Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Adv Sci (Weinh) ; : e2402156, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647410

RESUMO

Lithium metal anode (LMA) emerges as a promising candidate for lithium (Li)-based battery chemistries with high-energy-density. However, inhomogeneous charge distribution from the unbalanced ion/electron transport causes dendritic Li deposition, leading to "dead Li" and parasitic reactions, particularly at high Li utilization ratios (low negative/positive ratios in full cells). Herein, an innovative LMA structural model deploying a hyperporous/hybrid conductive architecture is proposed on single-walled carbon nanotube film (HCA/C), fabricated through a nonsolvent induced phase separation process. This design integrates ionic polymers with conductive carbon, offering a substantial improvement over traditional metal current collectors by reducing the weight of LMA and enabling high-energy-density batteries. The HCA/C promotes uniform lithium deposition even under rapid charging (up to 5 mA cm-2) owing to its efficient mixed ion/electron conduction pathways. Thus, the HCA/C demonstrates stable cycling for 200 cycles with a low negative/positive ratio of 1.0 when paired with a LiNi0.8Co0.1Mn0.1O2 cathode (areal capacity of 5.0 mAh cm-2). Furthermore, a stacked pouch-type full cell using HCA/C realizes a high energy density of 344 Wh kg-1 cell/951 Wh L-1 cell based on the total mass of the cell, exceeding previously reported pouch-type full cells. This work paves the way for LMA development in high-energy-density Li metal batteries.

2.
Front Oncol ; 14: 1304187, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38525415

RESUMO

Purpose: To identify the clinical and genetic variables associated with rim enhancement of pancreatic ductal adenocarcinoma (PDAC) and to develop a dynamic contrast-enhanced (DCE) MRI-based radiomics model for predicting the genetic status from next-generation sequencing (NGS). Materials and methods: Patients with PDAC, who underwent pretreatment pancreatic DCE-MRI between November 2019 and July 2021, were eligible in this prospective study. Two radiologists evaluated presence of rim enhancement in PDAC, a known radiological prognostic indicator, on DCE MRI. NGS was conducted for the tissue from the lesion. The Mann-Whitney U and Chi-square tests were employed to identify clinical and genetic variables associated with rim enhancement in PDAC. For continuous variables predicting rim enhancement, the cutoff value was set based on the Youden's index from the receiver operating characteristic (ROC) curve. Radiomics features were extracted from a volume-of-interest of PDAC on four DCE maps (Ktrans, Kep, Ve, and iAUC). A random forest (RF) model was constructed using 10 selected radiomics features from a pool of 392 original features. This model aimed to predict the status of significant NGS variables associated with rim enhancement. The performance of the model was validated using test set. Results: A total of 55 patients (32 men; median age 71 years) were randomly assigned to the training (n = 41) and test (n = 14) sets. In the training set, KRAS, TP53, CDKN2A, and SMAD4 mutation rates were 92.3%, 61.8%, 14.5%, and 9.1%, respectively. Tumor size and KRAS variant allele frequency (VAF) differed between rim-enhancing (n = 12) and nonrim-enhancing (n = 29) PDACs with a cutoff of 17.22%. The RF model's average AUC from 10-fold cross-validation for predicting KRAS VAF status was 0.698. In the test set comprising 6 tumors with low KRAS VAF and 8 with high KRAS VAF, the RF model's AUC reached 1.000, achieving a sensitivity of 75.0%, specificity of 100% and accuracy of 87.5%. Conclusion: Rim enhancement of PDAC is associated with KRAS VAF derived from NGS-based genetic information. For predicting the KRAS VAF status in PDAC, a radiomics model based on DCE maps showed promising results.

3.
Acta Radiol ; 65(5): 499-505, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38343091

RESUMO

BACKGROUND: The deep learning (DL)-based reconstruction algorithm reduces noise in magnetic resonance imaging (MRI), thereby enabling faster MRI acquisition. PURPOSE: To compare the image quality and diagnostic performance of conventional turbo spin-echo (TSE) T2-weighted (T2W) imaging with DL-accelerated sagittal T2W imaging in the female pelvic cavity. METHODS: This study evaluated 149 consecutive female pelvic MRI examinations, including conventional T2W imaging with TSE (acquisition time = 2:59) and DL-accelerated T2W imaging with breath hold (DL-BH) (1:05 [0:14 × 3 breath-holds]) in the sagittal plane. In 294 randomly ordered sagittal T2W images, two radiologists independently assessed image quality (sharpness, subjective noise, artifacts, and overall image quality), made a diagnosis for uterine leiomyomas, and scored diagnostic confidence. For the uterus and piriformis muscle, quantitative imaging analysis was also performed. Wilcoxon signed rank tests were used to compare the two sets of T2W images. RESULTS: In the qualitative analysis, DL-BH showed similar or significantly higher scores for all features than conventional T2W imaging (P <0.05). In the quantitative analysis, the noise in the uterus was lower in DL-BH, but the noise in the muscle was lower in conventional T2W imaging. In the uterus and muscle, the signal-to-noise ratio was significantly lower in DL-BH than in conventional T2W imaging (P <0.001). The diagnostic performance of the two sets of T2W images was not different for uterine leiomyoma. CONCLUSIONS: DL-accelerated sagittal T2W imaging obtained with three breath-holds demonstrated superior or comparable image quality to conventional T2W imaging with no significant difference in diagnostic performance for uterine leiomyomas.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Pelve , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Adulto , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Idoso , Leiomioma/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem , Interpretação de Imagem Assistida por Computador/métodos , Útero/diagnóstico por imagem
4.
Magn Reson Med ; 91(6): 2483-2497, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342983

RESUMO

PURPOSE: We introduced a novel reconstruction network, jointly unrolled cross-domain optimization-based spatio-temporal reconstruction network (JUST-Net), aimed at accelerating 3D multi-echo gradient-echo (mGRE) data acquisition and improving the quality of resulting myelin water imaging (MWI) maps. METHOD: An unrolled cross-domain spatio-temporal reconstruction network was designed. The main idea is to combine frequency and spatio-temporal image feature representations and to sequentially implement convolution layers in both domains. The k-space subnetwork utilizes shared information from adjacent frames, whereas the image subnetwork applies separate convolutions in both spatial and temporal dimensions. The proposed reconstruction network was evaluated for both retrospectively and prospectively accelerated acquisition. Furthermore, it was assessed in simulation studies and real-world cases with k-space corruptions to evaluate its potential for motion artifact reduction. RESULTS: The proposed JUST-Net enabled highly reproducible and accelerated 3D mGRE acquisition for whole-brain MWI, reducing the acquisition time from fully sampled 15:23 to 2:22 min within a 3-min reconstruction time. The normalized root mean squared error of the reconstructed mGRE images increased by less than 4.0%, and the correlation coefficients for MWI showed a value of over 0.68 when compared to the fully sampled reference. Additionally, the proposed method demonstrated a mitigating effect on both simulated and clinical motion-corrupted cases. CONCLUSION: The proposed JUST-Net has demonstrated the capability to achieve high acceleration factors for 3D mGRE-based MWI, which is expected to facilitate widespread clinical applications of MWI.


Assuntos
Bainha de Mielina , Água , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos
5.
Acad Radiol ; 31(1): 58-66, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37596140

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to verify the feasibility of magnetic resonance fingerprinting (MRF)-derived synovial fluid fraction (SFF) mapping for quantifying subvoxel-sized cartilage defects. MATERIALS AND METHODS: MRF was performed on a 3-Tesla scanner and used to derive T2 and SFF maps. An ex vivo experiment was performed using bovine bone; different numbers of holes (4, 6, 8, 10, and 12) were drilled separately on the articular surface, and SFF values were compared among the drilled areas. In a clinical study, 16 osteoarthritis patients underwent sagittal 3D fast spinecho (FSE) and MRF scanning, and knee cartilage segmentation was performed on each image. For morphologic analysis, fluid-excluded images of the SFF (FEISFF) and T2 maps (FEIT2) were generated using the cartilage segmentations, and the whole-organ magnetic resonance imaging score (WORMS) of each FEI and 3D FSE image were compared using the kappa coefficient. For quantitative analysis, intact cartilage volumes in the SFF (VSFF) and T2 maps (VT2) were calculated, and their correlations with reference to the actual cartilage volume on 3D FSE images (V3D) were evaluated. RESULTS: In the ex vivo experiment, the SFF value increased as the number of holes increased. The kappa coefficients of the WORMS were 0.80 and 0.64 in the SFF and T2 maps, respectively, and substantial to almost perfect agreement was observed in the medial tibiofemoral joint. The V3D-VSFF and V3D-VT2 correlation coefficients differed by 0.03 or more in the medial tibiofemoral joint. CONCLUSION: The MRF-derived SFF map can feasibly evaluate small, invisible cartilage defects and quantify cartilage volumes.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Humanos , Animais , Bovinos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Líquido Sinovial/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Doenças das Cartilagens/patologia , Espectroscopia de Ressonância Magnética
6.
Skeletal Radiol ; 53(6): 1071-1080, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38041749

RESUMO

OBJECTIVES: To assess the T1 and T2 values of bone marrow lesions in spine and pelvis derived from magnetic resonance fingerprinting (MRF) and to evaluate the differences in values among bone metastasis, red marrow and fatty marrow. METHODS: Sixty patients who underwent lumbar spine and pelvic MRI with magnetic resonance fingerprinting were retrospectively included. Among eligible patients, those with bone metastasis, benign red marrow deposition and normal fatty marrow were identified. Two radiologists independently measured the T1 and T2 values from metastatic bone lesions, fatty marrow, and red marrow deposition on three-dimensional-magnetic resonance fingerprinting. Intergroup comparison and interobserver agreement were analyzed. RESULTS: T1 relaxation time was significantly higher in osteoblastic metastasis than in red marrow (1674.6 ± 436.3 vs 858.7 ± 319.5, p < .001). Intraclass correlation coefficients for T1 and T2 values were 0.96 (p < 0.001) and 0.83 (p < 0.001), respectively. T2 relaxation time of osteoblastic metastasis and red marrow deposition had no evidence of a difference (osteoblastic metastasis, 57.9 ± 25.0 vs red marrow, 58.0 ± 34.4, p = 0.45), as were the average T2 values of osteolytic metastasis and red marrow deposition (osteolytic metastasis, 45.3 ± 15.1 vs red marrow, 58.0 ± 34.4, p = 0.63). CONCLUSIONS: We report the feasibility of three-dimensional-magnetic resonance fingerprinting based quantification of bone marrow to differentiate bone metastasis from red marrow. Simultaneous T1 and T2 quantification of metastasis and red marrow deposition was possible in spine and pelvis and showed significant different values with excellent inter-reader agreement. ADVANCE IN KNOWLEDGE: T1 values from three-dimensional-magnetic resonance fingerprinting might be a useful quantifier for evaluating bone marrow lesions.


Assuntos
Medula Óssea , Neoplasias Ósseas , Humanos , Medula Óssea/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Osso e Ossos , Neoplasias Ósseas/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
7.
ACS Appl Mater Interfaces ; 16(1): 594-604, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38114065

RESUMO

For stable battery operation of silicon (Si)-based anodes, utilizing cross-linked three-dimensional (3D) network binders has emerged as an effective strategy to mitigate significant volume fluctuations of Si particles. In the design of cross-linked network binders, careful selection of appropriate cross-linking agents is crucial to maintaining a balance between the robustness and functionality of the network. Herein, we strategically design and optimize a 3D cross-linked network binder through a comprehensive analysis of cross-linking agents. The proposed network is composed of poly(vinyl alcohol) grafted poly(acrylic acid) (PVA-g-PAA, PVgA) and aromatic diamines. PVgA is chosen as the polymer backbone owing to its high flexibility and facile synthesis using an ecofriendly water solvent. Subsequently, an aromatic diamine is employed as a cross-linker to construct a robust amide network that features a resonance-stabilized high modulus and enhanced adhesion. Comparative investigations of three cross-linkers, 2,2'-bis(trifluoromethyl)benzidine, 3,3'-oxidianiline, and 4,4'-oxybis[3-(trifluoromethyl)aniline] (TFODA), highlight the roles of the trifluoromethyl group (-CF3) and the ether linkage. Consequently, PVgA cross-linked with TFODA (PVgA-TFODA), featuring both -CF3 and -O-, establishes a well-balanced 3D network characterized by heightened elasticity and improved binding forces. The optimized Si and SiOx/graphite composite electrodes with the PVgA-TFODA binder demonstrate impressive structural stability and stable cycling. This study offers a novel perspective on designing cross-linked network binders, showcasing the benefits of a multidimensional approach considering chemical and physical interactions.

8.
Curr Oncol ; 30(12): 10299-10310, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38132384

RESUMO

This research aimed to assess the relationship between contrast-enhanced (CE) magnetic resonance fingerprinting (MRF) values and dynamic contrast-enhanced (DCE) MRI parameters including (Ktrans, Kep, Ve, and iAUC). To evaluate the correlation between the MRF-derived values (T1 and T2 values, CE T1 and T2 values, T1 and T2 change) and DCE-MRI parameters and the differences in the parameters between prostate cancer and noncancer lesions in 68 patients, two radiologists independently drew regions-of-interest (ROIs) at the focal prostate lesions. Prostate cancer was identified in 75% (51/68) of patients. The CE T2 value was significantly lower in prostate cancer than in noncancer lesions in the peripheral zone and transition zone. Ktrans, Kep, and iAUC were significantly higher in prostate cancer than noncancer lesions in the peripheral zone (p < 0.05), but not in the transition zone. The CE T1 value was significantly correlated with Ktrans, Ve, and iAUC in prostate cancer, and the CE T2 value was correlated to Ve in noncancer. Some CE MRF values are different between prostate cancer and noncancer tissues and correlate with DCE-MRI parameters. Prostate cancer and noncancer tissues may have different characteristics regarding contrast enhancement.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Meios de Contraste , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
9.
J Transl Med ; 21(1): 914, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38102606

RESUMO

BACKGROUND: Magnetic resonance fingerprinting (MRF) enables fast myelin quantification via the myelin water fraction (MWF), offering a noninvasive method to assess brain development and disease. However, MRF-derived MWF lacks histological evaluation and remains unexamined in relation to leukodystrophy. This study aimed to access MRF-derived MWF through histology in mice and establish links between myelin, development, and leukodystrophy in mice and children, demonstrating its potential applicability in animal and human studies. METHODS: 3D MRF was performed on normal C57BL/6 mice with different ages, megalencephalic leukoencephalopathy with subcortical cyst 1 wild type (MLC1 WT, control) mice, and MLC 1 knock-out (MLC1 KO, leukodystrophy) mice using a 3 T MRI. MWF values were analyzed from 3D MRF data, and histological myelin quantification was carried out using immunohistochemistry to anti-proteolipid protein (PLP) in the corpus callosum and cortex. The associations between 'MWF and PLP' and 'MWF and age' were evaluated in C57BL/6 mice. MWF values were compared between MLC1 WT and MLC1 KO mice. MWF of normal developing children were retrospectively collected and the association between MWF and age was assessed. RESULTS: In 35 C57BL/6 mice (age range; 3 weeks-48 weeks), MWF showed positive relations with PLP immunoreactivity in the corpus callosum (ß = 0.0006, P = 0.04) and cortex (ß = 0.0005, P = 0.006). In 12-week-old C57BL/6 mice MWF showed positive relations with PLP immunoreactivity (ß = 0.0009, P = 0.003, R2 = 0.54). MWF in the corpus callosum (ß = 0.0022, P < 0.001) and cortex (ß = 0.0010, P < 0.001) showed positive relations with age. Seven MLC1 WT and 9 MLC1 KO mice showed different MWF values in the corpus callous (P < 0.001) and cortex (P < 0.001). A total of 81 children (median age, 126 months; range, 0-199 months) were evaluated and their MWF values according to age showed the best fit for the third-order regression model (adjusted R2 range, 0.44-0.94, P < 0.001). CONCLUSION: MWF demonstrated associations with histologic myelin quantity, age, and the presence of leukodystrophy, underscoring the potential of 3D MRF-derived MWF as a rapid and noninvasive quantitative indicator of brain myelin content in both mice and humans.


Assuntos
Bainha de Mielina , Doenças Neurodegenerativas , Criança , Humanos , Camundongos , Animais , Bainha de Mielina/patologia , Água/metabolismo , Estudos Retrospectivos , Camundongos Endogâmicos C57BL , Imageamento por Ressonância Magnética/métodos , Encéfalo/metabolismo
11.
Adv Sci (Weinh) ; 10(34): e2304915, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37870210

RESUMO

Aqueous zinc metal batteries (AZMBs) are emerging energy storage systems that are poised to replace conventional lithium-ion batteries owing to their intrinsic safety, facile manufacturing process, economic benefits, and superior ionic conductivity. However, the issues of inferior anode reversibility and dendritic plating during operation remain challenging for the practical use of AZMBs. Herein, a gel electrolyte based on zwitterionic poly(sulfobetaine methacrylate) (poly(SBMA)) dissolved with different concentrations of ZnSO4 is proposed. Two-dimensional correlation spectroscopy based on Raman analysis reveals an enhanced interaction priority between the polar groups in SBMA and the dissolved ions as electrolyte concentration increases, which establishes a robust interaction and renders homogeneous ion distribution. Attributable to the modified coordination, zwitterionic gel polymer electrolyte with 5 mol kg-1 of ZnSO4 (ZGPE-5) facilitates stable zinc deposition and improves anode reversibility. By taking advantage of preferential coordination, a symmetrical cell evaluation employing ZGPE-5 demonstrates a cycle life over 3600 h, where ZGPE-5 also exerts a beneficial effect on the full cell cycling when assembled with Zn0.25 V2 O5 cathode. This study elucidates changes in the internal ion behavior that are dependent on electrolyte concentrations and pave the way for durable AZMBs.

12.
Acc Chem Res ; 56(16): 2213-2224, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37527443

RESUMO

ConspectusWith the escalating demands of portable electronics, electric vehicles, and grid-scale energy storage systems, the development of next-generation rechargeable batteries, which boasts high energy density, cost effectiveness, and environmental sustainability, becomes imperative. Accelerating these advancements could substantially mitigate detrimental carbon emissions. The pursuit of main objectives has kindled interest in pure silicon as a high-capacity electroactive material, capable of further enhancing the gravimetric and volumetric energy densities compared with traditional graphite counterparts. Despite such promising attributes, pure silicon materials face significant hurdles, primarily due to their drastic volumetric changes during the lithiation/delithiation processes. Volume changes give rise to severe side effects, such as fracturing, pulverization, and delamination, triggering rapid capacity decay. Therefore, mitigating silicon particle fracture remains a primary challenge. Importantly, nanoscale silicon (below 150 nm in size) has shown resilience to stresses induced by repeated volume changes, thereby highlighting its potential as an anode-active material. However, the volume expansion stress not only affects the internal structure of the particle but also disrupts the solid-electrolyte interphase (SEI) layer, formed spontaneously on the outer surface of silicon, causing adverse side reactions. Therefore, despite silicon nanoparticles offering new opportunities, overcoming the associated issues is of paramount importance.Thus, this Account aims to spotlight the significant strides made in the development of pure silicon anodes with particular attention to feature size. From the emergence of nanoscale silicon, the following nanotechnology played a crucial role in growing the particle through nano/microstructuring. Similarly, bulk silicon microparticles gradually surfaced with the post-engineering methods owing to their practical advantages. We briefly discuss the special characteristics of representative examples from bulk silicon engineering and nano/microstructuring, all aimed at overcoming intrinsic challenges, such as limiting large volume changes and stabilizing SEI formation during electrochemical cycling. Subsequently, we outline guidelines for advancing pure silicon anodes to incorporate high mass loading and high energy density. Importantly, these advancements require superior material design and the incorporation of exceptional battery components to ensure compatibility and yield synergistic effects. By broadening the cooperative strategies at the cell and system levels, we anticipate that this Account will provide an insightful analysis of pure silicon anodes and catalyze their practical applications in real battery systems.

13.
Small ; 19(48): e2305416, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37528714

RESUMO

Flexible lithium-ion batteries (LIBs) have attracted significant attention owing to their ever-increasing use in flexible and wearable electronic devices. However, the practical application of flexible LIBs in devices has been plagued by the challenge of simultaneously achieving high energy density and high flexibility. Herein, a hierarchical 3D electrode (H3DE) is introduced with high mass loading that can construct highly flexible LIBs with ultrahigh energy density. The H3DE features a bicontinuous structure and the active materials along with conductive agents are uniformly distributed on the 3D framework regardless of the active material type. The bicontinuous electrode/electrolyte integration enables a rapid ion/electron transport, thereby improving the redox kinetics and lowering the internal cell resistance. Moreover, the H3DE exhibits exceptional structural integrity and flexibility during repeated mechanical deformations. Benefiting from the remarkable physicochemical properties, pouch-type flexible LIBs using H3DE demonstrate stable cycling under various bending states, achieving a record-high energy density (438.6 Wh kg-1 and 20.4 mWh cm-2 ), and areal capacity (5.6 mAh cm-2 ), outperforming all previously reported flexible LIBs. This study provides a feasible solution for the preparation of high-energy-density flexible LIBs for various energy storage devices.

14.
Diagnostics (Basel) ; 13(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36832219

RESUMO

PURPOSE: To evaluate perfusion changes in the pancreas with pancreatic cancer and pancreatic duct dilatation using dynamic contrast-enhanced MRI (DCE-MRI). METHOD: We evaluate the pancreas DCE-MRI of 75 patients. The qualitative analysis includes pancreas edge sharpness, motion artifacts, streak artifacts, noise, and overall image quality. The quantitative analysis includes measuring the pancreatic duct diameter and drawing six regions of interest (ROIs) in the three areas of the pancreas (head, body, and tail) and three vessels (aorta, celiac axis, and superior mesenteric artery) to measure the peak-enhancement time, delay time, and peak concentration. We evaluate the differences in three quantitative parameters among the ROIs and between patients with and without pancreatic cancer. The correlations between pancreatic duct diameter and delay time are also analyzed. RESULTS: The pancreas DCE-MRI demonstrates good image quality, and respiratory motion artifacts show the highest score. The peak-enhancement time does not differ among the three vessels or among the three pancreas areas. The peak-enhancement time and concentrations in the pancreas body and tail and the delay time in the three pancreas areas are significantly longer (p < 0.05) in patients with pancreatic cancer than in those without pancreatic cancer. The delay time was significantly correlated with the pancreatic duct diameters in the head (p < 0.02) and body (p < 0.001). CONCLUSION: DCE-MRI can display the perfusion change in the pancreas with pancreatic cancer. A perfusion parameter in the pancreas is correlated with the pancreatic duct diameter reflecting a morphological change in the pancreas.

15.
Abdom Radiol (NY) ; 48(3): 1090-1099, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36544053

RESUMO

PURPOSE: To compare the diagnostic performance of high-resolution 3D T2-weighted imaging (T2WI) with compressed sensing (CS) sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) to that of conventional T2WI with turbo spin echo (TSE) in prostate MRI. MATERIALS AND METHODS: This study evaluated 179 patients (mean age 69.1 ± 9.3) who underwent prostate biopsy after prostate prebiopsy MRI, including two sets of three-plane T2WI with TSE (thickness: 3 mm, scan time: 10 min 4 s) and CS SPACE (thickness: 0.6 mm, scan time: 4 min 55 s). Two radiologists evaluated two sets of images with the Prostate Imaging-Reporting and Data System (PIRADS) classification and determined the extraprostatic extension (EPE) of the lesion. The diagnostic performance to detect prostate cancer (PIRADS classification) and EPE was compared between the two T2WI sets. RESULTS: Clinically significant cancer (CSC) was diagnosed in 103 patients (57.5%). Areas under the receiver operating characteristic curve of the PIRADS classification on both image sets with T2 TSE and T2 CS SPACE were higher than 0.7 and did not show significant differences for either radiologist (p > 0.05). EPE was confirmed in 25 of 70 patients underwent prostatectomy. For evaluating EPE on MRI, the sensitivity and specificity did not differ between the two T2WI sequences (p > 0.05). CONCLUSION: High-resolution 3D T2WI using CS SPACE, which was acquired within a shorter acquisition time than three-plane T2 TSE, showed comparable diagnostic performance to conventional T2 TSE for detecting CSC and evaluating EPE.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Próstata/patologia , Imageamento Tridimensional/métodos , Sensibilidade e Especificidade , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos
16.
Ultrasonography ; 42(1): 154-164, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36475357

RESUMO

PURPOSE: The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI). METHODS: This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diameters on axial and sagittal images, transverse, and longitudinal diameters on midsagittal images. The volume estimates, volumeax and volumesag, were calculated from the ellipsoid formula by using the AP diameter on axial and sagittal images, respectively. The prostate volume extracted from MRI-based whole-gland segmentation was considered the gold standard. The intraclass correlation coefficient (ICC) was used to evaluate the inter-method agreement between volumeax and volumesag, and agreement with the gold standard. The Wilcoxon signedrank test was used to analyze the differences between the volume estimates and the gold standard. RESULTS: The prostate gland volume estimates showed excellent inter-method agreement, and excellent agreement with the gold standard (ICCs >0.9). Compared with the gold standard, the volume estimates were significantly larger on MRI and significantly smaller on US (P<0.001). The volume difference (segmented volume-volume estimate) was greater in patients with larger prostate glands, especially on US. CONCLUSION: Volumeax and volumesag showed excellent inter-method agreement and excellent agreement with the gold standard on both US and MRI. However, prostate volume was overestimated on MRI and underestimated on US.

17.
Adv Mater ; 35(4): e2203194, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35616903

RESUMO

Riding on the rapid growth in electric vehicles and the stationary energy storage market, high-energy-density lithium-ion batteries and next-generation rechargeable batteries (i.e., advanced batteries) have been long-accepted as essential building blocks for future technology reaching the specific energy density of 400 Wh kg-1 at the cell-level. Such progress, mainly driven by the emerging electrode materials or electrolytes, necessitates the development of polymeric materials with advanced functionalities in the battery to address new challenges. Therefore, it is urgently required to understand the basic chemistry and essential research directions in polymeric materials and establish a library for the polymeric materials that enables the development of advanced batteries. Herein, based on indispensable polymeric materials in advanced high-energy-density lithium-ion, lithium-sulfur, lithium-metal, and dual-ion battery chemistry, the key research directions of polymeric materials for achieving high-energy-density and safety are summarized and design strategies for further improving performance are examined. Furthermore, the challenges of polymeric materials for advanced battery technologies are discussed.

18.
Nanoscale Adv ; 4(6): 1494-1516, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36134364

RESUMO

Wearable electronics is a growing field that has important applications in advanced human-integrated systems with high performance and mechanical deformability, especially foldable characteristics. Although foldable electronics such as rollable TVs (LG signature OLED R) or foldable smartphones (Samsung Galaxy Z fold/flip series) have been successfully established in the market, these devices are still powered by rigid and stiff batteries. Therefore, to realize fully wearable devices, it is necessary to develop state-of-the-art foldable batteries with high performance and safety in dynamic deformation states. In this review, we cover the recent progress in developing materials and system designs for foldable batteries. The Materials section is divided into three sections aimed at helping researchers choose suitable materials for their systems. Several foldable battery systems are discussed and the combination of innovative materials and system design that yields successful devices is considered. Furthermore, the basic analysis process of electrochemical and mechanical properties is provided as a guide for researchers interested in the evaluation of foldable battery systems. The current challenges facing the practical application of foldable batteries are briefly discussed. This review will help researchers to understand various aspects (from material preparation to battery configuration) of foldable batteries and provide a brief guideline for evaluating the performance of these batteries.

19.
Neuroradiology ; 64(12): 2399-2407, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35920890

RESUMO

PURPOSE: The purpose of this study was to compare the image quality of the 3D T2-weighted images accelerated using conventional method (CAI-SPACE) with the images accelerated using compressed sensing (CS-SPACE) in pediatric brain imaging. METHODS: A total of 116 brain MRI (53 with CAI-SPACE and 63 with CS-SPACE) were obtained from children 16 years old or younger. Quantitative image quality was evaluated using the apparent signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The sequences were qualitatively evaluated for overall image quality, general artifact, cerebrospinal fluid (CSF)-related artifact, and grey-white matter differentiation. The two sequences were compared for the total and two age groups (< 24 months vs. ≥ 24 months). RESULTS: Compressed sensing application in 3D T2-weighted imaging resulted in 8.5% reduction in scanning time. Quantitative image quality analysis showed higher apparent SNR (median [Interquartile range]; 29 [25] vs. 23 [14], P = 0.005) and CNR (0.231 [0.121] vs. 0.165 [0.120], P = 0.027) with CS-SPACE compared to CAI-SPACE. Qualitative image quality analysis showed better image quality with CS-SPACE for general (P = 0.024) and CSF-related artifact (P < 0.001). CSF-related artifacts reduction was prominent in the older age group (≥ 24 months). Overall image quality (P = 0.162) and grey-white matter differentiation (P = 0.397) were comparable between CAI-SPACE and CS-SPACE. CONCLUSION: Compressed sensing application in 3D T2-weighted images modestly reduced acquisition time and lowered CSF-related artifact compared to conventional images of the pediatric brain.


Assuntos
Artefatos , Imageamento Tridimensional , Humanos , Criança , Idoso , Pré-Escolar , Adolescente , Imageamento Tridimensional/métodos , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Neuroimagem
20.
Med Phys ; 49(9): 5929-5942, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35678751

RESUMO

PURPOSE: To enable acceleration in 3D multi-echo gradient echo (mGRE) acquisition for myelin water imaging (MWI) by combining joint parallel imaging (JPI) and joint deep learning (JDL). METHODS: We implemented a multistep reconstruction process using both advanced parallel imaging and deep learning network which can utilize joint spatiotemporal components between the multi-echo images to further accelerate 3D mGRE acquisition for MWI. In the first step, JPI was performed to estimate missing k-space lines. Next, JDL was implemented to reduce residual artifacts and produce high-fidelity reconstruction by using variable splitting optimization consisting of spatiotemporal denoiser block, data consistency block, and weighted average block. The proposed method was evaluated for MWI with 2D Cartesian uniform under-sampling for each echo, enabling scan times of up to approximately 2 min for 2 mm × 2 mm × 2 mm $2\ {\rm mm} \times 2\ {\rm mm} \times 2\ {\rm mm}$ 3D coverage. RESULTS: The proposed method showed acceptable MWI quality with improved quantitative values compared to both JPI and JDL methods individually. The improved performance of the proposed method was demonstrated by the low normalized mean-square error and high-frequency error norm values of the reconstruction with high similarity to the fully sampled MWI. CONCLUSION: Joint spatiotemporal reconstruction approach by combining JPI and JDL can achieve high acceleration factors for 3D mGRE-based MWI.


Assuntos
Imageamento por Ressonância Magnética , Bainha de Mielina , Encéfalo , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA