Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
SAGE Open Med ; 6: 2050312118794591, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30891243

RESUMO

OBJECTIVE: Our main objective was to evaluate the short- and long-term efficacy of Celon radiofrequency-induced thermal therapy for endovenous treatment of incompetent great saphenous vein. The secondary objectives were to report on possible short-term side effects and complications. METHODS: This was a retrospective study of 112 consecutive patients included between 2013 and June 2015. These patients were treated (146 great saphenous vein, C2-C6) either at the hemodynamic room using local anesthesia or at the operating theater under general anesthesia with or without phlebectomy. All patients received radiofrequency-induced thermal therapy at 18 W power, 1 s/cm pullback rate and 5-7 pullbacks per segment of 10 cm (i.e. maximum 10 pullbacks). A clinical follow-up via ultrasound monitoring was done at 1 week, 1 month, 6 months, 1 year, 2 years and 3 years. RESULTS: The 3-year survival occlusion rate was 96.71% and 98% for overall and radiofrequency-induced thermal therapy patients, respectively. No major side effects were observed. A case of endovenous heat-induced thrombosis was reported. Slight neurological disorders were reported (0.88%). CONCLUSION: Our unit's endovenous Celon radiofrequency-induced thermal therapy of incompetent great saphenous vein was efficient, well tolerated, without major side effects. Moreover, in order to reduce possible neurological disorders, we advise multiple pullbacks at 1 s/cm and using tumescence anesthesia.

2.
J Chromatogr A ; 1383: 127-33, 2015 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-25622518

RESUMO

The preparation conditions of silica monoliths for gas chromatography were investigated. Silica-based monolithic capillary columns based on sol-gel process were tested in the course of high-speed gas chromatographic separations of light hydrocarbons mixture (C1-C4). The impact of modifying the amount of porogen and/or catalyst on the monolith properties were studied. At the best precursor/catalyst/porogen ratio evaluated, a column efficiency of about 6500 theoretical plates per meter was reached with a very good resolution (4.3) for very light compounds (C1-C2). The test mixture was baseline separated on a 70cm column. To our knowledge for the first time a silica-based monolithic capillary column was able to separate light hydrocarbons from methane to n-butane at room temperature with a back pressure in the range of gas chromatography facilities (under 4.1bar).


Assuntos
Cromatografia Gasosa , Hidrocarbonetos/isolamento & purificação , Dióxido de Silício/química , Cromatografia Gasosa/instrumentação , Géis/química , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA