Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Perfusion ; 38(5): 1012-1018, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35596511

RESUMO

The aortic arch plays a significant role in homeostatic mechanisms to retain blood pressure at stable balance in the cardiovascular system. Therefore, the objective is to estimate and identify cardiovascular illness imposed by the abnormal blood hemodynamic domain. In this regard, hemodynamic forces are monitored by the baroreflex of the artery wall. Therefore, these receptors quickly detect the abnormal stress magnitudes in the aortic arterial wall. The present study presents a 3D aortic arch model extracted by a Computerized tomography scan. Also, the numerical solution was carried out by ANSYS 2020 R1 in view of Fluid-Structure Interaction After that, we found wall shear stress (WSS), pressure, and velocity in the fluid domain. Also, the normal stress was analyzed to determine the aortic arch baroreflex location in the solid range. In this regard, higher WSS values are measured at the supra-aortic branches going out the aortic arch that reached 42.5 Pa. Also, higher normal stress happened at the aortic root and the supra-aortic branches and reached approximately 200 kPa at peak systole.


Assuntos
Aorta Torácica , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Pressão Sanguínea , Tomografia Computadorizada por Raios X , Modelos Teóricos , Modelos Cardiovasculares , Estresse Mecânico , Velocidade do Fluxo Sanguíneo/fisiologia
2.
Comput Methods Biomech Biomed Engin ; 26(7): 854-863, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35754388

RESUMO

Subdural hematoma (SDH) is common abnormality that is caused by the rupture of cerebral bridge veins (BVs). It occurs in more than 30% of severe head injuries. The purpose of this research was to develop a numerical model to examine the effects of brain atrophy and age on the rupture of bridging veins in subdural hematoma. Three types of models were developed to simulate subdural hematoma, namely global solid, global FSI, and local solid models. In the next step, a head impact with the head injury criterion (HIC) value of 744 was applied as a loading condition to global models. For the global solid models, we measured the relative displacement between the skull and brain. We extracted the pressure distribution from the global FSI models. The data were used as boundary conditions on the local models to evaluate the damage to the cerebral bridge veins precisely The results showed that the relative displacement was greater in the atrophied model compared to the healthy one (2.64 and 2.20 mm, respectively). In addition, the pressure value was higher in atrophied models. In the healthy local model, the maximum strain on BVs was around 1.38, while in the atrophied model, it was 2.77. The head impact, which had a HIC value of 744, did not cause serious injury to a human with a healthy brain, but it caused severe damage to an atrophied brain. The degeneration of the brain and intracranial space changes are two important factors for the movement of the brain and its vulnerability to impact.


Assuntos
Veias Cerebrais , Traumatismos Craniocerebrais , Humanos , Traumatismos Craniocerebrais/complicações , Cabeça , Hematoma Subdural/etiologia , Ruptura/complicações
3.
J Theor Biol ; 557: 111339, 2023 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-36335998

RESUMO

Multiple sclerosis (MS) is a disease of the central nervous system (CNS) that affects the brain and spinal cord. It is estimated that the average prevalence of MS is 35.9 cases per 100,000 and a total of 2.8 million people worldwide have MS. Brain atrophy is usually seen in the early stages of MS, and its progress is faster than healthy people. The present study was a numerical study that uses the Fluid-structure interaction (FSI) model to investigate the effect of brain atrophy on brain injury in MS. Firstly, a healthy model was constructed from MRI images and validated by experimental data. Then three models with different degrees of brain atrophy, which showed the rate of brain atrophy in different years in MS patients, were developed to model the brain atrophy in MS. The models were subjected to two different types of impact conditions. Type I, which only produced a translational motion and the HIC value of 744, was applied to each model. Type II produced both translational and rotational motion. In this type of impact, the experimental kinematics, with peaks of 450 g for the translational acceleration and 26.2 krad/s2 for the rotational acceleration, were applied to the nodes that located in the center of gravity of the head models and the results were extracted from each one. According to the results of impact type I, the pressure of the frontal lobe of the brain is 149,647 Pa in the health model and 137,690 Pa in the model with severe atrophy.


Assuntos
Lesões Encefálicas , Esclerose Múltipla , Doenças Neurodegenerativas , Humanos , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Atrofia , Encéfalo/diagnóstico por imagem
4.
Proc Inst Mech Eng H ; 236(9): 1449-1456, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35894299

RESUMO

Tracheal stenting is a common method which is widely used to cure different tracheal disorders including airways stenosis, chronic coughs, and accidents. In this study, we aimed to analyze the reaction of the trachea wall to exhale in three phases of light, moderate, and vigorous activities at air flows of 15 L/min (light), 26 L/min (medium), and 30 L/min (vigorous). Fluid structure interaction (FSI) was used for the numerical analysis using computed tomography (CT) images. The flow was assumed incompressible and turbulent. The stent is silicone with a Young's modulus equal to 1 MPa, Poisson's ratio 0.28, and density of 2330 kg/m3. The stent length was 60 mm and fix support boundary condition was applied for all inputs and outputs. Numerical simulation was performed using ANSYS software. The induced stresses, strains, wall deformation, flow pressure, and the flow velocity were obtained. The results showed that the stent prevented the local deformation of the wall of trachea and it reduced the induced strain in the position. But the stenting could lead to stress concentration. Finally, the stent prevented the damage to the trachea muscles during coughs in row.


Assuntos
Tosse , Traqueia , Análise de Elementos Finitos , Humanos , Reflexo , Stents , Traqueia/fisiologia , Traqueia/cirurgia
5.
Perfusion ; 37(4): 367-376, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33657934

RESUMO

BACKGROUND AND OBJECTIVES: Fluid structure interaction (FSI) is defined as interaction of the structures with contacting fluids. The aortic valve experiences the interaction with blood flow in systolic phase. In this study, we have tried to predict the hemodynamics of blood flow through a normal and stenotic aortic valve in two relaxation and exercise conditions using a three-dimensional FSI method. METHODS: The aorta valve was modeled as a three-dimensional geometry including a normal model and two others with 25% and 50% stenosis. The geometry of the aortic valve was extracted from CT images and the models were generated by MMIMCS software and then they were implemented in ANSYS software. The pulsatile flow rate was used for all cases and the numerical simulations were conducted based on a time-dependent domain. RESULTS: The obtained results including the velocity, pressure, and shear stress contours in different systolic time sequences were explained and discussed. The maximum blood flow velocity in relaxation phase was obtained 1.62 m/s (normal valve), 3.78 m/s (25% stenosed valve), and 4.73 m/s (50% stenosed valve). In exercise condition, the maximum velocities are 2.86, 4.32, and 5.42 m/s respectively. The maximum blood pressure in relaxation phase was calculated 111.45 mmHg (normal), 148.66 mmHg (25% stenosed), and 164.21 mmHg (50% stenosed). However, the calculated values in exercise situation were 129.57, 163.58, and 191.26 mmHg.The validation of the predicted results was also conducted using existing literature. CONCLUSIONS: We believe that such model are useful tools for biomechanical experts. The further studies should be done using experimental data and the data are implemented on the boundary conditions for better comparison of the results.


Assuntos
Estenose da Valva Aórtica , Modelos Cardiovasculares , Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos
6.
Comput Methods Biomech Biomed Engin ; 24(14): 1545-1551, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33749457

RESUMO

The main goal of this study was to perform a fatigue analysis and compare the results for different materials. A 72 years old patient was chosen and his hip radiographic/CT scan images were used to construct the geometry. We used four different material including Titanium, Titanium alloy, Cobalt-Chrome, and Stainless steel. The material characteristics of these prostheses were extracted from the literature. All models were exported to ANSYS software for mathematical analysis and the Von-Mises criteria, deformations, and the fatigue life were calculated for each material. Our findings showed that titanium prosthesis tolerated the lowest stress (i.e., 591 MPa for static, and 687 MPa for fatigue loading) and highest safety factor (i.e., 1.54). We found out that Titanium material could be used as the most appropriate one for the hip prosthesis due to lower stress concentration and longer life compared to other materials.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Idoso , Fadiga , Análise de Elementos Finitos , Prótese de Quadril/efeitos adversos , Humanos , Estresse Mecânico
7.
Comput Methods Biomech Biomed Engin ; 24(10): 1064-1072, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33393809

RESUMO

The locking compression plate (LCP) system has several advantages in fracture fixation combining angular stability with the use of locking screws with traditional fixation techniques. However, the system is complex and requiring careful attention to biomechanical principles and good surgical technique. Due to the set of complicate stresses and strains in the LCP system after implantation, the material, which is being used here, is deemed important. However, so far the materials have been limited to the stainless steel (SS) or titanium (Ti). This study was therefore aimed at investigate the biomechanical performance of the internal tibial locked plates at different material properties, including SS, Ti, carbon/polyether ether ketone (PEEK) composite, in treating medial tibial fracture using patient-specific finite element (FE) model of the human tibia. The carbon/PEEK composite materials were used at three different fiber plies configurations. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect. The model was fixed distally in all degrees of freedom. The results revealed the highest stress (307.10 MPa) and the lowest strain (0.14%) at Ti LCP system. The carbon/PEEK LCP system at configuration I and III showed low stress (∼60 MPa) and high strain (0.70%), which are suitable points for designing of an internal LCP system. On the other hand, the highest value of stress in callus region was 4.78 MPa (Carbon PEEK/Configuration I) and the strain variations of callus region were between 1.46% and 3.82% among all materials. These results implied the advantage of carbon/PEEK composite materials in LCP system as they can tolerate higher strains at lower stresses.


Assuntos
Fraturas da Tíbia , Fenômenos Biomecânicos , Placas Ósseas , Análise de Elementos Finitos , Fixação Interna de Fraturas , Humanos , Tíbia , Fraturas da Tíbia/cirurgia
8.
Comput Methods Programs Biomed ; 183: 105109, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31606558

RESUMO

BACKGROUND AND OBJECTIVE: The knee joint is a complex structure which is vulnerable to injury due to various types of loadings as a consequence of walking, running, stair climbing, etc. Total knee arthroplasty (TKA) is a widely used and successful orthopedic procedure which during that the posterior cruciate ligament (PCL) can either be retained or substituted. Different surgical techniques suggest retention or sacrifice of the PCL in TKA for the treatment of osteoarthritis which may alter the post-op outcomes. The objective of this study was to evaluate the biomechanical role of PCL after TKA surgery using finite element (FE) modeling. METHODS: A three-dimensional (3D) FE model of the prosthetic knee was developed and its validity was compared to available studies in literature. Further, the effect of the retention or removing of the PCL as well as its degradation (i.e. variation in mechanical properties) and angle on knee biomechanics were evaluated during a weight-bearing squatting movement. RESULTS: The validity of the intact model were confirmed. The results revealed higher stresses in the PCL and tibial insert at higher femoral flexion angles. In addition, the effect of variations in the stiffness of the PCL was found to be negligible at lower while considerable at higher femoral flexion angles. The variations in the elevation angle of the PCL from 89° to 83° at the critical femoral angles of 60° and 120° showed the highest von Mises stresses in the tibial insert. CONCLUSIONS: The results have implications not only for understanding the stresses in the prosthetic knee model under squat movement but also for providing comprehensive information about the effects of variations in the PCL stiffness and balancing on the induced stresses of the PCL and tibial insert.


Assuntos
Artroplastia do Joelho , Análise de Elementos Finitos , Ligamento Cruzado Posterior/fisiopatologia , Algoritmos , Fenômenos Biomecânicos , Fêmur/fisiologia , Humanos , Imageamento Tridimensional , Articulação do Joelho , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Amplitude de Movimento Articular , Estresse Mecânico , Suporte de Carga
9.
Comput Methods Programs Biomed ; 177: 203-209, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31319949

RESUMO

BACKGROUND AND OBJECTIVE: Sneezing is one of the most critical conditions that can occur in the human upper airway. As some reports confirm the injury to the human upper respiratory airway while sneezing. Therefore, the accurate study of the distribution of pressure and velocity in this case is of great importance. METHODS: In the present study, using a real human upper airway model, the pressure and velocity of the airflow generated in the tract during the sneezing have been investigated. Also, considering the results from a spirometer device as a boundary condition in the simulation process, the calculations have become reliable. RESULTS: According to the results, during sneezing, taking into account that the average outlet flow rate from the mouth is 4.79 L/s, the velocity of outlet airflow from the mouth and nose reaches 5.3 and 8.4 m/s, respectively. These values were 11.5 and 19, respectively, when the desired maximum flow rate was 10.58 L/s. It can be concluded that the increasing of trachea flow rate, leads to higher percentage of the outlet flow rate from the nose . The highest average pressure and velocity have been occurred in the trachea. Among other salient results of this report, increased average static pressure of larynx to approximately 10 kPa can be pointed which indicates that this area is critical so that the thyroid cartilage defect is likely to occur. It is also noteworthy that the increase of speed at nasopharynx is up to 125 m/s so that the cross-section changing in this area leads the fluid acts as a jet flow. Due to the specific geometry of the nasal cavity, some streams similar to poor shocks are formed, these shocks get stronger by increasing of the flow rate. The thyroid cartilage and nasal cavity are exposed to maximum static pressure extremums, respectively. CONCLUSIONS: We introduced a model simulating a normal sneezing for two cases using a healthy 30-year-old male person. We believe that the model should be applied for different persons and an atlas of data could be obtained from different cases. This may help the medical system to have more data about the sneezing process.


Assuntos
Nasofaringe/fisiologia , Respiração , Mecânica Respiratória , Espirro , Traqueia/fisiologia , Adulto , Algoritmos , Simulação por Computador , Humanos , Hidrodinâmica , Imageamento Tridimensional , Masculino , Modelos Anatômicos , Cavidade Nasal/diagnóstico por imagem , Cavidade Nasal/fisiologia , Nasofaringe/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Traqueia/diagnóstico por imagem
10.
Comput Methods Biomech Biomed Engin ; 22(3): 288-303, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30596526

RESUMO

The aim of this study is to simulate the Mitral Regurgitation (MR) disease progression from mild to severe intensity. A Fluid Structure Interaction (FSI) model was developed to extract the hemodynamic parameters of blood flow in mitral regurgitation (MR) during systole. A two-dimensional (2D) geometry of the mitral valve was built based on the data resulting from Magnetic Resonance Imaging (MRI) dimensional measurements. The leaflets were assumed to be elastic. Using COMSOL software, the hemodynamic parameters of blood flow including velocity, pressure, and Von Mises stress contours were obtained by moving arbitrary Lagrange-Euler mesh. The results were obtained for normal and MR cases. They showed the effects of the abnormal distance between the leaflets on the amount of returned flow. Furthermore, the deformation of the leaflets was measured during systole. The results were found to be consistent with the relevant literature.


Assuntos
Circulação Coronária , Hemodinâmica/fisiologia , Hemorreologia , Insuficiência da Valva Mitral/fisiopatologia , Velocidade do Fluxo Sanguíneo , Humanos , Masculino , Valva Mitral/fisiopatologia , Modelos Cardiovasculares , Pressão , Estresse Mecânico , Sístole/fisiologia , Adulto Jovem
11.
Artif Organs ; 43(4): 424-434, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30230562

RESUMO

Fluoroscopy-guided placement of pedicle screws is usually used to position pedicle screws, although it is highly risky due to lack of accuracy during operation and surgeon's intensive labor requirement during surgery. In this study, a new method was introduced to consider the issues and we tried to reduce the risk of pedicle screw placement and drilling process. To put pedicle screws in the correct position and orientation, a specific drill guide is designed and fabricated by additive manufacturing technology. In addition, since the drilling process is remarkably important and it is usually dependent on surgeon skill, therefore a teleoperation system is proposed to perform this task. In order to let the surgeon to have better control on the patient, a control scheme including position and velocity signals along with surgeon force and reaction force of vertebra was proposed. This helped the surgeon for proper control on the patient during surgery. A force estimation algorithm was presented to eliminate measuring external force signal. Consequently, 10 vertebras were used to evaluate specific drill guide and teleoperation system simultaneously. Then, the computed tomography evaluation demonstrated that Kirschner wire trajectories followed the planned axes with an error between 1 and 2 mm in 20% of cases and less than 1 mm in 80% of cases. The results obtained by the teleoperation system showed that the surgeon, in the master side, has proper control over the patient body in the slave side because the slave robot followed the master position. Furthermore, the surgeon in the master side sensed the reaction force of vertebra in the slave side appropriately.


Assuntos
Fluoroscopia/métodos , Parafusos Pediculares , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Algoritmos , Humanos , Parafusos Pediculares/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Software , Telemedicina/métodos , Tomografia Computadorizada por Raios X/métodos
12.
Perfusion ; 34(3): 225-230, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30394849

RESUMO

OBJECT: Mitral regurgitation (MR) is a condition in which the mitral valve does not prevent the reversal of blood flow from the left ventricle into the left atrium. This study aimed at numerically developing a model to mimic MR and poor leaflet coaptation and also comparing the performance of a normal mitral valve to that of the MR conditions at different gap junctions of 1, 3 and 5 mm between the anterior and posterior leaflets. RESULTS: The results revealed no blood flow to the left ventricle when a gap between the leaflets was 0 mm. However, MR increased this blood flow, with increases in the velocity and pressure within the atrium. However, the pressure within the aorta did not vary meaningfully (ranging from 22 kPa for a 'healthy' model to 25 kPa for severe MR). CONCLUSIONS: The findings from this study have implications not only for understanding the changes in pressure and velocity as a result of MR in the ventricle, atrium or aorta, but also for the development of a computational model suitable for clinical translation when diagnosing and determining treatment for MR.


Assuntos
Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Ventrículos do Coração/patologia , Hemodinâmica , Humanos , Valva Mitral/patologia , Insuficiência da Valva Mitral/patologia , Modelos Cardiovasculares , Sístole
13.
Clin Sci (Lond) ; 132(24): 2599-2607, 2018 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-30420584

RESUMO

The need for simple and reliable means of respiratory monitoring has existed since the beginnings of medicine. In the present study, we describe the use of color spectrographic analysis of breathing sounds recorded from the external ear canal as a candidate technology to meet this need. A miniature electret microphone was modified with the addition of an adapter to allow it to be placed comfortably in the external ear canal. The amplified signal was then connected to a real-time color spectrogram program running on a laptop personal computer utilizing the Windows operating system. Based on the results obtained, we hypothesize that the real-time display of color spectrogram breathing patterns locally or at a central monitoring station may turn out to be a useful means of respiratory monitoring in patients at increased risk of respiratory depression or other respiratory problems. Finally, we conducted a statistical analysis that suggests that significant spectrogram differences may exist among some groups investigated in the study.


Assuntos
Acústica , Doenças Cardiovasculares/diagnóstico , Meato Acústico Externo/anatomia & histologia , Pneumopatias/diagnóstico , Pulmão/fisiopatologia , Respiração , Sons Respiratórios , Acústica/instrumentação , Adolescente , Adulto , Idoso , Amplificadores Eletrônicos , Doenças Cardiovasculares/fisiopatologia , Estudos de Casos e Controles , Desenho de Equipamento , Feminino , Humanos , Pneumopatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Miniaturização , Valor Preditivo dos Testes , Dados Preliminares , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Fatores de Tempo , Adulto Jovem
14.
Biomed Eng Online ; 16(1): 130, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29137676

RESUMO

BACKGROUND: Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. METHODS: In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. RESULTS: The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. CONCLUSIONS: The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.


Assuntos
Modelagem Computacional Específica para o Paciente , Parafusos Pediculares , Escoliose/cirurgia , Adolescente , Criança , Feminino , Humanos , Masculino , Modelos Anatômicos , Impressão Tridimensional , Escoliose/diagnóstico por imagem , Escoliose/patologia , Tomografia Computadorizada por Raios X , Adulto Jovem
15.
Proc Inst Mech Eng H ; 231(2): 143-148, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28233504

RESUMO

Free-hand pedicle screw placement is still conventional in surgery, although it has potentially high risks. The surgical procedures such as pedicle screw placement are usually designed based on medical imaging, but during surgery, the procedures are not normally followed due to the fact that some points are missed in two-dimensional images and seen only during surgery. In this regards, some highly accurate computer-assisted systems have been proposed and are currently used. Moreover, it is possible to reduce or completely avoid hand working by applying modern digital technology. Therefore, using these technologies has remarkable advantages. In this study, we have presented a new approach of pedicle screw placement in the lumbar and sacral regions using a specific drill guide template. The template was created by additive manufacturing technology and was verified in a clinical study as well. The main aim of this research includes the following: design, analyze, manufacture and evaluate the accuracy of a new patient-specific drill guide template, for lumbar pedicle screw placement, and compare the template to the free-hand technique under fluoroscopy supervision. Our results show that the incidence of cortex perforation is substantially reduced compared to existing methods. Finally, we believe that this approach remarkably lowers the incidence of cortex perforation and could be potentially used in clinical applications, particularly in certain selected cases.


Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Fenômenos Biomecânicos , Fluoroscopia , Humanos , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Sacro/cirurgia , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
16.
J Clin Monit Comput ; 31(3): 607-616, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27142100

RESUMO

Central venous pressure (CVP) is an important clinical parameter for physicians but only the absolute CVP value is typically monitored in the intensive care unit (ICU). In this study, we propose a novel mathematical method to present and analyze CVP signals. A total of 44 suitable samples were chosen from a total of 65 collected in an ICU. Pre-processing of the samples included rate reduction and digital filtering. The statistical features of time and frequency domain, wavelet, and empirical mode decomposition of these signals were extracted. We found no significant difference among the CVP signals regarding sex, smoking, coronary disease, and respiration mode of the samples.


Assuntos
Algoritmos , Determinação da Pressão Arterial/métodos , Pressão Venosa Central , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Diagnóstico por Computador/métodos , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Biosci Rep ; 36(5)2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27512094

RESUMO

Abortion of the fetus due to a disease, in an early stage of pregnancy, has been dramatically increased in the last decades. There is a still lack of knowledge on the various types of diseases which lead fetus to a vulnerable circumstance. The transport of oxygenated blood from the placenta to the human fetus has been an important clinical feature in Doppler velocimetry studies, especially the ductus venosus (DV). The DV connects intra-abdominal portion of the umbilical vein and the inferior vena cava (IVC) at the inlet of the right atrium and is, therefore, important when examining the fetus state of health. An abnormal flow in the DV can indicate a fetal disease such as, chromosomal abnormalities, cardiac defect, hypoxaemia and intrauterine growth restriction (IUGR). The blood flow in the fetal circulation has not been investigated much in detail. The blood flow in the fetal circulation provides necessary information for physician to make a suitable decision on abortion or alternative medical practice before or even after birth. The present study performed a comparative study to quantify the blood velocity in DV by a combination approach based on 3D computational simulation and Doppler measurement. The results showed that the velocity value in DV is significant and can be considered as an indicator of any kind of disease in fetal. The nodal displacement of the model was also analysed. It shows that DV tolerates a higher level of displacement compared with the other regions of the model, whereas the nodal pressure shows different results as the lowest values are located in DV.

18.
J Clin Monit Comput ; 30(1): 107-18, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25869899

RESUMO

This study pertains to a six-channel acoustic monitoring system for use in patient monitoring during or after surgery. The base hardware consists of a USB data acquisition system, a custom-built six-channel amplification system, and a series of microphones of various designs. The software is based on the MATLAB platform with data acquisition drivers installed. The displayed information includes: time domain signals, frequency domain signals, and tools to aid in the detection of endobronchial intubation. We hypothesize that the above mentioned arrangement may be helpful to the anesthesiologist in recognizing clinical conditions like wheezing, bronchospasm, endobronchial intubation, and apnea. The study also evaluated various types of microphone designs used to transduce breath sounds. The system also features selectable band-pass filtering using MATLAB algorithms as well as a collection of recordings obtained with the system to establish what respiratory acoustic signals look like under various conditions.


Assuntos
Diagnóstico por Computador/instrumentação , Auscultação Cardíaca/instrumentação , Monitorização Intraoperatória/instrumentação , Assistência Perioperatória/instrumentação , Testes de Função Respiratória/instrumentação , Interface Usuário-Computador , Acústica , Adulto , Idoso , Idoso de 80 Anos ou mais , Apresentação de Dados , Estudos de Viabilidade , Feminino , Auscultação Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Assistência Perioperatória/métodos , Projetos Piloto , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos , Sensibilidade e Especificidade , Espectrografia do Som/instrumentação , Espectrografia do Som/métodos
19.
Australas Phys Eng Sci Med ; 38(4): 569-80, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26462678

RESUMO

Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.


Assuntos
Materiais Biocompatíveis/química , Carbono/química , Prótese de Quadril , Cetonas/química , Polietilenoglicóis/química , Aço Inoxidável/química , Titânio/química , Benzofenonas , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Polímeros , Desenho de Prótese , Estresse Mecânico
20.
Comput Methods Biomech Biomed Engin ; 18(13): 1418-26, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24773299

RESUMO

Coronary artery disease is responsible for almost 30% of all deaths worldwide. The saphenous vein and umbilical vein (UV) are the most common veins using for treatment as a coronary artery bypass graft (CABG). The mechanical properties of UV belonging to its long-term patency for CABG are very important. However, there is a lack of knowledge on the linear elastic and nonlinear hyperelastic mechanical properties of the UV. In this study, three stress definitions (second Piola-Kichhoff stress, engineering stress and true stress) and four strain definitions (Almansi-Hamel strain, Green-St Venant strain, engineering strain and true strain) are used to determine the elastic modulus, maximum stress and strain of eight human UVs under circumferential loading. The nonlinear mechanical behaviour of the UV is computationally investigated using Mooney-Rivlin hyperelastic model. A numerical finite element analysis is also carried out to simulate the constitutive modelling versus its numerical results. The results show that the Almansi-Hamel strain definition overestimates the elastic modulus while Green-St Venant strain definition underestimates the elastic modulus at different stress definitions. The true stress-true strain definition, which gives more accurate measurements of the tissue's response using the instantaneous values, reveals the Young's modulus and maximum stress of 2.18 and 6.01 MPa, respectively. The Mooney-Rivlin material model is well represented by the nonlinear mechanical behaviour of the UV. The findings of this study could have implications not only for understanding the extension and rupture mechanism of UV but also for interventions and surgeries, including balloon angioplasty, bypass and stenting.


Assuntos
Estresse Mecânico , Veias Umbilicais/fisiologia , Ponte de Artéria Coronária , Módulo de Elasticidade/fisiologia , Elasticidade , Análise de Elementos Finitos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA