Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
BMC Vet Res ; 20(1): 341, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095829

RESUMO

BACKGROUND: The insulin-like growth factor (IGF-I) and growth hormone (GH) genes have been identified as major regulators of milk yield and composition, and reproductive performance in cattle. Genetic variations/polymorphism in these genes have been found to influence milk production, yield and quality. This investigation aimed to explore the association between IGF-I and GH polymorphisms and milk yield and composition, and reproductive performance in a herd consisting of 1000 Holstein-Friesian (HF) dairy cattle from El-Alamia farm. The experimental animals were 76 ± 7.25 months in age, with an average live weight of 750 ± 50.49 kg, and raised under the same conditions of feeding and weather. The studied animals were divided into three categories; high producers (n = 280), medium producers (n = 318) and low producers (n = 402). RESULTS: The digestion of 249 bp for IGF-I-SnaBI using the Restriction-fragment-length-polymorphism (RFLP) technique yielded two alleles; T (0.59) and C (0.41) and three genotypes; TT (0.52), TC (0.39) and CC (0.09) and this agrees with the results of DNA/gene sequencing technique. The sequencing analysis of the IGF-I gene revealed polymorphism in position 472 (C > T). Nucleotide sequencing of the amplified fragment of the IGF-I gene of different genotypes was done and submitted to the NCBI GenBank with Accession no. MH156812.1 and MH156811.1. While the digestion of 432 bp for GH-AluI using the RFLP technique yielded two alleles; A (0.81) and G (0.19) and two genotypes; AA (0.77) and AG (0.23) and this agrees with the results of DNA/gene sequencing technique. The sequencing analysis of the GH gene revealed polymorphism in the position 1758 C > G and in turn led to changes in amino acid sequence as Alanine for (A) compared to Glycine for (G). Nucleotide sequencing of the amplified fragment of the GH gene was done and submitted to the NCBI GenBank with Accession no. MH156810.1. The results of this study demonstrate the effects of variants of the GH-IGF-I somatotrophic axis on milk production and composition traits in commercial HF cattle. The greatest values of milk yield and reproductive performance were observed on IGF-I-SnaBI-TC and GH-AluI-AG genotypes. While the greatest % fat and % protein values were observed on IGF-I-SnaBI-CC and GH-AluI-AA genotyped individuals. CONCLUSION: The genetic variation of the studied genes can be utilized in selecting animals with superior milk yield, composition and reproductive performance in Holstein-Friesian Dairy Cattle under subtropical conditions.


Assuntos
Hormônio do Crescimento , Fator de Crescimento Insulin-Like I , Lactação , Leite , Reprodução , Animais , Bovinos/genética , Bovinos/fisiologia , Fator de Crescimento Insulin-Like I/genética , Fator de Crescimento Insulin-Like I/metabolismo , Leite/química , Leite/metabolismo , Hormônio do Crescimento/genética , Feminino , Reprodução/genética , Lactação/genética , Polimorfismo Genético , Genótipo , Polimorfismo de Fragmento de Restrição
3.
Artigo em Inglês | MEDLINE | ID: mdl-39033340

RESUMO

PURPOSE: The aim of this study was to conduct a systematic review and meta-analysis on the reliability and applicability of artificial intelligence (AI)-based analysis of leg axis parameters. We hypothesized that AI-based leg axis measurements would be less time-consuming and as accurate as those performed by human raters. METHODS: The study protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO). PubMed, Epistemonikos, and Web of Science were searched up to 24 February 2024, using a BOOLEAN search strategy. Titles and abstracts of identified records were screened through a stepwise process. Data extraction and quality assessment of the included papers were followed by a frequentist meta-analysis employing a common effect/random effects model with inverse variance and the Sidik-Jonkman heterogeneity estimator. RESULTS: A total of 13 studies encompassing 3192 patients were included in this meta-analysis. All studies compared AI-based leg axis measurements on long-leg radiographs (LLR) with those performed by human raters. The parameters hip knee ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and joint-line convergence angle (JLCA) showed excellent agreement between AI and human raters. The AI system was approximately 3 min faster in reading standing long-leg anteroposterior radiographs (LLRs) compared with human raters. CONCLUSION: AI-based assessment of leg axis parameters is an efficient, accurate, and time-saving procedure. The quality of AI-based assessment of the investigated parameters does not appear to be affected by the presence of implants or pathological conditions. LEVEL OF EVIDENCE: Level I.

4.
JBI Evid Implement ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39036875

RESUMO

INTRODUCTION: Advance care planning (ACP) ensures that patients receive medical care aligned with their values, goals, and preferences, especially regarding end-of-life decisions in serious chronic illnesses. OBJECTIVE: This project aimed to introduce and promote evidence-based ACP in oncology and palliative care at a midsized hospital near Berlin, Germany, during the COVID-19 pandemic. METHODS: This project was guided by the JBI Evidence Implementation Framework and used a mixed methods audit cycle. A baseline audit was conducted using qualitative interviews and workshops with representatives from all the health care disciplines involved in oncology and palliative care at the hospital. The findings were compared with eight best practice recommendations. Targeted strategies aimed at the key stakeholders involved in ACP practice were then implemented. Finally, a semi-quantitative questionnaire was used in a follow-up audit with the same participants as in the baseline audit. RESULTS: The baseline audit revealed a high level of familiarity with the concept of ACP. However, there was a lack of a uniformly accepted definition and understanding of ACP among the health care professionals, leading to a lack of coordination in task distribution. The follow-up audit revealed improvements with regard to education and training in ACP (Criterion 1: 50% to 100%) and organizational support to facilitate ACP conversations (Criterion 3: 87.5% to 100%). Other audit criteria compliance rates remained unchanged. CONCLUSION: Clinical education and team-based process analysis can facilitate ACP implementation across disciplines in oncology and palliative care facilities. However, the project did not succeed in implementing lasting changes in clinical processes and best practice ACP due to the COVID-19 pandemic. Such an endeavor would demand considerable resources and time, both of which were constrained during the pandemic. SPANISH ABSTRACT: http://links.lww.com/IJEBH/A236.

5.
J Orthop Surg Res ; 19(1): 384, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951886

RESUMO

BACKGROUND: It remains unclear whether the use of an orthopaedic traction table (TT) in direct anterior approach (DAA) total hip arthroplasty (THA) results in better outcomes. The aim of this systematic review and network meta-analysis was to compare the THA outcomes through DAA on a standard operating table and the THA outcomes through DAA on a TT. METHODS: PubMed, Epistemonikos, and Google Scholar were searched for relevant randomized controlled trials (RCTs) up to 01 January 2024. An indirect comparison in network meta-analysis was performed to assess treatment effects between DAA on a TT and DAA on a standard table, using fixed-effects and random-effects models estimated with frequentist approach and consistency assumption. Standardized mean differences (SMDs) with 95% confidence intervals (CIs) were estimated for continuous variables and odds ratios (ORs) with 95% CIs were estimated for binary variables. RESULTS: The systematic review of the literature identified 43 RCTs with a total of 2,258 patients. DAA with TT had a 102.3 mL higher intraoperative blood loss and a 0.6 mmol/L lower Hb 3 days postoperatively compared with DAA without TT (SMD = 102.33, 95% CI 47.62 to 157.04; SMD = - 0.60, 95% CI - 1.19 to - 0.00). DAA with TT had a 0.15 lower periprosthetic fracture OR compared with DAA without TT (OR 0.15, 95% CI 0.03 to 0.86). There were no further significant differences in surgical, radiological, functional outcomes and in complication rates. CONCLUSION: Based on our findings and taking into account the limitations, we recommend that particular attention be paid to the risk of periprosthetic fracture in DAA on a standard operating table and blood loss in DAA with TT. Since numerous other surgical, radiological, functional outcome parameters and other complication rates studied showed no significant difference between DAA on a standard operating table and DAA with TT, no recommendation for a change in surgical technique seems justified. LEVEL OF EVIDENCE: Level I evidence, because this is a systematic review and meta-analysis of randomized controlled trials.


Assuntos
Artroplastia de Quadril , Metanálise em Rede , Tração , Humanos , Artroplastia de Quadril/métodos , Tração/métodos , Resultado do Tratamento , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Mesas Cirúrgicas , Ensaios Clínicos Controlados Aleatórios como Assunto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia
6.
Medicine (Baltimore) ; 103(30): e39068, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058802

RESUMO

BACKGROUND: The aim of the study was to compare the short-term outcome of SuperPATH, direct anterior (DAA) and conventional approach (CA) hemiarthroplasty (HA) in patients with femoral neck fractures using a network meta-analysis. METHODS: PubMed, China National Knowledge Infrastructure, Epistemonikos, and Embase were searched until May 31, 2024. In a network meta-analysis, mean differences with 95% confidence intervals were calculated using the Hartung-Knapp-Sidik-Jonkman method and a fixed/random effects model for continuous outcomes, and odds ratios with 95% confidence intervals were calculated using the Mantel-Haenszel method and a fixed/random effects model for dichotomous outcomes. RESULTS: The literature search identified a total of 9 randomized controlled trials on SuperPATH with 762 patients and 8 randomized controlled trials on DAA with 641 patients. In the overall ranking, SuperPATH was placed first, DAA second and CA third. SuperPATH HA was best in 7, second best in 2 and third best in 1 of the 10 outcome parameters. DAA HA was best in 2 and second best in 8 of the 10 outcome parameters. CA HA was best in 1 and third best in 9 of the 10 outcome parameters. In the indirect comparison between SuperPATH HA and DAA HA, SuperPATH HA had a 1.36 point lower visual analog scale at 2 to 7 days postoperatively and a 0.17 lower overall complication rate compared to DAA. CONCLUSION: For the treatment of patients with femoral neck fractures, SuperPATH HA ranked first, DAA HA ranked second and CA HA ranked third. Based on the results, we recommend that trauma surgeons increase their use of minimally invasive hip HA techniques. It should be noted that SuperPATH HA had a significantly lower overall complication rate compared to DAA HA when the minimally invasive technique was chosen.


Assuntos
Fraturas do Colo Femoral , Hemiartroplastia , Metanálise em Rede , Fraturas do Colo Femoral/cirurgia , Humanos , Hemiartroplastia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia
7.
Medicina (Kaunas) ; 60(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38929468

RESUMO

Background and Objectives: Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Materials and Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. Results: A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. Conclusions: The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.


Assuntos
Músculo Esquelético , Humanos , Reprodutibilidade dos Testes , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Testes Diagnósticos de Rotina/normas , Testes Diagnósticos de Rotina/métodos
8.
J Craniofac Surg ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838365

RESUMO

BACKGROUND: Children with repaired cleft lip and palate may present with middle ear effusion and disturbed speech due to velopharyngeal (VP) insufficiency. Furlow Z-palatoplasty with a buccinator myomucosal flap is one of the effective surgical techniques for primary cleft palate repair and lengthening of the palate. PURPOSE OF THE STUDY: This study aimed to evaluate the effect of Furlow Z-palatoplasty with buccal myomucosal flap as a primary cleft palate repair technique on the VP function during speech and the Eustachian tube function. MATERIALS AND METHODS: Forty patients with non-syndromic cleft lip and palate aged 3 to 7 years surgically repaired with Furlow palatoplasty with a buccinator myomucosal flap were assessed. Perceptual speech assessment, nasopharyngoscopic examination, otoscopic examination, and tympanometry were done for all patients to assess the speech and middle ear function. RESULTS: The percentage of mild hypernasality was significant in 22.5% of children with repaired cleft lip and palate, while 77.5% showed no hypernasality. Speech intelligibility was normal in 77.5% and mildly affected in 22.5% of children with repaired cleft palate. Compensatory misarticulations were recorded in 12.5% of children. Nasopharyngoscopic examination revealed adequate VP closure in 75% of children with repaired cleft palate. Twenty-five percent of children with repaired cleft lip and palate had middle ear effusion and required myringotomy with insertion of tympanostomy tubes. CONCLUSION: Primary cleft palate repair with Furlow Z-palatoplasty with buccal myomucosal flap had beneficial effects on speech outcomes. It was associated with a low prevalence of middle ear effusion, and a low number of tympanostomy tubes were needed.

9.
Circulation ; 149(25): 1949-1959, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38752352

RESUMO

BACKGROUND: Sildenafil, approved for pulmonary arterial hypertension (PAH), has a recommended adult dose of 20 mg TID, with a previously approved 5-mg TID dose by the US Food and Drug Administration. Safety concerns arose because of common off-label use of higher doses, particularly after pediatric data linked higher doses to increased mortality. To assess this, the Food and Drug Administration mandated a study evaluating the effects of various sildenafil doses on mortality in adults with PAH. METHODS: This randomized, double-blind study compared sildenafil at doses of 5, 20, or 80 mg TID in adults with PAH. The primary objective was noninferiority of 80 mg of sildenafil versus 5 mg for all-cause mortality. Secondary end points included time to clinical worsening and change in 6-minute walk distance at 6 months. Interim analyses were planned at 50% and 75% of the anticipated mortality events. Safety and tolerability were assessed in the intention-to-treat population. RESULTS: The study was halted after the first interim analysis, demonstrating noninferiority for 80 mg of sildenafil versus 5 mg. Of 385 patients enrolled across all dose groups, 78 died. The primary analysis showed a hazard ratio of 0.51 (99.7% CI, 0.22-1.21; P<0.001 for noninferiority) for overall survival comparing 80 mg of sildenafil with 5 mg. Time to clinical worsening favored 80 mg of sildenafil compared with 5 mg (hazard ratio, 0.44 [99.7% CI, 0.22-0.89]; P<0.001). Sildenafil at 80 mg improved 6-minute walk distance from baseline at 6 months compared with 5 mg (least square mean change, 18.9 m [95% CI, 2.99-34.86]; P=0.0201). No significant differences were found between 80 mg of sildenafil and 20 mg in mortality, clinical worsening, and 6-minute walk distance. Adverse event-related drug discontinuations were numerically higher with 80 mg of sildenafil. CONCLUSIONS: Sildenafil at 80 mg was noninferior to sildenafil at 5 mg when examining all-cause mortality in adults with PAH. Secondary efficacy end points favored 80 mg of sildenafil over 5 mg. On the basis of these findings, the Food and Drug Administration recently revoked the approval of 5 mg of sildenafil for adults with PAH, reinforced 20 mg TID as the recommended dose, and now allows dose titration up to 80 mg TID, if needed. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02060487.


Assuntos
Citrato de Sildenafila , Humanos , Citrato de Sildenafila/administração & dosagem , Citrato de Sildenafila/uso terapêutico , Citrato de Sildenafila/efeitos adversos , Feminino , Masculino , Pessoa de Meia-Idade , Método Duplo-Cego , Adulto , Relação Dose-Resposta a Droga , Hipertensão Arterial Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/mortalidade , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/mortalidade , Idoso , Vasodilatadores/administração & dosagem , Vasodilatadores/efeitos adversos , Vasodilatadores/uso terapêutico , Resultado do Tratamento , Teste de Caminhada , Inibidores da Fosfodiesterase 5/administração & dosagem , Inibidores da Fosfodiesterase 5/efeitos adversos , Inibidores da Fosfodiesterase 5/uso terapêutico
10.
J Orthop Surg Res ; 19(1): 311, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802945

RESUMO

BACKGROUND: The aim of the present study was to investigate the influence of various factors, in particular operation time, on mortality and complication rates in patients with femoral neck fractures who have undergone hip hemiarthroplasty (HHA) and to determine a cut-off value above which mortality and complication rates increase significantly. METHODS: Cases of patients with femoral neck fracture treated with HHA between 1 January 2017 and 31 December 2023 were screened for eligibility. Multiple logistic regressions were calculated to determine which factors (patient age, experience of surgeon, patient sex, ASA score, time to surgery, operation time) influenced the incidence of complications and mortality. The exact cut-off value for complications and mortality was determined using the Youden index of the ROC curve (sensitivity vs. specificity) of logistic regression. RESULTS: A total of 552 patients were considered eligible for this study. During the 90-day follow-up period after HHA, 50 deaths and 34 complications were recorded, giving a mortality rate of 9.1%, and a complication rate of 6.2%. Of the 34 complications recorded, 32.3% were infections, 14.7% dislocations, 20.7% trochanteric avulsions, 11.8% periprosthetic fractures, 11.8% nerve injuries, and 8.8% deep vein thrombosis. The odds ratio (OR) of a patient experiencing a complication is 2.2% higher for every minute increase in operation time (Exponential Beta - 1 = 0.022; p = 0.0363). The OR of a patient dying is 8.8% higher for each year increase in age (Exponential Beta - 1 = 0.088; p = 0.0007). When surgery was performed by a certified orthopaedic surgeon the mortality rate lowered by 61.5% in comparison to the surgery performed by a trainee (1 - Exponential Beta = 0.594; p = 0.0120). Male patients have a 168.7% higher OR for mortality than female patients (Exponential Beta - 1 = 1.687; p = 0.0017). Patients with an operation time of ≥ 86 min. have a 111.8% higher OR for mortality than patients with an operation time of < 86 min. (Exponential Beta - 1 = 1.118). CONCLUSION: This retrospective data analysis found that the risk of a patient experiencing a complication was 2.2% higher for every minute increase in operation time. Patients with an operation time above the cut-off of 86 min had a 111.8% higher risk of mortality than those with an operation time below the cut-off. Other influencing factors that operators should be aware of include patient age, male sex, and operator experience.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Duração da Cirurgia , Complicações Pós-Operatórias , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/mortalidade , Pessoa de Meia-Idade
11.
Artigo em Inglês | MEDLINE | ID: mdl-38780774

RESUMO

INTRODUCTION: Anterior knee pain commonly affects young women resulting in the declination of the quality of life. One of the possible pathologies causing this symptom is chondromalacia patellae (CMP). Although CMP is used to describe the softening of patellar articular cartilage, it remains a general descriptive term as it cannot be associated with a specific pathophysiologic mechanism. The objective of this study is to investigate the effect of injectable PRP on patients with anterior knee pain in absence of altered patellofemoral joint anatomy. METHODS: For this purpose, 43 patients of the affected population were recruited to participate in this non-randomized controlled trial, 28 patients in the injection group and 15 in the only-physiotherapy group. While patients in the experimental group received three PRP injections and one injection of hyaluronic acid (HA), comparators received the standard physical therapy regimen. The treatment choice was based on patients own decree. Patients between the ages of 18 to 50 years with anterior knee pain and positive Clarke´s sign were eligible for inclusion. Patients with evident anatomical abnormalities, chronic conditions affecting the knee and severe symptoms such as blocking, were excluded from the study. Patient related measures (PROMS) in the form of the VAS and the Kujala scores were the main outcome of interest. All outcomes were measured at baseline, and after 3 and 6 months after the treatment. RESULTS: Although an improvement was seen in both groups, a statistically significant difference favoring the injection of PRP over the physiotherapy-only group was observed (p < 0.001). The superiority of the therapeutic modality under investigation was observed at 3 and 6 months after the initial diagnosis was made. Furthermore, the results of this study revealed a significant improvement at 3 and 6 months when compared to baseline measures. The analysis of the patients age showed a negative correlation when baseline values were compared to measures at 3 and 6 months, meaning younger patients had more benefit from the treatment. DISCUSSION: The main results of this study affirm the positive effects of PRP and HA for the treatment of anterior knee pain described by previous research and the subsequent improvement of the quality of life. Relatively little information was found in the literature search regarding the therapeutic effects of PRP on anterior knee pain and chondropathies. While a previous radiologic study found no evidence regarding the effect of PRP, this study found a benefit when comparing PROMs between patient groups.

12.
Pharmaceuticals (Basel) ; 17(4)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38675441

RESUMO

An inflammation-resolving polysialic acid-decorated PLGA nanoparticle (PolySia-NP) has been developed to treat geographic atrophy/age-related macular degeneration and other conditions caused by macrophage and complement over-activation. While PolySia-NPs have demonstrated pre-clinical efficacy, this study evaluated its systemic and intraocular safety. PolySia-NPs were evaluated in vitro for mutagenic activity using Salmonella strains and E. coli, with and without metabolic activation; cytotoxicity was evaluated based on its interference with normal mitosis. PolySia-NPs were administered intravenously in CD-1 mice and Sprague Dawley rats and assessed for survival and toxicity. Intravitreal (IVT) administration in Dutch Belted rabbits and non-human primates was assessed for ocular or systemic toxicity. In vitro results indicate that PolySia-NPs did not induce mutagenicity or cytotoxicity. Intravenous administration did not show clastogenic activity, effects on survival, or toxicity. A single intravitreal (IVT) injection and two elevated repeat IVT doses of PolySia-NPs separated by 7 days in rabbits showed no signs of systemic or ocular toxicity. A single IVT inoculation of PolySia-NPs in non-human primates demonstrated no adverse clinical or ophthalmological effects. The demonstration of systemic and ocular safety of PolySia-NPs supports its advancement into human clinical trials as a promising therapeutic approach for systemic and retinal degenerative diseases caused by chronic immune activation.

13.
J Pers Med ; 14(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38541043

RESUMO

BACKGROUND: The investigation of soft tissue stiffness has garnered increasing interest due to its potential applications in detecting tissue conditions, monitoring therapy effects, and preventing sports injuries. This study utilized the MyotonPro as a reliable measurement device to assess muscle stiffness and muscle frequency in the vastus lateralis and medialis muscles of both the dominant and non-dominant legs. METHODS: Sixteen young, healthy subjects (seven males and nine females, age 25 ± 3.46 years) participated in this study. To induce maximal muscle fatigue, the vastus lateralis and vastus medialis muscles were subjected to a 30 kg load using a single-leg leg press. Pre- and post-fatigue measurements were conducted by two testers on the dominant and non-dominant legs, respectively, employing the MyotonPro. RESULTS: We revealed a significant increase in muscle stiffness after maximal muscle fatigue. Specifically, on the dominant side, the vastus lateralis exhibited a stiffness increase of 6.5%, while the vastus medialis showed a 6.3% increase. On the non-dominant side, the vastus lateralis demonstrated a 7.6% increase, and the vastus medialis exhibited a 6.7% increase in muscle stiffness. Furthermore, muscle frequency increased by 8.6% (vastus lateralis) and 13.5% (vastus medialis) on the dominant side and by 15.1% (vastus lateralis) and 6.3% (vastus medialis) on the non-dominant side. The reliability of the measurements varied, with Cronbach's alpha values ranging from inadequate 0.49 to very good 0.88. CONCLUSION: This study affirms the efficacy of the MyotonPro as a measurement device for assessing muscle stiffness and establishes its reliability. The observed increase in muscle stiffness after maximal muscle fatigue, accompanied by changes in muscle frequency, underscores the device's utility. However, further research is warranted to validate the reproducibility of these findings and explore additional facets of the muscular response to fatigue.

14.
JMIR Form Res ; 8: e52164, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363631

RESUMO

BACKGROUND: As large language models (LLMs) are becoming increasingly integrated into different aspects of health care, questions about the implications for medical academic literature have begun to emerge. Key aspects such as authenticity in academic writing are at stake with artificial intelligence (AI) generating highly linguistically accurate and grammatically sound texts. OBJECTIVE: The objective of this study is to compare human-written with AI-generated scientific literature in orthopedics and sports medicine. METHODS: Five original abstracts were selected from the PubMed database. These abstracts were subsequently rewritten with the assistance of 2 LLMs with different degrees of proficiency. Subsequently, researchers with varying degrees of expertise and with different areas of specialization were asked to rank the abstracts according to linguistic and methodological parameters. Finally, researchers had to classify the articles as AI generated or human written. RESULTS: Neither the researchers nor the AI-detection software could successfully identify the AI-generated texts. Furthermore, the criteria previously suggested in the literature did not correlate with whether the researchers deemed a text to be AI generated or whether they judged the article correctly based on these parameters. CONCLUSIONS: The primary finding of this study was that researchers were unable to distinguish between LLM-generated and human-written texts. However, due to the small sample size, it is not possible to generalize the results of this study. As is the case with any tool used in academic research, the potential to cause harm can be mitigated by relying on the transparency and integrity of the researchers. With scientific integrity at stake, further research with a similar study design should be conducted to determine the magnitude of this issue.

15.
Orthop Surg ; 16(4): 791-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38298174

RESUMO

Specialist literature lacks evidence that explores associations between patient characteristics and the beneficial treatment effect of SuperPATH hemiarthroplasty (HA) compared with conventional approach (CA) HA. To investigate and identify patient-related predictors of the effect size of the short-term functional outcome of SuperPATH HA and CA HA by performing a systematic review and meta-regression analysis of randomized controlled trials (RCTs). A systematic search of literature was performed in PubMed, CNKI, CENTRAL of The Cochrane Library, Clinical trials, and Google Scholar until August 25, 2023. For the continuous outcome parameter Harris hip score (HHS) ≤1 week and 3 months postoperatively, mean differences (MDs) with 95% confidence intervals (CIs) were calculated. A meta-regression analysis was based on random-effects meta-analysis using the Hartung-Knapp-Sidik-Jonkman method for continuous covariates. A total of five RCTs with 404 patients were found. The following predictors of HHS ≤1 week postoperatively were identified: patient age (predictor estimate = 1.29; p < 0.01), patient age groups (predictor estimate = 14.07; p < 0.01), time to mobilization (predictor estimate = 5.51; p < 0.01). The following predictors of HHS 3 months postoperatively were identified: incision length (predictor estimate = -2.12; p < 0.01); intraoperative blood loss (predictor estimate = 0.02; p < 0.01). Patient age, time to mobilization, incision length, and intraoperative blood loss were identified as predictors of the effect size of early postoperative functional outcome as measured by HHS. Elderly patients, particularly those over 70 years of age, appear to benefit from SuperPATH HA. Based on these findings, and taking into account our limitations, we recommend that the use of minimally invasive SuperPATH HA in elderly patients should be more widely considered and not limited to elective THA patients.


Assuntos
Hemiartroplastia , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Hemiartroplastia/métodos , Artroplastia de Quadril/métodos
16.
Retina ; 44(2): 222-229, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37903288

RESUMO

PURPOSE: Although pivotal trials have demonstrated efficacy of anti-vascular endothelial growth factor therapy in neovascular age-related macular degeneration, there is a paucity of clinical data about the long-term (>5 years) treatment. METHODS: Retrospective analysis of all patients with neovascular age-related macular degeneration who were actively treated, had received >40 anti-vascular endothelial growth factor injections, and were followed for ≥5 years. Snellen-corrected visual acuity, initial drug choice, and times elapsed between treatments were collected. Rates of endophthalmitis and outcomes of submacular hemorrhage were also evaluated. RESULTS: A total of 88 patients (162 eyes) met the inclusion criteria: the average patient age was 86.3 years with an average follow-up period of 7.6 years. The average total number of injections per eye was 69 (18.0 SD); a total of 11,208 injections were given throughout the study period, and 6 cases (0.05%) of endophthalmitis were observed. Overall, there was a clinical and statistical difference in average Snellen-corrected visual acuity at Injections #2,#3, #4, #5, #6, #10, and #20, as compared with baseline ( P = 0.03, P < 0.01, P = 0.02, P < 0.01, P = 0.01, P = 0.01, P < 0.01, respectively). Patients in the Snellen-corrected visual acuity subgroup 20/20 to 20/40 maintained vision until injection #30. Seven eyes experienced a visually significant submacular hemorrhage. CONCLUSION: This neovascular age-related macular degeneration cohort received on average eight anti-vascular endothelial growth factor injections per year for approximately 8 years; eyes with good (≥20/40) initial baseline vision maintained their visual acuity, whereas those with worse Snellen-corrected visual acuity (≤20/50) had a robust initial improvement that diminished with time. Most patients were maintained on the same initial drug of choice and the rate of endophthalmitis was low.


Assuntos
Endoftalmite , Degeneração Macular , Degeneração Macular Exsudativa , Humanos , Pré-Escolar , Idoso de 80 Anos ou mais , Criança , Inibidores da Angiogênese/uso terapêutico , Ranibizumab/uso terapêutico , Bevacizumab/uso terapêutico , Fator A de Crescimento do Endotélio Vascular , Fatores de Crescimento Endotelial , Estudos Retrospectivos , Injeções Intravítreas , Hemorragia Retiniana/tratamento farmacológico , Degeneração Macular/tratamento farmacológico , Endoftalmite/tratamento farmacológico , Endoftalmite/epidemiologia , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/tratamento farmacológico , Resultado do Tratamento
17.
Sensors (Basel) ; 23(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38067683

RESUMO

In this paper, a new peak average power and time reduction (PAPTR) based on the adaptive genetic algorithm (AGA) strategy is used in order to improve both the time reduction and PAPR value reduction for the SLM OFDM and the conventional genetic algorithm (GA) SLM-OFDM. The simulation results demonstrate that the recommended AGA technique reduces PAPR by about 3.87 dB in comparison to SLM-OFDM. Comparing the suggested AGA SLM-OFDM to the traditional GA SLM-OFDM using the same settings, a significant learning time reduction of roughly 95.56% is achieved. The PAPR of the proposed AGA SLM-OFDM is enhanced by around 3.87 dB in comparison to traditional OFDM. Also, the PAPR of the proposed AGA SLM-OFDM is roughly 0.12 dB worse than that of the conventional GA SLM-OFDM.

18.
J Pers Med ; 13(12)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38138855

RESUMO

Inertial measurement units (IMUs) are increasingly being used to assess knee function. The aim of the study was to record patients' activity levels and to detect new parameters for knee function in the early postoperative phase after TKA. Twenty patients (n = 20) were prospectively enrolled. Two sensors were attached to the affected leg. The data were recorded from the first day after TKA until discharge. Algorithms were developed for detecting steps, range of motion, horizontal, sitting and standing postures, as well as physical therapy. The mean number of steps increased from day 1 to discharge from 117.4 (SD ± 110.5) to 858.7 (SD ± 320.1), respectively. Patients' percentage of immobilization during daytime (6 a.m. to 8 p.m.) was 91.2% on day one and still 69.9% on the last day. Patients received daily continuous passive motion therapy (CPM) for a mean of 36.4 min (SD ± 8.2). The mean angular velocity at day 1 was 12.2 degrees per second (SD ± 4.4) and increased to 28.7 (SD ± 16.4) at discharge. This study shows that IMUs monitor patients' activity postoperatively well, and a wide range of interindividual motion patterns was observed. These sensors may allow the adjustment of physical exercise programs according to the patient's individual needs.

19.
J Pers Med ; 13(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38138865

RESUMO

BACKGROUND: The elements of previously designed questionnaires do not take into consideration the burdens encountered in an inpatient hospital setting. The purpose of this study is to validate elements of a non-compliance survey in an in-hospital setting and discuss aspects of compliance with telerehabilitative physiotherapy in the early postoperative period. METHODS: A literature search was conducted to identify elements that prevent patients from performing their prescribed physical therapy exercises. These items were then evaluated by the expert review technique as described by Ikart. Afterwards, the synthesized survey was handed out to patients for the assessment of the quality of its items. RESULTS: The results of the expert review technique identified some conceptual and grammatical problems. This led to the adjustment of some of the elements. The quality of the resulting questionnaire was deemed to be good, as patients were able to fully understand the concepts and answer accordingly. A statistical analysis was conducted to evaluate the responses. CONCLUSIONS: The items of this second questionnaire have proven to be reliable to assess the compliance of patients in an in-hospital setting. These items will be added to the cross-culturally adapted items of a previous questionnaire.

20.
J Pers Med ; 13(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37763121

RESUMO

BACKGROUND: Compliance with rehabilitative physiotherapeutic measures leads to an improvement in outcomes in patients suffering from a variety of musculoskeletal conditions. To date, a tool for assessing the parameters that lead to non-adherence to physical therapy does not exist in the German language. The objective of this paper is to cross-culturally adapt a non-compliance questionnaire to German. METHODS: In reference to the "Guidelines for the Process of Cross-Cultural Adaption of Self-Reported Measures", the questionnaire was translated into German followed by a back-translation into the original language. An expert committee met and refined the pre-final version. A preliminary version was handed out to patients for evaluation of the quality of the resulting German version. RESULTS: After the forward- and back-translation of the questionnaire, some discrepancies were discovered between the translators on the one hand and between the back-translations and the original document on the other. The statistical analysis showed satisfactory results regarding the quality of the questionnaire. CONCLUSION: The translation and adaption of the items proved to have a high degree of reliability. The German version will be made available for German-speaking researchers and used for evaluating a mobile-application-based physical therapy regimen by the authors of the paper.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA