Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Proc Natl Acad Sci U S A ; 118(10)2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33649234

RESUMO

Cold stress is an adverse environmental condition that affects plant growth, development, and crop productivity. Under cold stress conditions, the expression of numerous genes that function in the stress response and tolerance is induced in various plant species, and the dehydration-responsive element (DRE) binding protein 1/C-repeat binding factor (DREB1/CBF) transcription factors function as master switches for cold-inducible gene expression. Cold stress strongly induces these DREB1 genes. Therefore, it is important to elucidate the mechanisms of DREB1 expression in response to cold stress to clarify the perception and response of cold stress in plants. Previous studies indicated that the central oscillator components of the circadian clock, CIRCADIAN CLOCK-ASSOCIATED 1 (CCA1) and LATE ELONGATED HYPOCOTYL (LHY), are involved in cold-inducible DREB1 expression, but the underlying mechanisms are not clear. We revealed that the clock-related MYB proteins REVEILLE4/LHY-CCA1-Like1 (RVE4/LCL1) and RVE8/LCL5 are quickly and reversibly transferred from the cytoplasm to the nucleus under cold stress conditions and function as direct transcriptional activators of DREB1 expression. We found that CCA1 and LHY suppressed the expression of DREB1s under unstressed conditions and were rapidly degraded specifically in response to cold stress, which suggests that they act as transcriptional repressors and indirectly regulate the cold-inducible expression of DREB1s We concluded that posttranslational regulation of multiple clock-related transcription factors triggers cold-inducible gene expression. Our findings clarify the complex relationship between the plant circadian clock and the regulatory mechanisms of cold-inducible gene expression.


Assuntos
Proteínas de Arabidopsis/biossíntese , Arabidopsis/metabolismo , Resposta ao Choque Frio , Regulação da Expressão Gênica de Plantas , Fatores de Transcrição/biossíntese , Arabidopsis/genética , Proteínas de Arabidopsis/genética , Fatores de Transcrição/genética
2.
Metallomics ; 9(8): 1001-1013, 2017 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-28758652

RESUMO

In 2004, the term "metallomics" was coined to describe integrated biometal science (H. Haraguchi, Metallomics as Integrated Biometal Science, J. Anal. At. Spectrom., 2004, 19, 5-14). Around 10 years have passed since then, and the history of metallomics over the last decade is reviewed here, discussing the development of metallomics before and after the proposal. Furthermore, the future outlook of metallomics research will be considered, in terms of topics such as the organization of platforms for metallomics research related to trace metal sciences, a simplified model of the biological system and omics-sciences, research subjects in metallomics, recent trends of metallomics research, and the challenge of single biological cell analysis.


Assuntos
Metaloproteínas/metabolismo , Metais/análise , Metais/história , Micronutrientes/metabolismo , Biologia Computacional , História do Século XXI , Humanos , Metais/metabolismo
3.
Anal Sci ; 28(12): 1121-4, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23232229

RESUMO

The distributions of eleven elements in a peanut seed were obtained by elemental imaging with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The distribution of Mo was significantly different to those of other elements, such as K, P, and Mg. It was also confirmed that this typical enrichment of Mo was not dependent on the region where the peanut seed was planted. The enrichment of Mo was observed in the radicle of peanut seed, and was further confirmed by the isotopic ratio of Mo.


Assuntos
Arachis/química , Magnésio/química , Molibdênio/química , Fósforo/química , Raízes de Plantas/química , Potássio/química , Sementes/química , Lasers , Espectrometria de Massas
4.
Anal Chim Acta ; 713: 23-9, 2012 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-22200303

RESUMO

Accurate quantification of DNA is highly important in various fields. Determination of phosphorus by ICP-MS is one of the most effective methods for accurate quantification of DNA due to the fixed stoichiometry of phosphate to this molecule. In this paper, a smart and reliable method for accurate quantification of DNA fragments and oligodeoxythymidilic acids by hyphenated HPLC/ICP-MS equipped with a highly efficient interface device is presented. The interface was constructed of a home-made capillary-attached micronebulizer and temperature-controllable cyclonic spray chamber (IsoMist). As a separation column for DNA samples, home-made methacrylate-based weak anion-exchange monolith was employed. Some parameters, which include composition of mobile phase, gradient program, inner and outer diameters of capillary, temperature of spray chamber etc., were optimized to find the best performance for separation and accurate quantification of DNA samples. The proposed system could achieve many advantages, such as total consumption for small amount sample analysis, salt-tolerance for hyphenated analysis, high accuracy and precision for quantitative analysis. Using this proposed system, the samples of 20 bp DNA ladder (20, 40, 60, 80, 100, 120, 140, 160, 180, 200, 300, 400, 500 base pairs) and oligodeoxythymidilic acids (dT(12-18)) were rapidly separated and accurately quantified.


Assuntos
Cromatografia Líquida de Alta Pressão , DNA/análise , Espectrometria de Massas , Tolerância ao Sal , Cromatografia por Troca Iônica , DNA/isolamento & purificação , Oligodesoxirribonucleotídeos/análise , Oligodesoxirribonucleotídeos/isolamento & purificação , Fósforo/análise
5.
Anal Chem ; 83(21): 8252-8, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21958307

RESUMO

Adipose tissue-derived stem cells (ASCs) have shown promise in cell therapy because of their ability to self-renew damaged or diseased organs and easy harvest. To ensure the distribution and quantification of the ASCs injected from tail vein, several whole-body imaging techniques including fluorescence optical imaging with quantum dots (QDs) have been employed, but they may suffer from insufficient sensitivity and accuracy. Here, we report quantitative distribution of ASCs in various organs (heart, lung, liver, spleen, and kidney) of mice, which were intravenously injected with QDs-labeled ASCs (QDs-ASCs), through the detection of QDs-derived metallic components by inductively coupled plasma mass spectrometry (ICPMS). For accurate and precise determination, each organ was harvested and completely digested with a mixture of HNO(3) and H(2)O(2) in a microwave oven prior to ICPMS measurement, which was equipped with a microflow injection system and a laboratory-made capillary-attached micronebulizer. After optimization, 16 elements including major components (Cd, Se, and Te) of QDs and essential elements (Na, K, Mg, Ca, P, S, Mn, Fe, Co, Cu, Zn, Se, Sr, and Mo) were successfully determined in the organs. As compared to untreated mice, QDs-ASCs-treated mice showed significantly higher levels of Cd and Te in all organs, and as expected, the molar ratio of Cd to Te in each organ was in good agreement with the molar composition ratio in the QDs. This result indicates that the increment of Cd (or Te) can be used as a tracer for calculating the distribution of ASCs in mice organs. As a result of the calculation, 36.8%, 19.1%, 0.59%, 0.49%, and 0.25% of the total ASCs injected were estimated to be distributed in the liver, lung, heart, spleen, and kidney, respectively.


Assuntos
Tecido Adiposo/citologia , Espectrometria de Massas , Metais/análise , Pontos Quânticos , Células-Tronco/citologia , Animais , Bovinos , Feminino , Injeções Intravenosas , Camundongos , Camundongos Endogâmicos C57BL , Imagem Molecular , Distribuição Tecidual
6.
Metallomics ; 3(7): 648-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21706109
7.
Talanta ; 81(4-5): 1438-45, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20441920

RESUMO

A syringe-based sample pretreatment tool, named herein "tip-in chelating monolith", has been developed for simple and facile solid phase microextraction (SPME) of trace elements in natural waters. The tip-in chelating monolith was directly prepared within the confines of a commercially available syringe filter tip by a two-step process: (1) in situ polymerization of a monomer solution consisting of 22.5% glycidyl methacrylate (GMA), 7.5% ethylene glycol dimethacrylate (EDMA), 35% 1-propanol, 28% 1,4-butanediol, and 7% water and (2) its subsequent modification with 1molL(-1) of iminodiacetate solution (adjusted to pH 10) via ring-opening reaction of epoxide. The adsorption properties of the tip-in chelating monolith thus obtained were evaluated through an adsorption/desorption experiment, where the effects of sample solution pH and eluent on the SPME of trace metals and metalloids were systematically examined. Consequently, when sample solution pH was adjusted to 5.0 and 0.9mL of 2molL(-1) nitric acid was used as an eluent, good recoveries of more than 80% were obtained for 27 elements in a single-step extraction. The proposed SPME method was validated through the analysis of two river water certified reference materials (CRMs: JSAC 0301-1 and NMIJ 7201-a). After 50-fold preconcentration (from 50mL of the original river water sample to 1.0mL of final analysis solution), 22 trace elements including Ti, Fe, Co, Ni, Cu, Ga, Cd, Sn and REEs were quantitatively determined by inductively coupled plasma mass spectrometry (ICP-MS). The analytical detection limits were in the range from 0.000003microgL(-1) for Ho to 0.18microgL(-1) for Fe. Good agreement of the observed values with the certified or reference values indicates that the proposed SPME using the tip-in chelating monolith is practically applicable.


Assuntos
Adsorção , Quelantes/química , Microextração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , 1-Propanol/análise , Butileno Glicóis/análise , Quelantes/farmacologia , Compostos de Epóxi/análise , Concentração de Íons de Hidrogênio , Iminoácidos/química , Ligantes , Metacrilatos/análise , Rios , Solventes/química , Oligoelementos/análise , Água/análise
8.
Talanta ; 78(3): 891-5, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19269446

RESUMO

A syringe-driven chelating column (SDCC) was applied to develop an on-line preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) method for preconcentration and determination of rare earth elements (REEs) in seawater samples. The present on-line preconcentration system consists of only one pump, two valves, an SDCC, an ICP-MS, several connectors, and Teflon tubes. Optimizations of adsorption pH condition, sample loading flow rate, and integration range were carried out to achieve optimum measurement conditions for REEs in seawater sample. Six minutes was enough for a preconcentration and measurement cycle using 10 mL of seawater sample, where the detection limits for different REEs were in the range of 0.005 pg mL(-1) to 0.09 pg mL(-1). Analytical results of REEs in a seawater certified reference material (CRM), NASS-5, confirmed the usefulness of the present method. Furthermore, concentrations of REEs in Nikkawa Beach coastal seawater were determined and discussed with shale normalized REE distribution pattern.


Assuntos
Metais Terras Raras/análise , Água do Mar/análise , Quelantes , Cromatografia de Afinidade , Concentração de Íons de Hidrogênio , Espectrometria de Massas/métodos
9.
Anal Sci ; 25(1): 137-40, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19139589

RESUMO

Thirty elements in garlic sample were determined by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES) after microwave digestion. The concentrations of K, Ca,Na, Sr, and Hg in the present garlic sample were higher than those in rice and wheat, but the concentration of Se in the garlic sample was relatively lower. The extractability of the elements in the garlic sample was also examined; the results showed that most of the elements could be easily extracted by pure water and/or a 0.1 M HNO(3) solution, except for Hg. Furthermore, the size-fractional distribution of the elements in garlic was investigated by pure water extraction and centrifugal ultrafiltration.


Assuntos
Alho/química , Metais/análise , Cálcio , Centrifugação , Mercúrio , Oryza/química , Potássio , Selênio , Sódio , Soluções , Espectrofotometria Atômica/métodos , Estrôncio , Espectrometria de Massas em Tandem/métodos , Triticum/química
10.
Anal Sci ; 24(11): 1513-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18997385

RESUMO

A tandem preconcentration method integrating chelating resin adsorption and La coprecipitation was applied to an analysis of Lake Baikal water by high-resolution ICP-MS. As a result, 56 elements were determined in Lake Baikal water: Ca, Na, Mg, K, Si, Sr, B, Li, Ba, P, Fe, Al, Mo, Zn, Mn, Rb, U, As, V, Cu, Pb, W, Y, Cs, Se, Cr, Ni, Ti, Sb, Zr, Sn, Co, Cd, Rh, Te, Hf, Nb, Ru, Ga, Sc, Th, Bi, and all-rare earth elements (all-REEs), except for Pm. The concentrations of these elements covered a range of nine orders of magnitude, from approximately 17 microg mL(-1) of Ca to less than 50 fg mL(-1) of Tm. The elemental concentrations in Lake Baikal water were compared with reference data.

11.
Anal Sci ; 24(9): 1189-92, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18781034

RESUMO

A lanthanum (La) coprecipitation method with low sample consumption was explored for the preconcentration of oxo-anion forming elements prior to a measurement by inductively coupled plasma mass spectrometry (ICP-MS). The preconcentration procedure was composed of two main steps: (1) the formation of a coprecipitate with the lowest possible La and (2) the redissolution of target analytes with minimal use of nitric acid, and the elimination of high concentration La from the analysis sample. Each step was performed in a 25 mL-volume syringe to reduce the sample consumption and to avoid contamination from the experimental environment. Various parameters, such as the concentration and volume of La added into the sample solution, the precipitation pH, the aging time, and the volume of HNO(3) were optimized to obtain good recoveries and high detection sensitivities for V, As, Sb, and W, which could be hardly recovered by solid-phase extraction using a chelating resin. The obtained method was evaluated through the analysis of seawater reference materials (CASS-4 and NASS-5). The recoveries exceeded 80%, and the observed values were in good agreement with the certified values.

12.
Anal Sci ; 23(12): 1359-66, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18071219

RESUMO

PM10 samples were collected at an urban site of Nagoya City during September, 2003, to August, 2004, and annual variations of the concentrations of the elements in PM10 samples were examined by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The annual concentration variations of ca. 30 elements in ambient air were in the range from sub-ng m(-3) to several microg m(-3). From an evaluation by the enrichment factors of the elements, elements such as Al, Ca, Fe, Mg, Ti, Mn, Ba, Sr, Ce, La, Nd, Co, Cs, and Pr, in PM10 samples were found to have originated mostly from natural sources, while the elements such as S, Zn, Pb, Cu, Ni, Sb, Sn, Cd, Bi, W, Tl, and In originated from anthropogenic emission sources. Furthermore, in seasonal variations of the elemental concentrations of PM10 samples in ambient air, the elements originated mostly from natural sources provided significantly high concentrations in spring during the "Kosa" period (the dust season from March to May). On the other hand, the elements mainly from anthropogenic emission sources provided relatively higher concentrations in autumn and winter, which may be explained by the fact that the urban atmospheric structure is stabilized by the temperature-inversion layer formed over the city in those seasons. In addition, all of the elements provided significantly low concentrations in the summer, due to the dilution effect of the oceanic winds as well as due to the convection of air mass up to the high levels.

13.
Anal Sci ; 23(2): 207-13, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17297234

RESUMO

The multielement determination of PM(10) (airborne particulate matter smaller than 10 microm) samples, which was collected by a high volume air sampler at the urban site of Nagoya City, was carried out by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The present analytical method was validated by analyzing urban particulate matter standard reference material of NIST SRM 1648. The analytical data for ca. 30 elements in PM(10) samples collected during a period from 8 September to 9 October, 2003, were obtained in the concentration range from sub-microg g(-1) to several-10 mg g(-1), but the data for 18 elements among ca. 30 elements were available for the characterization of PM(10) samples in ambient air, because of problems caused by the filter blanks. Then, the trends concerning the distributions of diverse elements in PM(10) samples were analyzed based on the enrichment factors and size distribution factors. The lithophile and siderophile elements were distributed more than 50% in coarse particle fraction (>2.1 microm), which was derived mainly from natural sources, such as soils and crustal minerals. On the other hand, chalcophile elements were distributed more than 50% in fine particle fraction (<2.1 microm), which was derived mostly from anthropogenic emission sources. The large enrichment of chalcophile elements in PM(10) samples as well as their mining influence factors (MIFs) suggested their wide use in industrial productions.

14.
Talanta ; 72(2): 600-6, 2007 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-19071661

RESUMO

The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400mesh), with which trace metals in 50mL of original seawater sample were concentrated into 0.50mL of 2M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1M ammonium acetate for elimination of matrix elements, and the amount of 2M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.

15.
Talanta ; 72(5): 1791-9, 2007 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-19071834

RESUMO

The determination of 52 impurity elements in niobium materials (niobium metal, niobium oxide (V), and niobium pentaethoxide) was performed by inductively coupled plasma mass spectrometry (ICP-MS) with on-line anion exchange matrix separation as well as direct nebulization. Niobium material samples were decomposed with a mixture of hydrofluoric acid and nitric acid to prepare 10% niobium solutions. In the on-line anion exchange matrix separation/ICP-MS, the niobium and hydrofluoric acid concentrations in sample solution were adjusted to 5% and ca. 8M, respectively. The solution was then injected into the carrier stream from the sample loop of injection valve to pass through an anion exchange resin column. In the anion exchange separation, niobium in the fluoro-complex form was adsorbed on the resin, while impurity elements were eluted. The eluted elements were introduced into ICP-MS for the determination of 25 impurity elements. On the other hand, 27 impurity elements could not be separated well from niobium matrix under the above anion exchange conditions, and then the sample solution with the niobium concentration of max. 0.2% containing internal standard elements was injected from the sample loop of injection valve directly to introduce into ICP-MS. As a result, 52 impurity elements in three kinds of niobium materials could be determined at the ng g(-1) level.

16.
Anal Bioanal Chem ; 386(3): 566-71, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16685518

RESUMO

Hexyl methacrylate (HMA)-based monolithic semi-micro columns were prepared by in situ polymerization within the confines of 1.02-mm-i.d. silicosteel tubing for reversed-phase and/or precipitation-redissolution liquid chromatography. Practically useful monolithic columns with adequate separation efficiency, high permeability, and good mechanical strength were successfully obtained using a polymerization mixture comprising 24% hexyl methacrylate (HMA), 6% ethylene dimethacrylate (EDMA), 44.5% 1-propanol, and 25.5% 1,4-butanediol. The column performance was evaluated through the separations of a series of alkylbenzenes. At a normal flow rate of 50 microL min(-1), the produced HMA-based monolithic columns typically exhibited 3,000 theoretical plates for a 20-cm-long column, and the pressure drop was generally less than 1 MPa per 20 cm. The monolithic columns were resistant to at least 15 MPa, and could be properly operated at 15-20 times higher flow rate than normal, reducing the separation time to 1/15-1/20. The HMA-based monolithic columns were applied to rapid and efficient separations of proteins such as ribonuclease A, cytochrome c, transferrin, and ovalbumin in the precipitation-redissolution mode. Using a CH(3)CN gradient elution at a flow rate of 1,000 microL min(-1), four proteins were baseline separated within 20 s.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Metacrilatos/química , Proteínas/análise , Metacrilatos/síntese química
17.
J Chromatogr A ; 1106(1-2): 106-11, 2006 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-16443455

RESUMO

Low flow-resistant alkyl methacrylate-based monolithic stationary phases of different hydrophobicity were constructed for reversed-phase capillary liquid chromatography by thermally initiated radical polymerization of respective methacrylate ester monomer with different alkyl chain (C2, C4, C6, C12, C18) and ethylene glycol dimethacrylate (EDMA) in a 250 microm i.d. fused silica capillary. The hydrophobicity was basically controlled by changing the length and/or the density of the alkyl-chain, while the composition and the ratio of porogenic solvent were adjusted to obtain highly permeable rigid monoliths with adequate column efficiency. Among the prepared monolithic stationary phases, C18-methacrylate monoliths polymerized from a binary porogenic solvent of isoamyl alcohol and 1,4-buthandiol exhibited the most promising performance in terms of hydraulic resistance and column efficiency. The pressure drops of 20-cm long monolithic columns were below approximately 0.4 MPa at a normal linear velocity of 1mm/s (a flow rate of 3 microL/min), and the numbers of theoretical plates for alkylbenzenes mostly exceeded 3000 plates/20 cm. The produced monolithic columns had good mechanical strength for high pressure and temperature, and could be properly operated even at a temperature of 80 degrees C and at a pressure of at least 33 MPa. At 80 degrees C, the theoretical plate numbers reached 6000 plates/20 cm because of the enhanced mass transfer. Due to the novel hydraulic resistance and mechanical strength, the separation time could be reduced 120-fold simply by raising the flow rate and column temperature.


Assuntos
Benzeno/isolamento & purificação , Cromatografia Líquida/instrumentação , Temperatura Alta , Metacrilatos/química
18.
Anal Sci ; 21(8): 913-6, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16122160

RESUMO

An octadecylsilica (ODS) column modified with zwitterionic/nonionic mixed surfactants was evaluated for the direct injection determination of inorganic anions in biological fluids by ion chromatography. A zwitterionic surfactant (sulfobetaine-type) and a nonionic surfactant (polyoxyethylene-type) were used for a stationary-phase modification. When aqueous electrolyte solutions with concentrations of sub-mM to several mM were used as a mobile phase, the zwitterionic surfactant coated on the ODS surface exhibited unique separation selectivity for ionic species, while the nonionic surfactant coated on the ODS might have formed a hydrophilic network over the ODS surface and restricted matrix proteins from adsorbing on the stationary phase. Consequently, the mixed surfactant-modified column system allowed an efficient ion chromatographic separation of inorganic anions as well as a size-exclusive removal of column-fouling proteins. This separation system was applied to the direct injection determination of UV-absorbing anions in human saliva. The detection limits for nitrite, nitrate, iodide and thiocyanate were 3.1, 2.7, 4.5 and 25 microM, respectively, with UV detection at 210 nm (injection volume; 20 microl), and their relative standard deviations for 5 replicate measurements of saliva samples spiked with 100 microM each of those anions were 1.4, 0.9, 2.2 and 5.5%, respectively.


Assuntos
Ânions/análise , Cromatografia/instrumentação , Dióxido de Silício/química , Tensoativos/química , Ânions/química , Cromatografia/métodos
19.
Anal Sci ; 21(3): 199-203, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15790098

RESUMO

The determination of 34 trace metals in a river water certified reference material (CRM), i.e. JSAC 0301-1, which was issued by the Japan Society for Analytical Chemistry in January 2004, was performed by ICP-MS with a high efficiency nebulizer after preconcentration with a laboratory-made chelating resin-packed minicolumn, with which trace metals were concentrated 100-fold from 50 mL of a river water sample to 0.5 mL of the final analysis solution. Trace metals in JSAC 0301-1 were observed in the concentration range from 19 microg L(-1) of Al to 0.000053 microg L(-1) of Bi. It was found that most of the concentrations of trace metals, including rare earth elements (REEs), in JSAC 0301-1 were lower than those in JAC 0031, which was also a previously issued CRM prepared with water from the same river as that of JSAC 0301-1. The low concentrations of trace metals in JSAC 0301-1 might be attributed to the fact that there was a heavy rain before collecting the original water sample to prepare the present CRM. Furthermore, the REE distribution patterns of JSAC 0301-1, JAC 0031 and the average values of river water samples in Japan were parallel to each other. These results indicate that the distributions of REEs in JSAC 0301-1 and JAC 0031 were the typical ones of river water samples in Japan.

20.
Talanta ; 68(2): 465-9, 2005 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970345

RESUMO

Speciation of mercury in salmon egg cell cytoplasm was investigated by surfactant-mediated high-performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS), where an ODS (octadecylsilica) column coated with a bile acid derivative, CHAPS (3-[(3-cholamidopropyl)-dimethylammonio]-1-propane sulfonate), was used for species separation. Prior to the speciation analysis, total Hg in the cell cytoplasm was determined by ICP-MS at m/z 202 in a flow injection mode. For the precise measurement, salmon egg cell cytoplasm was diluted five-fold with 0.1M Tris (Tris(hydroxymethyl)aminomethane)-HNO(3) buffer solution, and the standard addition method was employed. Thus, the total concentration of Hg in cell cytoplasm was estimated to be 12.4ngg(-1) on the wet weight basis. Next, the cell cytoplasm diluted five-fold with 0.1M Tris-HNO(3) buffer solution was analyzed by surfactant-mediated HPLC with the dual detection system of a UV absorption detector and an ICP-MS instrument. Two peaks corresponding to some proteins and small molecules were mainly observed in those chromatograms. When salmon egg cell cytoplasm was diluted five-fold with 0.01M Tris buffer solution or pure water, some precipitates appeared probably because of precipitation of hydrophobic proteins in cytoplasm. After the precipitates were eliminated with a membrane filter, the filtrate was subjected to the analysis by surfactant-mediated HPLC/UV/ICP-MS. As a result, the peaks for small molecular species of Hg were clearly observed at the retention time near 4.0min (corresponding to low-molecular weight zone) in the chromatograms with UV absorption detection as well as with Hg- and S-specific ICP-MS detections. The small molecule bound with Hg was identified as cysteine through the cysteine-spiked experiment. In addition, the protein fraction on the chromatogram obtained by using the CHAPS-coated ODS column was further analyzed by SEC (size exclusion chromatography). Consequently, several protein peaks with molecular weight of 300, 50 and 12kDa were observed in all the detections of UV absorption, Hg and Se, although two peaks among them were coincident in the case of S. These results indicate that Hg in salmon egg cell cytoplasm binds with proteins containing selenocysteine and/or cysteine residues in proteins.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA