Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Heliyon ; 10(5): e27402, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38486745

RESUMO

Salmonella enterica is distributed worldwide and is a common cause of bacterial food poisoning in humans and a serious public health problem. Although duck meat consumption has recently increased in Korea, studies on the epidemiological relationship between S. enterica contamination in duck farms are scarce. Salmonella enterica serovar Albany isolates recovered from duck farms were analyzed using two typing methods - IR Biotyper® (IRBT) and multilocus variable-number tandem repeat analysis (MLVA). The clustering results were compared with the epidemiological survey findings and the antimicrobial resistance profiles. From April 2019 to October 2020, 20 individual feces per farm from 5-6-week-old ducks were collected repeatedly from 105 duck farms. Salmonella spp. isolated from duck feces were identified using PCR and multilocus sequence typing to investigate the prevalence and distribution of the Salmonella serovars. The prevalence of S. enterica was 19%, and S. enterica Albany was the predominantly recovered isolate. The S. enterica Albany isolates underwent antimicrobial susceptibility testing to determine the minimum inhibitory concentration. MLVA and IRBT methods established relatedness and diversity among the S. enterica Albany isolates. Multidrug-resistant S. enterica Albany was distributed in all the farms. Antimicrobial resistance profiles reflected the duck farm characteristics and isolates recovered from the same farm showed an identical profile. Isolates repeatedly recovered from the same farm also showed identical IRBT clusters and MLVA groups. These findings suggest that the isolates remained on the duck farm and re-infected new duck flocks. Thus, proper cleaning and disinfection is required before the farms are repopulated.

2.
Poult Sci ; 103(1): 103197, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37925771

RESUMO

Fungi are pathogens that infect all types of poultry and farmers, leading to economic losses in poultry production. Fungi can be isolated from environmental samples and are ubiquitous in the air. This study aimed to evaluate fungal contamination in domestic duck farm environments and analyze biosecurity risk factors associated with fungal infection incidence to assess the vulnerability of the farms to fungal infection. The average fungal concentration was 203 colony-forming units (CFU)/m3 in the air and 365 × 103 CFU/m2 in the wall surface samples. Sixteen fungal genera were recovered from air and wall surface samples from 19 duck-breeding farms, Aspergillus being the most frequently isolated (air: 43.2%; wall surface: 40%). Eleven additional fungal genera (Acrophialophora, Byssochlamys, Fusarium, Lichtheimia, Paecilomyces, Penicillium, Polycephalomyces, Rhizomucor, Scopulariopsis, Talaromyces, and Thermoascus) were isolated from air samples. Also, 8 additional fungal genera (Chaetomium, Lichtheimia, Penicillium, Petriella, Rhizomucor, Rhizopus, Talaromyces, and Trichosporon) were isolated from wall surface samples. The characteristics of the poultry farms (geographic region, stocking density, breeding house type, affiliate, duck age, and season) and fungal concentrations in the air and wall surface samples were analyzed to evaluate the biosecurity risk of the farms. Fungal infections were significantly affected by high stocking density (>2 ducks/m2), duck age (18-25 wk and >60 wk), and high fungal concentration in the wall surface samples (>300 × 103 CFU/m2).


Assuntos
Patos , Micoses , Animais , Fazendas , Biosseguridade , Galinhas , Melhoramento Vegetal , Aves Domésticas , Micoses/veterinária , Fatores de Risco
3.
J Vet Diagn Invest ; 35(6): 742-750, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37571922

RESUMO

Calf diarrhea results in significant economic loss and is caused by a variety of pathogens, including enteric viruses. Many of these viruses, including bovine norovirus (BNoV), bovine torovirus (BToV), and bovine kobuvirus (BKoV), are recognized as the causative agents of diarrhea; however, they remain understudied as major pathogens. We developed a multiplex reverse-transcription quantitative real-time PCR (RT-qPCR) assay for rapid and simple detection of BNoV, BToV, and BKoV. Our method had high sensitivity and specificity, with detection limits of 1 × 102 copies/µL for BNoV, BToV, and BKoV, which is a lower detection limit than conventional RT-PCR for BNoV and BKoV and identical for BToV. We tested fecal samples from 167 diarrheic calves with our multiplex RT-qPCR method. Viral detection was superior to conventional RT-PCR methods in all samples. The diagnostic sensitivity of the multiplex RT-qPCR method (100%) is higher than that of the conventional RT-PCR methods (87%). Our assay can detect BNoV, BToV, and BKoV in calf feces rapidly and with high sensitivity and specificity.


Assuntos
Doenças dos Bovinos , Kobuvirus , Norovirus , Torovirus , Animais , Bovinos , Torovirus/genética , Norovirus/genética , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Kobuvirus/genética , Diarreia/diagnóstico , Diarreia/veterinária , Fezes , Doenças dos Bovinos/diagnóstico
4.
Sensors (Basel) ; 23(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36772271

RESUMO

A complementary metal-oxide-semiconductor (CMOS) detector array is proposed to improve the sub-terahertz imaging resolution for objects in the conveyor belt system. The image resolution is limited to the implemented configuration, such as the wide spacing in the detector array, the high conveyor belt speed, and the slow response of the signal conditioning block. The proposed array can improve the image resolution in the direction perpendicular to the movement of the belt, which is determined by the size and interval of the detector pixel, by configuring the array into two replaceable columns located at the misaligned horizontal positions. Replaceable detector unit pixels are individually attached to the motherboard after measuring and evaluating the detection performance to construct the proposed array. The intensities of 32 detector pixels placed under the conveyor belt with a width of 160 mm were initially calibrated in every image, including the beam pattern of 0.2 THz signals generated from the gyrotron. The image resolution of the perpendicular direction obtained from the proposed array was measured to be approximately 5 mm at a conveyor belt speed of 16 mm/s, demonstrating a 200% improvement in resolution compared to the conventional linear array under the same conditions.

5.
Sensors (Basel) ; 22(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35270903

RESUMO

A CMOS detector with a concurrent mode for high-quality images in the sub-terahertz region has been proposed. The detector improves output-signal coupling characteristics at the output node. A cross-coupling capacitor is added to isolate the DC bias between the drain and gate. The detector is designed to combine a 180° phase shift based on common source operation and an in-phase output signal based on the drain input. The circuit layout and phase shift occurring in the cross-coupled capacitor during phase coupling are verified using an EM simulation. The detector is fabricated using the TSMC 0.25-µm mixed-signal 1-poly 5-metal layer CMOS process, where the size, including the pad, is 1.13 mm × 0.74 mm. The detector IC comprises a folded dipole antenna, the proposed detector, a preamplifier, and a voltage buffer. Measurement results using a 200-GHz gyrotron source demonstrate that the proposed detector voltage responsivity is 14.13 MV/W with a noise-equivalent power of 34.42 pW/√Hz. The high detection performance helps resolve the 2-mm line width. The proposed detector exhibits a signal-to-noise ratio of 49 dB with regard to the THz imaging performance, which is 9 dB higher than that of the previous CMOS detector core circuits with gate-drain capacitors.

6.
Rev Sci Instrum ; 92(1): 014702, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514232

RESUMO

Spark gap switches are used in various high-power pulse systems because they can quickly transfer the energy stored in the capacitor to the load. A rotary trigger double spark gap (RTDSG) switch is proposed in this paper as a type of switch capable of high repetition at high power. It was found that a pulse switching of 20 kV and 1 kHz was possible by applying the multiple RTDSG switches to increase the repetition rate of the switch. In addition to the basic operating principle of the RTDSG, the effects of switching-related parameters on the operating frequency of the switch were analyzed. As an example of promising applications of the high repetition RTDSG, the generation of shock waves by underwater discharge and the effective dispersion of carbon nanotubes using the shock waves are reported.

7.
Sci Rep ; 7(1): 16830, 2017 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-29203788

RESUMO

Terahertz (THz) detectors have been extensively studied for various applications such as security, wireless communication, and medical imaging. In case of metal-insulator-metal (MIM) tunnel junction THz detector, a small junction area is desirable because the detector response time can be shortened by reducing it. An edge metal-semiconductor-metal (EMSM) junction has been developed with a small junction area controlled precisely by the thicknesses of metal and semiconductor films. The voltage response of the EMSM THz detector shows the clear dependence on the polarization angle of incident THz wave and the responsivity is found to be very high (~2,169 V/W) at 0.4 THz without any antenna and signal amplifier. The EMSM junction structure can be a new and efficient way of fabricating the nonlinear device THz detector with high cut-off frequency relying on extremely small junction area.

8.
Sensors (Basel) ; 17(9)2017 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-28891927

RESUMO

We propose a differential-type complementary metal-oxide-semiconductor (CMOS) sub-terahertz (THz) detector with a subthreshold preamplifier. The proposed detector improves the voltage responsivity and effective signal-to-noise ratio (SNR) using the subthreshold preamplifier, which is located between the differential detector device and main amplifier. The overall noise of the detector for the THz imaging system is reduced by the preamplifier because it diminishes the noise contribution of the main amplifier. The subthreshold preamplifier is self-biased by the output DC voltage of the detector core and has a dummy structure that cancels the DC offsets generated by the preamplifier itself. The 200 GHz detector fabricated using 0.25 µm CMOS technology includes a low drop-out regulator, current reference blocks, and an integrated antenna. A voltage responsivity of 2020 kV/W and noise equivalent power of 76 pW/√Hz are achieved using the detector at a gate bias of 0.5 V, respectively. The effective SNR at a 103 Hz chopping frequency is 70.9 dB with a 0.7 W/m² input signal power density. The dynamic range of the raster-scanned THz image is 44.59 dB.

9.
Sensors (Basel) ; 16(3)2016 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-26950128

RESUMO

A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS) detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size including an integrated antenna is comparable to the wavelength of the THz wave for the imaging system, inevitably carries wide pixel-to-pixel variation. To make the variant outputs from the array uniform, the proposed signal conditioning block calibrates the responsivity of each pixel by controlling the gate bias of each detector and the voltage gain of the lock-in amplifiers in the block. The gate bias of each detector is modulated to 1 MHz to improve the signal-to-noise ratio of the imaging system via the electrical modulation by the conditioning block. In addition, direct current (DC) offsets of the detectors in the array are cancelled by initializing the output voltage level from the block. Real-time imaging using the proposed signal conditioning block is demonstrated by obtaining images at the rate of 19.2 frame-per-sec of an object moving on the conveyor belt with a scan width of 20 cm and a scan speed of 25 cm/s.

10.
Opt Express ; 22(23): 28977-83, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402136

RESUMO

We demonstrate real-time continuous-wave terahertz (THz) line-scanned imaging based on a 1 × 240 InGaAs Schottky barrier diode (SBD) array detector with a scan velocity of 25 cm/s, a scan line length of 12 cm, and a pixel size of 0.5 × 0.5 mm². Foreign substances, such as a paper clip with a spatial resolution of approximately 1 mm that is hidden under a cracker, are clearly detected by this THz line-scanning system. The system consists of the SBD array detector, a 200-GHz gyrotron source, a conveyor system, and several optical components such as a high-density polyethylene cylindrical lens, metal cylindrical mirror, and THz wire-grid polarizer. Using the THz polarizer, the signal-to-noise ratio of the SBD array detector improves because the quality of the source beam is enhanced.


Assuntos
Arsenicais/química , Sistemas Computacionais , Eletrônica/instrumentação , Gálio/química , Índio/química , Fenômenos Ópticos , Radiação Terahertz
11.
J Food Prot ; 75(1): 179-83, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22221375

RESUMO

Foreign bodies (FBs) in food are health hazards and quality issues for many food manufacturers and enforcement authorities. In this study, continuous wave (CW) terahertz (THz) imaging at 0.2 THz with an output power of 10 mW was compared with X-ray imaging as techniques for inspection of food for FBs. High-density FBs, i.e., aluminum and granite pieces of various sizes, were embedded in a powdered instant noodle product and detected using THz and X-ray imaging. All aluminum and granite pieces (regular hexahedrons with an edge length of 1 to 5 mm) were visualized by both CW THz and X-ray imaging. THz imaging also detected maggots (length = 8 to 22 mm) and crickets (length = 35 and 50 mm), which were embedded in samples as low density FBs. However, not all sizes of maggot pieces embedded in powdered instant noodle were detected with X-ray imaging, although larger crickets (length = 50 mm and thickness = 10 mm) were detected. These results suggest that CW THz imaging has potential for detecting both high-density and low-density FBs embedded in food.


Assuntos
Contaminação de Alimentos/análise , Inspeção de Alimentos/instrumentação , Inspeção de Alimentos/métodos , Imagem Terahertz/métodos , Animais , Corpos Estranhos , Gryllidae , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Larva
12.
IEEE Trans Electron Devices ; 38(6): 1150-1159, 2010 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-23761938

RESUMO

The design, operation, and characterization of a continuous-wave (CW) tunable second-harmonic 460-GHz gyrotron are reported. The gyrotron is intended to be used as a submillimeter-wave source for 700-MHz nuclear magnetic resonance experiments with sensitivity enhanced by dynamic nuclear polarization. The gyrotron operates in the whispering-gallery mode TE11,2 and has generated 16 W of output power with a 13-kV 100-mA electron beam. The start oscillation current measured over a range of magnetic field values is in good agreement with theoretical start currents obtained from linear theory for successive high-order axial modes TE11,2,q. The minimum start current is 27 mA. Power and frequency tuning measurements as a function of the electron cyclotron frequency have also been carried out. A smooth frequency tuning range of 1 GHz was obtained for the operating second-harmonic mode either by magnetic field tuning or beam voltage tuning. Long-term CW operation was evaluated during an uninterrupted period of 48 h, where the gyrotron output power and frequency were kept stable to within ±0.7% and ±6 ppm, respectively, by a computerized control system. Proper operation of an internal quasi-optical mode converter implemented to transform the operating whispering-gallery mode to a Gaussian-like beam was also verified. Based on the images of the gyrotron output beam taken with a pyroelectric camera, the Gaussian-like mode content of the output beam was computed to be 92% with an ellipticity of 12%.

13.
IEEE Trans Plasma Sci IEEE Nucl Plasma Sci Soc ; 38(6): 1150-1160, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21243088

RESUMO

The design, operation, and characterization of a continuous-wave (CW) tunable second-harmonic 460-GHz gyrotron are reported. The gyrotron is intended to be used as a submillimeter-wave source for 700-MHz nuclear magnetic resonance experiments with sensitivity enhanced by dynamic nuclear polarization. The gyrotron operates in the whispering-gallery mode TE(11,2) and has generated 16 W of output power with a 13-kV 100-mA electron beam. The start oscillation current measured over a range of magnetic field values is in good agreement with theoretical start currents obtained from linear theory for successive high-order axial modes TE(11,2,q). The minimum start current is 27 mA. Power and frequency tuning measurements as a function of the electron cyclotron frequency have also been carried out. A smooth frequency tuning range of 1 GHz was obtained for the operating second-harmonic mode either by magnetic field tuning or beam voltage tuning. Long-term CW operation was evaluated during an uninterrupted period of 48 h, where the gyrotron output power and frequency were kept stable to within ±0.7% and ±6 ppm, respectively, by a computerized control system. Proper operation of an internal quasi-optical mode converter implemented to transform the operating whispering-gallery mode to a Gaussian-like beam was also verified. Based on the images of the gyrotron output beam taken with a pyroelectric camera, the Gaussian-like mode content of the output beam was computed to be 92% with an ellipticity of 12%.

14.
Artigo em Inglês | MEDLINE | ID: mdl-19081779

RESUMO

Gyrotrons operating in the millimeter and submillimeter wavelength ranges are the promising sources for applications that are requiring good spectral characteristics and a wide range of output power. We report the precise measurement results of gyrotron spectra. Experiments were conducted using a 140-GHz long-pulse gyrotron that is developed for the dynamic nuclear polarization/nuclear-magnetic-resonance spectroscopy at the Massachusetts Institute of Technology. Transient downshift of the frequency by 12 MHz with a time constant of 3 s was observed. After reaching equilibrium, the frequency was maintained within 1 ppm for over 20 s. The coefficient of the frequency change with cavity temperature was -2.0 MHz/K, which shows that fine tuning of the gyrotron frequency is plausible by cavity-temperature control. Frequency pulling by the beam current was observed, but it was shown to be masked by the downward shift of the gyrotron frequency with temperature. The linewidth was measured to be much less than 1 MHz at 60 dB relative to the carrier power [in decibels relative to carrier (dBc)] and 4.3 MHz at 75 dBc, which is the largest dynamic range to date for the measurement of gyrotron linewidth to our knowledge.

15.
Proc SPIE Int Soc Opt Eng ; 6373: 63730C, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17404605

RESUMO

Recently, dynamic nuclear polarization enhanced nuclear magnetic resonance (DNP/NMR) has emerged as a powerful technique to obtain significant enhancements in spin spectra from biological samples. For DNP in modern NMR systems, a high power continuous-wave source in the submillimeter wavelength range is necessary. Gyrotrons can deliver tens of watts of CW power at submillimeter wavelengths and are well suited for use in DNP/NMR spectrometers. To date, 140 GHz and 250 GHz gyrotrons are being employed in DNP spectrometer experiments at 200 MHz and 380 MHz at MIT. A 460 GHz gyrotron, which has operated with 8 W of CW output power, will soon be installed in a 700 MHz NMR spectrometer. High power radiation with good spectral and spatial resolution from these gyrotrons should provide NMR spectrometers with high signal enhancement through DNP. Also, these tubes operating at submillimeter wavelengths should have important applications in research in physics, chemistry, biology, materials science and medicine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA