Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 59(3): 1010-1020, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37259967

RESUMO

BACKGROUND: 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is valuable for determining presence of viable tumor, but is limited by geographical restrictions, radiation exposure, and high cost. PURPOSE: To generate diagnostic-quality PET equivalent imaging for patients with brain neoplasms by deep learning with multi-contrast MRI. STUDY TYPE: Retrospective. SUBJECTS: Patients (59 studies from 51 subjects; age 56 ± 13 years; 29 males) who underwent 18 F-FDG PET and MRI for determining recurrent brain tumor. FIELD STRENGTH/SEQUENCE: 3T; 3D GRE T1, 3D GRE T1c, 3D FSE T2-FLAIR, and 3D FSE ASL, 18 F-FDG PET imaging. ASSESSMENT: Convolutional neural networks were trained using four MRIs as inputs and acquired FDG PET images as output. The agreement between the acquired and synthesized PET was evaluated by quality metrics and Bland-Altman plots for standardized uptake value ratio. Three physicians scored image quality on a 5-point scale, with score ≥3 as high-quality. They assessed the lesions on a 5-point scale, which was binarized to analyze diagnostic consistency of the synthesized PET compared to the acquired PET. STATISTICAL TESTS: The agreement in ratings between the acquired and synthesized PET were tested with Gwet's AC and exact Bowker test of symmetry. Agreement of the readers was assessed by Gwet's AC. P = 0.05 was used as the cutoff for statistical significance. RESULTS: The synthesized PET visually resembled the acquired PET and showed significant improvement in quality metrics (+21.7% on PSNR, +22.2% on SSIM, -31.8% on RSME) compared with ASL. A total of 49.7% of the synthesized PET were considered as high-quality compared to 73.4% of the acquired PET which was statistically significant, but with distinct variability between readers. For the positive/negative lesion assessment, the synthesized PET had an accuracy of 87% but had a tendency to overcall. CONCLUSION: The proposed deep learning model has the potential of synthesizing diagnostic quality FDG PET images without the use of radiotracers. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fluordesoxiglucose F18 , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos
2.
Radiol Artif Intell ; 5(3): e220246, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37293349

RESUMO

Purpose: To develop a deep learning approach that enables ultra-low-dose, 1% of the standard clinical dosage (3 MBq/kg), ultrafast whole-body PET reconstruction in cancer imaging. Materials and Methods: In this Health Insurance Portability and Accountability Act-compliant study, serial fluorine 18-labeled fluorodeoxyglucose PET/MRI scans of pediatric patients with lymphoma were retrospectively collected from two cross-continental medical centers between July 2015 and March 2020. Global similarity between baseline and follow-up scans was used to develop Masked-LMCTrans, a longitudinal multimodality coattentional convolutional neural network (CNN) transformer that provides interaction and joint reasoning between serial PET/MRI scans from the same patient. Image quality of the reconstructed ultra-low-dose PET was evaluated in comparison with a simulated standard 1% PET image. The performance of Masked-LMCTrans was compared with that of CNNs with pure convolution operations (classic U-Net family), and the effect of different CNN encoders on feature representation was assessed. Statistical differences in the structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), and visual information fidelity (VIF) were assessed by two-sample testing with the Wilcoxon signed rank t test. Results: The study included 21 patients (mean age, 15 years ± 7 [SD]; 12 female) in the primary cohort and 10 patients (mean age, 13 years ± 4; six female) in the external test cohort. Masked-LMCTrans-reconstructed follow-up PET images demonstrated significantly less noise and more detailed structure compared with simulated 1% extremely ultra-low-dose PET images. SSIM, PSNR, and VIF were significantly higher for Masked-LMCTrans-reconstructed PET (P < .001), with improvements of 15.8%, 23.4%, and 186%, respectively. Conclusion: Masked-LMCTrans achieved high image quality reconstruction of 1% low-dose whole-body PET images.Keywords: Pediatrics, PET, Convolutional Neural Network (CNN), Dose Reduction Supplemental material is available for this article. © RSNA, 2023.

3.
Eur J Nucl Med Mol Imaging ; 50(6): 1689-1698, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36717409

RESUMO

PURPOSE: To assess and compare the diagnostic accuracy of whole-body (WB) DW-MRI with 2-[18F]FDG PET for staging and treatment monitoring of children with Langerhans cell histiocytosis (LCH). METHODS: Twenty-three children with LCH underwent 2-[18F]FDG PET and WB DW-MRI at baseline. Two nuclear medicine physicians and two radiologists independently assessed presence/absence of tumors in 8 anatomical areas. Sixteen children also performed 2-[18F]FDG PET and WB DW-MRI at follow-up. One radiologist and one nuclear medicine physician revised follow-up scans and collected changes in tumor apparent diffusion (ADC) and standardized uptake values (SUV) before and after therapy in all detectable lesions. 2-[18F]FDG PET results were considered the standard of reference for tumor detection and evaluation of treatment response according to Lugano criteria. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of WB DW-MRI at baseline were calculated, and the 95% confidence intervals were estimated by using the Clopper-Pearson (exact) method; changes in tumor SUVs and ADC were compared using a Mann-Whitney U test. Agreement between reviewers was assessed with a Cohen's weighted kappa coefficient. Analyses were conducted using SAS software version 9.4. RESULTS: Agreement between reviewers was perfect (kappa coefficient = 1) for all analyzed regions but spine and neck (kappa coefficient = 0.89 and 0.83, respectively) for 2-[18F]FDG PET images, and abdomen and pelvis (kappa coefficient = 0.65 and 0.88, respectively) for WB DW-MRI. Sensitivity and specificity were 95.5% and 100% for WB DW-MRI compared to 2-[18F]FDG PET. Pre to post-treatment changes in SUVratio and ADCmean were inversely correlated for all lesions (r: -0.27, p = 0·06) and significantly different between responders and non-responders to chemotherapy (p = 0.0006 and p = 0·003 for SUVratio and ADCmean, respectively). CONCLUSION: Our study showed that WB DW-MRI has similar accuracy to 2-[18F]FDG PET for staging and treatment monitoring of LCH in children. While 2-[18F]FDG PET remains an approved radiological examination for assessing metabolically active disease, WB DW-MRI could be considered as an alternative approach without radiation exposure. The combination of both modalities might have advantages over either approach alone.


Assuntos
Histiocitose de Células de Langerhans , Neoplasias , Humanos , Criança , Fluordesoxiglucose F18 , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Compostos Radiofarmacêuticos , Imagem Corporal Total/métodos , Histiocitose de Células de Langerhans/diagnóstico por imagem , Histiocitose de Células de Langerhans/terapia , Tomografia por Emissão de Pósitrons/métodos , Estadiamento de Neoplasias
4.
Pediatr Radiol ; 52(2): 391-400, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33929564

RESUMO

Accurate staging and re-staging of cancer in children is crucial for patient management. Currently, children with a newly diagnosed cancer must undergo a series of imaging tests, which are stressful, time-consuming, partially redundant, expensive, and can require repetitive anesthesia. New approaches for pediatric cancer staging can evaluate the primary tumor and metastases in a single session. However, traditional one-stop imaging tests, such as CT and positron emission tomography (PET)/CT, are associated with considerable radiation exposure. This is particularly concerning for children because they are more sensitive to ionizing radiation than adults and they live long enough to experience secondary cancers later in life. In this review article we discuss child-tailored imaging tests for tumor detection and therapy response assessment - tests that can be obtained with substantially reduced radiation exposure compared to traditional CT and PET/CT scans. This includes diffusion-weighted imaging (DWI)/MRI and integrated [F-18]2-fluoro-2-deoxyglucose (18F-FDG) PET/MRI scans. While several investigators have compared the value of DWI/MRI and 18F-FDG PET/MRI for staging pediatric cancer, the value of these novel imaging technologies for cancer therapy monitoring has received surprisingly little attention. In this article, we share our experiences and review existing literature on this subject.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Criança , Imagem de Difusão por Ressonância Magnética , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA