RESUMO
We investigated the effect of exercise intensity and tolerable duration on the development of exercise-induced diaphragm and expiratory muscle fatigue. Ten healthy adults (25 ± 5 yr; 2 females) cycled to intolerance on three separate occasions: 1) 5% below critical power (
Assuntos
Diafragma , Exercício Físico , Fadiga Muscular , Humanos , Fadiga Muscular/fisiologia , Masculino , Feminino , Diafragma/fisiologia , Diafragma/fisiopatologia , Adulto , Exercício Físico/fisiologia , Adulto Jovem , Consumo de Oxigênio/fisiologia , Músculos Respiratórios/fisiologia , Expiração/fisiologiaRESUMO
PURPOSE: Acute nonfatiguing inspiratory muscle loading transiently increases diaphragm excitability and global inspiratory muscle strength and may improve subsequent exercise performance. We investigated the effect of acute expiratory muscle loading on expiratory muscle function and exercise tolerance in healthy men. METHODS: Ten males cycled at 90% of peak power output to the limit of tolerance (TLIM) after 1) 2 × 30 expiratory efforts against a pressure-threshold load of 40% maximal expiratory gastric pressure (PgaMAX) (EML-EX) and 2) 2 × 30 expiratory efforts against a pressure-threshold load of 10% PgaMAX (SHAM-EX). Changes in expiratory muscle function were assessed by measuring the mouth pressure (PEMAX) and PgaMAX responses to maximal expulsive efforts and magnetically evoked (1 Hz) gastric twitch pressure (Pgatw). RESULTS: Expiratory loading at 40% of PgaMAX increased PEMAX (10% ± 5%, P = 0.001) and PgaMAX (9% ± 5%, P = 0.004). Conversely, there was no change in PEMAX (166 ± 40 vs 165 ± 35 cm H2O, P = 1.000) or PgaMAX (196 ± 38 vs 192 ± 39 cm H2O, P = 0.215) from before to after expiratory loading at 10% of PgaMAX. Exercise time was not different in EML-EX versus SHAM-EX (7.91 ± 1.96 vs 8.09 ± 1.77 min, 95% CI = -1.02 to 0.67, P = 0.651). Similarly, exercise-induced expiratory muscle fatigue was not different in EML-EX versus SHAM-EX (-28% ± 12% vs -26% ± 7% reduction in Pgatw amplitude, P = 0.280). Perceptual ratings of dyspnea and leg discomfort were not different during EML-EX versus SHAM-EX. CONCLUSION: Acute expiratory muscle loading enhances expiratory muscle function but does not improve subsequent severe-intensity exercise tolerance in healthy men.
Assuntos
Tolerância ao Exercício/fisiologia , Músculos Respiratórios/fisiologia , Adulto , Eletromiografia , Teste de Esforço , Humanos , Fenômenos Magnéticos , Masculino , Fadiga Muscular/fisiologia , Percepção/fisiologia , Esforço Físico/fisiologia , Nervos Torácicos/fisiologia , Adulto JovemRESUMO
In 11 healthy adults (25 ± 4 yr; 2 female, 9 male subjects), we investigated the effect of expiratory resistive loaded breathing [65% maximal expiratory mouth pressure (MEP), 15 breaths·min-1, duty cycle 0.5; ERLPm] on mean arterial pressure (MAP), leg vascular resistance (LVR), and leg blood flow ([Formula: see text]). On a separate day, a subset of five male subjects performed ERL targeting 65% of maximal expiratory gastric pressure (ERLPga). ERL-induced expiratory muscle fatigue was confirmed by a 17 ± 5% reduction in MEP (P < 0.05) and a 16 ± 12% reduction in the gastric twitch pressure response to magnetic nerve stimulation (P = 0.09) from before to after ERLPm and ERLPga, respectively. From rest to task failure in ERLPm and ERLPga, MAP increased (ERLPm = 31 ± 10 mmHg, ERLPga = 18 ± 9 mmHg, both P < 0.05), but group mean LVR and [Formula: see text] were unchanged (ERLPm: LVR = 0.78 ± 0.21 vs. 0.97 ± 0.36 mmHg·mL-1·min, [Formula: see text] = 133 ± 34 vs. 152 ± 74 mL·min-1; ERLPga: LVR = 0.70 ± 0.21 vs. 0.84 ± 0.33 mmHg·mL-1·min, [Formula: see text] = 160 ± 48 vs. 179 ± 110 mL·min-1) (all P ≥ 0.05). Interestingly, [Formula: see text] during ERLPga oscillated within each breath, increasing (â¼66%) and decreasing (â¼50%) relative to resting values during resisted expirations and unresisted inspirations, respectively. In conclusion, fatiguing expiratory muscle work did not affect group mean LVR or [Formula: see text] in otherwise resting humans. We speculate that any sympathetically mediated peripheral vasoconstriction was counteracted by transient mechanical effects of high intra-abdominal pressures during ERL.NEW & NOTEWORTHY Fatiguing expiratory muscle work in otherwise resting humans elicits an increase in sympathetic motor outflow; whether limb blood flow ([Formula: see text]) and leg vascular resistance (LVR) are affected remains unknown. We found that fatiguing expiratory resistive loaded breathing (ERL) did not affect group mean [Formula: see text] or LVR. However, within-breath oscillations in [Formula: see text] may reflect a sympathetically mediated vasoconstriction that was counteracted by transient increases in [Formula: see text] due to the mechanical effects of high intra-abdominal pressure during ERL.
Assuntos
Fadiga Muscular , Músculos Respiratórios , Adulto , Expiração , Feminino , Humanos , Masculino , Descanso , Resistência VascularRESUMO
The purpose of this report was to 1) detail the construction of a low-cost device that provides a "reference" flow waveform for pneumotachograph (PNT) calibration, i.e., the "syringe potentiometer" (SP), and to compare the 2) accuracy and 3) practical performance of "calibration curves" obtained with the SP device to other more established methods of PNT calibration, i.e., the weighted averaging (WA) and polynomial least-squares (PolyLS) methods. Volume and flow waveforms obtained via the SP device were validated against a motion capture system and were deemed accurate surrogates of actual syringe volume and flows. The SP device was used to construct a calibration curve of a PNT by dividing the flow waveform of the SP by the analog output of the PNT amplifier. A total of 187 inspiratory and 187 expiratory strokes were collected. When the entire data set of expiratory strokes was used, the SP, WA, and PolyLS methods together demonstrated acceptable volume and flow errors as per American Thoracic Society/European Respiratory Society recommendations (less than ±3.5% and less than ±5.0% errors, respectively). The "practical" performance of each method was assessed with a nested subsampling procedure, whereby volume and flow errors were evaluated as the number of strokes was increased (in blocks of 5 strokes). To this end, the SP method demonstrated practical performance superior to that of the WA and PolyLS approaches, whereby acceptable volume and flow errors were achieved after only 5 calibration strokes; the WA and PolyLS methods required 15 and 20 strokes, respectively, to achieve the same level of volume and flow accuracy.NEW & NOTEWORTHY This report describes the construction and validation of a low-cost device for the purposes of pneumotachograph (PNT) calibration: the "syringe potentiometer" (SP). Calibration of a PNT with the SP device yielded acceptable volume and flow errors (<3.5% and 5%, respectively) across a wide range of flows (<0.5 to 15 L/s). The SP device offered superior "practical performance" over other established PNT calibration methods, whereby acceptable volume and flow errors were achieved after only five calibration strokes.