Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Physiol Meas ; 43(11)2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36270506

RESUMO

Objectives.Clinical assessment of skin perfusion informs prognosis in critically ill patients. Video camera monitoring could provide an objective, continuous method to monitor skin perfusion. In this prospective, interventional study of healthy volunteers, we tested whether video camera-derived photoplethysmography imaging and colour measurements could detect drug-induced skin perfusion changes.Approach.We monitored the lower limbs of 30 volunteers using video cameras while administering phenylephrine (a vasoconstrictor) and glyceryl trinitrate (a vasodilator). We report relative pixel intensity changes from baseline, as absolute values are sensitive to environmental factors. The primary outcome was the pre- to peak- infusion green channel amplitude change in the pulsatile PPGi waveform component. Secondary outcomes were pre-to-peak changes in the photoplethysmographic imaging waveform baseline, skin colour hue and skin colour saturation.Main results.The 30 participants had a median age of 29 years (IQR 25-34), sixteen (53%) were male. A 34.7% (p= 0.0001) mean decrease in the amplitude of the pulsatile photoplethysmographic imaging waveform occurred following phenylephrine infusion. A 30.7% (p= 0.000004) mean increase occurred following glyceryl trinitrate infusion. The photoplethysmographic imaging baseline decreased with phenylephrine by 2.1% (p= 0.000 02) and increased with glyceryl trinitrate by 0.5% (p= 0.026). Skin colour hue changed in opposite direction with phenylephrine (-0.0013,p= 0.0002) and glyceryl trinitrate (+0.0006,p= 0.019). Skin colour saturation decreased with phenylephrine by 0.0022 (p= 0.0002), with no significant change observed with glyceryl trinitrate (+0.0005,p= 0.21).Significance.Drug-induced vasoconstriction and vasodilation are associated with detectable changes in photoplethysmographic imaging waveform parameters and skin hue. Our findings suggest video cameras have great potential for continuous, contactless skin perfusion monitoring.


Assuntos
Nitroglicerina , Vasodilatação , Humanos , Masculino , Adulto , Feminino , Nitroglicerina/farmacologia , Vasoconstrição , Estudos Prospectivos , Vasodilatadores/farmacologia , Fenilefrina/farmacologia , Perfusão
2.
Physiol Meas ; 40(6): 06TR01, 2019 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-31051494

RESUMO

OBJECTIVE: Over the last 15 years, developments in camera technology have coincided with increased availability and affordability. This has led to an increasing interest in using these technologies in healthcare settings. Image-based monitoring methods potentially allow multiple vital signs to be measured concurrently using a non-contact sensor. We have undertaken a systematic review of the current availability and performance of these monitoring methods. APPROACH: A multiple database search was conducted using MEDLINE, Embase, CINAHL, Cochrane Library, OpenGrey, IEEE Xplore Library and ACM Digital Library to July 2018. We included studies comparing image-based heart rate, respiratory rate, oxygen saturation and blood pressure monitoring methods against one or more validated reference device(s). Each included study was assessed using the modified GRRAS criteria for reporting bias. MAIN RESULTS: Of 30 279 identified studies, 161 were included in the final analysis. Twenty studies (20/161, 12%) were carried out on patients in clinical settings, while the remainder were conducted in academic settings using healthy volunteer populations. The 18-40 age group was best represented across the identified studies. One hundred and twenty studies (120/161, 75%) estimated heart rate, followed by 62 studies (62/161, 39%) estimating respiratory rate. Fewer studies focused on oxygen saturation (11/161, 7%) or blood pressure (6/161, 4%) estimation. Fifty-one heart rate studies (51/120, 43%) and 24 respiratory rate studies (24/62, 39%) used Bland-Altman analysis to report their results. Of the heart rate studies, 28 studies (28/51, 55%) showed agreement within industry standards of [Formula: see text]5 beats per minute. Only two studies achieved this within clinical settings. Of the respiratory rate studies, 13 studies (13/24, 54%) showed agreement within industry standards of [Formula: see text]3 breaths per minute, but only one study achieved this in a clinical setting. Statistical analysis was heterogeneous across studies with frequent inappropriate use of correlation. The majority of studies (99/161, 61%) monitored subjects for under 5 min. Three studies (3/161, 2%) monitored subjects for over 60 min, all of which were conducted in hospital settings. SIGNIFICANCE: Heart rate and respiratory rate monitoring using video images is currently possible and performs within clinically acceptable limits under experimental conditions. Camera-derived estimates were less accurate in the proportion of studies conducted in clinical settings. We would encourage thorough reporting of the population studied, details of clinically relevant aspects of methodology, and the use of appropriate statistical methods in future studies. Systematic review registration: PROSPERO CRD42016029167 Protocol: https://systematicreviewsjournal.biomedcentral.com/articles/10.1186/s13643-017-0615-3.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Processamento de Imagem Assistida por Computador , Monitorização Fisiológica , Oxigênio/metabolismo , Taxa Respiratória/fisiologia , Adolescente , Adulto , Etnicidade , Feminino , Geografia , Humanos , Recém-Nascido , Masculino , Pressão Parcial , Pigmentação da Pele , Sinais Vitais , Adulto Jovem
3.
Curr Genet ; 11(4): 315-9, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-2834096

RESUMO

Passaging on selective media of yeast strains transformed with complete 2 micron vectors carrying TRP1, LEU2 or URA3 selective markers leads to curing of the resident endogenous 2 micron DNA in a majority of the population. Vector plasmids defective in FLP function are fixed as populations of A, A + B or B forms after 2 micron loss. Transformation with these plasmids offers a general method of obtaining cir degree derivatives of any yeast strain.


Assuntos
DNA Recombinante/metabolismo , Vetores Genéticos , Saccharomyces cerevisiae/genética , Enzimas de Restrição do DNA , Hibridização de Ácido Nucleico , Plasmídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA