Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 13(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38202288

RESUMO

This comprehensive review explores the role of Functional Near-Infrared Spectroscopy (fNIRS) in advancing our understanding of the visual system. Beginning with an introduction to fNIRS, we delve into its historical development, highlighting how this technology has evolved over time. The core of the review critically examines the advantages and disadvantages of fNIRS, offering a balanced view of its capabilities and limitations in research and clinical settings. We extend our discussion to the diverse applications of fNIRS beyond its traditional use, emphasizing its versatility across various fields. In the context of the visual system, this review provides an in-depth analysis of how fNIRS contributes to our understanding of eye function, including eye diseases. We discuss the intricacies of the visual cortex, how it responds to visual stimuli and the implications of these findings in both health and disease. A unique aspect of this review is the exploration of the intersection between fNIRS, virtual reality (VR), augmented reality (AR) and artificial intelligence (AI). We discuss how these cutting-edge technologies are synergizing with fNIRS to open new frontiers in visual system research. The review concludes with a forward-looking perspective, envisioning the future of fNIRS in a rapidly evolving technological landscape and its potential to revolutionize our approach to studying and understanding the visual system.

2.
Biomed J ; : 100679, 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38048990

RESUMO

The Metaverse has gained wide attention for being the application interface for the next generation of Internet. The potential of the Metaverse is growing, as Web 3·0 development and adoption continues to advance medicine and healthcare. We define the next generation of interoperable healthcare ecosystem in the Metaverse. We examine the existing literature regarding the Metaverse, explain the technology framework to deliver an immersive experience, along with a technical comparison of legacy and novel Metaverse platforms that are publicly released and in active use. The potential applications of different features of the Metaverse, including avatar-based meetings, immersive simulations, and social interactions are examined with different roles from patients to healthcare providers and healthcare organizations. Present challenges in the development of the Metaverse healthcare ecosystem are discussed, along with potential solutions including capabilities requiring technological innovation, use cases requiring regulatory supervision, and sound governance. This proposed concept and framework of the Metaverse could potentially redefine the traditional healthcare system and enhance digital transformation in healthcare. Similar to AI technology at the beginning of this decade, real-world development and implementation of these capabilities are relatively nascent. Further pragmatic research is needed for the development of an interoperable healthcare ecosystem in the Metaverse.

3.
Ophthalmol Sci ; 2(3): 100170, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36245760

RESUMO

Purpose: The impact of cataract surgery on low luminance visual acuity deficit (LLVAD) measurements was investigated by measuring the LLVAD before and after cataract surgery. Design: Prospective, longitudinal study. Participants: Patients undergoing cataract surgery. Methods: Photopic luminance (PL)-best-corrected visual acuity (BCVA) and low luminance (LL)-BCVA were obtained using the ETDRS chart. Low luminance visual acuity deficit scores were calculated by subtracting the LL-BCVA letter score from the PL-BCVA letter score. To demonstrate the reproducibility of these visual acuity measurements, we used data from drusen-only eyes previously published in the Complement Inhibition with Eculizumab for the Treatment of Nonexudative Age-Related Macular Degeneration (COMPLETE) study. The PL-BCVA, LL-BCVA, and LLVAD measurements obtained at an interval of 3 months in this cohort were used for comparison. In the current study, the impact of cataract surgery on LLVAD measurements was analyzed by comparing the PL-BCVA, LL-BCVA, and LLVAD measurements before and after cataract surgery. Main Outcome Measures: The reproducibility of the visual acuity measurements and the changes in LLVAD measurement after cataract surgery. Results: In the COMPLETE study, no clinically significant differences were found in the PL-BCVA, LL-BCVA, or LLVAD measurements between baseline and the 3-month follow-up visits with a change of -1.1 letters, -1.3 letters, and 0.1 letters, respectively (P = 0.02, P = 0.11, and P = 0.88, respectively). In the current study, significant increases were found in the PL-BCVA and LL-BCVA measurements, with a change of 7.3 letters and 10.2 letters after cataract surgery (P < 0.001 for both), and a statistically significant decrease in LLVAD measurements was found, with a change of -3.0 letters after cataract surgery (P = 0.002). Conclusions: Because of the variable effect of cataracts on LL-BCVA measurements and the significant change in LLVAD measurements after cataract surgery, investigators should be aware that cataract surgery during a trial will have an unpredictable impact on LLVAD measurements, and pseudophakic and phakic patients should be analyzed separately.

4.
Digit Health ; 8: 20552076221132105, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36276185

RESUMO

Introduction: There is significant unmet need for patient-centric remote monitoring of visual function for chronic retinal diseases, as demonstrated by the COVID-19 pandemic. The Macustat® central retinal function scan is a novel cloud-based digital health application for remote monitoring. The aim of this study is to assess the efficacy of the Macustat® compared to traditional in-office retinal evaluations. Materials and methods: Patients with underlying macular pathology underwent office-based retinal and visual acuity examinations and OCT macula imaging followed by remote tele-monitoring assessment with the Macustat. Central visual function was assessed with the multi-modal Macustat test using dynamic virtual Amsler grid testing, hyperacuity perimetry and visual acuity testing. The results were compared to the findings of the in-office comprehensive retina exam and OCT evaluation. Results: The foveal acuity potential registered with the Macustat test showed high correlation with the office Snellen acuity potential 96% of eyes registered Macustat acuity within 0.2 LogMAR of office acuity measurement. In Wet AMD eyes with CNV pathology documented on OCT, the Macustat foveal function scan showed a corresponding abnormality in 89% of any CNV eyes and 100% of all visually significant CNV. In normal eyes without any visually significant edema or CNV, more than 92% showed corresponding normal retinal function scan. Conclusion: The Macustat demonstrates high concordance with clinical findings using traditional diagnostic devices. Home monitoring with the Macustat® may offer complementary clinical utility as a telehealth tool for the assessment of visual acuity and macular function in patients at high risk for macular disease.

5.
Front Med (Lausanne) ; 9: 875242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36314006

RESUMO

Background: Many artificial intelligence (AI) studies have focused on development of AI models, novel techniques, and reporting guidelines. However, little is understood about clinicians' perspectives of AI applications in medical fields including ophthalmology, particularly in light of recent regulatory guidelines. The aim for this study was to evaluate the perspectives of ophthalmologists regarding AI in 4 major eye conditions: diabetic retinopathy (DR), glaucoma, age-related macular degeneration (AMD) and cataract. Methods: This was a multi-national survey of ophthalmologists between March 1st, 2020 to February 29th, 2021 disseminated via the major global ophthalmology societies. The survey was designed based on microsystem, mesosystem and macrosystem questions, and the software as a medical device (SaMD) regulatory framework chaired by the Food and Drug Administration (FDA). Factors associated with AI adoption for ophthalmology analyzed with multivariable logistic regression random forest machine learning. Results: One thousand one hundred seventy-six ophthalmologists from 70 countries participated with a response rate ranging from 78.8 to 85.8% per question. Ophthalmologists were more willing to use AI as clinical assistive tools (88.1%, n = 890/1,010) especially those with over 20 years' experience (OR 3.70, 95% CI: 1.10-12.5, p = 0.035), as compared to clinical decision support tools (78.8%, n = 796/1,010) or diagnostic tools (64.5%, n = 651). A majority of Ophthalmologists felt that AI is most relevant to DR (78.2%), followed by glaucoma (70.7%), AMD (66.8%), and cataract (51.4%) detection. Many participants were confident their roles will not be replaced (68.2%, n = 632/927), and felt COVID-19 catalyzed willingness to adopt AI (80.9%, n = 750/927). Common barriers to implementation include medical liability from errors (72.5%, n = 672/927) whereas enablers include improving access (94.5%, n = 876/927). Machine learning modeling predicted acceptance from participant demographics with moderate to high accuracy, and area under the receiver operating curves of 0.63-0.83. Conclusion: Ophthalmologists are receptive to adopting AI as assistive tools for DR, glaucoma, and AMD. Furthermore, ML is a useful method that can be applied to evaluate predictive factors on clinical qualitative questionnaires. This study outlines actionable insights for future research and facilitation interventions to drive adoption and operationalization of AI tools for Ophthalmology.

6.
Artigo em Inglês | MEDLINE | ID: mdl-32440659

RESUMO

A 31-year-old primagravid female at 27 weeks gestation presented to the emergency room with three weeks of progressive blurring of vision associated with intermittent headaches. Ocular examination revealed diminished visual acuity, decreased color discrimination, and constricted confrontation visual fields; optic nerve appearance was however normal. Magnetic resonance imaging of the brain and orbits revealed a large tuberculum meningioma compressing the optic chiasm and prechiasmatic optic nerves, as well as a small sphenoid wing meningioma. Given the risk of permanent vision loss, the patient underwent emergent tumor resection. Near total resection of the masses was achieved and the patient had complete resolution of her vision post-operatively. She gave birth via Caesarean section at 39 weeks. This case report describes the clinical presentations of intracranial meningiomas and discusses the challenges this condition poses in management during pregnancy.

7.
J Telemed Telecare ; 23(4): 476-483, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27177870

RESUMO

Background Ischemic stroke is a time-sensitive disease, with improved outcomes associated with decreased time from onset to treatment. It was hypothesised that ambulance-based assessment of the National Institutes of Health Stroke Scale (NIHSS) using a Health Insurance Portability and Accountability Act (HIPAA)-compliant mobile platform immediately prior to arrival is feasible. Methods This is a proof-of-concept feasibility pilot study in two phases. The first phase consisted of an ambulance-equipped HIPAA-compliant video platform for remote NIHSS assessment of a simulated stroke patient. The second phase consisted of remote NIHSS assessment by a hospital-based neurologist of acute stroke patients en route to our facility. Five ambulances were equipped with a 4G/LTE-enabled tablet preloaded with a secure HIPAA-compliant telemedicine application. Secondary outcomes assessed satisfaction of staff with the remote platform. Results Phase one was successful in the assessment of three out of three simulated patients. Phase two was successful in the assessment of 10 out of 11 (91%) cases. One video attempt was unsuccessful because local LTE was turned off on the device. The video signal was dropped transiently due to weather, which delayed NIHSS assessment in one case. Average NIHSS assessment time was 7.6 minutes (range 3-9.8 minutes). Neurologists rated 83% of encounters as 'satisfied' to 'very satisfied', and the emergency medical service (EMS) rated 90% of encounters as 'satisfied' to 'very satisfied'. The one failed video attempt was associated with 'poor' EMS satisfaction. Conclusion This proof-of-concept pilot demonstrates that remote ambulance-based NIHSS assessment is feasible. This model could reduce door-to-needle times by conducting prehospital data collection.


Assuntos
Serviços Médicos de Emergência/organização & administração , Neurologia/normas , Acidente Vascular Cerebral/terapia , Telemedicina/métodos , Idoso , Ambulâncias , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , National Institutes of Health (U.S.) , Projetos Piloto , Reprodutibilidade dos Testes , Estados Unidos , Comunicação por Videoconferência/organização & administração
8.
Clin Infect Dis ; 40(5): e46-8, 2005 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-15714407

RESUMO

A 39-year-old man with Candida glabrata endophthalmitis was successfully treated with a 28-day course of intravenous caspofungin. Presence of underlying renal insufficiency and infection with a drug-resistant strain precluded use of amphotericin B or fluconazole. Intravitreal administration of antifungals and vitrectomy were not required. The role of caspofungin in Candida endophthalmitis is discussed.


Assuntos
Candida glabrata/isolamento & purificação , Candidíase/diagnóstico , Endoftalmite/tratamento farmacológico , Endoftalmite/microbiologia , Peptídeos Cíclicos/uso terapêutico , Adulto , Antifúngicos/uso terapêutico , Candida glabrata/efeitos dos fármacos , Candidíase/tratamento farmacológico , Candidíase/microbiologia , Caspofungina , Farmacorresistência Fúngica Múltipla , Equinocandinas , Endoftalmite/patologia , Humanos , Lipopeptídeos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA