Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Diagnostics (Basel) ; 14(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38535071

RESUMO

This study aimed to develop and validate a simple scoring system to determine the high-risk group for pancreatic cancer (PC) in the asymptomatic general population. The scoring system was developed using data from PC cases and randomly selected non-PC cases undergoing annual medical checkups between 2008 and 2013. The performance of this score was validated for participants with medical checkups between 2014 and 2016. In the development set, 45 PC cases were diagnosed and 450 non-PC cases were identified. Multivariate analysis showed three changes in clinical data from 1 year before diagnosis as independent risk factors: ΔHbA1c ≥ 0.3%, ΔBMI ≤ -0.5, and ΔLDL ≤ -20 mg/dL. A simple scoring system, incorporating variables and abdominal ultrasound findings, was developed. In the validation set, 36 PC cases were diagnosed over a 3-year period from 32,877 participants. The AUROC curve of the scoring system was 0.925 (95%CI 0.877-0.973). The positive score of early-stage PC cases, including Stage 0 and I cases, was significantly higher than that of non-PC cases (80% vs. 6%, p = 0.001). The simple scoring system effectively narrows down high-risk PC cases in the general population and provides a reasonable approach for early detection of PC.

2.
Dig Dis Sci ; 69(3): 969-977, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38300418

RESUMO

OBJECTIVES: In patients with unresectable malignant hilar biliary obstruction (UMHBO), drainage of ≥ 50% liver volume correlates with better clinical outcomes. Accurately measuring the liver volume to be drained by biliary stents is required. We aimed to develop a novel method for calculating the drained liver volume (DLV) using a 3D volume analyzer (3D volumetry), and assess the usefulness for drainage in patients with UMHBO. METHODS: Three-dimensional volumetry comprises the following steps: (1) manual tracing of bile duct using 3D imaging system; (2) 3D reconstruction of bile duct and liver parenchyma; and (3) calculating DLV according to the 3D distribution of bile ducts. Using 3D volumetry, we reviewed data of patients who underwent biliary drainage for UMHBO, calculated the DLV, and determined the association between DLV and biliary drainage outcome. RESULTS: There were 104 eligible cases. The mean DLV was 708 ± 393 ml (53% ± 21%). and 65 patients (63%) underwent drainage of ≥50% liver volume. The clinical success rate was significantly higher in patients with DLV ≥ 50% than in patients with DLV < 50% (89% vs. 28%, P < 0.001). The median time to recurrence of biliary obstruction (TRBO) and survival time were significantly longer in patients with DLV ≥ 50% than in patients with DLV < 50% (TRBO, 292 vs. 119 days, P = 0.03; survival, 285 vs. 65days, P = 0.004, log-rank test, respectively). CONCLUSIONS: Three-dimensional volumetry, a novel method to calculate DLV accurately according to bile duct distribution was useful for drainage in UMHBO patients.


Assuntos
Neoplasias dos Ductos Biliares , Colestase , Humanos , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Ductos Biliares/patologia , Stents , Drenagem/métodos , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38421093

RESUMO

BACKGROUND AND AIM: The 10-mm self-expandable metal stent (SEMS) is the standard for endoscopic transpapillary biliary drainage before pancreatic cancer surgery. However, the efficacy of stents thinner than 10 mm has not been adequately validated. Therefore, we aimed to evaluate the safety of a 6-mm fully covered SEMS (FCSEMS) for distal malignant biliary obstruction (DMBO) during preoperative chemotherapy for pancreatic cancer. METHODS: This was a single-arm, multicenter, prospective phase II study of endoscopic transpapillary initial biliary drainage for DMBO before pancreatic cancer surgery. The primary endpoint was stent-related adverse events, and the key secondary endpoint was the non-recurrent biliary obstruction (non-RBO) rate during the observation period for both resectable (R) and borderline resectable (BR) pancreatic cancers. RESULTS: The study enrolled 33 patients, among whom 32 received the study treatment. There were 23 and 9 cases of R and BR pancreatic cancers, respectively. The technical and clinical success rates were 97.0% and 90.1%, respectively. The stent-related adverse event rate was 3.1% (n = 1, acute pancreatitis) (95% confidential interval, 0.00-16.2), which met the criteria to be considered safe. The overall non-RBO rate during the observation period (median 96 days) was 78.1% (82.6% and 66.7% for R and BR pancreatic cancer cases, respectively). CONCLUSIONS: The 6-mm FCSEMS is an extremely safe metallic stent with a low stent-related adverse event rate of 3.1% for preoperative biliary drainage in pancreatic cancer. It is considered the optimal stent for preoperative biliary drainage in terms of the non-RBO rate. UMIN Clinical Trial Registry (UMIN-CTR 000041704).

4.
Endosc Ultrasound ; 12(5): 409-416, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37969165

RESUMO

Background and Objectives: During EUS-guided choledochoduodenostomy (EUS-CDS), fistula dilation before stent insertion is associated with adverse events (AEs), such as bile leakage and peritonitis. We hypothesized that EUS-CDS without fistula dilation using a novel self-expandable metal stent (SEMS) with a thin delivery system could overcome this problem, and we conducted this study to evaluate its feasibility and safety. Methods: This was an open-label, single-arm, phase II study at a single institution. We planned EUS-CDS without fistula dilation using a fully covered SEMS with a 5.9-Fr delivery system for unresectable malignant distal biliary obstruction. The primary outcome was overall technical success. Secondary outcomes were technical success without fistula dilation, procedure time, functional success, time to recurrent biliary obstruction, and AEs. The planned sample size was 25 patients. Results: In total, 24 patients were included in this study. In 21 patients, EUS-CDS was performed as primary drainage. The overall technical success rate was 100% (24 of 24 patients). The technical success rate without fistula dilation was 96% (23 of 24). The median procedure time was 16 min (range, 10-66 min). The functional success rate was 96% (23 of 24). The median time to recurrent biliary obstruction was 148 days (95% confidence interval, 29-266 days). There were no procedure-related AEs. Furthermore, computed tomography immediately after the procedure showed no leakage of contrast medium into the abdominal cavity in any patient. Conclusions: EUS-guided choledochoduodenostomy without fistula dilation using a fully covered SEMS with a 5.9-Fr delivery system is feasible with a high probability and can be achieved quickly while effectively preventing bile leakage and peritonitis.

8.
Endosc Int Open ; 11(1): E97-E104, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36712906

RESUMO

Background and study aims Recently, the utility of endoscopic ultrasound-guided intervention without fistula dilation (EUS-IV WoD) has been reported to prevent adverse events. We clinically evaluated cases in which EUS-IV WoD was attempted using a novel self-expandable metallic stent (SEMS); this is a fully covered, laser-cut SEMS that has a tapered and stiff tip specifically designed for a 0.025-inch guidewire and a relatively thin, 7F delivery system. Patients and methods We retrospectively evaluated cases wherein EUS-IV WoD was attempted using the novel SEMS between March and December 2021. Results Treatment of 11 patients by EUS-IV WoD with the novel SEMS was attempted. The technical success rate for EUS-IV was 100 % and the clinical success rate was 100 %; the success rate for EUS-IV WoD was 72.8 %. Of these, the procedural success rate for EUS-IV WoD was 100 % in EUS-biliary drainage (BD) and 57.1 % in non-EUS-BD. Early adverse events were observed in 27.3 % of patients (3/11): mild abdominal pain in two patients and moderate bleeding in one patient. The abdominal pain cases were both cases of EUS-IV WoD failure and required fistula dilation. Conclusions The novel stent may be useful for EUS-IV WoD, especially in EUS-BD.

9.
DEN Open ; 3(1): e169, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36247313

RESUMO

Background: The present study aimed to examine the correlation between preoperative carcinoembryonic antigen levels in pancreatic juice (PJ-CEA) and the histological subtype of intraductal papillary mucinous neoplasm (IPMN). Methods: We enrolled IPMN patients who underwent endoscopic retrograde pancreatography between March 2002 and March 2018. Clinical factors associated with IPMN histological subtypes of 67 patients who underwent surgery were analyzed. Furthermore, the relationship between CEA immunohistochemistry findings and histological subtypes was investigated. Results: Median PJ-CEA were 15 ng/ml in the gastric type, 150 ng/ml in the intestinal type, and 175 ng/ml in the pancreatobiliary type. Both intestinal and pancreatobiliary types had significantly higher PJ-CEA than the gastric type (p = 0.001). In the analysis of histological subtype predictors, high PJ-CEA (≥63 ng/ml) only showed a significant difference in multivariate analyses (95% confidence interval 4.8-70.2; p < 0.001). Immunohistochemistry findings revealed significantly higher CEA expression in the non-gastric type than in the gastric type (p < 0.001). The non-gastric type showed a significantly worse prognosis than the gastric type (p = 0.017). Conclusion: PJ-CEA was an independent predictor of IPMN histological subtypes in a preoperative setting. High PJ-CEA predict the non-gastric type, while low PJ-CEA predict the gastric type.

11.
Dig Endosc ; 35(1): 124-133, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35993898

RESUMO

OBJECTIVES: Comprehensive genomic profiling (CGP) has been approved in Japan since June 2019, enabling mutation-specific therapy. Although tissue sampling via endoscopic ultrasound-guided tissue acquisition (EUS-TA) is standard in pancreatic cancer, reports on obtaining appropriate samples for CGP, especially for the OncoGuide NCC Oncopanel System (NOP) and FoundationOne CDx (FOne), are lacking. Therefore, we investigated the success rate and factors related to appropriate EUS-TA sampling for CGP analysis suitability in unresectable pancreatic ductal adenocarcinoma (UR-PDAC). METHODS: Participants comprised 150 UR-PDAC patients who underwent EUS-TA and tumor sample evaluation for CGP analysis suitability between June 2019 and December 2021. The proportion of patients meeting the criteria was evaluated considering tumor size, puncture lesion, presence of metastasis, type and size of puncture needle, suction method, number of punctures, and puncture route. RESULTS: In total, 39.2% (60/153) of samples met NOP analysis suitability criteria and 0% met FOne analysis suitability criteria. The suitability rate was significantly higher with 19G fine-needle biopsy (FNB) (56.0%; 42/75) than with 22G FNB (32.6%; 14/43) and 22G fine-needle aspiration (11.4%; 4/35). Nineteen-gauge needle (odds ratio [OR] 2.53; 95% confidence interval [CI] 1.15-5.57; P = 0.021) and FNB (OR 3.57; 95% CI 1.05-12.20; P = 0.041) were independent factors contributing to NOP analysis suitability. Among 30 patients who underwent actual NOP analysis, the analysis success rate was 100% (30/30). CONCLUSION: In sample collection via EUS-TA, 19G and FNB needles contribute to NOP analysis suitability.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Pâncreas/diagnóstico por imagem , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patologia , Adenocarcinoma/patologia , Genômica , Neoplasias Pancreáticas
12.
J Gastroenterol ; 57(12): 990-998, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36190682

RESUMO

BACKGROUND: There are limited studies on the results of comprehensive genomic profiling testing for pancreatic cancer tissue specimens by endoscopic ultrasound-guided tissue acquisition (EUS-TA). This study aimed to evaluate the proportion of specimens obtained by EUS-TA using a 19-gauge (G) fine-needle biopsy (FNB) needle for unresectable pancreatic cancer (UR-PC) that met the OncoGuide™ NCC Oncopanel System (NOP) analysis suitability criteria. METHODS: In this single-arm, prospective, phase II study, EUS-TA was performed using a 19G FNB biopsy needle in patients with suspected UR-PC based on a contrast-enhanced computed tomography scan. The primary endpoint was the proportion of patients who met the NOP analysis suitability criteria, with a threshold, expected value, α-error, and power of 40%, 70%, 0.025, and 0.9, respectively, and the planned number of enrolled patients was 33. The NOP analysis suitability criteria were defined as tumor cell content ≥ 20% and tissue size ≥ 4 mm2. RESULTS: Thirty-three patients were enrolled. The procedural success rate was 100%, and the cytodiagnosis of class V was observed in all patients. The proportion of patients meeting the NOP analysis suitability criteria was 63.6% (95% CI 47.22-80.05), which satisfied the predefined criteria to be considered valid. Adverse events occurred in 9.0% of the patients. CONCLUSIONS: The proportion of patients with UR-PC who met the NOP analysis suitability criteria for EUS-TA using a 19G FNB needle was effective for achieving the primary endpoint, making it a valid test method. Adverse events occurred at a higher rate than that previously reported.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Estudos Prospectivos , Endossonografia , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas
13.
J Clin Med ; 11(14)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35887953

RESUMO

The diagnosis of autoimmune pancreatitis (AIP) and immunoglobulin G4-related sclerosing cholangitis (IgG4-SC) may require a somewhat invasive pathological examination and steroid responsiveness. This retrospective study assessed the complemental diagnosis of AIP and IgG4-SC using submandibular gland (SG) ultrasonography (US) in 69 patients, including 54 patients with AIP, 2 patients with IgG4-SC, and 13 patients with both AIP and IgG4-SC. The data from the physical examination and US of SGs to diagnose AIP (n = 67) and IgG4-SC (n = 15) were analyzed. The steroid therapy efficacy in resolving hypoechoic lesions in SGs was evaluated in 36 cases. The presence of IgG4-related pancreaticobiliary disease with multiple hypoechoic lesions in SGs was reduced from 31 to 11 cases after steroid therapy, suggesting that multiple hypoechoic lesions in SGs are strongly associated with IgG4-positive cell infiltrations. Multiple hypoechoic lesions in SGs were observed in 53 cases, whereas submandibular swelling on palpation was observed in 21 cases of IgG4-related pancreaticobiliary diseases. A complemental diagnosis of IgG4-related pancreaticobiliary diseases without a histological diagnosis and steroid therapy was achieved in 57 and 68 cases without and with multiple hypoechoic lesions in SGs, respectively. In conclusion, multiple hypoechoic lesions in SGs are useful for the complemental diagnosis of IgG4-related pancreaticobiliary diseases.

15.
Surg Endosc ; 36(12): 9001-9010, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35817882

RESUMO

BACKGROUND: In recent years, the number of patients with hepaticojejunostomy anastomotic strictures has increased. Balloon dilation and placement of multiple plastic stents have proven effective for hepaticojejunostomy anastomotic strictures. However, for refractory strictures, there is often a need for repeated endoscopic procedures within a short period. This study aimed to assess the efficacy and safety of the new saddle-cross technique, which uses two fully covered self-expandable metallic stents. METHODS: This was a retrospective analysis of 20 patients with benign hepaticojejunostomy anastomotic strictures who underwent placement of two fully covered self-expandable metallic stents at the National Cancer Center, Japan, from November 2017 to June 2021. RESULTS: The technical and clinical success rates were 100% (20/20). The median time of the procedure was 61 (range 25-122) min. The scheduled stent removal rate was 70% (14/20). Spontaneous dislodgement of the stent was observed on computed tomography in five patients (25.0%). The non-restenosis rate 12 months after the saddle-cross technique was 88.2% (15/17). Procedure-related early adverse events included mild ascending cholangitis in three patients (15.0%) and sepsis in one patient (5.0%). Procedure-related late adverse events included mild ascending cholangitis in three patients (15.0%) and bile duct hyperplasia in one patient (5.0%). CONCLUSIONS: The saddle-cross technique performed using two fully covered self-expandable metallic stents resulted in promising long-term stricture resolution with a high technical success rate. Based on these findings, the saddle-cross method can be considered an option for the standard procedure for benign hepaticojejunostomy anastomotic strictures.


Assuntos
Colangite , Stents Metálicos Autoexpansíveis , Humanos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Stents/efeitos adversos , Colangite/etiologia , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos
16.
J Hepatobiliary Pancreat Sci ; 29(9): 1035-1043, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35561015

RESUMO

BACKGROUND/PURPOSE: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) has many associated adverse events. We evaluated the clinical efficacy and safety of the laser-cut, fully covered, self-expandable metallic stent (FCSEMS) for this procedure. METHODS: This single-center, retrospective study included cases where EUS-HGS with a laser-cut FCSEMS was performed for malignant biliary obstruction. Technical and clinical success, time to recurrent biliary obstruction (TRBO), procedure time, adverse events, and re-interventions were evaluated. RESULTS: There were 95 eligible cases. Technical and clinical success rates were 100.0% and 95.8%, respectively. Median TRBO was 398 days. RBO causes were hyperplasia (7.4%), debris (3.2%), and migration (4.2%). Adverse events occurred in nine cases (9.5%). Non-occlusion and focal cholangitis occurred in four cases (4.2%) each. Nineteen patients (20%) underwent combined EUS-HGS (CH) procedures: antegrade stenting, bridging methods, plastic stent anchoring in SEMS, and EUS-hepaticoduodenostomy. The solely EUS-HGS (SH) group had significantly longer median TRBO than the CH group (398 vs 246 days, P = .04). There were no significant differences in adverse events between the two groups. Re-intervention was performed in 29 cases (technical success rate: 100.0%). CONCLUSIONS: Laser-cut FCSEMS can be safely placed in the bile duct and easily applied during re-intervention, making it useful in EUS-HGS.


Assuntos
Neoplasias dos Ductos Biliares , Colestase , Neoplasias dos Ductos Biliares/complicações , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Drenagem/métodos , Endossonografia/métodos , Humanos , Lasers , Plásticos , Estudos Retrospectivos , Stents/efeitos adversos , Ultrassonografia de Intervenção
17.
DEN Open ; 2(1): e56, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35310726

RESUMO

Objectives: To evaluate the feasibility and safety of endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) without fistula dilation using a novel self-expandable metal stent (SEMS). Methods: This retrospective study examined patients who underwent EUS-CDS for malignant distal biliary obstruction between October 2017 and May 2021 at the National Cancer Center, Japan. The primary outcome was a technical success without fistula dilation. Secondary outcomes were the overall technical success, clinical success, adverse events (AEs), procedure time, recurrent biliary obstruction (RBO), and time to RBO (TRBO). Results: Forty-one patients were enrolled; 31 patients underwent EUS-CDS with fistula dilation using a conventional SEMS with 7.5-8.5-Fr delivery system (conventional SEMS group), and 10 patients underwent EUS-CDS without fistula dilation using the novel SEMS with a 5.9-Fr delivery system (novel SEMS group). In the novel SEMS group, the rate of technical success without fistula dilation was 90%. There were no differences in overall technical success (100% vs. 97%, p = 1.00), clinical success (80% vs. 90%, p = 0.58), and overall AEs (10% vs. 23%, p = 0.65) rates between the novel and conventional SEMS groups. In the novel SEMS group, no early AEs were observed and no bile leakage into the abdominal cavity was observed on the computed tomography scan after the procedure. The median procedure time was significantly shorter in the novel SEMS group (17 min vs. 24 min, p = 0.03). RBO and median TRBO did not differ between the 2 groups. Conclusions: EUS-CDS without fistula dilation using the novel SEMS with a 5.9-Fr delivery system is technically feasible, straightforward, quick, and safe.

20.
Nihon Shokakibyo Gakkai Zasshi ; 117(2): 171-177, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-32037363

RESUMO

A 63-year-old man developed an infectious pancreatic pseudocyst after acute-on-chronic pancreatitis. The CT and MRI showed the pancreatic pseudocyst communicating with the left branch of the portal vein which now contained cystic fluid. The condition was diagnosed as a pancreatic pseudocyst-portal vein fistula. Because there was no appropriate route through which to drain the pseudocyst, the procedure was performed via the portal vein. The patient's symptoms rapidly improved after the procedure and no recurrence has been observed for three years. Here, we report a rare case of pancreatic pseudocyst-portal vein fistula treated by drainage via the portal vein.


Assuntos
Fístula Pancreática , Pseudocisto Pancreático , Veia Porta , Drenagem , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA