Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 59(12): 1972-1980, 2021 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-34496163

RESUMO

OBJECTIVES: Macrotroponin is due to cardiac troponin (cTn) binding to endogenous cTn autoantibodies. While previous studies showed a high incidence of macrotroponin affecting cTnI assays, reports of macrotroponin T, particularly without cTnI reactivity, have been rare. Although the clinical significance of macrotroponin is not fully understood, macroenzymes and complexes are recognised to cause confusion in interpretation of laboratory results. The potential for adverse clinical consequences due to misinterpretation of affected results is very high. METHODS: We describe four cases of macrotroponin T with persistently low high sensitivity cTnT (hs-cTnT) by the 9 min compared to the 18 min variant of the assay. Three cases were serendipitously identified due to the use of a lot number of Roche hs-cTnT affected by non-reproducible results, necessitating measurement of cTnT in duplicate. We identified and characterised these macrotroponin specimens by immunoglobulin depletion (Protein A and PEG precipitation), mixing studies with EDTA and recombinant cTnT. RESULTS: In cases of macro-cTnT, a lower result occurred on the hs-cTnT using the 9 min compared to 18 min variant assay (ratio of 9-18 min hs-cTnT <0.80). Mixing studies with recombinant cTnT or EDTA demonstrated a difference in recovery vs. controls. One of these patients demonstrated a high molecular weight complex for cTnI and cTnT demonstrating a macrocomplex involving both cTn. This patient demonstrated a rise and fall in cTn when measured by several commercial assays consistent with genuine acute cardiac injury. CONCLUSIONS: We identified several cases of macro-cTnT and described associated clinical and biochemical features.


Assuntos
Autoanticorpos , Bioensaio , Troponina T , Autoanticorpos/imunologia , Bioensaio/normas , Biomarcadores , Humanos , Troponina I/análise , Troponina T/análise , Troponina T/imunologia
2.
Pathology ; 53(7): 860-866, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34272050

RESUMO

Macrotroponin is a complex formed between endogenous cardiac troponin autoantibodies and circulating cardiac troponin (cTn). It is a recognised cause of discrepancy between current high sensitivity troponin (hs-cTn) assays; and immunoglobulin-bound (macrotroponin) and unbound cTn can coexist in varying proportions in the acute setting. Increasingly it is considered when laboratory cTn results do not match a patient's clinical picture. However, despite the better understanding of macrotroponin as an analytical interference, its clinical significance remains unclear. The aim of this study was to determine the potential impact of macrotroponin on the use of cTn as a long-term prognostic marker. We repeated cTnI testing after polyethylene glycol (PEG) precipitation on consecutive participants (n=159) with a first elevated cTn above 0.2 µg/L during their hospital admission episode. Because this paper is looking at outcomes in years, the initial data were generated at a time when non-hs-cTn assays were in use. We divided the cohort into two groups based on an exploratory PEG recovery cut-off of <34.6% to indicate the presence of possible macrotroponin and compared the overall and cardiovascular related mortality. The median follow-up time for the overall cohort was 8.35 years (8.32-8.40 interquartile range) with no difference between the two groups. The overall median survival was 8.1 years. Our findings indicate a hazard ratio of 0.54 (0.32-0.91 95% CI) for all-cause mortality and 0.48 (0.24-0.95) for cardiovascular mortality in patients with possible macrotroponin compared to those patients with troponin elevation without evidence of macrotroponin, after adjustment for common cardiovascular disease risk factors. Furthermore, an association was observed between PEG% recovery and all-cause mortality (p<0.05). This study showed that patients with macrotroponin have comparatively favourable long-term all-cause and cardiovascular mortality in a cohort of patients with elevated troponin. We illustrate the importance of recognising cTn results as being a summation of heterogeneous components, including those bound to antibodies, and the potential role of macrotroponin to further improve our interpretation and use of cTn as a biomarker.


Assuntos
Biomarcadores/análise , Doenças Cardiovasculares/diagnóstico , Troponina I/análise , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/patologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
3.
J Immunother ; 44(4): 162-163, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33416262

RESUMO

Checkpoint inhibitor-associated myocarditis (ir-myocarditis) and myositis (ir-myositis) may occur concurrently among patients on checkpoint inhibitor immunotherapy. While cardiac-specific troponin I (cTnI) and troponin T (cTnT) are regarded to have similar sensitivities and specificities in conditions such as acute coronary syndrome, the cardiac specificity of cTnT has been challenged following observation that patients with neuromuscular diseases, including myositis, may have elevated cTnT without apparent clinical evidence of myocardial injury. Consequently, in the context of concurrent ir-myositis, cTnI may be a more appropriate biomarker for diagnosing and monitoring ir-myocarditis. To illustrate this point, we report a case of a patient with severe ir-myositis while on adjuvant programmed cell death protein 1 inhibitor immunotherapy for stage III melanoma, with accompanying elevation in cTnT.


Assuntos
Miocardite/metabolismo , Miosite/metabolismo , Troponina I/metabolismo , Troponina T/metabolismo , Idoso , Biomarcadores/metabolismo , Feminino , Humanos
4.
Clin Biochem ; 85: 43-48, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32861681

RESUMO

INTRODUCTION: Macrotroponin is a complex formed between endogenous cardiac troponin autoantibodies (cTnAABs) and circulating cardiac troponin (cTn). The potential effect of macrotroponin on current high sensitivity cTn assays has not been fully explored but has recently been identified as a major cause of discrepancy in cTn results between assays. In this study we investigated the effects of mixing troponin (cTn) standards to specimens with and without macrotroponin. METHOD: Macrotroponin was identified in specimens by a recovery of cTnI < 40% following protein A immunoglobulin depletion. Troponin standards containing cTn-IC and cTn-TIC complexes were mixed with serum samples, with (n = 20) and without (n = 10) the presence of macrotroponin. Specimens were tested for cTn before and after mixing by three commercially available high sensitivity cTn assays. Gel filtration chromatography was carried out on five specimens with macrotroponin and each fraction was analzyed by multiple cTn assays. FINDINGS: Following mixing with cTn-TIC standard, all specimens with macrotroponin had a markedly reduced absolute increase in cTnI, indicating negative analytical interference due to macrotroponin. Following mixing with the cTn-IC standard, specimens with macrotroponin demonstrated highly variable changes in cTnI, suggesting significant heterogeneity in macrotroponin complex reactivity between individuals. When the ratio of change, calculated by dividing the absolute change between two cTn assays, was compared between specimens with and without macrotroponin, significant differences were observed (p < 0.001). These findings were supported by variable migration of peak cTn activity on gel filtration chromatography. CONCLUSION: Macrotroponin leads to assay dependent analytical interference affecting current high sensitivity troponin I assays. Furthermore, endogenously occurring cTnAABs are conformationally specific and the analytical effects vary between assays and individuals.


Assuntos
Autoanticorpos/metabolismo , Troponina I/metabolismo , Reações Antígeno-Anticorpo , Autoanticorpos/sangue , Cromatografia em Gel , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Kit de Reagentes para Diagnóstico , Troponina I/sangue , Troponina I/imunologia
5.
Clin Chem ; 66(3): 445-454, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32031592

RESUMO

BACKGROUND: Despite well-described analytical effects of autoantibodies against cardiac troponin (cTn) I on experimental assays, no study has systematically examined their impact on cTn assays in clinical use. We determined the effects of endogenous antibodies on 5 different cTnI assays and a cTnT assay. METHODS: cTn was measured by 6 methods: Siemens hs-cTnI Centaur, Siemens hs-cTnI Vista, Abbott hs-cTnI Architect, Beckman hs-cTnI Access, Beckman cTnI Access, and Roche hs-cTnT Elecsys. Measurements were repeated on 5 assays (all except Siemens hs-cTnI Vista) following immunoglobulin depletion by incubation with protein A. Low recovery of cTnI (<40%) following immunoglobulin depletion was considered positive for macro-cTnI. Protein A findings were validated by gel filtration chromatography and polyethylene glycol precipitation. RESULTS: In a sample of 223 specimens selected from a community laboratory that uses the Siemens hs-cTnI Centaur assay and from which cTn was requested, 76% of samples demonstrated increased cTnI (median, 88 ng/L; interquartile range, 62-204 ng/L). Macro-cTnI was observed in 123 (55%) of the 223 specimens. Comparisons of cTnI assays markedly improved once patients with macro-cTnI were removed. Passing-Bablok regression analysis between hs-cTnI assays demonstrated different slopes for patients with and without macro-cTnI. In patients with macro-cTnI, 89 (72%) showed no effect on the recovery of cTnT, whereas 34 (28%) had reduced recovery of cTnT. The proportion of results above the manufacturers' 99th percentile varied with the cTn assay and macro-cTnI status. CONCLUSION: We suggest that the observed discrepancy between hs-cTnI assays may be attributed in part to the presence of macro-cTnI.


Assuntos
Bioensaio/métodos , Troponina I/sangue , Troponina T/sangue , Autoanticorpos/imunologia , Autoanticorpos/metabolismo , Precipitação Química , Cromatografia em Gel , Humanos , Imunoglobulinas/imunologia , Imunoglobulinas/metabolismo , Kit de Reagentes para Diagnóstico , Análise de Regressão , Proteína Estafilocócica A/metabolismo , Troponina I/isolamento & purificação , Troponina T/isolamento & purificação
7.
Ann Clin Biochem ; 52(Pt 2): 288-92, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25261566

RESUMO

Whole blood, serum or plasma chloride is almost exclusively measured by potentiometry with an ion-selective chloride electrode which utilizes membrane selectivity to chloride ions. Other anions such as bromide, iodide and thiosulphate can interfere but usually are not present in high enough concentration to cause significant cross reactivity. A patient from our burns unit had serial chloride measurements on a Radiometer ABL800 blood gas analyser. The results were higher in contrast to plasma measurements on the Abbott Architect Ci8200, which were within reference intervals and in line with the patient's pathophysiological status. This indicated a likely interference with the blood gas analyser chloride estimation. The chloride results on the ABL800 for 3rd, 4th and 5th day after the burn accident were 170, 137 and 119 mmol/L. Corresponding plasma chloride results on the Ci8200 were all around 105 mmol/L. Nitrate was found to be markedly elevated in these samples, and the results were 6.7, 4.9 and 1.1 mmol/L, respectively (reference limit < 0.08 mmol/L). To further demonstrate nitrate was the causative agent, pooled plasma spiked with 7 mmol/L of sodium nitrate caused a rise in the ABL800 chloride from 105 to 202 mmol/L. Later we confirmed that the patient was topically medicated with cerium nitrate cream (Flammacerium®, Sinclair IS Pharma, UK) for his burns. In summary, the results clearly indicated nitrate was the interferent with the ABL800 chloride estimation and the source was the topical burns cerium nitrate cream.


Assuntos
Anti-Infecciosos Locais/farmacocinética , Queimaduras/tratamento farmacológico , Cério/farmacocinética , Nitratos/sangue , Sulfadiazina de Prata/farmacocinética , Creme para a Pele/farmacocinética , Regulação para Cima , Administração Cutânea , Anti-Infecciosos Locais/administração & dosagem , Anti-Infecciosos Locais/uso terapêutico , Queimaduras/sangue , Queimaduras/terapia , Cério/administração & dosagem , Cério/uso terapêutico , Criança , Cloro/sangue , Terapia Combinada , Combinação de Medicamentos , Reações Falso-Positivas , Evolução Fatal , Humanos , Masculino , Sulfadiazina de Prata/administração & dosagem , Sulfadiazina de Prata/uso terapêutico , Absorção Cutânea , Creme para a Pele/uso terapêutico
8.
Ann Clin Biochem ; 49(Pt 6): 606-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23038701

RESUMO

BACKGROUND: A failure of urine ammonium to increase during acidosis indicates impaired renal acidification, and the urinary ammonium concentration is therefore a useful investigation in determining the cause of a metabolic acidosis. However, urine ammonium measurements are not widely available in routine diagnostic laboratories. This has led to the use of urine anion or osmolar gaps, which are unsatisfactory as surrogates for urine ammonium measurement. METHODS: We evaluated the adaptation of two widely available automated plasma ammonium assays for measurement of urinary ammonium. RESULTS: Both assays showed good recovery and linearity in urine samples spiked with ammonium chloride, and acceptable precision. Urine ammonium concentrations estimated from urinary anion and osmolar gaps showed poor agreement with measured urine ammonium concentrations. CONCLUSIONS: Direct urine ammonium measurements are easily performed with modern autoanalysers by simple adaptation of routine plasma ammonium assays. The use of urine anion and osmolar gaps should be abandoned where direct measurement is available.


Assuntos
Compostos de Amônio Quaternário/urina , Urinálise/métodos , Urinálise/normas , Ânions/análise , Humanos , Concentração Osmolar , Compostos de Amônio Quaternário/sangue
10.
Nephrology (Carlton) ; 11(4): 367-71, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16889578

RESUMO

AIMS: The aims of the present audit were to determine the prevalence of gout in renal transplant recipients in Canterbury, New Zealand, to identify risk factors for gout, and to assess the range of treatments used, their efficacy and complications. In addition, the authors wished to assess the impact of post-renal transplant gout on the patient. METHODS: Patients with post-transplantation gout were identified from the Christchurch Hospital Nephrology database. For each patient with gout a post-renal transplantation recipient without gout post transplant was found matched for age, sex and date of transplant. Case notes were audited and patients interviewed. RESULTS: In total, 47/202 (23%) living renal transplant recipients had gout post transplant. Those patients with gout were more likely to be taking a loop diuretic (68%vs 34%, P < 0.001), to have a higher serum urate and impaired renal function and to have had gout prior to the transplant. Of those patients who developed gout post transplant 70% had an attack at least every 3 months. Of those who returned to work post transplant 48% required time off work because of gout. CONCLUSION: out is an important problem in the post-transplant population causing significant morbidity and time off work. Diuretics, impaired renal function, gout prior to transplantation and hyperuricaemia are important risk factors. The need for diuretic therapy should be kept under review in these patients. Hypouricaemic therapy should be considered early in those who develop gout post renal transplantation. Further studies are required to determine whether treatment for asymptomatic hyperuricaemia is justified.


Assuntos
Gota/etiologia , Transplante de Rim/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Gota/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA