Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Kidney Blood Press Res ; 46(5): 652-656, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34515141

RESUMO

BACKGROUND: Recently, attention has been focused on the effect of glucagon on blood glucose variability. The dynamics of glucagon have attracted attention as a new target in the treatment of diabetes patients. However, the dynamics of glucagon in hemodialysis (HD) patients with type 2 diabetes mellitus (T2DM) remain unclear. OBJECTIVES: The aim of this study was to assess the dynamics of glucagon in HD patients with T2DM. MATERIALS AND METHODS: We measured plasma glucagon in HD patients with T2DM by liquid chromatography-high-resolution mass spectrometry (LC-HRMS), sandwich enzyme-linked immunosorbent assay (ELISA), and radioimmunoassay (RIA). The glucagon levels measured by each method were compared. We used the glucagon levels determined by our developed LC-HRMS method as the standard in this study. RESULTS: Plasma glucagon levels measured by LC-HRMS before HD were significantly higher than those measured after HD. Plasma glucagon levels measured using sandwich ELISA had a significantly higher correlation with those measured using LC-HRMS compared with RIA. CONCLUSIONS: This was the first study to assess glucagon levels in HD patients with T2DM using LC-HRMS, which is considered a highly accurate method. Sandwich ELISA was shown to measure glucagon levels accurately as well.


Assuntos
Diabetes Mellitus Tipo 2/sangue , Glucagon/sangue , Diálise Renal , Idoso , Cromatografia Líquida , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade
2.
J Diabetes Investig ; 12(2): 286-289, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32548980

RESUMO

Glucagon is detected in plasma even after total pancreatectomy, and it is debated whether this glucagon is derived from the gastrointestinal tract. Here, we applied sandwich enzyme-linked immunosorbent assay (ELISA) and liquid chromatography-high-resolution mass spectrometry to measure plasma glucagon levels in one patient after partial pancreatectomy (one-seventh of the pancreas remaining) and three patients after total pancreatectomy. Sandwich ELISA detected higher glucagon levels in pancreatectomy patients than in healthy individuals. In contrast, liquid chromatography-high-resolution mass spectrometry showed that plasma glucagon levels in pancreatectomy patients were below the lower limit of quantification. Plasma glucagon measured by sandwich ELISA showed a striking correlation with plasma glicentin, suggesting cross-reaction with this gastrointestinal glucagon-related peptide. These results indicated that pancreatectomized patients falsely showed pseudo-hyperglucagonemia when measured by glucagon sandwich ELISA.


Assuntos
Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Células Secretoras de Glucagon/metabolismo , Glucagon/sangue , Pancreatectomia/efeitos adversos , Pancreatopatias/cirurgia , Células Secretoras de Glucagon/patologia , Humanos , Pancreatopatias/sangue , Pancreatopatias/patologia , Prognóstico
3.
Diabetes Res Clin Pract ; 158: 107892, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31669625

RESUMO

AIMS: Glucagon has an important role in glucose homeostasis. Recently, a new plasma glucagon assay based on liquid chromatography-high resolution mass spectrometry was developed. We evaluated the influence of a dipeptidyl peptidase-4 inhibitor (anagliptin) on plasma glucagon levels in Japanese patients with type 2 diabetes by using this new assay. METHODS: Twenty-four patients with type 2 diabetes were enrolled in a prospective, single-center, randomized, open-label study and were randomly allocated to 4 weeks of treatment with metformin (1000 mg/day) or anagliptin (200 mg/day). A liquid test meal labeled with sodium [13C] acetate was ingested before and after the treatment period. Samples of blood and expired air were collected over 3 h. Plasma levels of glucose, glucagon, C-peptide, glucagon-like peptide-1 (GLP-1), and glucose-dependent insulinotropic polypeptide (GIP) were measured, and gastric emptying was also evaluated. RESULTS: Twenty-two patients completed the study (metformin group: n = 10; anagliptin group: n = 12). Glycemic control showed similar improvement in both groups. In the anagliptin group, there was a slight decrease of the incremental area under the plasma concentration versus time curve for glucagon after the test meal (P = 0.048). In addition, the plasma level of active GLP-1 and GIP was increased, and plasma C-peptide was also increased versus baseline. Neither anagliptin nor metformin delayed gastric emptying. CONCLUSIONS: In patients with type 2 diabetes maintained endogenous insulin secretion, anagliptin increased the plasma level of active GLP-1 and GIP in association with a slight stimulation of insulin secretion and slight inhibition of glucagon secretion, but did not delay gastric emptying. Clinical Trial Registry: University hospital Medical Information Network UMIN000028293.


Assuntos
Esvaziamento Gástrico/efeitos dos fármacos , Glucagon/efeitos dos fármacos , Hipoglicemiantes/uso terapêutico , Espectrometria de Massas/métodos , Metformina/uso terapêutico , Pirimidinas/uso terapêutico , Adulto , Idoso , Diabetes Mellitus Tipo 2/sangue , Feminino , Humanos , Hipoglicemiantes/farmacologia , Masculino , Metformina/farmacologia , Pessoa de Meia-Idade , Estudos Prospectivos , Pirimidinas/farmacologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA