Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Metabolites ; 14(2)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38393017

RESUMO

Liquid chromatography-high-resolution mass spectrometry (LC-HRMS), as applied to untargeted metabolomics, enables the simultaneous detection of thousands of small molecules, generating complex datasets. Alignment is a crucial step in data processing pipelines, whereby LC-MS features derived from common ions are assembled into a unified matrix amenable to further analysis. Variability in the analytical factors that influence liquid chromatography separations complicates data alignment. This is prominent when aligning data acquired in different laboratories, generated using non-identical instruments, or between batches from large-scale studies. Previously, we developed metabCombiner for aligning disparately acquired LC-MS metabolomics datasets. Here, we report significant upgrades to metabCombiner that enable the stepwise alignment of multiple untargeted LC-MS metabolomics datasets, facilitating inter-laboratory reproducibility studies. To accomplish this, a "primary" feature list is used as a template for matching compounds in "target" feature lists. We demonstrate this workflow by aligning four lipidomics datasets from core laboratories generated using each institution's in-house LC-MS instrumentation and methods. We also introduce batchCombine, an application of the metabCombiner framework for aligning experiments composed of multiple batches. metabCombiner is available as an R package on Github and Bioconductor, along with a new online version implemented as an R Shiny App.

2.
bioRxiv ; 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36778509

RESUMO

Untargeted lipidomics allows analysis of a broader range of lipids than targeted methods and permits discovery of unknown compounds. Previous ring trials have evaluated the reproducibility of targeted lipidomics methods, but inter-laboratory comparison of compound identification and unknown feature detection in untargeted lipidomics has not been attempted. To address this gap, five laboratories analyzed a set of mammalian tissue and biofluid reference samples using both their own untargeted lipidomics procedures and a common chromatographic and data analysis method. While both methods yielded informative data, the common method improved chromatographic reproducibility and resulted in detection of more shared features between labs. Spectral search against the LipidBlast in silico library enabled identification of over 2,000 unique lipids. Further examination of LC-MS/MS and ion mobility data, aided by hybrid search and spectral networking analysis, revealed spectral and chromatographic patterns useful for classification of unknown features, a subset of which were highly reproducible between labs. Overall, our method offers enhanced compound identification performance compared to targeted lipidomics, demonstrates the potential of harmonized methods to improve inter-site reproducibility for quantitation and feature alignment, and can serve as a reference to aid future annotation of untargeted lipidomics data.

3.
Muscle Nerve ; 67(3): 208-216, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36321729

RESUMO

INTRODUCTION/AIMS: Body mass index (BMI) is linked to amyotrophic lateral sclerosis (ALS) risk and prognosis, but additional research is needed. The aim of this study was to identify whether and when historical changes in BMI occurred in ALS participants, how these longer term trajectories associated with survival, and whether metabolomic profiles provided insight into potential mechanisms. METHODS: ALS and control participants self-reported body height and weight 10 (reference) and 5 years earlier, and at study entry (diagnosis for ALS participants). Generalized estimating equations evaluated differences in BMI trajectories between cases and controls. ALS survival was evaluated by BMI trajectory group using accelerated failure time models. BMI trajectories and survival associations were explored using published metabolomic profiling and correlation networks. RESULTS: Ten-year BMI trends differed between ALS and controls, with BMI loss in the 5 years before diagnosis despite BMI gains 10 to 5 years beforehand in both groups. An overall 10-year drop in BMI associated with a 27.1% decrease in ALS survival (P = .010). Metabolomic networks in ALS participants showed dysregulation in sphingomyelin, bile acid, and plasmalogen subpathways. DISCUSSION: ALS participants lost weight in the 5-year period before enrollment. BMI trajectories had three distinct groups and the group with significant weight loss in the past 10 years had the worst survival. Participants with a high BMI and increase in weight in the 10 years before symptom onset also had shorter survival. Certain metabolomics profiles were associated with the BMI trajectories. Replicating these findings in prospective cohorts is warranted.


Assuntos
Esclerose Lateral Amiotrófica , Humanos , Esclerose Lateral Amiotrófica/diagnóstico , Índice de Massa Corporal , Estudos Prospectivos , Metabolômica , Prognóstico
4.
J Proteome Res ; 21(12): 2936-2946, 2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36367990

RESUMO

Untargeted liquid chromatography-mass spectrometry metabolomics studies are typically performed under roughly identical experimental settings. Measurements acquired with different LC-MS protocols or following extended time intervals harbor significant variation in retention times and spectral abundances due to altered chromatographic, spectrometric, and other factors, raising many data analysis challenges. We developed a computational workflow for merging and harmonizing metabolomics data acquired under disparate LC-MS conditions. Plasma metabolite profiles were collected from two sets of maternal subjects three years apart using distinct instruments and LC-MS procedures. Metabolomics features were aligned using metabCombiner to generate lists of compounds detected across all experimental batches. We applied data set-specific normalization methods to remove interbatch and interexperimental variation in spectral intensities, enabling statistical analysis on the assembled data matrix. Bioinformatics analyses revealed large-scale metabolic changes in maternal plasma between the first and third trimesters of pregnancy and between maternal plasma and umbilical cord blood. We observed increases in steroid hormones and free fatty acids from the first trimester to term of gestation, along with decreases in amino acids coupled to increased levels in cord blood. This work demonstrates the viability of integrating nonidentically acquired LC-MS metabolomics data and its utility in unconventional metabolomics study designs.


Assuntos
Aminoácidos , Metabolômica , Gravidez , Feminino , Humanos , Metabolômica/métodos , Cromatografia Líquida , Espectrometria de Massas/métodos , Aminoácidos/metabolismo , Plasma/metabolismo
5.
Brain ; 145(12): 4425-4439, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-35088843

RESUMO

Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disease lacking effective treatments. This is due, in part, to a complex and incompletely understood pathophysiology. To shed light, we conducted untargeted metabolomics on plasma from two independent cross-sectional ALS cohorts versus control participants to identify recurrent dysregulated metabolic pathways. Untargeted metabolomics was performed on plasma from two ALS cohorts (cohort 1, n = 125; cohort 2, n = 225) and healthy controls (cohort 1, n = 71; cohort 2, n = 104). Individual differential metabolites in ALS cases versus controls were assessed by Wilcoxon, adjusted logistic regression and partial least squares-discriminant analysis, while group lasso explored sub-pathway level differences. Adjustment parameters included age, sex and body mass index. Metabolomics pathway enrichment analysis was performed on metabolites selected using the above methods. Additionally, we conducted a sex sensitivity analysis due to sex imbalance in the cohort 2 control arm. Finally, a data-driven approach, differential network enrichment analysis (DNEA), was performed on a combined dataset to further identify important ALS metabolic pathways. Cohort 2 ALS participants were slightly older than the controls (64.0 versus 62.0 years, P = 0.009). Cohort 2 controls were over-represented in females (68%, P < 0.001). The most concordant cohort 1 and 2 pathways centred heavily on lipid sub-pathways, including complex and signalling lipid species and metabolic intermediates. There were differences in sub-pathways that were enriched in ALS females versus males, including in lipid sub-pathways. Finally, DNEA of the merged metabolite dataset of both ALS and control cohorts identified nine significant subnetworks; three centred on lipids and two encompassed a range of sub-pathways. In our analysis, we saw consistent and important shared metabolic sub-pathways in both ALS cohorts, particularly in lipids, further supporting their importance as ALS pathomechanisms and therapeutics targets.


Assuntos
Esclerose Lateral Amiotrófica , Doenças Neurodegenerativas , Masculino , Feminino , Humanos , Esclerose Lateral Amiotrófica/metabolismo , Estudos Transversais , Metabolômica/métodos , Lipídeos
6.
Anal Chem ; 93(48): 15840-15849, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34794310

RESUMO

Untargeted metabolomics is an essential component of systems biology research, but it is plagued by a high proportion of detectable features not identified with a chemical structure. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) experiments produce spectra that can be searched against databases to help identify or classify these unknowns, but many features do not generate spectra of sufficient quality to enable successful annotation. Here, we explore alterations to gradient length, mass loading, and rolling precursor ion exclusion parameters for reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) that improve compound identification performance for human plasma samples. A manual review of spectral matches from the HILIC data set was used to determine reasonable thresholds for search score and other metrics to enable semi-automated MS/MS data analysis. Compared to typical LC-MS/MS conditions, methods adapted for compound identification increased the total number of unique metabolites that could be matched to a spectral database from 214 to 2052. Following data alignment, 68.0% of newly identified features from the modified conditions could be detected and quantitated using a routine 20-min LC-MS run. Finally, a localized machine learning model was developed to classify the remaining unknowns and select a subset that shared spectral characteristics with successfully identified features. A total of 576 and 749 unidentified features in the HILIC and RPLC data sets were classified by the model as high-priority unknowns or higher-importance targets for follow-up analysis. Overall, our study presents a simple strategy to more deeply annotate untargeted metabolomics data for a modest additional investment of time and sample.


Assuntos
Metabolômica , Espectrometria de Massas em Tandem , Cromatografia Líquida , Cromatografia de Fase Reversa , Humanos , Interações Hidrofóbicas e Hidrofílicas
7.
Anal Chem ; 93(12): 5028-5036, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33724799

RESUMO

LC-HRMS experiments detect thousands of compounds, with only a small fraction of them identified in most studies. Traditional data processing pipelines contain an alignment step to assemble the measurements of overlapping features across samples into a unified table. However, data sets acquired under nonidentical conditions are not amenable to this process, mostly due to significant alterations in chromatographic retention times. Alignment of features between disparately acquired LC-MS metabolomics data could aid collaborative compound identification efforts and enable meta-analyses of expanded data sets. Here, we describe metabCombiner, a new computational pipeline for matching known and unknown features in a pair of untargeted LC-MS data sets and concatenating their abundances into a combined table of intersecting feature measurements. metabCombiner groups features by mass-to-charge (m/z) values to generate a search space of possible feature pair alignments, fits a spline through a set of selected retention time ordered pairs, and ranks alignments by m/z, mapped retention time, and relative abundance similarity. We evaluated this workflow on a pair of plasma metabolomics data sets acquired with different gradient elution methods, achieving a mean absolute retention time prediction error of roughly 0.06 min and a weighted per-compound matching accuracy of approximately 90%. We further demonstrate the utility of this method by comprehensively mapping features in urine and muscle metabolomics data sets acquired from different laboratories. metabCombiner has the potential to bridge the gap between otherwise incompatible metabolomics data sets and is available as an R package at https://github.com/hhabra/metabCombiner and Bioconductor.


Assuntos
Metabolômica , Cromatografia Líquida , Espectrometria de Massas , Fluxo de Trabalho
8.
Pediatr Surg Int ; 36(8): 977-981, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32415355

RESUMO

PURPOSE: Short-term surgical missions can provide communities in need with desired expertise; however, it is uncertain who will manage the complications after visiting experts leave. Poor outcomes, decreased patient satisfaction, and tension on the healthcare system develop when local providers, often excluded from the initial patient care, are unable to cope with subsequent morbidity. METHODS: Two-year retrospective review of pediatric general, plastic, and reconstructive surgery, and urology cases performed by a relief organization in the developing world. Case complexity and postoperative complications were analyzed. Phone interviews conducted with patients/families to quantify postoperative outcomes and satisfaction. RESULTS: 474 surgeries were performed on pediatric patients with 60% response rate. Respondents stratified into three levels of complexity: 159 simple, 72 intermediate, and 54 advanced surgeries. Six (2.1%) high-level complications occurred. No association between the complexity of the surgery and the occurrence of a complications. 83.5% were satisfied with outcomes and > 92% were happy with the provided support. CONCLUSION: Facilitating visiting and local surgeons performing cases together increases the expertise of local providers, strengthens infrastructure, and establishes clear follow-up. Despite complications, patients and families continued to recommend care to family and friends by the relief organization and were happy with support from local providers. Engaging local providers is the gold-standard for short-term trips.


Assuntos
Colaboração Intersetorial , Missões Médicas/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Operatórios/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Países em Desenvolvimento , Feminino , Humanos , Lactente , Entrevistas como Assunto , Masculino , Oriente Médio/epidemiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Tempo , Adulto Jovem
9.
Bioinformatics ; 36(6): 1801-1806, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31642507

RESUMO

MOTIVATION: When metabolites are analyzed by electrospray ionization (ESI)-mass spectrometry, they are usually detected as multiple ion species due to the presence of isotopes, adducts and in-source fragments. The signals generated by these degenerate features (along with contaminants and other chemical noise) obscure meaningful patterns in MS data, complicating both compound identification and downstream statistical analysis. To address this problem, we developed Binner, a new tool for the discovery and elimination of many degenerate feature signals typically present in untargeted ESI-LC-MS metabolomics data. RESULTS: Binner generates feature annotations and provides tools to help users visualize informative feature relationships that can further elucidate the underlying structure of the data. To demonstrate the utility of Binner and to evaluate its performance, we analyzed data from reversed phase LC-MS and hydrophilic interaction chromatography (HILIC) platforms and demonstrated the accuracy of selected annotations using MS/MS. When we compared Binner annotations of 75 compounds previously identified in human plasma samples with annotations generated by three similar tools, we found that Binner achieves superior performance in the number and accuracy of annotations while simultaneously minimizing the number of incorrectly annotated principal ions. Data reduction and pattern exploration with Binner have allowed us to catalog a number of previously unrecognized complex adducts and neutral losses generated during the ionization of molecules in LC-MS. In summary, Binner allows users to explore patterns in their data and to efficiently and accurately eliminate a significant number of the degenerate features typically found in various LC-MS modalities. AVAILABILITY AND IMPLEMENTATION: Binner is written in Java and is freely available from http://binner.med.umich.edu. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Metabolômica , Espectrometria de Massas em Tandem , Cromatografia Líquida , Humanos , Íons , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA