Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
BMC Ophthalmol ; 23(1): 482, 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38001418

RESUMO

BACKGROUND: To compare the accuracy of nine intraocular lens (IOL) power calculation formulas, including three traditional formulas (SRK/T, Haigis, and Hoffer Q) and six new-generation formulas (Barrett Universal II [BUII], Hill-Radial Basis Function [RBF] 3.0, Kane, Emmetropia verifying optical [EVO], Ladas Super, and Pearl-DGS) in patients who underwent cataract surgery after acute primary angle closure (APAC). METHODS: In this retrospective cross-sectional study, 44 eyes of 44 patients (APAC) and 60 eyes of 60 patients (control) were included. We compared the mean absolute error, median absolute error (MedAE), and prediction error after surgery. Subgroup analyses were performed on whether axial length (AL) or preoperative laser peripheral iridotomy affected the postoperative refractive outcomes. RESULTS: In the APAC group, all formulas showed higher MedAE and more myopic shift than the control group (all P < 0.05). In APAC eyes with AL ≥ 22 mm, there were no differences in MedAEs according to the IOL formulas; however, in APAC eyes with AL < 22 mm, Haigis (0.49 D) showed lower MedAE than SRK/T (0.82 D) (P = 0.036) and Hill-RBF 3.0 (0.54 D) showed lower MedAE than SRK/T (0.82 D), Hoffer Q (0.75 D) or Kane (0.83 D) (P = 0.045, 0.036 and 0.027, respectively). Pearl-DGS (0.63 D) showed lower MedAE than Hoffer Q (0.75 D) and Kane (0.83 D) (P = 0.045 and 0.036, respectively). Haigis and Hill-RBF 3.0 showed the highest percentage (46.7%) of eyes with PE within ± 0.5 D in APAC eyes with AL < 22 mm. Iridectomized eyes did not show superior precision than the non-iridotomized eyes in the APAC group. CONCLUSIONS: Refractive errors in the APAC group were more myopic than those in the control group. Haigis and Hill-RBF 3.0 showed high precision in the eyes with AL < 22 mm in the APAC group.


Assuntos
Lentes Intraoculares , Miopia , Facoemulsificação , Humanos , Estudos Retrospectivos , Estudos Transversais , Refração Ocular , Miopia/cirurgia , Óptica e Fotônica , Biometria , Comprimento Axial do Olho
2.
Korean J Ophthalmol ; 37(6): 510-517, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37899279

RESUMO

PURPOSE: To evaluate repeatability and agreement of chord mu between Scheimpflug tomography (Pentacam HR) and sweptsource optical coherence tomography-based optical biometer (IOLMaster 700). METHODS: In this retrospective study, 63 eyes from 33 patients were included. Chord mu, X and Y Cartesian distances between the corneal vertex and the pupil center (Px and Py), and the pupil diameter were compared using two instruments. Repeatability was evaluated using intraclass correlation coefficient (ICC), coefficient of variation (CoV), and within-subject standard deviation (Sw). Interdevice agreement was evaluated using paired t-tests and Bland-Altman plots. RESULTS: Although Sw values for all parameters were similar between the two devices, CoV values of chord mu and pupil diameter were lower, and ICC values of those parameters were higher, in the IOLMaster 700 than in the Pentacam HR. Chord mu and pupil diameter values were higher in IOLMaster 700 than Pentacam HR (p < 0.01). The width of the 95% limit of agreement was wide for all parameters. CONCLUSIONS: IOLMaster 700 showed better repeatability than Pentacam HR in chord mu, Px, Py, and pupil diameter values. Because there were statistically significant differences and a low level of agreement in chord mu and pupil diameter values between the two devices, they cannot be used interchangeably.


Assuntos
Comprimento Axial do Olho , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Comprimento Axial do Olho/anatomia & histologia , Biometria , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea
3.
Cutan Ocul Toxicol ; 42(3): 144-150, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37350680

RESUMO

PURPOSE: To investigate the toxicity of repeated simultaneous intrastromal and intracameral injections of voriconazole in corneal endothelial cells in a rabbit model. METHODS: Thirty-six eyes of 18 New Zealand white rabbits (six eyes per group) were divided into 6 groups according to the concentration of voriconazole (Group A, 0%; Group B, 0.05%; Group C, 0.1%; Group D, 0.25%; Group E, 0.5%; Group F, 1%). A combination of intrastromal and intracameral voriconazole injections were administrated to the eyes of each group three times on days 0, 3, and 7. Corneal clouding grades and central corneal thickness (CCT) were examined on days 0, 3, 7, 10, and 14. The endothelial cell counts (ECC) were measured on days 0 and 14. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were performed on day 14. RESULTS: Group F (1%) showed more severe corneal clouding than the other groups (Groups A-E) from day 7 (p < 0.05, respectively). There were no significant differences in CCT and ECC among the six groups at any time point (p > 0.05, respectively). SEM revealed blurring of the cell border and loss of microvilli at concentrations ≥0.25% (Groups D-F). TEM revealed microstructural changes in endothelial cells at concentrations ≥0.1% (Groups C-F), and multiple vacuoles were observed at a concentration of 1% voriconazole (Group F). CONCLUSIONS: Repeated simultaneous intrastromal and intracameral voriconazole injections at a concentration of 0.1% or higher induced microstructural endothelial damage in rabbit corneal endothelial cells.


Assuntos
Doenças da Córnea , Endotélio Corneano , Coelhos , Animais , Voriconazol/toxicidade , Células Endoteliais , Injeções
4.
Ocul Immunol Inflamm ; 31(8): 1615-1622, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35787222

RESUMO

PURPOSE: To evaluate changes in ocular surface indices and tear cytokines after cataract surgery in type 2 diabetic patients. METHODS: Ocular surface indices and concentrations of tear cytokines (MCP-1, IL-6, IL-8, and VEGF) were evaluated at baseline and one week and one month postoperatively. RESULTS: Patients (30 diabetic and 30 control) were enrolled. In the diabetic group, changes in ocular symptom and tear breakup time remained until one month postoperatively (P < .05, respectively); in the control group, ocular symptom increased at one week postoperatively (P = .015). MCP-1 level in the diabetic group significantly increased postoperatively (all P < .05); however, in the control group, the IL-8 level was significantly decreased postoperatively (all P < .05). MCP-1 concentration was negatively correlated with TBUT in the diabetic group. CONCLUSION: Diabetic patients can experience more prominent changes after surgery and these changes were accompanied by an increase of several tear cytokines.


Assuntos
Catarata , Diabetes Mellitus Tipo 2 , Humanos , Citocinas , Diabetes Mellitus Tipo 2/complicações , Interleucina-8 , Córnea
5.
Korean J Ophthalmol ; 36(4): 326-337, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35766049

RESUMO

PURPOSE: To evaluate the level of agreement between ANTERION (Heidelberg Engineering, Heidelberg, Germany), OA-2000 (Tomey, Nagoya, Japan), and IOLMaster 500 (Carl Zeiss AG, Jena, Germany). METHODS: Fifty-one eyes of 51 patients were included in the study. Flat keratometry (K) and steep K, vector component of astigmatism (Jackson cross-cylinder at 0° and 90° [J0] and Jackson cross-cylinder at 45° and 135° [J45]), anterior chamber depth, and axial length were compared using the three devices. Repeated measures analysis of variance was conducted to compare the mean values of the biometrics. Pearson correlation test was conducted to analyze the correlations of the measured values, and a Bland-Altman plot was used to assess the agreement between the three devices. The predicted intraocular lens power of each device was compared to the others using the SRK/T, Haigis, Barrett Universal II, and Kane formulas. RESULTS: All K values measured using ANTERION were flatter than those of other instruments. However, good agreement was observed for flat K (ANTERION - OA-2000; 95% limits of agreement [LoA], 0.86 diopters [D]) and steep K (ANTERION - OA2000; 95% LoA, 0.93 D) and OA-2000 - IOLMaster 500 (95% LoA, 0.93 D). J0 and J45 vector components of astigmatism were not statistically different; however, the agreements were poor between the devices (95% LoA ≥1.97 D). Anterior chamber depth values of ANTERION and OA-2000 were interchangeable (95% LoA, 0.15 mm). The axial length showed a high agreement (95% LoA ≤0.17 mm) among the three devices. The predicted intraocular lens powers of the three devices were not interchangeable regardless of formulas (95% LoA ≥1.04 D). CONCLUSIONS: Significant differences in ocular biometrics were observed between ANTERION and the other two devices. This study demonstrated that only axial length showed good agreement among devices.


Assuntos
Astigmatismo , Lentes Intraoculares , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Astigmatismo/diagnóstico , Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Córnea/diagnóstico por imagem , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
7.
Korean J Ophthalmol ; 35(5): 337-348, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34237207

RESUMO

PURPOSE: To evaluate the compatibility of corneal curvature and astigmatism, and higher-order aberrations (HOAs) measured by the Scheimpflug camera Pentacam HR and the swept-source optical coherence tomography ANTERION. METHODS: This prospective study included normal subjects with no ophthalmic history. Steep keratometry (K), flat K, astigmatism and its axis of the anterior and posterior surfaces, total corneal power, and HOAs using the two instruments were compared. To compare the mean values of the measurements, a paired t-test was used. Bland-Altman analysis was applied to assess the agreement between the two devices. RESULTS: Fifty-three eyes of 53 subjects were evaluated. There were statistically significant differences for steep K, astigmatism, and vector J0, J45 in the anterior surface and total corneal power between the two devices (p < 0.05). There were also significant differences in the most of the keratometric values of the posterior corneal surface (p < 0.05) except J0 (p = 0.410). Both devices showed strong positive correlations in steep K, flat K, astigmatism (r > 0.81, p < 0.001) with wide ranges of a 95% limit of agreement. Vectoral components were significantly correlated (r > 0.78, p < 0.001) with narrow 95% limit of agreement, except J45 of the posterior surface (r = 0.39, p = 0.004). In the corneal HOAs, there were statistically significant differences in the vertical coma, horizontal trefoil, spherical aberration, and root mean square of each fifth- and sixth-order Zernike coefficient (p = 0.043, p = 0.041, p < 0.001, p < 0.001, and p < 0.001, respectively). Other HOAs showed moderate to strong positive correlations (r > 0.37, p < 0.05). Most HOAs, except for the horizontal trefoil, showed clinically acceptable agreements. The total root mean square of HOAs was not significantly different between the two devices (p = 0.122). CONCLUSIONS: Most of the keratometric values cannot be used interchangeably. However, the vectoral component of astigmatism showed clinically good agreement. Several HOAs have statistically significant differences; however, almost all HOAs showed acceptable agreements, except for the horizontal trefoil.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Astigmatismo/diagnóstico , Córnea/diagnóstico por imagem , Topografia da Córnea , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Am J Ophthalmol ; 218: 78-83, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32574776

RESUMO

PURPOSE: This study investigated the clinical manifestation and risk factors associated with remission in filamentary keratitis. DESIGN: Retrospective, interventional, comparative case series. METHODS: We retrospectively reviewed the medical records of 116 patients with filamentary keratitis diagnosed and treated between January 2012 and December 2018. We investigated the 5 causative factors including brain lesion, dry eye syndrome, autoimmune disease, ocular surgery or injury, and other conditions; treatment methods and duration; and remission status, and analyzed the risk factors associated with remission. RESULTS: The mean age of the patients was 56.9 ± 19.1 years and the mean follow-up duration was 14.9 ± 22.8 months. The most common underlying condition associated with filamentary keratitis was identified as a brain lesion (36.2%), followed by dry eye syndrome (30.2%) and autoimmune disease (24.1%). A comparison of remission rates among the causative factors revealed that cases associated with brain lesions had significantly lower remission rates (33.3%) than those associated with other causative factors (>60%) (P = .001). After adjustment for sex, age, diabetes mellitus, and hypertension, the treatment failure rate in patients affected by brain lesions was 6.602-fold higher than that associated without brain lesion (P = .001). The treatment method-dependent differences in the remission rate were observed in brain lesion and dry eye syndrome (P = .041 and P = .005, respectively). CONCLUSIONS: The most common condition leading to filamentary keratitis was a brain lesion, followed by dry eye syndrome and autoimmune disease. The treatment failure rate was statistically significantly low only in patients with filamentary keratitis associated with brain lesions.


Assuntos
Doenças Autoimunes/complicações , Encefalopatias/complicações , Síndromes do Olho Seco/complicações , Traumatismos Oculares/complicações , Ceratite/diagnóstico , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Acetilcisteína/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fluoresceína/administração & dosagem , Seguimentos , Sequestradores de Radicais Livres/administração & dosagem , Humanos , Ceratite/etiologia , Ceratite/terapia , Masculino , Pessoa de Meia-Idade , Indução de Remissão , Estudos Retrospectivos , Fatores de Risco , Soro/fisiologia , Microscopia com Lâmpada de Fenda
9.
Cutan Ocul Toxicol ; 38(4): 315-321, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30741024

RESUMO

Purpose: To compare the therapeutic effects of human derivatives in a mouse alkali burn model. Methods: The right eyes of mice were injured using NaOH. After alkali injury, one of the following agents was topically administered for 7 d: human amniotic membrane (hAM) suspension, human umbilical cord serum (hUCS), and human peripheral blood serum (hPBS), or saline. The epithelial defect areas on days 1, 2, and 3 degrees of opacity on days 2, 3, and 7, and corneal neovascularization (NV) areas on day 7 were evaluated. Histologic examination and mRNA expression levels of tumour necrosis factor (TNF)-α, interleukin (IL)-6, vascular endothelial growth factor (VEGF), matrix metalloproteinase (MMP)-2, MMP-8, and MMP-9 were also evaluated on day 7. Results: The epithelial defect areas in the hUCS group were smaller than those in the control and hPBS groups on day 3 (p < .05, respectively). The epithelial defect areas in the hAM suspension group showed smaller than those in the control and hPBS groups on days 1 and 2 (p < .05, respectively). The degrees of opacity were lower in all treatment groups than that of the saline control group on day 7 (p < .05, respectively). Corneal NV areas were not different among groups on day 7 (p = 0.20). The expression levels of TNF-α, IL-6, MMP-8, and MMP-9 mRNA and the infiltration of the inflammatory cells in all treatment groups were lesser than those in the control group on day 7 (p< .05, respectively). Conclusions: All treatments reduced inflammatory reactions and corneal opacity development. Corneal reepithelialization was faster in the hUCS group.


Assuntos
Âmnio , Queimaduras Químicas/terapia , Neovascularização da Córnea/terapia , Opacidade da Córnea/terapia , Queimaduras Oculares/terapia , Soro , Hidróxido de Sódio/toxicidade , Animais , Queimaduras Químicas/patologia , Córnea/efeitos dos fármacos , Córnea/patologia , Neovascularização da Córnea/patologia , Opacidade da Córnea/patologia , Queimaduras Oculares/induzido quimicamente , Queimaduras Oculares/patologia , Humanos , Masculino , Camundongos Endogâmicos BALB C
10.
Ocul Immunol Inflamm ; 27(4): 614-621, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29420103

RESUMO

Purpose: To report a new surgical procedure using biodegradable collagen matrix (Ologen) implantation with conjunctival flap for reconstruction of scleromalacia after periocular surgery. Methods: A total of 26 areas of 25 eyes in 25 patients were included. We divided all eyes according to the preoperative extent of calcified plaque or scleral defect as follows: small, large, and large and severe. Morphologic outcomes were graded from 0 to 7, with higher scores indicating worse cosmetic outcomes. Results: Mean follow-up period was 8.3 ± 5.6 months. No eyes showed recurrence or specific complications related to Ologen such as implant extrusion or allergic reaction. Minor complications such as flap vessel engorgement and flap hypertrophy were easily treated. Mean morphologic outcome scores were 1.8, 2.4, and 5.3 in groups 1, 2, and 3, respectively. Discussion: The combined surgery may be an effective and safe procedure for the treatment of scleromalacia after periocular surgeries.


Assuntos
Implantes Absorvíveis , Colágeno , Túnica Conjuntiva/transplante , Glicosaminoglicanos , Esclera/cirurgia , Doenças da Esclera/cirurgia , Retalhos Cirúrgicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Pterígio/cirurgia , Reoperação , Estudos Retrospectivos , Doenças da Esclera/diagnóstico , Fatores de Tempo , Resultado do Tratamento
11.
J Korean Med Sci ; 33(27): e180, 2018 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-29962925

RESUMO

BACKGROUND: To analyze the results of court rulings about medical litigations related to cataract surgery in Korea. METHODS: We collected 50 anonymized judgements regarding cataract surgery between 2000 and 2016 and analyzed the reasons for the medical litigations, the court rulings, the reasons for compensation, and the amount claimed and finally awarded. RESULTS: Forty-eight litigations (96%) resulted from errors in treatment, and the reasons were as follows: endophthalmitis, dissatisfaction of visual outcome or ocular discomfort, bullous keratopathy or corneal opacity, retinal detachment, glaucoma or vitreous hemorrhage due to the progression of an underlying diabetic retinopathy, and others in order. Two litigations (4%) arose due to errors in diagnosis. Among the 50 final cases, 21 litigations (42%) were decided in favor of the plaintiff, and 29 litigations (58%) were decided against the plaintiff and dismissed. Ten cases awarded damages to the plaintiffs because of a violation of duty of care, and 11 cases awarded damages due to a violation of informed consent. When comparing cases with errors in diagnosis to cases with errors in treatment, there was no significant difference in the relative risk of a defendant's verdict (P = 0.503). The total amount of awarded damages was KRW 439,124,496 (USD 399,204), and the average amount was KRW 20,910,690 (USD 19,010). CONCLUSION: Nearly half of the cases were decided in favor of the plaintiff due to the violation of informed consent. This study's results will be helpful in understanding the results of medical litigations regarding cataract surgery and reducing future lawsuits.


Assuntos
Extração de Catarata , Catarata , Humanos , Imperícia , Médicos , República da Coreia
12.
PLoS One ; 13(2): e0191857, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29444106

RESUMO

PURPOSE: To evaluate the prevalence and risk factors associated with horizontal strabismus in children and adolescents in South Korea. METHODS: A total of 5,935 children and adolescents 5-18 years of age who participated in the fourth and fifth Korean National Health and Nutrition Examination Survey (KNHANES IV-V) from July 2008 to December 2011 were evaluated and the prevalence of horizontal strabismus was estimated. Univariate and multivariate logistic regression analyses were conducted to determine the association between demographic, socioeconomic and clinical risk factors and clinically significant exodeviation (≥15 prism diopters [PD]) and esodeviation (≥10 PD). RESULTS: Among 5,935 eligible subjects, 84 subjects had clinically significant exodeviation and 13 had clinically significant esodeviation. The overall prevalence of clinically significant horizontal strabismus was 1.6% (95% confidence interval [CI], 1.2-2.1): 1.3% (95% CI, 1.0-1.7) for clinically significant exodeviation and 0.3% (95% CI, 0.1-0.6) for clinically significant esodeviation. Clinically significant exodeviation was associated with amblyopia (adjusted odds ratio [aOR], 6.45; 95% CI, 2.14-19.44), family history of strabismus (aOR, 4.91; 95% CI, 1.71-14.08) and astigmatism ≥1.0 D (aOR, 1.84; 95% CI, 1.13-2.98). Clinically significant esodeviation was associated with hyperopia (aOR, 12.16; 95% CI, 1.31-113.04) and amblyopia (aOR, 4.70; 95% CI, 1.12-19.81). Other demographic, socioeconomic, and clinical variables were not associated with strabismus. CONCLUSION: This study provides data on the prevalence and independent risk factors for clinically significant exodeviation and esodeviation in a representative population of children and adolescents in South Korea.


Assuntos
Estrabismo/epidemiologia , Adolescente , Criança , Feminino , Humanos , Masculino , Inquéritos Nutricionais , República da Coreia/epidemiologia , Fatores de Risco
13.
Indian J Ophthalmol ; 65(1): 59-61, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28300744

RESUMO

We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A) procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD), and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.


Assuntos
Extração de Catarata/métodos , Córtex do Cristalino/cirurgia , Humanos , Sucção/métodos , Irrigação Terapêutica/métodos
14.
J Korean Med Sci ; 32(4): 666-671, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28244295

RESUMO

We evaluated the safety of matrix metalloproteinase (MMP) inhibitor in experimental glaucoma filtration surgery in an animal model. Fifteen New Zealand white rabbits underwent an experimental trabeculectomy and were randomly allocated into 3 groups according to the adjuvant agent: no treatment group (n = 5), 0.02% mitomycin C (MMC) soaking group (n = 5), and MMP inhibitor (ilomastat) subconjunctival injection group (n = 5). Slit lamp examination with Seidel testing, pachymetry, and specular microscopy was performed preoperatively and postoperatively. The conjunctiva and ciliary body toxicity were evaluated with scores according to the pathologic grading systems. Electron microscopy was used to examine the structural changes in cornea, conjunctiva, and ciliary body. In the ilomastat-treated group, there was no statistically significant change in central corneal thickness preoperatively and at 28 days postoperatively (P = 0.655). There were also no significant changes in specular microscopy findings over the duration of the study in the ilomastat-treated group. The conjunctival toxicity score was 1 in the control group, 1.5 in the ilomastat-treated group, and 2 in the MMC-treated group. When assessing ciliary body toxicity scores, the ilomastat-treated group score was 0.5 and the MMC-treated group score was 1.5. Transmission electron microscopy did not show structural changes in the cornea and ciliary body whereas the structural changes were noticed in MMC group. A single subconjunctival injection of MMP inhibitor during the experimental trabeculectomy showed a less toxic affect in the rabbit cornea, conjunctiva, and ciliary body compared to MMC.


Assuntos
Túnica Conjuntiva/efeitos dos fármacos , Glaucoma/cirurgia , Indóis/toxicidade , Inibidores de Metaloproteinases de Matriz/toxicidade , Animais , Corpo Ciliar/efeitos dos fármacos , Corpo Ciliar/fisiologia , Túnica Conjuntiva/fisiologia , Córnea/efeitos dos fármacos , Córnea/fisiologia , Ácidos Hidroxâmicos , Microscopia Eletrônica de Transmissão , Mitomicina/toxicidade , Coelhos , Trabeculectomia
15.
Ann Plast Surg ; 78(6): 613-617, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28177970

RESUMO

PURPOSE: We had reported the surgical outcome of reverse skin redraping technique for restoration of previously performed epicanthoplasty. In this study, we introduce a modified reverse skin redraping technique that added mini-epicanthoplasty in patients with unsatisfactory results after epicanthoplasty. METHODS: Three hundred twenty-four patients (288 female and 36 male patients) who had unsatisfied results with previous epicanthoplasty and that were treated with our modified restoration surgery were included in this study. RESULTS: The mean preoperative interepicanthal distance was 33.6 mm, and the mean postoperative interepicanthal distance was 36.9 mm; the mean difference in the interepicanthal distance before and after restoration surgery was 3.3 mm. Satisfactory aesthetic results were obtained with improvements in areas of asymmetry, overexposure of the caruncle, and the appearance of the previous scar. Only minor complications developed in 15 patients (4.6%) that were resolved with minor revisions. No severe complications requiring reoperations were noted. CONCLUSIONS: Our modified method involving reverse skin redraping and mini-epicanthoplasty is simple and reproducible and is useful for resolution of unsatisfactory results to obtain a naturally shaped epicanthus.


Assuntos
Blefaroplastia/métodos , Pálpebras/cirurgia , Adulto , Povo Asiático , Cicatriz/cirurgia , Estética , Feminino , Humanos , Masculino , Satisfação do Paciente , Reoperação , Resultado do Tratamento
16.
Optom Vis Sci ; 93(3): 259-65, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26760579

RESUMO

PURPOSE: To compare a new optical biometer device, Galilei G6 (Ziemer, Port, Switzerland), with the present optical biometer, Lenstar LS 900 (Haag-Streit, Koeniz, Switzerland), for intraocular lens (IOL) power calculation. METHODS: One hundred forty eyes of 140 cataract patients were evaluated with two optical biometers: the Galilei G6 and the Lenstar. The mean keratometry (K), axial length (AL), anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW), and IOL powers using the SRK/T, Holladay 1, Hoffer Q, and Haigis formulas were compared. The intrasession repeatability of the Galilei G6 measurements was assessed in 25 eyes. RESULTS: All ocular parameters measured by the Galilei G6 were highly repeatable (all intraclass correlation coefficients > 0.980). Although K and ACD did not show statistical differences between the two devices (all p > 0.05), the measurements for AL, LT, and WTW were statistically different for the two devices. The K, AL, ACD, LT, and WTW showed good correlations (r = 0.975, 0.998, 0.973, 0.946, and 0.710, respectively; all p < 0.001); however, the agreements of LT and WTW were not good between the two devices. The IOL powers using four formulas did not show statistical differences (all p > 0.05); however, agreements between the IOL powers were not strong. The ranges of 95% limit of agreements were between 1.54 and 1.90D according to the formulas. CONCLUSIONS: The ocular parameters and IOL powers using the Galilei G6 cannot be used interchangeably with those of the Lenstar in clinical practice.


Assuntos
Biometria/instrumentação , Interferometria/instrumentação , Lentes Intraoculares , Óptica e Fotônica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/anatomia & histologia , Feminino , Humanos , Cristalino/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Prog Retin Eye Res ; 50: 67-88, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26612778

RESUMO

Transforming growth factor beta-induced (TGFBI) corneal dystrophies are a group of inherited progressive corneal diseases. Accumulation of transforming growth factor beta-induced protein (TGFBIp) is involved in the pathogenesis of TGFBI corneal dystrophies; however, the exact molecular mechanisms are not fully elucidated. In this review article, we summarize the current knowledge of TGFBI corneal dystrophies including clinical manifestations, epidemiology, most common and recently reported associated mutations for each disease, and treatment modalities. We review our current understanding of the molecular mechanisms of granular corneal dystrophy type 2 (GCD2) and studies of other TGFBI corneal dystrophies. In GCD2 corneal fibroblasts, alterations of morphological characteristics of corneal fibroblasts, increased susceptibility to intracellular oxidative stress, dysfunctional and fragmented mitochondria, defective autophagy, and alterations of cell cycle were observed. Other studies of mutated TGFBIp show changes in conformational structure, stability and proteolytic properties in lattice and granular corneal dystrophies. Future research should be directed toward elucidation of the biochemical mechanism of deposit formation, the relationship between the mutated TGFBIp and the other materials in the extracellular matrix, and the development of gene therapy and pharmaceutical agents.


Assuntos
Distrofias Hereditárias da Córnea , Fator de Crescimento Transformador beta/metabolismo , Autofagia/fisiologia , Córnea/metabolismo , Distrofias Hereditárias da Córnea/etiologia , Distrofias Hereditárias da Córnea/genética , Distrofias Hereditárias da Córnea/metabolismo , Distrofias Hereditárias da Córnea/terapia , Fibroblastos/patologia , Predisposição Genética para Doença , Humanos , Mutação , Estresse Oxidativo/fisiologia
18.
Am J Ophthalmol ; 157(6): 1144-1150.e1, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24561172

RESUMO

PURPOSE: To evaluate dry eye and meibomian gland dysfunction after cataract surgery. DESIGN: Prospective observational case series. METHODS: We studied 58 eyes of 48 patients who underwent phacoemulsification and evaluated them preoperatively and at 1 month and 3 months postoperatively. Ocular symptom scores, lid margin abnormalities, superficial punctate keratopathies (SPKs), tear film break-up time (TBUT), Schirmer test, lower tear meniscus height, depth, and area using Fourier domain optical coherence tomography, meibum expressibility and images of the meibomian glands using meibography were measured. RESULTS: The ocular symptom scores were worse at 1 month and 3 months postoperatively (P < 0.001 and P < 0.001, respectively). Lid margin abnormalities were significantly increased (P < 0.001 and P < 0.001, respectively) and TBUT decreased postoperatively (P < 0.001 and P < 0.001, respectively). Meibum expressibility decreased at 3 months postoperatively (P = 0.016); however, meibography score, SPK, lower tear meniscus height, depth and area and the Schirmer test did not change significantly postoperatively (all P values >0.05). CONCLUSION: Meibomian gland function may be altered without accompanying structural changes after cataract surgery.


Assuntos
Síndromes do Olho Seco/diagnóstico , Doenças Palpebrais/diagnóstico , Glândulas Tarsais/patologia , Facoemulsificação , Complicações Pós-Operatórias , Idoso , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/fisiopatologia , Doenças Palpebrais/etiologia , Doenças Palpebrais/fisiopatologia , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Lágrimas/química , Acuidade Visual/fisiologia
19.
Yonsei Med J ; 55(1): 197-202, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24339307

RESUMO

PURPOSE: To compare the epithelial wound healing response of two preservative-free fluoroquinolones, moxifloxacin and levofloxacin, in patients who underwent cataract surgery. MATERIALS AND METHODS: In this prospective, evaluator-masked, randomized clinical trial, 59 eyes of 50 patients who underwent cataract surgery were enrolled. Patients were randomized to receive moxifloxacin 0.5% (n=32 eyes) or levofloxacin 0.5% (n=27 eyes). All patients instilled moxifloxacin or levofloxain four times daily for 1 week prior to surgery and 2 weeks after surgery. The epithelial wound healing status in the corneal incision site was scanned with a raster scan mode of fourier-domain optical coherence tomography (FD-OCT). The number of eyes showing epithelial defect images and average number of corneal epithelial defect cuts per eye were compared between groups. All patients were evaluated on postoperative days 1, 2, 3, and 10. RESULTS: On postoperative days 1, 2, and 3, the number of eyes showing epithelial defects in FD-OCT was not statistically different (all p>0.05). The average number of corneal epithelial defect cuts was also not statistically different between the two groups (all p>0.05). No eyes showed epithelial defects on postoperative day 10 in either group. CONCLUSION: There were no differences on epithelial wound healing comparing these two different fluoroquinolones at the incision site of cataract surgery.


Assuntos
Córnea/cirurgia , Fluoroquinolonas/uso terapêutico , Cicatrização/efeitos dos fármacos , Idoso , Compostos Aza/uso terapêutico , Extração de Catarata , Córnea/efeitos dos fármacos , Feminino , Humanos , Levofloxacino/uso terapêutico , Masculino , Pessoa de Meia-Idade , Moxifloxacina , Quinolinas/uso terapêutico , Tomografia de Coerência Óptica
20.
Indian J Ophthalmol ; 62(3): 348-50, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23619497

RESUMO

A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic-haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.


Assuntos
Corpos Estranhos no Olho/etiologia , Lentes Intraoculares , Resinas Sintéticas , Remoção de Dispositivo , Diagnóstico Diferencial , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Desenho de Prótese , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA