Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Clin Med ; 13(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38731083

RESUMO

Background: Long-term rhythm monitoring (LTRM) can detect undiagnosed atrial fibrillation (AF) in patients at risk of AF and stroke. Circulating microRNAs (miRNAs), which have been shown to play a role in atrial electrical and structural remodelling, could help to select patients who would benefit most from LTRM. The aim of this study was to investigate whether patients with diabetes mellitus (DM) and hypertension and screen-detected subclinical AF (SCAF) using an insertable cardiac monitor (ICM) have significantly different plasma baseline levels of five selected miRNAs playing a role in the modulation of atrial electrical and structural remodelling (miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p) compared to those without SCAF. Methods: This study was performed at the outpatient clinic of a secondary academic teaching hospital between December 2013 and November 2015. Eligible patients were ≥65 years of age with DM and hypertension but without known heart diseases. All patients received an ICM. On the day of ICM implantation, blood samples for the measurement of plasma levels of the five miRNAs were drawn. In this post hoc analysis, we investigated their expression by reverse transcription-quantitative polymerase chain reaction. MiRNA plasma levels in patients with and without newly detected SCAF were compared. Results: We included 82 consecutive patients (median age of 71.3 years (IQR 67.4-75.1)), who were followed for a median of 588 days (IQR: 453-712 days). Seventeen patients (20.7%) had ICM-detected SCAF. Plasma levels of miR-328-3p, miR-29b-3p, miR-21-5p, miR-432-5p, and miR-150-5p were slightly but not significantly different in patients with incident SCAF compared with patients without. Conclusions: In patients with hypertension and DM, newly detected SCAF was not significantly associated with changes in expression levels of miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p.

3.
Life (Basel) ; 13(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36983848

RESUMO

Giant cell arteritis (GCA) is an ophthalmological emergency that can be difficult to diagnose and prompt treatment is vital. We investigated the sequential diagnostic value for patients with suspected GCA using three biochemical measures as they arrive to the clinician: first, platelet count, then C-reactive protein (CRP), and lastly, erythrocyte sedimentation rate (ESR). This retrospective cross-sectional study of consecutive patients with suspected GCA investigated platelet count, CRP, and ESR using diagnostic test accuracy statistics and odds ratios (ORs) in a sequential fashion. The diagnosis was established by experts at follow-up, considering clinical findings and tests including temporal artery biopsy. A total of 94 patients were included, of which 37 (40%) were diagnosed with GCA. Compared with those without GCA, patients with GCA had a higher platelet count (p < 0.001), CRP (p < 0.001), and ESR (p < 0.001). Platelet count demonstrated a low sensitivity (38%) and high specificity (88%); CRP, a high sensitivity (86%) and low specificity (56%); routine ESR, a high sensitivity (89%) and low specificity (47%); and age-adjusted ESR, a moderate sensitivity (65%) and moderate specificity (65%). Sequential analysis revealed that ESR did not provide additional value in evaluating risk of GCA. Initial biochemical evaluation can be based on platelet count and CRP, without waiting for ESR, which allows faster initial decision-making in GCA.

4.
Neuroophthalmology ; 46(6): 383-389, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36544584

RESUMO

With normal retinal blood flow, cross-sectional optical coherence tomography (OCT) of retinal vessels shows a structured intravascular reflectivity profile, resembling a 'figure-of-8'. Altered profiles have been reported in vascular occlusive and haematological diseases. Giant cell arteritis (GCA) can cause visual loss, usually due to anterior ischaemic optic neuropathy (AION) or retinal artery occlusion. Our aim was to extend the assessment of OCT vascular profiles to patients with suspected GCA and to determine if any abnormalities were related to GCA per se or to ischaemic ocular conditions. This nested retrospective study included 61 eyes of 31 patients (13 with GCA). Six eyes had arteritic and seven eyes non-arteritic AION, three eyes had non-arteritic retinal artery occlusion, 11 eyes had other ocular conditions and 34 were unaffected control eyes. For each eye the appearance of structured intravascular profiles on peripapillary OCT was graded as present, partial, absent or uncertain. Non-presence of structured intravascular profiles was more frequent in AION and retinal artery occlusion than in other ocular conditions or unaffected eyes (Fisher's test, p = .0047). Based on follow-up of 25 eyes, reflectivity profiles normalised in three out of four eyes after 85 (35-245) days. Vessel profiles were not associated with GCA (p = .32) and were similar in arteritic and non-arteritic AION (p = .66). In conclusion, absence of structured intravascular reflectivity profiles may be a marker of acute ischaemia in the anterior optic nerve or inner retina. However, it did not seem specific for GCA. The prognostic value warrants further studies.

5.
J Clin Med ; 11(15)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35956052

RESUMO

Cushing's syndrome is a rare disease with an endogenous cause of excess cortisol secretion. More evidence substantially links cortisol levels to the pachychoroid spectrum diseases. In this systematic review and meta-analysis, we summarize available evidence on pachychoroid spectrum diseases in patients with Cushing's syndrome. We performed a systematic literature search in 11 databases on 21 May 2022. Studies were considered eligible if they performed retinal examination of a consecutive group of patients with Cushing's syndrome using optical coherence tomography (OCT) scans. We extracted data on subfoveal choroidal thickness in patients with Cushing's syndrome compared to matched controls. We also extracted data on the prevalence of pachychoroid pigment epitheliopathy (PPE), central serous chorioretinopathy (CSC), and polypoidal choroidal vasculopathy (PCV). We identified six eligible studies with a total of 159 patients with Cushing's syndrome. On average, patients with Cushing's syndrome have 49.5 µm thicker subfoveal choroidal thickness compared to matched healthy individuals. Pachychoroid spectrum diseases were relatively common in these patients: PPE in 20.8%, CSC in 7.7%, and PCV in 2.8%. We conclude that there should be low threshold to recommend ophthalmic examination to patients with Cushing's syndrome, and that a macular OCT is recommended during this examination.

6.
Sci Data ; 9(1): 152, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35383186

RESUMO

Improving speed and image quality of Magnetic Resonance Imaging (MRI) using deep learning reconstruction is an active area of research. The fastMRI dataset contains large volumes of raw MRI data, which has enabled significant advances in this field. While the impact of the fastMRI dataset is unquestioned, the dataset currently lacks clinical expert pathology annotations, critical to addressing clinically relevant reconstruction frameworks and exploring important questions regarding rendering of specific pathology using such novel approaches. This work introduces fastMRI+, which consists of 16154 subspecialist expert bounding box annotations and 13 study-level labels for 22 different pathology categories on the fastMRI knee dataset, and 7570 subspecialist expert bounding box annotations and 643 study-level labels for 30 different pathology categories for the fastMRI brain dataset. The fastMRI+ dataset is open access and aims to support further research and advancement of medical imaging in MRI reconstruction and beyond.


Assuntos
Encéfalo , Processamento de Imagem Assistida por Computador , Articulação do Joelho , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética
7.
Proc Mach Learn Res ; 193: 489-511, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37008682

RESUMO

Accelerated MRI reconstructs images of clinical anatomies from sparsely sampled signal data to reduce patient scan times. While recent works have leveraged deep learning to accomplish this task, such approaches have often only been explored in simulated environments where there is no signal corruption or resource limitations. In this work, we explore augmentations to neural network MRI image reconstructors to enhance their clinical relevancy. Namely, we propose a ConvNet model for detecting sources of image artifacts that achieves a classifier F 2 score of 79.1%. We also demonstrate that training reconstructors on MR signal data with variable acceleration factors can improve their average performance during a clinical patient scan by up to 2%. We offer a loss function to overcome catastrophic forgetting when models learn to reconstruct MR images of multiple anatomies and orientations. Finally, we propose a method for using simulated phantom data to pre-train reconstructors in situations with limited clinically acquired datasets and compute capabilities. Our results provide a potential path forward for clinical adaptation of accelerated MRI.

8.
Pacing Clin Electrophysiol ; 45(1): 35-42, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34739729

RESUMO

BACKGROUND: Long-term rhythm monitoring (LTRM) can detect undiagnosed atrial fibrillation (AF) in patients at high risk of AF and stroke. Biomarkers and echocardiographic parameters could, however, help identify patients benefitting most from LTRM. The aim of this study was to investigate, whether circulating biomarkers of cardiac and vascular function (brain natriuretic peptide (BNP), cardiac troponin I (cTnI), copeptin, and mid-regional proadrenomedullin (MR-proADM)) and echocardiographic parameters were associated with incident subclinical AF (SCAF) in a population at high risk of stroke in the presence of AF. For this purpose, we investigated individuals ≥65 years of age with hypertension and diabetes mellitus, but no history or symptoms of AF or other cardiovascular disease (CVD). METHODS: We included 82 consecutive patients (median age 71.3 years (IQR 67.4-75.1)). All patients received an insertable cardiac monitor (ICM) and were followed for a median of 588 days (IQR 453-712). On the day of ICM implantation, a comprehensive echocardiogram and blood samples were obtained. RESULTS: During a median follow-up of 588 days (IQR: 453-712 days), incident SCAF occurred in 17 patients (20.7%) with a median time to first-detected episode of 91 days (IQR 41-251 days). MR-proADM (median 0.87 nmol/L (IQR 0.76-1.02) vs 0.78 nmol/L (IQR 0.68-0.98)) and copeptin (median 13 pmol/L (IQR 9-17) vs 8 pmol/L (IQR 4-18)) levels were insignificantly higher in patients with incident SCAF. BNP and cTnI concentrations and echocardiographic parameters were similar in the two groups. CONCLUSIONS: MR-proADM, BNP, cTnI, copeptin, and several echocardiographic parameters were not associated with incident SCAF in this cohort of patients with hypertension and diabetes, but without any underlying CVD.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico por imagem , Biomarcadores/sangue , Complicações do Diabetes/sangue , Complicações do Diabetes/diagnóstico por imagem , Ecocardiografia , Hipertensão/complicações , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco
9.
J Hypertens ; 39(4): 607-613, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201052

RESUMO

OBJECTIVE: Aortic pulse pressure (PP) represents the hemodynamic cardiac and cerebral burden more directly than cuff PP. The objective of this study was to investigate whether invasively measured aortic PP confers additional prognostic value beyond cuff PP for cardiovascular events and death. With increasing age, cuff PP progressively underestimates aortic PP. Whether the prognostic association between cuff PP and outcomes is age-dependent remains to be elucidated. METHODS: Cuff PP and invasively measured aortic PP were recorded in 21 908 patients (mean age 63 years, 58% men, 14% with diabetes) with stable angina pectoris undergoing elective coronary angiography during January 2001--December 2012. Multivariate Cox models were used to assess the association with incident myocardial infarction, stroke, and death. Discrimination was assessed using Harrell's C-index. RESULTS: During a median follow-up period of 3.7 years (range 0.1-10.8 years), 422 strokes, 511 myocardial infarctions, and 1530 deaths occurred. Both cuff and aortic PP were associated with stroke, myocardial infarction, and death in crude analyses. However, only cuff PP remained associated with stroke (hazard ratio per 10 mmHg, 1.06 (95% confidence interval (CI) 1.01--1.12)] and myocardial infarction [hazard ratio per 10 mmHg 1.05 (95% CI 1.01--1.11)] in multivariate Cox models. Both cuff and aortic PP lost significance as predictors of death in multivariate models. Age did not modify the prognostic association between cuff PP and stroke, myocardial infarction, and death. CONCLUSION: Invasively measured aortic PP did not add prognostic information about cardiovascular outcomes and death beyond cuff PP in patients with stable angina pectoris.


Assuntos
Pressão Arterial , Doenças Cardiovasculares , Pressão Sanguínea , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
10.
Radiology ; 293(2): 384-393, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31573398

RESUMO

Background Commercial low-field-strength MRI systems are generally not equipped with state-of-the-art MRI hardware, and are not suitable for demanding imaging techniques. An MRI system was developed that combines low field strength (0.55 T) with high-performance imaging technology. Purpose To evaluate applications of a high-performance low-field-strength MRI system, specifically MRI-guided cardiovascular catheterizations with metallic devices, diagnostic imaging in high-susceptibility regions, and efficient image acquisition strategies. Materials and Methods A commercial 1.5-T MRI system was modified to operate at 0.55 T while maintaining high-performance hardware, shielded gradients (45 mT/m; 200 T/m/sec), and advanced imaging methods. MRI was performed between January 2018 and April 2019. T1, T2, and T2* were measured at 0.55 T; relaxivity of exogenous contrast agents was measured; and clinical applications advantageous at low field were evaluated. Results There were 83 0.55-T MRI examinations performed in study participants (45 women; mean age, 34 years ± 13). On average, T1 was 32% shorter, T2 was 26% longer, and T2* was 40% longer at 0.55 T compared with 1.5 T. Nine metallic interventional devices were found to be intrinsically safe at 0.55 T (<1°C heating) and MRI-guided right heart catheterization was performed in seven study participants with commercial metallic guidewires. Compared with 1.5 T, reduced image distortion was shown in lungs, upper airway, cranial sinuses, and intestines because of improved field homogeneity. Oxygen inhalation generated lung signal enhancement of 19% ± 11 (standard deviation) at 0.55 T compared with 7.6% ± 6.3 at 1.5 T (P = .02; five participants) because of the increased T1 relaxivity of oxygen (4.7e-4 mmHg-1sec-1). Efficient spiral image acquisitions were amenable to low field strength and generated increased signal-to-noise ratio compared with Cartesian acquisitions (P < .02). Representative imaging of the brain, spine, abdomen, and heart generated good image quality with this system. Conclusion This initial study suggests that high-performance low-field-strength MRI offers advantages for MRI-guided catheterizations with metal devices, MRI in high-susceptibility regions, and efficient imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Grist in this issue.


Assuntos
Cateterismo , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Adulto , Artefatos , Cateterismo Cardíaco/instrumentação , Meios de Contraste , Desenho de Equipamento , Feminino , Humanos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Metais , Razão Sinal-Ruído
11.
MAGMA ; 32(2): 213-225, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30361947

RESUMO

INTRODUCTION: Computationally intensive image reconstruction algorithms can be used online during MRI exams by streaming data to remote high-performance computers. However, data acquisition rates often exceed the bandwidth of the available network resources creating a bottleneck. Data compression is, therefore, desired to ensure fast data transmission. METHODS: The added noise variance due to compression was determined through statistical analysis for two compression libraries (one custom and one generic) that were implemented in this framework. Limiting the compression error variance relative to the measured thermal noise allowed for image signal-to-noise ratio loss to be explicitly constrained. RESULTS: Achievable compression ratios are dependent on image SNR, user-defined SNR loss tolerance, and acquisition type. However, a 1% reduction in SNR yields approximately four to ninefold compression ratios across MRI acquisition strategies. For free-breathing cine data reconstructed in the cloud, the streaming bandwidth was reduced from 37 to 6.1 MB/s, alleviating the network transmission bottleneck. CONCLUSION: Our framework enabled data compression for online reconstructions and allowed SNR loss to be constrained based on a user-defined SNR tolerance. This practical tool will enable real-time data streaming and greater than fourfold faster cloud upload times.


Assuntos
Compressão de Dados/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Compressão de Dados/estatística & dados numéricos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imagem Cinética por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Imagens de Fantasmas , Razão Sinal-Ruído , Software
12.
J Cardiovasc Magn Reson ; 19(1): 91, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29162123

RESUMO

BACKGROUND: Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby increasing the contrast between the endocardium and blood. The objective of this study is to compare the diagnostic utility of a novel DB phase sensitive inversion recovery (PSIR) LGE CMR sequence to standard bright blood PSIR LGE. METHODS: One hundred seventy-two patients referred for clinical CMR were scanned. A full left ventricle short axis stack was performed using both techniques, varying which was performed first in a 1:1 ratio. Two experienced observers analyzed all bright blood LGE and DB LGE stacks, which were randomized and anonymized. A scoring system was devised to quantify the presence and extent of gadolinium enhancement and the confidence with which the diagnosis could be made. RESULTS: A total of 2752 LV segments were analyzed. There was very good inter-observer correlation for quantifying LGE. DB LGE analysis found 41.5% more segments that exhibited hyperenhancement in comparison to bright blood LGE (248/2752 segments (9.0%) positive for LGE with bright blood; 351/2752 segments (12.8%) positive for LGE with DB; p < 0.05). DB LGE also allowed observers to be more confident when diagnosing LGE (bright blood LGE high confidence in 154/248 regions (62.1%); DB LGE in 275/324 (84.9%) regions (p < 0.05)). Eighteen patients with no bright blood LGE were found to have had DB LGE, 15 of whom had no known history of myocardial infarction. CONCLUSIONS: DB LGE significantly increases LGE detection compared to standard bright blood LGE. It also increases observer confidence, particularly for subendocardial LGE, which may have important clinical implications.


Assuntos
Cicatriz/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Meglumina/administração & dosagem , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Cicatriz/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
J Cardiovasc Magn Reson ; 19(1): 78, 2017 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-29047385

RESUMO

BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N-NH3 cardiac positron emission tomography (PET) as the reference method. METHODS: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N-NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. RESULTS: There was good agreement between global MP quantified by PET and CMR both at stress (-0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (-0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). CONCLUSIONS: There is good agreement between MP quantified by 13N-NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Idoso , Circulação Coronária/fisiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
14.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28874164

RESUMO

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias/diagnóstico , Imagem por Ressonância Magnética Intervencionista , Exposição à Radiação/prevenção & controle , Adolescente , Fatores Etários , Criança , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Fatores de Tempo
15.
J Cardiovasc Magn Reson ; 19(1): 54, 2017 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-28750642

RESUMO

BACKGROUND: Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. METHODS: One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RESULTS: RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement -38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was -0.02 WU.m2 with limits of agreement -2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CONCLUSIONS: CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. TRIAL REGISTRATION: Clinicaltrials.gov NCT01287026 , registered January 25, 2011.


Assuntos
Cateterismo Cardíaco , Débito Cardíaco , Hipertensão Pulmonar/diagnóstico por imagem , Imagem por Ressonância Magnética Intervencionista , Artéria Pulmonar/fisiopatologia , Resistência Vascular , Administração por Inalação , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Fluoroscopia , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Óxido Nítrico/administração & dosagem , Oxigênio/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
16.
J Cardiovasc Magn Reson ; 19(1): 43, 2017 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-28385161

RESUMO

BACKGROUND: Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. METHODS: A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. RESULTS: For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19 ml/min/g using the BTEX model and 3.4 ± 0.39 and 0.95 ± 0.16 using a Fermi model, for stress and rest, respectively. CONCLUSIONS: A dual sequence for myocardial perfusion cardiovascular magnetic resonance and AIF measurement has been optimized for quantification of myocardial blood flow. A validation in phantoms was performed to confirm that the signal conversion to gadolinium concentration was linear. The proposed sequence was integrated with a fully automatic in-line solution for pixel-wise mapping of myocardial blood flow and evaluated in adenosine stress and rest studies on N = 29 normal healthy subjects. Reliable perfusion mapping was demonstrated and produced estimates with low variability.


Assuntos
Circulação Coronária , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Automação , Velocidade do Fluxo Sanguíneo , Meios de Contraste/administração & dosagem , Voluntários Saudáveis , Humanos , Imagem de Perfusão do Miocárdio/instrumentação , Dinâmica não Linear , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Vasodilatadores/administração & dosagem
17.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28245348

RESUMO

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Assuntos
Ablação por Cateter , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Taquicardia Ventricular/cirurgia , Adolescente , Fatores Etários , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
18.
Magn Reson Med ; 77(1): 411-421, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26822475

RESUMO

PURPOSE: This work proposes the ISMRM Raw Data format as a common MR raw data format, which promotes algorithm and data sharing. METHODS: A file format consisting of a flexible header and tagged frames of k-space data was designed. Application Programming Interfaces were implemented in C/C++, MATLAB, and Python. Converters for Bruker, General Electric, Philips, and Siemens proprietary file formats were implemented in C++. Raw data were collected using magnetic resonance imaging scanners from four vendors, converted to ISMRM Raw Data format, and reconstructed using software implemented in three programming languages (C++, MATLAB, Python). RESULTS: Images were obtained by reconstructing the raw data from all vendors. The source code, raw data, and images comprising this work are shared online, serving as an example of an image reconstruction project following a paradigm of reproducible research. CONCLUSION: The proposed raw data format solves a practical problem for the magnetic resonance imaging community. It may serve as a foundation for reproducible research and collaborations. The ISMRM Raw Data format is a completely open and community-driven format, and the scientific community is invited (including commercial vendors) to participate either as users or developers. Magn Reson Med 77:411-421, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos , Bases de Dados Factuais , Imagens de Fantasmas , Razão Sinal-Ruído
19.
Magn Reson Med ; 77(2): 673-683, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26899165

RESUMO

PURPOSE: A new real-time MR-thermometry pipeline was developed to measure multiple temperature images per heartbeat with 1.6×1.6×3 mm3 spatial resolution. The method was evaluated on 10 healthy volunteers and during radiofrequency ablation (RFA) in sheep. METHODS: Multislice, electrocardiogram-triggered, echo-planar imaging was combined with parallel imaging, under free breathing conditions. In-plane respiratory motion was corrected on magnitude images by an optical flow algorithm. Motion-related susceptibility artifacts were compensated on phase images by an algorithm based on Principal Component Analysis. Correction of phase drift and temporal filter were included in the pipeline implemented in the Gadgetron framework. Contact electrograms were recorded simultaneously with MR thermometry by an MR-compatible ablation catheter. RESULTS: The temporal standard deviation of temperature in the left ventricle remained below 2 °C on each volunteer. In sheep, focal heated regions near the catheter tip were observed on temperature images (maximal temperature increase of 38 °C) during RFA, with contact electrograms of acceptable quality. Thermal lesion dimensions at gross pathology were in agreement with those observed on thermal dose images. CONCLUSION: This fully automated MR thermometry pipeline (five images/heartbeat) provides direct assessment of lesion formation in the heart during catheter-based RFA, which may improve treatment of cardiac arrhythmia by ablation. Magn Reson Med 77:673-683, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Ablação por Cateter/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Termometria/métodos , Adulto , Algoritmos , Animais , Arritmias Cardíacas/cirurgia , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Ovinos , Processamento de Sinais Assistido por Computador
20.
Semin Arthritis Rheum ; 46(6): 699-708, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27769592

RESUMO

OBJECTIVES: To summarize and compare the benefits and harms of biological agents used as monotherapy for rheumatoid arthritis (RA) in order to inform decisions for patients who are intolerant to conventional DMARD therapy. METHODS: We searched MEDLINE, EMBASE, CENTRAL, and other sources for randomised trials that compared biological monotherapy with methotrexate, placebo, or other biological monotherapies. Primary outcomes were ACR50 and the number of patients who discontinued due to adverse events. Our network meta-analysis was based on mixed-effects logistic regression, including both direct and indirect comparisons of the treatment effects, while preserving the randomised comparisons within each trial. PROSPERO identifier: CRD42012002800. RESULTS: The analysis comprises 28 trials (8602 patients), including all nine biological agents approved for RA. Eight trials included "DMARD-naïve", and 20 "DMARD-Inadequate responder" (DMARD-IR) patients. All agents except anakinra and infliximab were superior (p < 0.05) to placebo (i.e., no DMARD treatment) with regard to ACR50. Etanercept and rituximab were superior to anakinra (p = 0.018 and p = 0.049, respectively). Tocilizumab was superior to adalimumab (p = 0.0082), anakinra (p = 0.0083), certolizumab (p = 0.037), and golimumab (p = 0.049). No differences among etanercept, tocilizumab, and rituximab were found (p > 0.52). However, because rituximab was evaluated in just 40 patients, our confidence in the estimates is limited. When including only DMARD-IR trials, the same statistical pattern emerged; in addition etanercept and tocilizumab were superior to abatacept. At recommended doses, both etanercept and tocilizumab were superior to adalimumab and certolizumab. No statistically significant differences among biological agents were found with respect to discontinuation due to adverse events (p > 0.068). CONCLUSIONS: Evidence from randomised trials suggests that most biological agents are effective as monotherapy. Although our confidence in the estimates is limited, etanercept or tocilizumab may be the optimal choice for most patients who need treatment with biological monotherapy. However, given our limited confidence in the estimates including possibility of bias, it is appropriate to strongly weight patients׳ preferences and values in the final treatment choice.


Assuntos
Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Produtos Biológicos/uso terapêutico , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA