Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mater Sci Eng C Mater Biol Appl ; 69: 1036-42, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27612800

RESUMO

Light Curing Units (LCUs) are used daily in almost every dental office to photocure resins, but because the light is so bright, the user is unable to tell visually if there are any differences between different LCUs. This study evaluated the light output from six dental LCUs: Elipar Deep Cure-S (3M ESPE), Bluephase G2 (Ivoclar Vivadent), Translux 2Wave (Heraeus Kulzer), Optilight Prime (Gnatus), Slim Blast (First Medica) and Led.B (Guilin Woodpecker) with a fully charged battery, after 50, and again after 100, 20second light exposures. For each situation, the radiant power was measured 10 times with a laboratory-grade power meter. Then, the emission spectrum was measured using a fiber-optic spectrometer followed by an analysis of the light beam profile. It was found there were significant differences in the LCU power and the irradiance values between the LCUs (p<0.01). The Optilight Prime and Slim Blast LCUs showed a significant reduction in light output after a 50 and 100 exposures, while Bluephase G2 exhibited a significant reduction only after 100 exposures (p<0.01). The Bluephase G2 and Translux 2Wave delivered an emission spectrum that had two distinct wavelength emission peaks. Only the Elipar Deep Cure-S and Bluephase G2 LCUs displayed homogeneous light beam profiles, the other LCUs exhibited highly non-homogeneous light beam profiles. It was concluded that contemporary LCUs could have very different light output characteristics. Both manufacturers and researchers should provide more information about the light output from LCUs.


Assuntos
Lâmpadas de Polimerização Dentária , Fontes de Energia Elétrica , Luz , Espectrometria de Fluorescência , Estatística como Assunto
2.
J Dent ; 54: 48-55, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27597433

RESUMO

OBJECTIVES: To evaluate the accuracy of four dental radiometers when measuring the output from nine light curing units (LCUs). METHODS: The light output from nine light-emitting diode LCUs was measured with a laboratory-grade power meter (PowerMax-Pro 150 HD) and four dental radiometers (Bluephase Meter II, SDI LED Radiometer, Kerr LED Radiometer, and LEDEX CM4000). Ten measurements were made of each LCU with each radiometer. Analysis of variance (ANOVA) followed by Tukey tests (α=0.05) were used to determine if there was a difference between the calculated irradiance values from the power meter and those from the radiometers. Where applicable, the LCUs were ranked according to their power and irradiance values. The emission spectra from the LCUs was measured using an integrating sphere attached to a fiber-optic spectrometer (N=10). The beam profile of the LCUs was measured with a beam profiler camera. RESULTS: Of the dental radiometers, only the Bluephase Meter II could measure power. ANOVA showed no significant difference between power values measured with the laboratory-grade meter and the Bluephase Meter II (p=0.527). The difference between the mean irradiance reported by the various radiometers for the same LCU was up to 479mW/cm2. The ranking of the power values obtained using the laboratory-grade meter was the same for the Bluephase Meter II. CONCLUSION: When compared to the calculated irradiance values from the laboratory-grade power meter, the Bluephase Meter II provided the most accurate data. CLINICAL SIGNIFICANCE: Considering the great variation between the irradiance values provided by radiometers and their overall inaccuracy when compared to a laboratory-grade meter, dentists should not place too much faith in the absolute irradiance value. However, hand-held radiometers can be used to monitor changes in the light output of LCUs over time.


Assuntos
Radiometria , Análise de Variância , Resinas Compostas , Lâmpadas de Polimerização Dentária , Equipamentos Odontológicos , Luz , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA