Magn Reson Med Sci ; 22(1): 103-115, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34897148

RESUMO

23Na-MRI provides information on Na+ content, and its application in the medical field has been highly anticipated. However, for existing clinical 1H-MRI systems, its implementation requires an additional broadband RF transmitter, dedicated transceivers, and RF coils for Na+ imaging. However, a standard medical MRI system cannot often be modified to perform 23Na imaging. We have developed an add-on crossband RF repeater system that enables 23Na-MRI simply by inserting it into the magnet bore of an existing 1H MRI. The three axis gradient fields controlled by the 1H-MRI system were directly used for 23Na imaging without any deformation. A crossband repeater is a common technique used for amateur radio. This concept was proven by a saline solution phantom and in vivo mouse experiments. This add-on RF platform is applicable to medical 1H MRI systems and can enhance the application of 23Na-MRI in clinical usage.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Camundongos , Animais , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Imãs
3.
Magn Reson Med Sci ; 22(1): 127-136, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35321985

RESUMO

We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.


Assuntos
Imageamento por Ressonância Magnética , Testículo , Masculino , Humanos , Testículo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Artefatos
4.
RSC Adv ; 11(33): 20252-20257, 2021 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35479919

RESUMO

The dynamic behavior of alkali metal ions, Li+, Na+, K+, Rb+ and Cs+ in aqueous solutions is one of the most important topics in solution chemistry. Since these alkali metals contain nuclear magnetic resonance (NMR) active nuclei, it is possible to directly measure the diffusion constants of the alkali metal ions using the pulsed field gradient (PFG) NMR method. In this paper, the 7Li, 23Na, 87Rb, 133Cs and 1H resonances are observed for diffusion constants in aqueous solution and the solvent H2O. Until now, the values of the diffusion constant have been lacking when discussing hydration effects around alkali metal ions. It is known that the static ionic radius (R ion) increases with increasing the atomic number, and the experimental diffusion constants also increase with increasing the atomic number, which is opposite to the Stokes-Einstein (SE) relation. It suggests that alkali metal ions diffuse through a space of 10-6 m accompanying the hydrated spheres with a time interval of 10-3 s. For each alkali metal ion, the dynamic ionic radius is evaluated.

5.
Phys Chem Chem Phys ; 21(42): 23589-23597, 2019 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-31621713

RESUMO

Ion-conducting garnets are important candidates for use in all-solid Li batteries and numerous materials have been synthesized with high ionic conductivities. For understanding ion conduction mechanisms, knowledge on Li+ diffusion behaviour is essential. The proposed nano-scale lithium pathways are composed of tortuous and narrow Li+ channels. The pulsed gradient spin-echo (PGSE) NMR method provides time-dependent 7Li diffusion on the micrometre space. For powder samples, collision-diffraction echo-attenuation plots were observed in a short observation time, which had not been fully explained. The diffraction patterns were reduced or disappeared for single-crystal garnet samples of Li6.5La3Zr1.5Ta0.5O12 (LLZO-Ta) and Li6.5La3Zr1.5Nb0.5O12 (LLZO-Nb). The inner morphology and grain boundaries affect importantly the collision-diffraction behaviours which is inherent to powder samples. The 7Li diffusion observed by PGSE-NMR depends on the observation time (Δ) and the pulsed field gradient (PFG) strength (g) in both powder and single-crystal samples, and the anomalous effects were reduced in the single-crystal samples. The scattered Li diffusion constants converged to a unique value (DLi) with a long Δ and a large g, which is eventually the smallest value. The DLi activation energy was close to that of the ionic conductivity (σ). The DLi values are plotted versus the σ values measured for four powder and two single-crystal garnet samples. Assuming the Nernst-Einstein (NE) relation which was derived for isolated ions in solution, the carrier numbers (NNE) were estimated from the experimental values of DLi and σ. The NNE values of metal-containing garnets were large (<1023 cm-3) and insensitive to temperature. They were larger than Li atomic numbers in cm3 calculated from the density, molecular formula and Avogadro number for LLZOs except for cubic LLZO (Li7La3Zr2O12, NNE∼ 1020 cm-3).

6.
Phys Chem Chem Phys ; 20(26): 17615-17623, 2018 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-29926032

RESUMO

The migration behaviours of Li+ in three garnet- and one NASICON-type solid oxide electrolytes were studied on the micrometre scale by pulsed-gradient spin-echo (PGSE) 7Li NMR diffusion spectroscopy to clarify common and specific characteristics of each electrolyte. In these solid electrolytes, clear evidences of grain boundary effects in the diffusion of Li+ were not observed. The Li+ diffusion constants were dependent on parameters such as observation time (Δ) and pulsed field gradient (PFG) strength (g) for all the studied inorganic solid electrolytes. For low Δ values, Li+ ions underwent collisions and diffractions with diffraction distance Rdiffraction [µm]. The apparent Li+ diffusion constants (Dapparent [m2 s-1]) exhibited distributions in a wide range. In this paper, we introduced the apparent diffusion radius, rradius [µm], and compared it with Rdiffraction and mean square displacement (MSD) [µm]; the lengths of these distances were of the micrometre order (10-6 m). The relations between the values of rradius, Rdiffraction and MSD suggested that the migration behaviours of Li+ on the micrometre scale were complicated. Using high Δ and high g values, we obtained an equilibrated value of DLi. The temperature dependences of the number of carrier ions were estimated from the DLi values and ionic conductivities in the four solid oxide electrolytes. For simple comparison and reference, the data of DLi and ionic conductivity of LiPF6 in 1 M solution of propylene carbonate were added.

7.
Rev Sci Instrum ; 88(1): 014701, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147668

RESUMO

A small radio-frequency (rf) coil inserted into a polymer electrolyte fuel cell (PEFC) can be used to acquire nuclear magnetic resonance (NMR) signals from the water in a membrane electrode assembly (MEA) or in oxygen gas channels in the PEFC. Measuring the spatial distribution of the water in a large PEFC requires using many rf probes, so an NMR measurement system which acquires NMR signals from 128 rf probes at intervals of 0.5 s was manufactured. The system has eight rf transceiver units with a field-programmable gate array (FPGA) for modulation of the excitation pulse and quadrature phase detection of the NMR signal, and one control unit with two ring buffers for data control. The sequence data required for the NMR measurement were written into one ring buffer. The acquired NMR signal data were then written temporarily into the other ring buffer and then were transmitted to a personal computer (PC). A total of 98 rf probes were inserted into the PEFC that had an electrical generation area of 16 cm × 14 cm, and the water generated in the PEFC was measured when the PEFC operated at 100 A. As a result, time-dependent changes in the spatial distribution of the water content in the MEA and the water in the oxygen gas channels were obtained.

8.
J Chem Phys ; 146(2): 024701, 2017 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-28088148

RESUMO

Mobile lithium ions in a cubic garnet Li7La3Zr2O12 (Al-stabilized) were studied using 7Li NMR spectroscopy for membrane and powder samples, the latter of which was ground from the membrane. Lithium diffusion in a micrometer space was measured using the pulsed-gradient spin-echo 7Li NMR method between 70 and 130 °C. When the observation time (Δ) was shorter than 20 ms, the echo attenuation showed diffusive diffraction patterns, indicating that the Li+ diffusing space is not free but restricted. For longer Δ, the values of apparent diffusion constant (Dapparent) became gradually smaller to approach an equilibrated value (close to a tracer diffusion constant). In addition, the Dapparent depends on the pulse field gradient strength (g) and became smaller as g became larger. These experimental results suggest that the lithium ions diffuse through Li+ pathways surrounded by stationary anions and lithium ions, and are affected by collisions and diffractions. One-dimensional profiles of the membrane sample of thickness 0.5 mm were observed from 65 to 110 °C and the area intensity, as well as the lithium occurrence near the surface, increased with the increase in temperature. The temperature-dependent area intensity showed a correspondence to the number of Li+ carrier ions estimated from the ionic conductivity and the equilibrated diffusion constant through the Nernst-Einstein relationship.

9.
Tree Physiol ; 36(10): 1210-1218, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27354714

RESUMO

Although previous studies have suggested that branch dieback and whole-plant death due to drought stress occur at 50-88% loss of stem hydraulic conductivity (P50 and P88, respectively), the dynamics of catastrophic failure in the water-conducting pathways in whole plants subjected to drought remain poorly understood. We examined the dynamics of drought stress tolerance in 3-year-old Japanese black pine (Pinus thunbergii Parl.). We nondestructively monitored (i) the spatial distribution of drought-induced embolisms in the stem at greater than P50 and (ii) recovery from embolisms following rehydration. Stem water distributions were visualized by cryo-scanning electron microscopy. The percentages of both embolized area and loss of hydraulic conductivity showed similar patterns of increase, although the water loss in xylem increased markedly at -5.0 MPa or less. One seedling that had reached 72% loss of the water-conducting area survived and the xylem water potential recovered to -0.3 MPa. We concluded that Japanese black pines may need to maintain water-filled tracheids within earlywood of the current-year xylem under natural conditions to avoid disconnection of water movement between the stem and the tops of branches. It is necessary to determine the spatial distribution of embolisms around the point of the lethal threshold to gain an improved understanding of plant survival under conditions of drought.


Assuntos
Secas , Pinus/metabolismo , Xilema/metabolismo , Estresse Fisiológico , Água/metabolismo
10.
Magn Reson Med Sci ; 14(4): 359-66, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25833268

RESUMO

We constructed an arm holder for muscle exercise from a forearm-shaped plastic shell and magnetic resonance (MR) imaging position markers and determined the echo time (39 ms) for T2-weighted spin-echo MR imaging from T2values of the exercised (50 ms) and resting (32 ms) muscle at 0.2 tesla. The smallest detectable muscle was the extensor digiti minimi muscle (cross-sectional area 25 mm²). This combination could be useful to monitor finger exercise in patients undergoing physical therapy.


Assuntos
Exercício Físico/fisiologia , Dedos/fisiologia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/fisiologia , Adulto , Anatomia Transversal/métodos , Feminino , Antebraço/fisiologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Articulação Metacarpofalângica/fisiologia , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Relaxamento Muscular/fisiologia , Articulação do Punho/fisiologia , Adulto Jovem
11.
Plant Cell Environ ; 38(12): 2508-18, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25630712

RESUMO

Development of xylem embolism during water stress in two diffuse-porous hardwoods, Katsura (Cercidiphyllum japonicum) and Japanese white birch (Betula platyphylla var. japonica), was observed non-destructively under a compact magnetic resonance imaging (MRI) system in addition to conventional quantitation of hydraulic vulnerability to cavitation from excised stem segments. Distribution of white and dark areas in MR images corresponded well to the distribution of water-filled/embolized vessels observed by cryo-scanning electron microscopy in both species. Water-filled vessels were observed in MR images as white areas in Katsura and as white dots in Japanese white birch, respectively, and embolisms could be detected as a change to dark areas. The increase in the relative embolized area (REA: %) in the cross-sectional area of total xylem during water stress, which was estimated from the binarized MR images, was consistent with the hydraulic vulnerability curves of these species. From the non-destructive MRI observations, cavitation induced by water stress was shown to develop earlier in 1- or 2-year-old xylem than in the current-year xylem in both species; that is, the vulnerability to cavitation differs between vessels in the current-year xylem and those in older annual rings.


Assuntos
Betula/fisiologia , Imageamento por Ressonância Magnética/métodos , Magnoliopsida/fisiologia , Xilema/fisiologia , Betula/ultraestrutura , Desidratação , Magnoliopsida/ultraestrutura , Caules de Planta/fisiologia , Caules de Planta/ultraestrutura , Porosidade , Água/fisiologia , Xilema/ultraestrutura
12.
Magn Reson Med Sci ; 13(4): 285-91, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25167877

RESUMO

We critically evaluated analog and digital transceivers for magnetic resonance (MR) imaging systems under identical experimental conditions to identify and compare their advantages and disadvantages. MR imaging experiments were performed using a 4.74-tesla vertical-bore superconducting magnet and a high sensitivity gradient coil probe. We acquired 3-dimensional spin echo images of a kumquat with and without using a gain-stepping scan technique to extend the dynamic range of the receiver systems. The acquired MR images clearly demonstrated nearly identical image quality for both transceiver systems, but DC and ghosting artifacts were obtained for the analog transceiver system. We therefore concluded that digital transceivers have several advantages over the analog transceivers.


Assuntos
Fontes de Energia Elétrica , Imageamento por Ressonância Magnética/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Imageamento Tridimensional
13.
J Magn Reson ; 234: 147-53, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23876781

RESUMO

The water generation and water transport occurring in a polymer electrolyte fuel cell (PEFC) can be estimated from the current density generated in the PEFC, and the water content in the polymer electrolyte membrane (PEM). In order to measure the spatial distributions and time-dependent changes of current density generated in a PEFC and the water content in a PEM, we have developed an eight-channel nuclear magnetic resonance (NMR) system. To detect a NMR signal from water in a PEM at eight positions, eight small planar RF detection coils of 0.6 mm inside diameter were inserted between the PEM and the gas diffusion layer (GDL) in a PEFC. The local current density generated at the position of the RF detection coil in a PEFC can be calculated from the frequency shift of the obtained NMR signal due to an additional magnetic field induced by the local current density. In addition, the water content in a PEM at the position of the RF detection coil can be calculated by the amplitude of the obtained NMR signal. The time-dependent changes in the spatial distributions were measured at 4 s intervals when the PEFC was operated with supply gas under conditions of fuel gas utilization of 0.67 and relative humidity of the fuel gas of 70%RH. The experimental result showed that the spatial distributions of the local current density and the water content in the PEM within the PEFC both fluctuated with time.

14.
J Magn Reson ; 226: 45-51, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23211549

RESUMO

Longitudinal nuclear magnetic resonance (NMR) parameter measurements of Japanese pear fruit (Pyrus pyrifolia Nakai, Kosui) were performed using an electrically mobile magnetic resonance imaging (MRI) system with a 0.2 T and 16 cm gap permanent magnet. To measure the relaxation times and apparent diffusion coefficients of the pear fruit in relation to their weight, seven pear fruits were harvested almost every week during the cell enlargement period and measured in a research orchard. To evaluate the in situ relaxation times, six pear fruits were longitudinally measured for about two months during the same period. The measurements for the harvested samples showed good agreement with the in situ measurements. From the measurements of the harvested samples, it is clear that the relaxation rates of the pear fruits linearly change with the inverse of the linear dimension of the fruits, demonstrating that the relaxation mechanism is a surface relaxation. We therefore conclude that the mobile MRI system is a useful device for measuring the NMR parameters of outdoor living plants.


Assuntos
Imageamento por Ressonância Magnética/métodos , Pyrus/crescimento & desenvolvimento , Campos Eletromagnéticos , Processamento de Imagem Assistida por Computador , Japão , Estudos Longitudinais , Espectroscopia de Ressonância Magnética , Pyrus/fisiologia
15.
Rev Sci Instrum ; 83(5): 053702, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667620

RESUMO

We have developed a pulse programmer for magnetic resonance imaging (MRI) using a personal computer and a commercially available high-speed digital input-output board. The software for the pulse programmer was developed using C∕C++ and .NET Framework 2.0 running under the Windows 7 operating system. The pulse programmer was connected to a digital MRI transceiver using a 32-bit parallel interface, and 128-bit data (16 bits × 8 words) for the pulse sequence and the digitally detected MRI signal were transferred bi-directionally every 1 µs. The performance of the pulse programmer was evaluated using a 1.0 T permanent magnet MRI system. The acquired MR images demonstrated the usefulness of the pulse programmer. Although our pulse programmer was developed for a specially designed digital MRI transceiver, our approach can be used for any MRI system if the interface for the transceiver is properly designed. Therefore, we have concluded that our approach is promising for MRI pulse programmers.

16.
Magn Reson Med Sci ; 10(3): 159-67, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21959998

RESUMO

We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was about 60 ppm, and the root-mean-square was 8 ppm. We measured room temperature, magnet temperature, and NMR frequency of the magnet simultaneously every minute for about 68 hours with and without the thermal insulator of the magnet. A simple mathematical model described the magnet's thermal property. Based on magnet performance, we performed high resolution (up to [20 µm](2)) imaging with internal NMR lock sequences of several biological samples. Our results demonstrated the usefulness of the high field small yokeless permanent magnet for high resolution NMR imaging.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Desenho de Equipamento , Dedos , Humanos , Imageamento Tridimensional , Campos Magnéticos , Imagens de Fantasmas , Verduras
17.
Mol Imaging ; 10(5): 317-26, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21914429

RESUMO

We assessed lymph drainage in living mice by an integrated imaging method using fluorescence imaging (FLI) and magnetic resonance imaging (MRI). Mice were subcutaneously injected with quantum dots and gadofluorine 8 into the right rear footpad. They were fixed on a transparent flat plate and underwent FLI and MRI successively. Small markers were attached to the mouse surface for spatial coregistration, and image fusion of FLIs and MRIs was performed. Two-dimensional fluorescence reflectance imaging was used for FLI. FLI and MRI provided generally consistent results and demonstrated lymphatic flow to the popliteal, sacral, and iliac lymph nodes in most mice and to the renal, inguinal, and lumbar-aortic lymph nodes in some mice. On the fusion images, the locations of the lymph nodes in the mouse trunk were in good agreement between FLI and MRI, indicating successful spatial registration even for the deep structures. The popliteal node tended to be visualized a little farther caudally in FLI than in MRI, presumably because the overlying tissues were thicker in the cranial portion. Integrated FLI/MRI lymphography with image fusion appears to be a useful tool for analysis of the murine lymphatic system.


Assuntos
Linfonodos/diagnóstico por imagem , Linfografia/métodos , Imageamento por Ressonância Magnética/métodos , Espectrometria de Fluorescência/métodos , Animais , Meios de Contraste/administração & dosagem , Meios de Contraste/química , Feminino , Marcadores Fiduciais , Conteúdo Gastrointestinal , Membro Posterior , Processamento de Imagem Assistida por Computador , Linfonodos/anatomia & histologia , Linfonodos/fisiologia , Camundongos , Camundongos Endogâmicos BALB C , Compostos Organometálicos/administração & dosagem , Compostos Organometálicos/química , Pontos Quânticos , Solanum tuberosum , Imagem Corporal Total
18.
Appl Magn Reson ; 41(1): 1-18, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21957330

RESUMO

Infestation of harvested apple fruits by the peach fruit moth (Carposina sasakii Matsumura) was studied using a dedicated magnetic resonance imaging (MRI) apparatus equipped with a 0.2-T permanent magnet. Infested holes on the three-dimensional (3-D) images tracked ecological movements of peach fruit moth larvae within the food fruits, and thus in their natural habitat. Sensitive short solenoid coil and surface coil detectors were devised to shorten measurement times. The short solenoid coil detected infestation holes at a rate of 6.4 s per image by the single-slice 2-D measurement. The multi-slice 2-D measurement provided six slice images of a fruit within 2 min taken by the two detectors. These results indicate that the 0.2-T MRI apparatus allows one to distinguish sound fruits from infested ones, and also as a means for plant protection and the preservation of natural ecological systems in foreign trade.

19.
Jpn J Radiol ; 29(5): 353-60, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21717305

RESUMO

PURPOSE: The aim of this study was to establish a distortion correction applicable to whole-body imaging of live mice. MATERIALS AND METHODS: All magnetic resonance imaging (MRI) scans were acquired on a compact 1-T permanent magnet unit for mouse imaging using a T1-weighted, three-dimensional (3D) fast low-angle shot sequence. We assessed geometric distortion in MR images of a small 3D grid phantom and determined 3D image transformations for distortion correction. The developed distortion correction was applied to MR images of the 3D grid phantom acquired on another day, and the correction was validated. A two-dimensional (2D) grid phantom was imaged with a mouse to investigate the applicability of the distortion correction to whole-body mouse imaging. RESULTS: Obvious geometric distortion was observed in the MR images of the 3D grid phantom. The application of the developed 3D phantom-based distortion correction reduced distortion in the images of the 3D grid phantom acquired on another day. Geometric distortion was observed in the MR images of the 2D grid phantom acquired together with the mouse. The 3D phantom-based correction decreased the distortion substantially, regardless of mouse positioning. CONCLUSION: The developed distortion correction can reduce distortion in whole-body imaging of live mice and may enhance the capabilities of MRI in small animal experiments.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Algoritmos , Animais , Desenho de Equipamento , Feminino , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Magnetismo , Camundongos , Camundongos Endogâmicos BALB C , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Rev Sci Instrum ; 82(5): 053704, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639504

RESUMO

By combining a 0.3 T permanent magnet with flexible rotation and translation mechanism, a probe with a local electromagnetic shielding, several electrical units, a mobile lift, and an electric wagon, a mobile magnetic resonance imaging (MRI) system was developed for outdoor tree measurements. 2D cross-sectional images of normal and diseased branches of a pear tree were acquired for measurements of T(1), T(2), proton density, and apparent diffusion constant (ADC). The ADC map clearly differentiated diseased from normal branches. A whole-day measurement of the ADC map demonstrated that microscopic water flow in the normal branch changed proportionally with solar radiation. Therefore, we have concluded that our mobile MRI system is a powerful tool for studies of plants in outdoor environments.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Árvores , Difusão , Imageamento por Ressonância Magnética/efeitos adversos , Pyrus , Proteção Radiológica , Fatores de Tempo , Árvores/metabolismo