Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Comput Assist Radiol Surg ; 19(4): 757-766, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386176

RESUMO

PURPOSE: Intracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging. METHODS: We proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter. RESULTS: The proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region. CONCLUSION: The preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.


Assuntos
Cardiologia , Insuficiência da Valva Mitral , Robótica , Humanos , Catéteres , Valva Mitral
2.
Artigo em Inglês | MEDLINE | ID: mdl-38319759

RESUMO

Endovascular intervention is a minimally invasive method for treating cardiovascular diseases. Although fluoroscopy, known for real-time catheter visualization, is commonly used, it exposes patients and physicians to ionizing radiation and lacks depth perception due to its 2D nature. To address these limitations, a study was conducted using teleoperation and 3D visualization techniques. This in-vitro study involved the use of a robotic catheter system and aimed to evaluate user performance through both subjective and objective measures. The focus was on determining the most effective modes of interaction. Three interactive modes for guiding robotic catheters were compared in the study: 1) Mode GM, using a gamepad for control and a standard 2D monitor for visual feedback; 2) Mode GH, with a gamepad for control and HoloLens providing 3D visualization; and 3) Mode HH, where HoloLens serves as both control input and visualization device. Mode GH outperformed other modalities in subjective metrics, except for mental demand. It exhibited a median tracking error of 4.72 mm, a median targeting error of 1.01 mm, a median duration of 82.34 s, and a median natural logarithm of dimensionless squared jerk of 40.38 in the in-vitro study. Mode GH showed 8.5%, 4.7%, 6.5%, and 3.9% improvements over Mode GM and 1.5%, 33.6%, 34.9%, and 8.1% over Mode HH for tracking error, targeting error, duration, and dimensionless squared jerk, respectively. To sum up, the user study emphasizes the potential benefits of employing HoloLens for enhanced 3D visualization in catheterization. The user study also illustrates the advantages of using a gamepad for catheter teleoperation, including user-friendliness and passive haptic feedback, compared to HoloLens. To further gauge the potential of using a more traditional joystick as a control input device, an additional study utilizing the Haption VirtuoseTM robot was conducted. It reveals the potential for achieving smoother trajectories, with a 38.9% reduction in total path length compared to a gamepad, potentially due to its larger range of motion and single-handed control.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA