diastolic blood pressure, and smoking) and 12 carotid ultrasound image-based phenotypes. The second step consisted of the design of an ML-based cardiovascular risk calculator-called "AtheroEdge Composite Risk Score 2.0" (AECRS2.0ML) for risk stratification, considering chronic kidney disease (CKD) as the surrogate endpoint of cardiovascular disease. The last step consisted of comparing AECRS2.0ML against the currently utilized office-based CVD calculators, namely the Framingham risk score (FRS) and the World Health Organization (WHO) risk scores. A cohort of 379 Asian-Indian patients with type-2 diabetes mellitus, hypertension, and chronic kidney disease (stage 1 to 5) were recruited for this cross-sectional study. From this retrospective cohort, 758 ultrasound scan images were acquired from the far walls of the left and right common carotid arteries [mean age = 55 ± 10.8 years, 67.28% males, 91.82% diabetic, 86.54% hypertensive, and 83.11% with CKD]. The mean office-based cardiovascular risk estimates using FRS and WHO calculators were 26% and 19%, respectively. AECRS2.0ML demonstrated a better risk stratification ability having a higher area-under-the-curve against FRS and WHO by ~30% (0.871 vs. 0.669) and ~ 20% (0.871 vs. 0.727), respectively. The office-based machine-learning cardiovascular risk-stratification tool (AECRS2.0ML) shows superior performance compared to currently available conventional cardiovascular risk calculators.


Assuntos
Doenças Cardiovasculares , Doenças Cardiovasculares/diagnóstico por imagem , Estudos Transversais , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Recém-Nascido , Aprendizado de Máquina , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
6.
Comput Biol Med ; 126: 104043, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33065389

RESUMO

RECENT FINDINGS: Cardiovascular disease (CVD) is the leading cause of mortality and poses challenges for healthcare providers globally. Risk-based approaches for the management of CVD are becoming popular for recommending treatment plans for asymptomatic individuals. Several conventional predictive CVD risk models based do not provide an accurate CVD risk assessment for patients with different baseline risk profiles. Artificial intelligence (AI) algorithms have changed the landscape of CVD risk assessment and demonstrated a better performance when compared against conventional models, mainly due to its ability to handle the input nonlinear variations. Further, it has the flexibility to add risk factors derived from medical imaging modalities that image the morphology of the plaque. The integration of noninvasive carotid ultrasound image-based phenotypes with conventional risk factors in the AI framework has further provided stronger power for CVD risk prediction, so-called "integrated predictive CVD risk models." PURPOSE: of the review: The objective of this review is (i) to understand several aspects in the development of predictive CVD risk models, (ii) to explore current conventional predictive risk models and their successes and challenges, and (iii) to refine the search for predictive CVD risk models using noninvasive carotid ultrasound as an exemplar in the artificial intelligence-based framework. CONCLUSION: Conventional predictive CVD risk models are suboptimal and could be improved. This review examines the potential to include more noninvasive image-based phenotypes in the CVD risk assessment using powerful AI-based strategies.


Assuntos
Doenças Cardiovasculares , Placa Aterosclerótica , Acidente Vascular Cerebral , Inteligência Artificial , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Artérias Carótidas/diagnóstico por imagem , Humanos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia
7.
Cardiovasc Diagn Ther ; 10(4): 919-938, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32968651

RESUMO

BACKGROUND: Statistically derived cardiovascular risk calculators (CVRC) that use conventional risk factors, generally underestimate or overestimate the risk of cardiovascular disease (CVD) or stroke events primarily due to lack of integration of plaque burden. This study investigates the role of machine learning (ML)-based CVD/stroke risk calculators (CVRCML) and compares against statistically derived CVRC (CVRCStat) based on (I) conventional factors or (II) combined conventional with plaque burden (integrated factors). METHODS: The proposed study is divided into 3 parts: (I) statistical calculator: initially, the 10-year CVD/stroke risk was computed using 13 types of CVRCStat (without and with plaque burden) and binary risk stratification of the patients was performed using the predefined thresholds and risk classes; (II) ML calculator: using the same risk factors (without and with plaque burden), as adopted in 13 different CVRCStat, the patients were again risk-stratified using CVRCML based on support vector machine (SVM) and finally; (III) both types of calculators were evaluated using AUC based on ROC analysis, which was computed using combination of predicted class and endpoint equivalent to CVD/stroke events. RESULTS: An Institutional Review Board approved 202 patients (156 males and 46 females) of Japanese ethnicity were recruited for this study with a mean age of 69±11 years. The AUC for 13 different types of CVRCStat calculators were: AECRS2.0 (AUC 0.83, P<0.001), QRISK3 (AUC 0.72, P<0.001), WHO (AUC 0.70, P<0.001), ASCVD (AUC 0.67, P<0.001), FRScardio (AUC 0.67, P<0.01), FRSstroke (AUC 0.64, P<0.001), MSRC (AUC 0.63, P=0.03), UKPDS56 (AUC 0.63, P<0.001), NIPPON (AUC 0.63, P<0.001), PROCAM (AUC 0.59, P<0.001), RRS (AUC 0.57, P<0.001), UKPDS60 (AUC 0.53, P<0.001), and SCORE (AUC 0.45, P<0.001), while the AUC for the CVRCML with integrated risk factors (AUC 0.88, P<0.001), a 42% increase in performance. The overall risk-stratification accuracy for the CVRCML with integrated risk factors was 92.52% which was higher compared all the other CVRCStat. CONCLUSIONS: ML-based CVD/stroke risk calculator provided a higher predictive ability of 10-year CVD/stroke compared to the 13 different types of statistically derived risk calculators including integrated model AECRS 2.0.

8.
Cardiovasc Diagn Ther ; 10(4): 939-954, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32968652

RESUMO

BACKGROUND: Vascular age (VA) has recently emerged for CVD risk assessment and can either be computed using conventional risk factors (CRF) or by using carotid intima-media thickness (cIMT) derived from carotid ultrasound (CUS). This study investigates a novel method of integrating both CRF and cIMT for estimating VA [so-called integrated VA (IVA)]. Further, the study analyzes and compares CVD/stroke risk using the Framingham Risk Score (FRS)-based risk calculator when adapting IVA against VA. METHODS: The system follows a four-step process: (I) VA using cIMT based using linear-regression (LR) model and its coefficients; (II) VA prediction using ten CRF using a multivariate linear regression (MLR)-based model with gender adjustment; (III) coefficients from the LR-based model and MLR-based model are combined using a linear model to predict the final IVA; (IV) the final step consists of FRS-based risk stratification with IVA as inputs and benchmarked against FRS using conventional method of CA. Area-under-the-curve (AUC) is computed using IVA and benchmarked against CA while taking the response variable as a standardized combination of cIMT and glycated hemoglobin. RESULTS: The study recruited 648 patients, 202 were Japanese, 314 were Asian Indian, and 132 were Caucasians. Both left and right common carotid arteries (CCA) of all the population were scanned, thus a total of 1,287 ultrasound scans. The 10-year FRS using IVA reported higher AUC (AUC =0.78) compared with 10-year FRS using CA (AUC =0.66) by ~18%. CONCLUSIONS: IVA is an efficient biomarker for risk stratifications for patients in routine practice.

9.
Rheumatol Int ; 40(12): 1921-1939, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32857281

RESUMO

Rheumatoid arthritis (RA) is a systemic chronic inflammatory disease that affects synovial joints and has various extra-articular manifestations, including atherosclerotic cardiovascular disease (CVD). Patients with RA experience a higher risk of CVD, leading to increased morbidity and mortality. Inflammation is a common phenomenon in RA and CVD. The pathophysiological association between these diseases is still not clear, and, thus, the risk assessment and detection of CVD in such patients is of clinical importance. Recently, artificial intelligence (AI) has gained prominence in advancing healthcare and, therefore, may further help to investigate the RA-CVD association. There are three aims of this review: (1) to summarize the three pathophysiological pathways that link RA to CVD; (2) to identify several traditional and carotid ultrasound image-based CVD risk calculators useful for RA patients, and (3) to understand the role of artificial intelligence in CVD risk assessment in RA patients. Our search strategy involves extensively searches in PubMed and Web of Science databases using search terms associated with CVD risk assessment in RA patients. A total of 120 peer-reviewed articles were screened for this review. We conclude that (a) two of the three pathways directly affect the atherosclerotic process, leading to heart injury, (b) carotid ultrasound image-based calculators have shown superior performance compared with conventional calculators, and (c) AI-based technologies in CVD risk assessment in RA patients are aggressively being adapted for routine practice of RA patients.


Assuntos
Artrite Reumatoide/fisiopatologia , Aterosclerose/diagnóstico , Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Artrite Reumatoide/complicações , Aterosclerose/complicações , Aterosclerose/fisiopatologia , Artérias Carótidas/patologia , Aprendizado Profundo , Progressão da Doença , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Medição de Risco
10.
Indian Heart J ; 72(4): 258-264, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32861380

RESUMO

MOTIVATION: Machine learning (ML)-based stroke risk stratification systems have typically focused on conventional risk factors (CRF) (AtheroRisk-conventional). Besides CRF, carotid ultrasound image phenotypes (CUSIP) have shown to be powerful phenotypes risk stratification. This is the first ML study of its kind that integrates CUSIP and CRF for risk stratification (AtheroRisk-integrated) and compares against AtheroRisk-conventional. METHODS: Two types of ML-based setups called (i) AtheroRisk-integrated and (ii) AtheroRisk-conventional were developed using random forest (RF) classifiers. AtheroRisk-conventional uses a feature set of 13 CRF such as age, gender, hemoglobin A1c, fasting blood sugar, low-density lipoprotein, and high-density lipoprotein (HDL) cholesterol, total cholesterol (TC), a ratio of TC and HDL, hypertension, smoking, family history, triglyceride, and ultrasound-based carotid plaque score. AtheroRisk-integrated system uses the feature set of 38 features with a combination of 13 CRF and 25 CUSIP features (6 types of current CUSIP, 6 types of 10-year CUSIP, 12 types of quadratic CUSIP (harmonics), and age-adjusted grayscale median). Logistic regression approach was used to select the significant features on which the RF classifier was trained. The performance of both ML systems was evaluated by area-under-the-curve (AUC) statistics computed using a leave-one-out cross-validation protocol. RESULTS: Left and right common carotid arteries of 202 Japanese patients were retrospectively examined to obtain 404 ultrasound scans. RF classifier showed higher improvement in AUC (~57%) for leave-one-out cross-validation protocol. Using RF classifier, AUC statistics for AtheroRisk-integrated system was higher (AUC = 0.99,p-value<0.001) compared to AtheroRisk-conventional (AUC = 0.63,p-value<0.001). CONCLUSION: The AtheroRisk-integrated ML system outperforms the AtheroRisk-conventional ML system using RF classifier.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Aprendizado de Máquina , Medição de Risco/métodos , Acidente Vascular Cerebral/prevenção & controle , Ultrassonografia/métodos , Seguimentos , Humanos , Fenótipo , Estudos Retrospectivos , Fatores de Risco
11.
Angiology ; 71(10): 920-933, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32696658

RESUMO

The objectives of this study are to (1) examine the "10-year cardiovascular risk" in the common carotid artery (CCA) versus carotid bulb using an integrated calculator called "AtheroEdge Composite Risk Score 2.0" (AECRS2.0) and (2) evaluate the performance of AECRS2.0 against "conventional cardiovascular risk calculators." These objectives are met by measuring (1) image-based phenotypes and AECRS2.0 score computation and (2) performance evaluation of AECRS2.0 against 12 conventional cardiovascular risk calculators. The Asian-Indian cohort (n = 379) with type 2 diabetes mellitus (T2DM), chronic kidney disease (CKD), or hypertension were retrospectively analyzed by acquiring the 1516 carotid ultrasound scans (mean age: 55 ± 10.1 years, 67% males, ∼92% with T2DM, ∼83% with CKD [stage 1-5], and 87.5% with hypertension [stage 1-2]). The carotid bulb showed a higher 10-year cardiovascular risk compared to the CCA by 18% (P < .0001). Patients with T2DM and/or CKD also followed a similar trend. The carotid bulb demonstrated a superior risk assessment compared to CCA in patients with T2DM and/or CKD by showing: (1) ∼13% better than CCA (0.93 vs 0.82, P = .0001) and (2) ∼29% better compared with 12 types of risk conventional calculators (0.93 vs 0.72, P = .06).


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Espessura Intima-Media Carotídea , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Hipertensão/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Adulto , Idoso , Povo Asiático , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Hipertensão/complicações , Índia , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações , Estudos Retrospectivos , Medição de Risco
12.
Int Angiol ; 39(4): 290-306, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32214072

RESUMO

BACKGROUND: Recently, a 10-year image-based integrated calculator (called AtheroEdge Composite Risk Score-AECRS1.0) was developed which combines conventional cardiovascular risk factors (CCVRF) with image phenotypes derived from carotid ultrasound (CUS). Such calculators did not include chronic kidney disease (CKD)-based biomarker called estimated glomerular filtration rate (eGFR). The novelty of this study is to design and develop an advanced integrated version called-AECRS2.0 that combines eGFR with image phenotypes to compute the composite risk score. Furthermore, AECRS2.0 was benchmarked against QRISK3 which considers eGFR for risk assessment. METHODS: The method consists of three major steps: 1) five, current CUS image phenotypes (CUSIP) measurements using AtheroEdge system (AtheroPoint, CA, USA) consisting of: average carotid intima-media thickness (cIMTave), maximum cIMT (cIMTmax), minimum cIMT (cIMTmin), variability in cIMT (cIMTV), and total plaque area (TPA); 2) five, 10-year CUSIP measurements by combining these current five CUSIP with 11 CCVRF (age, ethnicity, gender, body mass index, systolic blood pressure, smoking, carotid artery type, hemoglobin, low-density lipoprotein cholesterol, total cholesterol, and eGFR); 3) AECRS2.0 risk score computation and its comparison to QRISK3 using area-under-the-curve (AUC). RESULTS: South Asian-Indian 339 patients were retrospectively analyzed by acquiring their left/right common carotid arteries (678 CUS, mean age: 54.25±9.84 years; 75.22% males; 93.51% diabetic with HbA1c ≥6.5%; and mean eGFR 73.84±20.91 mL/min/1.73m2). The proposed AECRS2.0 reported higher AUC (AUC=0.89, P<0.001) compared to QRISK3 (AUC=0.51, P<0.001) by ~74% in CKD patients. CONCLUSIONS: An integrated calculator AECRS2.0 can be used to assess the 10-year CVD/stroke risk in patients suffering from CKD. AECRS2.0 was much superior to QRISK3.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Biomarcadores , Doenças Cardiovasculares/diagnóstico por imagem , Espessura Intima-Media Carotídea , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/diagnóstico , Estudos Retrospectivos
13.
Angiology ; 71(6): 520-535, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32180436

RESUMO

We evaluated the association between automatically measured carotid total plaque area (TPA) and the estimated glomerular filtration rate (eGFR), a biomarker of chronic kidney disease (CKD). Automated average carotid intima-media thickness (cIMTave) and TPA measurements in carotid ultrasound (CUS) were performed using AtheroEdge (AtheroPoint). Pearson correlation coefficient (CC) was then computed between the TPA and eGFR for (1) males versus females, (2) diabetic versus nondiabetic patients, and (3) between the left and right carotid artery. Overall, 339 South Asian Indian patients with either type 2 diabetes mellitus (T2DM) or CKD, or hypertension (stage 1 or stage 2) were retrospectively analyzed by acquiring cIMTave and TPA measurements of their left and right common carotid arteries (CCA; total CUS: 678, mean age: 54.2 ± 9.8 years; 75.2% males; 93.5% with T2DM). The CC between TPA and eGFR for different scenarios were (1) for males and females -0.25 (P < .001) and -0.35 (P < .001), respectively; (2) for T2DM and non-T2DM -0.26 (P < .001) and -0.49 (P = .02), respectively, and (3) for left and right CCA -0.25 (P < .001) and -0.23 (P < .001), respectively. Automated TPA is an equally reliable biomarker compared with cIMTave for patients with CKD (with or without T2DM) with subclinical atherosclerosis.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Espessura Intima-Media Carotídea , Diabetes Mellitus Tipo 2 , Taxa de Filtração Glomerular , Rim/fisiopatologia , Placa Aterosclerótica , Insuficiência Renal Crônica/fisiopatologia , Adulto , Idoso , Povo Asiático , Pressão Sanguínea , Doenças das Artérias Carótidas/etnologia , Estudos Transversais , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/etnologia , Feminino , Humanos , Hipertensão/etnologia , Hipertensão/fisiopatologia , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/etnologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
14.
Front Biosci (Landmark Ed) ; 25(6): 1132-1171, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32114427

RESUMO

Diabetes and atherosclerosis are the predominant causes of stroke and cardiovascular disease (CVD) both in low- and high-income countries. This is due to the lack of appropriate medical care or high medical costs. Low-cost 10-year preventive screening can be used for deciding an effective therapy to reduce the effects of atherosclerosis in diabetes patients. American College of Cardiology (ACC)/American Heart Association (AHA) recommended the use of 10-year risk calculators, before advising therapy. Conventional risk calculators are suboptimal in certain groups of patients because their stratification depends on (a) current blood biomarkers and (b) clinical phenotypes, such as age, hypertension, ethnicity, and sex. The focus of this review is on risk assessment using innovative composite risk scores that use conventional blood biomarkers combined with vascular image-based phenotypes. AtheroEdge™ tool is beneficial for low-moderate to high-moderate and low-risk to high-risk patients for the current and 10-year risk assessment that outperforms conventional risk calculators. The preventive screening tool that combines the image-based phenotypes with conventional risk factors can improve the 10-year cardiovascular/stroke risk assessment.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Complicações do Diabetes/diagnóstico por imagem , Complicações do Diabetes/prevenção & controle , Medicina Preventiva/métodos , Ultrassonografia/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/prevenção & controle , Análise Custo-Benefício , Humanos , Medicina Preventiva/economia , Medição de Risco/economia , Medição de Risco/métodos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Ultrassonografia/economia
15.
Int Angiol ; 38(6): 451-465, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31782286

RESUMO

Carotid intima-media thickness (cIMT) and carotid plaque (CP) currently act as risk predictors for CVD/Stroke risk assessment. Over 2000 articles have been published that cover either use cIMT/CP or alterations of cIMT/CP and additional image-based phenotypes to associate cIMT related markers with CVD/Stroke risk. These articles have shown variable results, which likely reflect a lack of standardization in the tools for measurement, risk stratification, and risk assessment. Guidelines for cIMT/CP measurement are influenced by major factors like the atherosclerosis disease itself, conventional risk factors, 10-year measurement tools, types of CVD/Stroke risk calculators, incomplete validation of measurement tools, and the fast pace of computer technology advancements. This review discusses the following major points: 1) the American Society of Echocardiography and Mannheim guidelines for cIMT/CP measurements; 2) forces that influence the guidelines; and 3) calculators for risk stratification and assessment under the influence of advanced intelligence methods. The review also presents the knowledge-based learning strategies such as machine and deep learning which may play a future role in CVD/stroke risk assessment. We conclude that both machine learning and non-machine learning strategies will flourish for current and 10-year CVD/Stroke risk prediction as long as they integrate image-based phenotypes with conventional risk factors.


Assuntos
Aterosclerose/diagnóstico , Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea/normas , Placa Aterosclerótica/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Doenças Cardiovasculares/etiologia , Humanos , Medição de Risco , Fatores de Risco , Sociedades Médicas , Acidente Vascular Cerebral/etiologia , Estados Unidos
16.
Cardiovasc Diagn Ther ; 9(5): 420-430, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31737514

RESUMO

BACKGROUND: Most cardiovascular (CV)/stroke risk calculators using the integration of carotid ultrasound image-based phenotypes (CUSIP) with conventional risk factors (CRF) have shown improved risk stratification compared with either method. However such approaches have not yet leveraged the potential of machine learning (ML). Most intelligent ML strategies use follow-ups for the endpoints but are costly and time-intensive. We introduce an integrated ML system using stenosis as an endpoint for training and determine whether such a system can lead to superior performance compared with the conventional ML system. METHODS: The ML-based algorithm consists of an offline and online system. The offline system extracts 47 features which comprised of 13 CRF and 34 CUSIP. Principal component analysis (PCA) was used to select the most significant features. These offline features were then trained using the event-equivalent gold standard (consisting of percentage stenosis) using a random forest (RF) classifier framework to generate training coefficients. The online system then transforms the PCA-based test features using offline trained coefficients to predict the risk labels on test subjects. The above ML system determines the area under the curve (AUC) using a 10-fold cross-validation paradigm. The above system so-called "AtheroRisk-Integrated" was compared against "AtheroRisk-Conventional", where only 13 CRF were considered in a feature set. RESULTS: Left and right common carotid arteries of 202 Japanese patients (Toho University, Japan) were retrospectively examined to obtain 395 ultrasound scans. AtheroRisk-Integrated system [AUC =0.80, P<0.0001, 95% confidence interval (CI): 0.77 to 0.84] showed an improvement of ~18% against AtheroRisk-Conventional ML (AUC =0.68, P<0.0001, 95% CI: 0.64 to 0.72). CONCLUSIONS: ML-based integrated model with the event-equivalent gold standard as percentage stenosis is powerful and offers low cost and high performance CV/stroke risk assessment.

18.
Curr Atheroscler Rep ; 21(7): 25, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31041615

RESUMO

PURPOSE OF REVIEW: Cardiovascular disease (CVD) and stroke risk assessment have been largely based on the success of traditional statistically derived risk calculators such as Pooled Cohort Risk Score or Framingham Risk Score. However, over the last decade, automated computational paradigms such as machine learning (ML) and deep learning (DL) techniques have penetrated into a variety of medical domains including CVD/stroke risk assessment. This review is mainly focused on the changing trends in CVD/stroke risk assessment and its stratification from statistical-based models to ML-based paradigms using non-invasive carotid ultrasonography. RECENT FINDINGS: In this review, ML-based strategies are categorized into two types: non-image (or conventional ML-based) and image-based (or integrated ML-based). The success of conventional (non-image-based) ML-based algorithms lies in the different data-driven patterns or features which are used to train the ML systems. Typically these features are the patients' demographics, serum biomarkers, and multiple clinical parameters. The integrated (image-based) ML-based algorithms integrate the features derived from the ultrasound scans of the arterial walls (such as morphological measurements) with conventional risk factors in ML frameworks. Even though the review covers ML-based system designs for carotid and coronary ultrasonography, the main focus of the review is on CVD/stroke risk scores based on carotid ultrasound. There are two key conclusions from this review: (i) fusion of image-based features with conventional cardiovascular risk factors can lead to more accurate CVD/stroke risk stratification; (ii) the ability to handle multiple sources of information in big data framework using artificial intelligence-based paradigms (such as ML and DL) is likely to be the future in preventive CVD/stroke risk assessment.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/prevenção & controle , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Ultrassonografia/métodos , Algoritmos , Doenças das Artérias Carótidas/complicações , Aprendizado Profundo , Humanos , Infarto do Miocárdio/etiologia , Placa Aterosclerótica/complicações , Medição de Risco/métodos , Medição de Risco/tendências , Fatores de Risco , Acidente Vascular Cerebral/etiologia
19.
Med Biol Eng Comput ; 57(7): 1553-1566, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30989577

RESUMO

Today, the 10-year cardiovascular risk largely relies on conventional cardiovascular risk factors (CCVRFs) and suffers from the effect of atherosclerotic wall changes. In this study, we present a novel risk calculator AtheroEdge Composite Risk Score (AECRS1.0), designed by fusing CCVRF with ultrasound image-based phenotypes. Ten-year risk was computed using the Framingham Risk Score (FRS), United Kingdom Prospective Diabetes Study 56 (UKPDS56), UKPDS60, Reynolds Risk Score (RRS), and pooled composite risk (PCR) score. AECRS1.0 was computed by measuring the 10-year five carotid phenotypes such as IMT (ave., max., min.), IMT variability, and total plaque area (TPA) by fusing eight CCVRFs and then compositing them. AECRS1.0 was then benchmarked against the five conventional cardiovascular risk calculators by computing the receiver operating characteristics (ROC) and area under curve (AUC) values with a 95% CI. Two hundred four IRB-approved Japanese patients' left/right common carotid arteries (407 ultrasound scans) were collected with a mean age of 69 ± 11 years. The calculators gave the following AUC: FRS, 0.615; UKPDS56, 0.576; UKPDS60, 0.580; RRS, 0.590; PCRS, 0.613; and AECRS1.0, 0.990. When fusing CCVRF, TPA reported the highest AUC of 0.81. The patients were risk-stratified into low, moderate, and high risk using the standardized thresholds. The AECRS1.0 demonstrated the best performance on a Japanese diabetes cohort when compared with five conventional calculators. Graphical abstract AECRS1.0: Carotid ultrasound image phenotype-based 10-year cardiovascular risk calculator. The figure provides brief overview of the proposed carotid image phenotype-based 10-year cardiovascular risk calculator called AECRS1.0. AECRS1.0 was also benchmarked against five conventional cardiovascular risk calculators (Framingham Risk Score (FRS), United Kingdom Prospective Diabetes Study 56 (UKPDS56), UKPDS60, Reynolds Risk Score (RRS), and pooled composite risk (PCR) score).


Assuntos
Doenças Cardiovasculares/etiologia , Artérias Carótidas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Artérias Carótidas/patologia , Espessura Intima-Media Carotídea , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Fatores de Risco
20.
Comput Biol Med ; 108: 182-195, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31005010

RESUMO

PURPOSE: Conventional cardiovascular risk factors (CCVRFs) and carotid ultrasound image-based phenotypes (CUSIP) are independently associated with long-term risk of cardiovascular (CV) disease. In this study, 26 cardiovascular risk (CVR) factors which consisted of a combination of CCVRFs and CUSIP together were ranked. Further, an optimal risk calculator using AtheroEdge composite risk score (AECRS1.0) was designed and benchmarked against seven conventional CV risk (CVR) calculators. METHODS: Two types of ranking were performed: (i) ranking of 26 CVR factors and (ii) ranking of eight types of 10-year risk calculators. In the first case, multivariate logistic regression was used to compute the odds ratio (OR) and in the second, receiver operating characteristic curves were used to evaluate the performance of eight types of CVR calculators using SPSS23.0 and MEDCALC12.0 with validation against STATA15.0. RESULTS: The left and right common carotid arteries (CCA) of 202 Japanese patients were examined to obtain 404 ultrasound scans. CUSIP ranked in the top 50% of the 26 covariates. Intima-media thickness variability (IMTV) and IMTV10yr were the most influential carotid phenotypes for left CCA (OR = 250, P < 0.0001 and OR = 207, P < 0.0001 respectively) and right CCA (OR = 1614, P < 0.0001 and OR = 626, P < 0.0001 respectively). However, for the mean CCA, AECRS1.0 and AECRS1.010yr reported the most highly significant OR among all the CVR factors (OR = 1.073, P < 0.0001 and OR = 1.104, P < 0.0001). AECRS1.010yr also reported highest area-under-the-curve (AUC = 0.904, P < 0.0001) compared to seven types of conventional calculators. Age and glycated haemoglobin reported highest OR (1.96, P < 0.0001 and 1.05, P = 0.012) among all other CCVRFs. CONCLUSION: AECRS1.010yr demonstrated the best performance due to presence of CUSIP and ranked at the first place with highest AUC.


Assuntos
Artéria Carótida Primitiva , Modelos Cardiovasculares , Acidente Vascular Cerebral , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/metabolismo , Artéria Carótida Primitiva/fisiopatologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Medição de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA