Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 115(2): 511-517, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35870521

RESUMO

BACKGROUND: Fast-track and enhanced recovery after cardiac surgical procedures have shown reductions in intensive care unit (ICU) and hospital lengths of stay, with unchanged outcomes. However, cost reduction by an ultra-fast-track protocol after minimally invasive cardiac operations, without compromising clinical benefits, has yet to be demonstrated. METHODS: A total of 215 consecutive patients underwent robotic-assisted coronary artery bypass grafting, with 156 preoperatively stratified into conventional ICU recovery vs 59 candidates for a defined ICU-bypass protocol involving recovery room and floor care. Of these, 40 candidates completed the protocol, and 19 had conversion-to-ICU recovery. Because of right-skewed distribution, inpatient cost was log-transformed, and linear regression models were constructed to estimate geometric mean ratios (GMRs) comparing inpatient cost for these groups (conventional ICU recovery, ICU-bypass, conversion-to-ICU recovery), adjusted for The Society of Thoracic Surgeons Predicted Risk of Mortality score. RESULTS: Compared with the conventional ICU group, the ICU-bypass group conferred a 15% reduction in total inpatient (GMR, 0.85; P = .0007) and a 14% reduction in total variable direct costs (GMR, 0.86; P = .003). Compared with the conventional ICU group, the ICU-bypass and conversion-to-ICU groups had similar net hospital stay reductions (1.6-1.7 days). Relative to the conventional ICU group, ICU and floor duration were shortened after conversion to ICU, with a trend to reduced costs. Cardiac arrest, 30-day mortality, and stroke were absent, and other key adverse events did not differ between groups. CONCLUSIONS: A selective, successful ultra-fast-track ICU-bypass protocol for robotic-assisted coronary artery bypass grafting reduces inpatient cost without affecting short-term outcomes. Conversion-to-ICU recovery also maintains outcomes and trends toward reduced costs.


Assuntos
Doença da Artéria Coronariana , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Ponte de Artéria Coronária/métodos , Unidades de Terapia Intensiva , Tempo de Internação
2.
Am J Emerg Med ; 52: 132-136, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34922232

RESUMO

BACKGROUND: Hands-on defibrillation (HOD) could theoretically improve the efficacy of cardiopulmonary resuscitation (CPR) though a few mechanisms. Polyethylene drapes could potentially facilitate safe HOD, but questions remain about the effects of CPR on polyethylene's conductance and the magnitude of current looping through rescuers' arms in contact with patients. METHODS: This study measured the leakage current through 2 mil (0.002 in.) polyethylene through two different current pathways before and after 30 min of continuous compressions on a CPR mannequin. The two pathways analyzed were the standardized IEC (International Electrotechnical Commission) leakage current analysis and a setup analyzing a current pathway looping through a rescuer's arms and returning to the patient. First, ten measurements involving the two pathways were obtained on a single polyethylene drape. 30 min of continuous compressions were applied to the drape on a CPR mannequin after which the ten measurements were repeated. RESULTS: Twenty patients undergoing elective cardioversion for atrial fibrillation (18/20) or atrial flutter (2/20) at Emory University Hospital underwent analysis all receiving 200 J shocks (age 38-101, 35% female). Through the IEC measurement method the peak leakage current mean was 0.70 +/- 0.02 mA before compressions and 0.59 +/- 0.19 mA after compressions. Only three of the ten measurements assessing current passing through a rescuer's arms had detectable current and each was of low magnitude. All measurements were well below the maximum IEC recommendations of 3.5 mA RMS and 5.0 mA peak. CONCLUSIONS: Polyethylene may facilitate safe HOD even after long durations of compressions. Current looping through a rescuer's arms is likely of insignificant magnitude.


Assuntos
Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica/métodos , Massagem Cardíaca/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Traumatismos por Eletricidade/prevenção & controle , Feminino , Humanos , Masculino , Manequins , Pessoa de Meia-Idade , Polietileno/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA