1.
Injury ; 51(8): 1840-1845, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32540179

RESUMO

INTRODUCTION: Lag screw insertion into the ideal position is essential to obtain good results in open reduction and internal fixation for femoral trochanteric fracture. Tip-apex distance (TAD) is a widely adopted method for evaluating the risk of lag screw cut-out. Adaptive positioning technology (ADAPT) is a fluoroscopic computer-assisted surgery system that enables orthopaedic surgeons to guide the screw into a proper position intraoperatively. A randomized control study concluded that ADAPT resulted in excellent TAD. However, it was not significantly better than conventional methods when performed by fellowship-trained traumatologists. Therefore, we hypothesised that ADAPT would be useful to orthopaedic residents and evaluated this usefulness. METHODS: We reviewed 102 patients who underwent open reduction and internal fixation for femoral trochanteric fracture from May 2017 to March 2019 using Gamma-3 intertrochanteric nails. Two residents performed all procedures; 51 patients underwent surgery using ADAPT and the others underwent surgery without navigation. The number of attempts to drill guide-wire, operation time, lag screw insertion time, radiation exposure time, TAD, and lag screw position were evaluated for each surgeon. RESULTS: In one resident, when using the ADAPT system, the number of attempts to drill guide-wire (p=0.001), lag screw insertion time (p=0.000), radiational exposure time (p=0.009) and TAD (p=0.007) were lower, and the percentage of ideal lag screw position (p=0.035) were better than that in the conventional method. However, there was no significant difference in the performance of another resident with respect to the aforementioned factors, whether using ADAPT or not. CONCLUSION: One resident showed better results with the ADAPT system than with conventional osteosynthesis. However, another resident received no benefit from ADAPT. The efficiency may not apply to everyone as individual competence can influence efficiency when using ADAPT system. Therefore, as a new device, it must be used cautiously because skill or experience may influence its use, especially by orthopaedic residents.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Ortopedia , Parafusos Ósseos , Fluoroscopia , Fixação Interna de Fraturas , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos
2.
Injury ; 49(6): 1149-1154, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29605293

RESUMO

PURPOSE: ADAPT is a fluoroscopic computer-assisted surgery system which intraoperatively shows the distance from the tip of the screw to the surface of the femoral head, tip-to-head-surface distance (TSD), and the tip-apex distance (TAD) advocated by Baumgaertner et al. The study evaluated the accuracy of ADAPT. PATIENTS AND METHODS: A total of 55 patients operated with ADAPT between August 2016 and March 2017 were included as subjects. TSD and TAD were measured postoperatively using computed tomography (CT) and X-rays. The intraclass correlation coefficient (ICC) was checked in advance. The error was defined as the difference between postoperative and intraoperative measurement values of ADAPT. Summary statistics, root mean square errors (RMSEs), and correlations were evaluated. RESULTS: ICC was 0.94 [95% CI: 0.90-0.96] in TSD and 0.99 [95% CI: 0.98-0.99] in TAD. The error was -0.35 mm (-1.83 mm to 1.12 mm) in TSD and +0.63 mm (-5.65 mm to 4.59 mm) in TAD. RMSE was 0.63 mm in TSD and 1.53 mm in TAD. Pearson's correlation coefficient was 0.79 [95% CI: 0.66-0.87] in TSD and 0.83 [95% CI: 0.72-0.89] in TAD. There were no adverse events with ADAPT use. CONCLUSION: ADAPT is highly accurate and useful in guiding surgeons in properly positioning the screws.


Assuntos
Fraturas do Fêmur/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Fluoroscopia , Fixação Intramedular de Fraturas/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Parafusos Ósseos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/anatomia & histologia , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X , Resultado do Tratamento