RESUMO
The Norwood operation has become common practice to palliate patients with hypoplastic left heart structures. Surgical technique and postoperative care have improved; yet, there remains significant attrition prior to stage II palliation. The objective of this study is to report outcomes before and after standardizing our approach to the Norwood operation. Patients who underwent the Norwood operation at Children's of Alabama were identified, those who underwent hybrid palliation operations were excluded. Pre- (2015-2020) and post- (2020-January 2023) standardization groups were compared and outcomes analyzed. Ninety-one patients were included (pre-standardization 44 (48.3%) and 47 (51.7%) post-standardization). There were no differences in baseline and intraoperative characteristics at Norwood between the pre- and post-standardization groups. Compared with pre-standardization, post-standardization was associated with decreased time to extubation (OR 0.87, 95%CI 0.79-0.96), inotrope duration (OR 0.92, 95%CI 0.86-0.98) and hospital length of stay (OR 0.98, 95%CI 0.96-0.99). There was a trend toward decreased cardiac arrest, reintervention rates, and interstage mortality for the post-standardization group. A standardized approach to complex neonatal cardiac operations such as the Norwood procedure may improve morbidity and decrease hospital resource utilization. We recommend establishing protocols at an institutional level to optimize outcomes in such high-risk patient populations.
RESUMO
We describe a hybrid thrombectomy and central extracorporeal membrane oxygenation for a child in cardiogenic shock due to a massive pulmonary embolism.