RESUMO
We introduce an analytical kernel, the "cusp" kernel, to model the effects of velocity-changing collisions on optically pumped atoms in low-pressure buffer gases. Like the widely used Keilson-Storer kernel [J. Keilson and J. E. Storer, Q. Appl. Math. 10, 243 (1952)], cusp kernels are characterized by a single parameter and preserve a Maxwellian velocity distribution. Cusp kernels and their superpositions are more useful than Keilson-Storer kernels, because they are more similar to real kernels inferred from measurements or theory and are easier to invert to find steady-state velocity distributions.
RESUMO
Precise measurements show that the microwave resonance frequencies of ground-state Rb or Cs atoms have a nonlinear dependence on the pressure of the buffer gases Ar and Kr. No nonlinearities were observed in the gases He or N(2). These observations strongly suggest that the nonlinearities are due to the van der Waals molecules that form in Ar and Kr, but not in He or N(2). The nonlinear part of the shifts is largest in the pressure range of a few tens of torr, similar to the operating pressures of gas-cell atomic clocks. The observed shifts are very well described by a simple function, parametrized by the effective three-body formation rate of molecules and by the effective product of the collisionally limited lifetime times the shift of the hyperfine coupling coefficient in the molecule.
RESUMO
We report NMR measurements of metallic (133)Cs in glass cells. The solid-liquid phase transition was studied by observing the NMR peaks arising from these two phases; surprisingly, many cells yielded two additional NMR peaks below the melting point. We attribute these signals to two distinct impurities which can dissolve in the liquid alkali metal and affect its chemical shift. Intentional contamination of cesium cells with O(2) confirms this hypothesis for one peak. The other contaminant remains unknown but can appear in evacuated cells. Similar effects have been seen in (87)Rb cells.
RESUMO
We report enhancement of the spin polarization of 133Cs nuclei in CsH salt by spin transfer from an optically pumped cesium vapor. The nuclear polarization was 4.0 times the equilibrium polarization at 9.4 T and 137 degrees C, with larger enhancements at lower fields. This work is the first demonstration of spin transfer from a polarized alkali vapor to the nuclei of a solid, opening up new possibilities for research in hyperpolarized materials.
RESUMO
A vapor of alkali-metal atoms in the external cavity of a semiconductor laser, pumped with a time-independent injection current, can cause the laser to self-modulate at the "field-independent 0-0 frequency" of the atoms. Push-pull optical pumping by the modulated light drives most of the atoms into a coherent superposition of the two atomic sublevels with an azimuthal quantum number m=0. The atoms modulate the optical loss of the cavity at the sharply defined 0-0 hyperfine frequency. As in a maser, the system is not driven by an external source of microwaves, but a very stable microwave signal can be recovered from the modulated light or from the modulated voltage drop across the laser diode. Potential applications for this new phenomenon include atomic clocks, the production of long-lived coherent atomic states, and the generation of coherent optical combs.
RESUMO
A new optical pumping method, "push-pull pumping," can produce very nearly pure, coherent superposition states between the initial and the final sublevels of the important field-independent 0-0 clock resonance of alkali-metal atoms. The key requirement for push-pull pumping is the use of D1 resonant light which alternates between left and right circular polarization at the Bohr frequency of the state. The new pumping method works for a wide range of conditions, including atomic beams with almost no collisions, and atoms in buffer gases with pressures of many atmospheres.
RESUMO
We present experimental and theoretical results showing that magnetic resonance transitions from the "end" sublevels of maximum or minimum spin in alkali-metal vapors are a promising alternative to the conventional 0-0 transition for small-size gas-cell atomic clocks. For these "end resonances," collisional spin-exchange broadening, which often dominates the linewidth of the 0-0 resonance, decreases with increasing spin polarization and vanishes for 100% polarization. The end resonances also have much stronger signals than the 0-0 resonance, and are readily detectable in cells with high buffer-gas pressure.
RESUMO
We report extensive new measurements of the longitudinal relaxation time T1 of 129Xe nuclear spins in solid xenon. For temperatures T<120 K and magnetic fields B>0.05 T, we found T1 on the order of hours, in good agreement with previous measurements and with the predicted phonon-scattering limit for the spin-rotation interaction. For T>120 K, our new data show that T1 can be much shorter than the phonon scattering limit. For B = 0.06 T, a field often used to accumulate hyperpolarized xenon, T1 is approximately 6 s near the Xe melting point T(m) = 161.4 K. From T = 50 K to T(m), the new data are in excellent agreement with the theoretical prediction that the relaxation is due to (i) modulation of the spin-rotation interaction by phonons, and (ii) modulation of the dipole-dipole interaction by vacancy diffusion.
RESUMO
We report the first studies of magnetic decoupling of the spin relaxation of alkali-metal atoms due to binary collisions with buffer gases. When binary collisions are the dominant relaxation mechanism, the relaxation and its magnetic decoupling are well described by the S-damping rate Gamma(SD) due to the spin-rotation interaction gammaN.S, the spin exchange rate Gamma(EX) for collisions between alkali atoms, and a new "Carver rate" Gamma(C), due to the pressure-shift interaction deltaAI.S, which can substantially broaden the magnetic decoupling curve while having no influence on the zero-field rates.
RESUMO
We present in situ measurements of temperatures inside multi-atmosphere spin-exchange optical pumping cells using Raman scattering from the N2 quenching gas. Under conditions usually prevailing in spin-exchange optical pumping experiments, we find that gas temperatures can be elevated hundreds of degrees above ambient, and that convection plays a very important role in the heat transport of the system.
RESUMO
Resonances in the magnetic decoupling curves for the spin relaxation of dense alkali-metal vapors prove that much of the relaxation is due to the spin-axis interaction in triplet dimers. Initial estimates of the spin-axis coupling coefficients for the dimers (likely accurate to a factor of 2) are |lambda|/h = 290 MHz for Rb; 2500 MHz for Cs.
Assuntos
Césio/química , Rubídio/química , Espectroscopia de Ressonância MagnéticaRESUMO
The magnetization in hyperpolarized gas (HP) MRI is generated by laser polarization that is independent of the magnet and imaging process. As a consequence, there is no equilibrium magnetization during the image acquisition. The competing processes of gas inflow and depolarization of the spins lead to large changes in signal as one samples k-space. A model is developed of dynamic changes in polarization of hyperpolarized 3He during infusion and in vivo imaging of the lung and verified experimentally in a live guinea pig. Projection encoding is used to measure the view-to-view variation with temporal resolution < 4 ms. Large excitation angles effectively sample the magnetization in the early stages of inflow, highlighting larger airways, while smaller excitation angles produce images of the more distal spaces. The work provides a basis for pulse sequences designed to effectively exploit HP MRI in the lung.
Assuntos
Hélio , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Animais , Cobaias , Isótopos , Masculino , RespiraçãoRESUMO
Using a new method of xenon laser-polarization that permits the generation of liter quantities of hyperpolarized 129Xe gas, the first 129Xe imaging results from the human chest and the first 129Xe spectroscopy results from the human chest and head have been obtained. With polarization levels of approximately 2%, cross-sectional images of the lung gas-spaces with a voxel volume of 0.9 cm3 (signal-to-noise ratio (SNR), 28) were acquired and three dissolved-phase resonances in spectra from the chest were detected. In spectra from the head, one prominent dissolved-phase resonance, presumably from brain parenchyma, was detected. With anticipated improvements in the 129Xe polarization system, pulse sequences, RF coils, and breathing maneuvers, these results suggest the possibility for 129Xe gas-phase imaging of the lungs with a resolution approaching that of current conventional thoracic proton imaging. Moreover, the results suggest the feasibility of dissolved-phase imaging of both the chest and brain with a resolution similar to that obtained with the gas-phase images.
Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Isótopos de Xenônio , Adulto , Encéfalo/anatomia & histologia , Feminino , Humanos , Pulmão/anatomia & histologia , MasculinoRESUMO
Two healthy volunteers who had inhaled approximately 0.75 L of laser-polarized helium-3 gas underwent magnetic resonance imaging at 1.5 T with fast gradient-echo pulse sequences and small flip angles ( < 10 degrees). Thick-section (20 mm) coronal images, time-course data (30 images collected every 1.8 seconds), and thin-section (6 mm) images were acquired. Subjects were able to breathe the gas (12% polarization) without difficulty. Thick-section images were of good quality and had a signal-to-noise ratio (S/N) of 32:1 near the surface coil and 16:1 farther away. The time images showed regional differences, which indicated potential value for quantitation. High-resolution images showed greater detail and a S/N of approximately 6:1.
Assuntos
Hélio , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Aumento da Imagem/métodos , Isótopos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-IdadeRESUMO
The authors imaged the lungs of live guinea pigs with hyperpolarized (HP) helium-3 as a magnetic resonance (MR) signal source. HP He-3 gas produced through spin exchange with rubidium metal vapor was delivered through an MR-compatible, small-animal ventilator. Two- and three-dimensional lung images acquired with ventilation-gated, radial k-space sampling showed complete ventilation of both lungs. All images were of high quality, demonstrating that HP He-3 allows high-signal-intensity MR imaging in living systems.
Assuntos
Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Animais , Cobaias , Hélio , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , RadioisótoposRESUMO
Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system offers great promise for eventual in vivo imaging experiments. Fast 2D and 3D GRASS sequences with very small flip angles were employed to conserve the norenewable longitudinal magnetization. We discuss various unique features associated with performing MRI with hyperpolarized gases, such as the selection of the noble gas species, polarization technique, and constraints on the MR pulse sequence.
Assuntos
Hélio , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética , Animais , Cobaias , Hélio/química , Hélio/metabolismo , Hélio/efeitos da radiação , Aumento da Imagem/métodos , Lasers , Pulmão/metabolismo , Espectroscopia de Ressonância Magnética , Rubídio/química , Rubídio/efeitos da radiação , Fatores de TempoRESUMO
As currently implemented, magnetic resonance imaging (MRI) relies on the protons of water molecules in tissue to provide the NMR signal. Protons are, however, notoriously difficult to image in some biological environments of interest, notably the lungs and lipid bilayer membranes such as those in the brain. Here we show that 129Xe gas can be used for high-resolution MRI when the nuclear-spin polarization of the atoms is increased by laser optical pumping and spin exchange. This process produces hyperpolarized 129Xe, in which the magnetization is enhanced by a factor of about 10(5). By introducing hyperpolarized 129Xe into mouse lungs we have obtained images of the lung gas space with a speed and a resolution better than those available from proton MRI or emission tomography. As xenon (a safe general anaesthetic) is rapidly and safely transferred from the lungs to blood and thence to other tissues, where it is concentrated in lipid and protein components, images of the circulatory system, the brain and other vital organs can also be obtained. Because the magnetic behaviour of 129Xe is very sensitive to its environment, and is different from that of 1H2O, MRI using hyperpolarized 129Xe should involve distinct and sensitive mechanisms for tissue contrast.