Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 12(20)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37892704

RESUMO

Aims-Electrocardiography (ECG) and echocardiographic left atrial (LA) parameters may be helpful to assess the risk of atrial fibrillation (AF) in embolic stroke of unknown etiology (ESUS) and could therefore guide intensity of ECG monitoring. Methods-1153 consecutive patients with ischemic stroke or transient ischemic attack (TIA) were analyzed. An internal loop recorder (ILR) was implanted in 104 consecutive patients with ESUS. Multiple morphologic P-wave parameters in baseline 12-channel ECG and echocardiographic LA parameters were measured and analyzed in patients with and without ILR-detected AF. Using logistic regression, we evaluated the predictive value of several ECG parameters and LA dimensions on the occurrence of AF. Results-In 20 of 104 (19%) patients, AF was diagnosed by ILR during a mean monitoring time of 575 (IQR 470-580) days. Patients with AF were significantly older (72 (67-75) vs. 60 (52-72) years; p = 0.001) and premature atrial contractions (PAC) were more frequently observed (40% vs. 2%; p < 0.001) during baseline ECG. All morphologic P-wave parameters did not show a significant difference between groups. There was a non-significant trend towards a larger LA volume index (31 (24-36) vs. 29 (25-37) mL/m2; p = 0.09) in AF patients. Conclusions-Age and PAC are independently associated with incident AF in ESUS and could be used as markers for selecting patients that may benefit from more extensive rhythm monitoring or ILR implantation. In our consecutive cohort of patients with ESUS, neither morphological P-wave parameters nor LA size were predictive of AF.

2.
Circ Arrhythm Electrophysiol ; 16(4): e011547, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36912137

RESUMO

BACKGROUND: Thermal left atrial ablation can cause bronchial damage. Pulsed field ablation (PFA) is a novel, nonthermal ablation modality for paroxysmal atrial fibrillation. We report on bronchial effects after pulmonary vein isolation using PFA for paroxysmal atrial fibrillation. METHODS: A computed tomography scan showing the respiratory tract adjacent to the left atrial was obtained. Oral anticoagulation was interrupted on procedure day. Peri-procedurally, patients received heparin with an activated clotting time goal of >350 seconds. All pulmonary veins were individually isolated with a 13F steerable sheath and a pentaspline PFA catheter using either a straight-tip or J-tip guide wire. The J-tip guide wire patients were added to test the hypothesis that the straight-tip guidewire was associated with bleeding complications. One day afterward, bronchoscopy was performed. Serial hemoglobin levels were measured during 30-day follow-up. RESULTS: In 2 series of 30 patients, PFA was performed, with all pulmonary veins acutely isolated. Clinical course was uneventful, no patient had chest discomfort, coughing, or hemoptysis. All patients underwent uncomplicated bronchoscopy, without thermal lesions or ulcers. In 12 out of 30 (40%) straight-tip guide wire patients, small amounts of old blood without active bleeding were seen in multiple segments. All hemoglobin levels remained clinically stable. At 30-day follow-up, all patients were asymptomatic. CONCLUSIONS: Pulmonary vein isolation using PFA for paroxysmal atrial fibrillation does not cause thermal lesions in the bronchial system. Use of a straight-tip, extrastiff guide wire for the over-the-wire PFA catheter can lead to asymptomatic bleeding in the bronchial system without clinical relevance at 30-day follow-up, opposite to use of a J-tip guide wire.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Brônquios , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Hemoglobinas , Resultado do Tratamento
3.
Heart Rhythm ; 19(11): 1813-1818, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35718318

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel, nonthermal ablation modality that can ablate myocardial tissue with minimal effects on surrounding tissue. Preclinical data show an absence of cerebral emboli after extensive PFA. However, clinical data on silent cerebral lesions (SCLs) and/or silent cerebral events (SCEs) after PFA are lacking. OBJECTIVES: The purpose of this study was to investigate the occurrence of neurological deficits and SCL and/or SCE after PFA in paroxysmal atrial fibrillation (AF) using National Institutes of Health Stroke Scale (NIHSS) scores and magnetic resonance imaging (MRI). METHODS: In patients with symptomatic paroxysmal AF, pulmonary vein isolation (PVI) using PFA was performed. NIHSS scores were assessed before and 2 days and 30 days after PVI. One day after PVI, patients underwent cerebral 1.5-T MRI scanning using diffusion-weighted imaging and fluid-attenuated inversion recovery sequences to document the occurrence of SCL/SCE. RESULTS: PFA was performed in 30 patients (age 63 ± 10 years). No patient showed neurological deficits. All NIHSS scores showed the minimum value of 0. Cerebral MRI scans were normal in 29 of 30 patients (97%). In 1 patient (3%), a single 7-mm cerebellar lesion was observed. Forty days after the procedure, follow-up cerebral MRI scan showed complete regression of the lesion. CONCLUSION: In patients treated with PFA for symptomatic paroxysmal AF, the incidence of MRI-detected asymptomatic thromboembolic cerebral events or lesions was as low as 3%. No neurological deficits occurred in any of the patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
4.
Europace ; 24(7): 1084-1092, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35513354

RESUMO

AIMS: Catheter ablation for atrial fibrillation (AF) using thermal energy can cause collateral damage. Pulsed field ablation (PFA) is a novel non-thermal energy source. Few small clinical studies have been published. We report on the first 'real-world' experience with pulmonary vein isolation (PVI) using PFA for paroxysmal AF (PAF). METHODS AND RESULTS: Pre- and post-ablation, phrenic nerve function was assessed. After high-density left atrial (LA) bipolar voltage mapping, all PVs were individually isolated using a 13 Fr steerable sheath and a pentaspline PFA over-the-wire catheter. After ablation, bipolar voltage mapping was repeated to assess lesion formation. In 30 PAF patients (mean 63 years; 53% female), uncomplicated PFA was performed, with all PVs acutely isolated. The median procedure time was 116 min. The median PFA catheter LA dwell time was 29 min. The median fluoroscopy time was 26 min. In one patient with roof-dependent flutter, a roof line was intentionally created. In two patients, unintentional bidirectional mitral isthmus block was created. There was no phrenic nerve or oesophageal damage. In one patient, pericardial drainage after cardiac tamponade was performed. In-hospital stay and 30-day follow-up were uneventful. After 90 days, 97% of patients were in sinus rhythm. CONCLUSION: PVI using PFA for PAF in a 'real-world' setting appears to be safe and feasible in this small patient cohort. Procedure times are homogeneous, and LA dwell time is short. Atrial ablation lines can easily be created. Unintentional ablation of atrial tissue can occur, accurate catheter alignment to the PV ostium and axis should be ensured.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Átrios do Coração , Humanos , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
J Clin Med ; 11(6)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35329960

RESUMO

BACKGROUND: Injectable cardiac monitors (ICMs) are leadless subcutaneous devices for long-term monitoring of arrhythmias. The BIOTRONIK BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector, and simplified implantation technique. METHODS: R-wave amplitude was recorded immediately after implantation, the day after implantation, and after 3 months. Follow-up was scheduled after 3 months or after an event. All data from the ICM were retrieved. The anatomical position of the ICM was determined post-implantation and after 3 months. A patient questionnaire was conducted after 3 months. RESULTS: In 36 patients (mean age 67 ± 13 years; 40% male) an ICM was inserted. Six patients were not included in the final analysis. The median time from skin cut to wound closure was 6 [IQR 5-7] minutes. Mean R-wave amplitude increased over time (0.73 ± 32 mV vs. 0.78 ± 0.38 mV vs. 0.81 ± 0.39 mV; p = ns). Three months after implantation, the ICM was in an anatomically stable position. In 14 (47%) patients, true episodes were detected. False arrhythmia alerts were detected in 13 (43%) patients. The total number of false detections was low, and the patient satisfaction rate was high. CONCLUSION: Implantation of the novel BIOMONITOR III is fast and uncomplicated; its sensing characteristics are excellent and improve over time, and patient satisfaction is high.

6.
Herzschrittmacherther Elektrophysiol ; 33(1): 12-18, 2022 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-34997292

RESUMO

The ablation of cardiac arrhythmias is now standard therapy in invasive electrophysiology with a focus on atrial fibrillation due to its high prevalence. Thermal energy sources such as radiofrequency or cryoablation are the most commonly used techniques to date. Due to limitations in terms of effectiveness and safety because of possible indiscriminate tissue destruction, ablation using pulsed field ablation (PFA) can be a safe and effective alternative to thermal ablation techniques. This is a nonthermal form of energy that creates effective myocardial lesions by means of irreversible electroporation by generating short, high-energy electrical impulses. Preliminary data show high effectiveness with a low complication rate. Myocardial tissue shows a high specificity while sparing surrounding structures such as the esophagus, the phrenic nerve and surrounding vascular structures. Therefore, irreversible electroporation is a very promising technique and has the potential to become the perfect form of energy for many catheter ablations and especially for pulmonary vein isolation. In this article we provide an overview of the current status of PFA as well as an outlook on future fields of treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Nervo Frênico/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
Diagnostics (Basel) ; 12(1)2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35054205

RESUMO

PURPOSE: To evaluate retinal and optic nerve head (ONH) perfusion in patients with atrial fibrillation (AF) before and after catheter ablation of AF with pulmonary vein isolation (PVI). METHODS: 34 eyes of 34 patients with AF and 35 eyes of 35 healthy subjects were included in this study. Flow density data were obtained using spectral-domain OCT-A (RTVue XR Avanti with AngioVue, Optovue, Inc, Fremont, California, USA). The data of the superficial and deep vascular layers of the macula and the ONH (radial peripapillary capillary network, RPC) before and after PVI were extracted and analysed. RESULTS: The flow density in the superficial OCT-angiogram (whole en face) and the ONH (RPC) in patients with AF was significantly lower compared to healthy controls (OCT-A superficial: study group: 48.77 (45.19; 52.12)%; control group: 53.01 (50.00; 54.25)%; p < 0.001; ONH: study group: 51.82 (48.41; 54.03)%; control group: 56.00 (54.35; 57.70)%; p < 0.001;). The flow density in the ONH (RPC) improved significantly in the study group following PVI (before: 51.82 (48.41; 54.03)%; after: 52.49 (50.34; 55.62)%; p = 0.007). CONCLUSIONS: Patients with AF showed altered ocular perfusion as measured using OCTA when compared with healthy controls. Rhythm control using PVI significantly improved ocular perfusion as measured using OCT-A. Non-contact imaging using OCTA provides novel information about the central global microperfusion of patients with AF.

8.
Clin Cardiol ; 43(12): 1423-1427, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32865252

RESUMO

BACKGROUND: Ablation emerged as first line therapy in the treatment of various arrhythmias. Nevertheless, in older patients (pts), decision is often made pro drug treatment as more complications and less benefit are suspected. HYPOTHESIS: We hypothesized that different kind of ablations can be performed safely regardless of the pts age. METHODS: We enrolled all pts aged >80 years (yrs) who underwent ablation for three different arrhythmias (atrial flutter [AFL], atrioventricular nodal re-entry tachycardia [AVNRT], ventricular tachycardia [VT]) between August 2002 and December 2018. Procedural data and outcome were compared with matched groups aged 60 to 80 years and 40 to 60 years, respectively. Periprocedural and in-hospital complications were analyzed. RESULTS: The analysis included 1191 patients (397 pts per group: 63% AFL, 23% AVNRT, 14% VT) who underwent ablation. Acute success was high in all types of arrhythmias irrespective of age (>80, 60-80, 40-60 years: AFL 97%/98%/98%, AVNRT 97%/95%/97%, VT 82%/86%/93%). Rate of periprocedural complications were similar in all groups treated for AFL and AVNRT. For VT ablations significant differences were noted between pts > 80 or 60 to 80 years and those aged 40-60 years (16.1%/14.3%/3.6%). Most complications were infections and groin haematoma. No strokes, iatrogenic atrioventricular blocks and deaths related to the ablation occurred. CONCLUSION: Ablation appears safe in pts > 80 years. Success rates were comparable to matched younger cohorts. A significant difference was observed for VT patients.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA