RESUMO
Background: To prevent hypoxic-ischemic brain damage in patients with post-cardiac arrest syndrome (PCAS), international guidelines have emphasized performing targeted temperature management (TTM). However, the most optimal targeted core temperature and cooling duration reached no consensus to date. This study aimed to clarify the optimal targeted core temperature and cooling duration, selected according to the time interval from collapse to return of spontaneous circulation (ROSC) in patients with PCAS due to cardiac etiology. Methods: Between 2014 and 2020, the targeted core temperature was 34 °C or 35 °C, and the cooling duration was 24 h. If the time interval from collapse to ROSC was within 20 min, we performed the 35 °C targeted core temperature (Group A), and, if not, we performed the 34 °C targeted core temperature (Group B). Between 2009 and 2013, the targeted core temperature was 34 °C, and the cooling duration was 24 or 48 h. If the interval was within 20 min, we performed the 24 h cooling duration (Group C), and, if not, we performed the 48 h cooling duration (Group D). Results: The favorable neurological outcome rates at 30 days following cardiac arrest were 45.7% and 45.5% in Groups A + B and C + D, respectively (p = 0.977). In patients with ROSC within 20 min, the favorable neurological outcome rates at 30 days following cardiac arrest were 75.6% and 86.4% in Groups A and C, respectively (p = 0.315). In patients with ROSC ≥ 21 min, the favorable neurological outcome rates at 30 days following cardiac arrest were 29.3% and 18.2% in Groups B and D, respectively (p = 0.233). Conclusions: Selecting the optimal target core temperature and the cooling duration for TTM, according to the time interval from collapse to ROSC, may be helpful in patients with PCAS due to cardiac etiology.
Assuntos
Hipotermia Induzida , Síndrome Pós-Parada Cardíaca , Humanos , Hipotermia Induzida/métodos , Hipotermia Induzida/normas , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Síndrome Pós-Parada Cardíaca/complicações , Síndrome Pós-Parada Cardíaca/fisiopatologia , Fatores de Tempo , Temperatura Corporal , Estudos Retrospectivos , Parada Cardíaca/terapia , Parada Cardíaca/complicaçõesRESUMO
BACKGROUND: Identification of infrequent nonpulmonary vein trigger premature atrial contractions (PACs) is challenging. We hypothesized that pace mapping (PM) assessed by correlation scores calculated by an intracardiac pattern matching (ICPM) module was useful for locating PAC origins, and conducted a validation study to assess the accuracy of ICPM-guided PM. METHODS: Analyzed were 30 patients with atrial fibrillation. After pulmonary vein isolation, atrial pacing was performed at one or two of four sites on the anterior and posterior aspects of the left atrium (LA, n = 10/10), LA septum (n = 10), and lateral RA (n = 10), which was arbitrarily determined as PAC. The intracardiac activation obtained from each pacing was set as an ICPM reference consisting of six CS unipolar electrograms (CS group) or six CS unipolar electrograms and four RA electrograms (CS-RA group). RESULTS: The PM was performed at 193 ± 107 sites for each reference pacing site. All reference pacing sites corresponded to sites where the maximal ICPM correlation score was obtained. Sites with a correlation score ≥98% were rarely obtained in the CS-RA than CS group (33% vs. 55%, P = .04), but those ≥95% were similarly obtained between the two groups (93% vs. 88%, P = .71), and those ≥90% were obtained in all. The surface areas with correlation scores ≥98% (0[0,10] vs. 10[0,35] mm2, P = .02), ≥95% (10[10,30] vs. 50[10,180] mm2, P = .002) and ≥90% (60[30,100] vs. 170[100,560] mm2, P = .0002) were smaller in the CS-RA than CS group. CONCLUSIONS: ICPM-guided PM was useful for identifying the reference pacing sites. Combined use of RA and CS electrograms may improve the mapping quality.
Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Veias Pulmonares/fisiopatologia , Idoso , Mapeamento Potencial de Superfície Corporal/métodos , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Técnicas Eletrofisiológicas Cardíacas/métodos , Sensibilidade e Especificidade , Átrios do Coração/fisiopatologiaRESUMO
Background: Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often withheld especially in Japanese heart failure patients with reduced left ventricular ejection fraction (HFrEF) who have not experienced ventricular tachycardia (VT) or ventricular fibrillation (VF) for uncertain reasons. Recent advancements in heart failure (HF) medications have significantly improved the prognosis for HFrEF. Given this context, a critical reassessment of the treatment and prognosis of ICDs and WCDs is essential, as it has the potential to reshape awareness and treatment strategies for these patients. Methods: We are initiating a prospective multicenter observational study for HFrEF patients eligible for ICD in primary and secondary prevention, and WCD, regardless of device use, including all consenting patients. Study subjects are to be enrolled from 31 participant hospitals located throughout Japan from April 1, 2023, to December 31, 2024, and each will be followed up for 1 year or more. The planned sample size is 651 cases. The primary endpoint is the rate of cardiac implantable electronic device implementation. Other endpoints include the incidence of VT/VF and sudden death, all-cause mortality, and HF hospitalization, other events. We will collect clinical background information plus each patient's symptoms, Clinical Frailty Scale score, laboratory test results, echocardiographic and electrocardiographic parameters, and serial changes will also be secondary endpoints. Results: Not applicable. Conclusion: This study offers invaluable insights into understanding the role of ICD/WCD in Japanese HF patients in the new era of HF medication.
RESUMO
Background: The effects of the patient's disease awareness on the management of postablation of atrial fibrillation (AF) are unknown. Methods: One hundred thirty-three AF patients undergoing an initial ablation were given a disease awareness questionnaire with a score of 16 points (8 points about AF in general and 8 points about oral anticoagulants) for the Jessa Atrial Fibrillation Knowledge Questionnaire (JAKQ) before and 1-year-after ablation. We divided them into the poor disease awareness group and good disease awareness group according to the median value (75%) of the total JAKQ score about AF in general, and compared the baseline patient characteristics and the 1-year changes in the JAKQ score, medication adherence, blood pressure, laboratory data, echocardiographic parameters, and AF/atrial tachycardia (AT) recurrence rate between the two groups. Results: Forty-two (31.6%) patients were classified as having poor disease awareness (<75% of the total JAKQ score), which was closely associated with poor medication adherence, hypertension, diabetes, dyslipidemia, and greater left atrial volume (LAV). These trends in the poor disease awareness group remained unchanged 1 year after the ablation. During the 25.3-month follow-up, the AF/AT recurrence rate was significantly higher in the poor disease awareness than the good disease awareness group (23.8% vs. 7.7%; p = .003 by the log-rank test). Conclusions: Poor disease awareness was linked to poor medication adherence, lifestyle-related diseases, and greater LAV before and even 1 year after the ablation, making it a potential surrogate marker for AF/AT recurrence. These findings highlight the clinical significance of disease awareness in AF management.
RESUMO
INTRODUCTION: High-power short-duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear. METHODS: In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W-HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s-vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters. RESULTS: STSF produced the highest maximum tissue temperature (Tmax ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t-T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip-to-thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t-T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with Tmax . CONCLUSION: This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on Tmax and/or t-T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Temperatura , Veia Cava Superior/cirurgia , Catéteres , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Temperatura Alta , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
Background: Ablation strategies and modalities for atrial fibrillation (AF) have transitioned over the past decade, but their impact on post-ablation medication and clinical outcomes remains to be fully investigated. Methods: We divided 682 patients who had undergone AF ablation in 2014-2019 (420 paroxysmal AFs [PAF], 262 persistent AFs [PerAF]) into three groups according to the period, that is, the 2014-2015 (n = 139), 2016-2017 (n = 244), and 2018-2019 groups (n = 299), respectively. Results: Persistent AF became more prevalent and the left atrial (LA) diameter larger over the 6 years. Extra-pulmonary vein (PV)-LA ablation was more frequently performed in the 2014-2015 group than in the 2016-2017 and 2018-2019 groups (41.1% vs. 9.1% and 8.1%; p < .001). The 2-year freedom rate from AF/atrial tachycardias for PAF was similar among the three groups (84.0% vs. 83.1% vs. 86.7%; p = .98) but lowest in the 2014-2015 group for PerAF (63.9% vs. 82.7% and 86.3%; p = .025) despite the highest post-ablation antiarrhythmic drug use. Cardiac tamponade was significantly decreased in the 2018-2019 group (3.6% vs. 2.0% vs. 0.33%; p = 0.021). There was no difference in the 2-year clinically relevant events among the three groups. Conclusion: Although ablation was performed in a more diseased LA and extra-PV-LA ablation was less frequent in recent years, the complication rate decreased, and AF recurrences for PAF remained unchanged, but that for PerAF decreased. Clinically relevant events remained unchanged over the recent 6 years, suggesting that the impact of the recent ablation modalities and strategies on remote clinically relevant events may be small during this study period.
RESUMO
INTRODUCTION: Neither the actual in vivo tissue temperatures reached with 90 W/4 s-very high-power short-duration (vHPSD) ablation for atrial fibrillation nor the safety and efficacy profile have been fully elucidated. METHODS: We conducted a porcine study (n = 15) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures close to a QDOT MICRO catheter, between during 90 W/4 s-vHPSD ablation during ablation index (AI: target 400)-guided 50 W-HPSD ablation, both targeting a contact force of 8-15 g. RESULTS: Maximum tissue temperature reached during 90 W/4 s-vHPSD ablation did not differ significantly from that during 50 W-HPSD ablation (49.2 ± 8.4°C vs. 50.0 ± 12.1°C; p = .69) and correlated inversely with distance between the catheter tip and the thermocouple, regardless of the power settings (r = -0.52 and r = -0.37). Lethal temperature (≥50°C) was best predicted at a catheter tip-to-thermocouple distance cut-point of 3.13 and 4.27 mm, respectively. All lesions produced by 90 W/4 s-vHPSD or 50 W-HPSD ablation were transmural. Although there was no difference in the esophageal injury rate (50% vs. 66%, p = .80), the thermal lesion was significantly shallower with 90 W/4 s-vHPSD ablation than with 50W-HPSD ablation (381.3 ± 127.3 vs. 820.0 ± 426.1 µm from the esophageal adventitia; p = .039). CONCLUSION: Actual tissue temperatures reached with 90 W/4 s-vHPSD ablation appear similar to those with AI-guided 50 W-HPSD ablation, with the distance between the catheter tip and target tissue being shorter for the former. Although both ablation settings may create transmural lesions in thin atrial tissues, any resulting esophageal thermal lesions appear shallower with 90 W/4 s-vHPSD ablation.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Suínos , Temperatura , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veia Cava Superior , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Esôfago/lesões , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Neither the actual in vivo tissue temperatures reached with lesion size index (LSI)-guided high-power short-duration (HPSD) ablation for atrial fibrillation nor the safety profile has been elucidated. METHODS: We conducted a porcine study (n = 7) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures reached during 50 W-HPSD ablation with those reached during standard (30 W) ablation, both targeting an LSI of 5.0 (5-15 g contact force). RESULTS: Tmax (maximum tissue temperature when the thermocouple was located ≤5 mm from the catheter tip) reached during HPSD ablation was modestly higher than that reached during standard ablation (58.0 ± 10.1°C vs. 53.6 ± 9.2°C; p = .14) and peak tissue temperature correlated inversely with the distance between the catheter tip and the thermocouple, regardless of the power settings (HPSD: r = -0.63; standard: r = -0.66). Lethal temperature (≥50°C) reached 6.3 ± 1.8 s and 16.9 ± 16.1 s after the start of HPSD and standard ablation, respectively (p = .002), and it was best predicted at a catheter tip-to-thermocouple distance cut point of 2.8 and 5.3 mm, respectively. All lesions produced by HPSD ablation and by standard ablation were transmural. There was no difference between HPSD ablation and standard ablation in the esophageal injury rate (70% vs. 75%, p = .81), but the maximum distance from the esophageal adventitia to the injury site tended to be shorter (0.94 ± 0.29 mm vs. 1.40 ± 0.57 mm, respectively; p = .09). CONCLUSIONS: Actual tissue temperatures reached with LSI-guided HPSD ablation appear to be modestly higher, with a shorter distance between the catheter tip and thermocouple achieving lethal temperature, than those reached with standard ablation. HPSD ablation lasting <6 s may help minimize lethal thermal injury to the esophagus lying at a close distance.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Temperatura , Veia Cava Superior , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Esôfago/lesões , Catéteres , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
Background: A subeustachian pouch (SEP) often hinders the completion of a cavotricuspid isthmus (CTI) ablation of typical atrial flutter (AFL) and sometimes causes steam-pops during a power-controlled ablation. We hypothesized that real-time bull's-eye monitoring of the catheter surface temperature might be useful to locate the SEP where the temperature can rise rapidly, and a temperature-controlled ablation might avoid steam pops. This study aimed to demonstrate this hypothesis. Methods: A temperature-controlled CTI ablation with a QDOT MICRO™ catheter (n = 10) and a conventional power-controlled CTI ablation (n = 10) were performed with an output power of 35 W. During the RF application, the bull's eye monitor for monitoring the catheter surface temperatures was assessed. A "red-bull sign" was defined as an entire red-colored bull's-eye monitor, indicating that the catheter-tip temperature of all 6 thermocouples rose rapidly over 47°C. Results: In a total of 115 lesions (12 ± 3 per patient), a "red-bull sign" was observed in 39 (33.9%) lesions where the RF output was reduced to 26 ± 8 W. All 39 "red-bull sign" lesions corresponded to the location of the SEP as delineated by ICE before the ablation. The red-bull sign accurately indicated the presence of a SEP with a sensitivity of 84.7% and specificity of 100%. Bidirectional block of the CTI was completed in all patients in either catheter group without any steam-pops. Conclusion: Real-time surface temperature monitoring and a red-bull sign might be useful to detect the SEP. A temperature-controlled CTI ablation with the QDOT MICRO catheter might be safe for avoiding steam pops.
RESUMO
The vascular occlusion test (VOT) with peripheral near-infrared spectroscopy (NIRS) is a non-invasive method to evaluate peripheral microcirculation. Statin therapy is widely used for patients with dyslipidaemia and contributes to reducing low-density lipoprotein cholesterol (LDL-C) levels and adverse cardiovascular events. However, it is not yet clear whether statin treatment improves peripheral microcirculation assessed by VOT with NIRS. In the present study, using VOT with NIRS, we evaluated the effect of statin therapy on peripheral microcirculation in patients with dyslipidaemia before and after statin therapy. METHODS: A total of six consecutive patients with dyslipidaemia who had not received statin therapy (6 males, mean age 71.8 ± 7.4 years) were enrolled. All patients were administered atorvastatin and their peripheral microcirculation assessed using VOT with NIRS (NIRO-200NX, Hamamatsu Photonics K.K., Japan) before and after statin therapy. The NIRS probe was attached to the right thenar eminence and brachial artery blood flow was blocked for 3 min at 50 mmHg above the resting systolic blood pressure. Maximum and minimum values of NIRS parameters after the VOT were used to determine concentration changes for total haemoglobin (ΔcHb), oxyhaemoglobin (ΔO2Hb), deoxyhaemoglobin (ΔHHb), and tissue oxygenation index (ΔTOI). RESULTS: During the follow-up period (mean 30.3 ± 6.5 days), LDL-C level decreased from 129.7 ± 26.3 to 67.5 ± 20.2 mg/dL (p-value = 0.031), ΔTOI increased from 24.0 ± 5.3 to 33.7 ± 6.3% (p-value = 0.023), and ΔO2Hb increased from 16.4 ± 5.3 to 20.0 ± 6.6 µmol/L (p-value = 0.007). ΔcHb and ΔHHb did not change significantly. CONCLUSION: ΔO2Hb and ΔTOI were significantly increased during the follow-up period. These findings suggest that ΔO2Hb and ΔTOI could assess the improvement of peripheral microcirculation by statin therapy. Compared to ΔTOI, ΔO2Hb seems to be a more useful parameter to evaluate peripheral microcirculation.
Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Doenças Vasculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Espectroscopia de Luz Próxima ao Infravermelho , Microcirculação , Atorvastatina/farmacologia , Atorvastatina/uso terapêutico , LDL-Colesterol , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Consumo de OxigênioRESUMO
Although a left atrial posterior wall isolation (LAPWI) in addition to a pulmonary vein isolation is a well-accepted option for persistent atrial fibrillation (AF), a complete isolation can be challenging. This study aimed to evaluate the performance of a modified ablation index (AI) (AI/bipolar voltage along the ablation line) for predicting a durable LAPWI. The study included 55 consecutive patients, aged 65 ± 11 years, who underwent an electroanatomic mapping-guided LAPWI of AF. The association between the gaps (first-pass LAPWI failure and/or acute LAPW reconnections), voltage amplitude along the roof and floor lines, and thickness of the LAPW was investigated. Gaps occurred in 22 patients (40%) and in 26 (8%) of the 330 line segments. Gaps were associated with a relatively high bipolar voltage (3.38 ± 1.83 vs. 1.70 ± 1.12 mV, P < 0.0001) and thick LA wall (2.52 ± 1.15 vs. 1.42 ± 0.44 mm, P < 0.0001). A modified AI ≤ 199 AU/mV, bipolar voltage ≥ 2.64 mV, wall thickness ≥ 2.04 mm, and roof ablation line ≥ 43.4 mm well predicted gaps (AUCs: 0.783, 0.787, 0.858, and 0.752, respectively). A high-voltage zone, thick LAPW, and long roof ablation line appeared to be determinants of gaps, and a modified AI ≥ 199 AU/mV along the ablation lines appeared to predict an acute durable LAPWI.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: Actual in vivo tissue temperatures and the safety profile during high-power short-duration (HPSD) ablation of atrial fibrillation have not been clarified. METHODS: We conducted an animal study in which, after a right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W-HPSD ablation and 30 W-standard ablation targeting an ablation index (AI) of 400 (5-15 g contact force). RESULTS: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = -0.71; standard: r = -0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip. CONCLUSIONS: Actual tissue temperatures reached with AI-guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento , Veia Cava Superior/cirurgiaRESUMO
Acute type B aortic dissection is sometimes complicated by acute respiratory failure requiring mechanical ventilation. Herein, we describe our experience in a rare acute type B aortic dissection-associated respiratory failure case culminating in acute respiratory distress syndrome. The patient was a 45-year-old man admitted with a complaint of sudden chest pain radiating to his back. On computed tomography, an acute type B aortic dissection was diagnosed. He had no dyspnea on admission, but his respiratory function subsequently deteriorated, and severe acute respiratory distress syndrome was diagnosed on Day 4. Venovenous extracorporeal membrane oxygenation with anticoagulation plus continuous renal replacement therapy for oliguria improved the oxygenation, and the patient was weaned from the extracorporeal membrane oxygenation on Day 8. This patient fully recovered without worsening the aortic dissection, using venovenous extracorporeal membrane oxygenation with anticoagulation plus a continuous renal replacement therapy.
Assuntos
Dissecção Aórtica , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Dissecção Aórtica/complicações , Dissecção Aórtica/terapia , Anticoagulantes , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapiaRESUMO
PURPOSE: Entrainment is a useful method for locating reentrant atrial tachycardia (AT) circuits, but alterations or termination of the AT can derail this process. We assessed whether resetting an upstream site of a neighboring electrode by a scanned extrastimulus at a downstream site (when the upstream tissue was refractory) could diagnose that site within the AT circuit. METHODS: The procedure was applied to 48 ATs with a cycle length (CL) of 238 ± 42 ms (26 common flutters, 8 perimitral flutters, 7 left atrial [LA] roof-dependent AT, 3 LA scar-related macroreentrant ATs, 2 pulmonary vein-gap reentry tachycardias, 1 right atrial scar-related macroreentrant AT, and 1 with an unidentified circuit). Entrainment and scanned extrastimulation were attempted at the cavotricuspid isthmus, LA roof, and mitral isthmus and/or critical AT isthmus. RESULTS: Within the circuit, the post-pacing interval minus the ATCL after entrainment was < 30 ms for all ATs and resetting of the AT cycle by ≥ 5 ms occurred in 94% of the ATs. No ATs were reset by extrastimulation outside the circuit. The positive predictive value of both maneuvers for locating the circuit was 100%, and the negative predictive value of the extrastimulation was similar to that of entrainment (96% vs. 100%, P = 0.25). The incidence of an AT alteration was lower with extrastimulation than with entrainment (1% vs. 9%, P = 0.01). For ATs with a CL < 210 ms, extrastimulation yielded a good diagnostic performance without any AT alterations. CONCLUSION: AT resetting by a scanned extrastimulus is diagnostic and avoids AT alterations.
Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Catéteres , Átrios do Coração/cirurgia , Humanos , Taquicardia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgiaRESUMO
BACKGROUND: Although low-voltage zones (LVZs) in the left atrium (LA) are considered arrhythmogenic substrates in some patients with atrial fibrillation (AF), the pathophysiologic factors responsible for LVZ formations remain unclear. OBJECTIVE: To elucidate the anatomical relationship between the LA and ascending aorta responsible for anterior LA wall remodeling. METHODS: We assessed the relationship between existence of LVZs on the anterior LA wall and the three-dimensional computed tomography image measurements in 102 patients who underwent AF ablation. RESULTS: Twenty-nine patients (28%) had LVZs grearer than 1.0 cm2 on the LA wall in the LA-ascending aorta contact area (LVZ group); no LVZs were seen in the other 73 patients (no-LVZ group). The LVZ group (vs. no-LVZ group) had a smaller aorta-LA angle (21.0 ± 7.7° vs. 24.9 ± 7.1°, p = .015), greater aorta-left-ventricle (LV) angle (131.3 ± 8.8° vs. 126.0 ± 7.9°; p = .005), greater diameter of the noncoronary cusp (NCC; 20.4 ± 2.2 vs. 19.3 ± 2.5 mm; p = .036), thinner LA wall-thickness adjacent to the NCC (2.3 ± 0.7 vs. 2.8 ± 0.8 mm; p = .006), and greater cardiothoracic ratio (percentage of the area in the thoracic area, 40.1 ± 7.1% vs. 35.4 ± 5.7%, p < .001). The aorta-LA angle correlated positively with the patients' body mass index (BMI), and the aorta-LV angle correlated negatively with the body weight and BMI. CONCLUSION: Deviation of the ascending aorta's course and distention of the NCC appear to be related to the development of LA anterior wall LVZs in the LA-ascending aorta contact area. Mechanical pressure exerted by extracardiac structures on the LA along with the limited thoracic space may contribute to the development of LVZs associated with AF.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Aorta/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , HumanosRESUMO
INTRODUCTION: Preferential pathway conduction is mostly detected as fractionated presystolic-potentials preceding the QRS during premature ventricular contractions (PVCs) and late-potentials during sinus rhythm (SR), but the electrophysiologic mechanisms and significance of these potentials have not been fully clarified. We describe a PVC case series in which the preferential pathway conduction was three-dimensionally visualized. METHODS: Five PVCs (two from the left coronary cusp, two from the commissure of the left and right coronary cusps, and one from the pulmonary artery) in four patients for which a fractionated presystolic-potential during the PVCs and late-potential during SR were recorded at the successful ablation site were reviewed, and three-dimensional coherent activation maps with the conduction velocity vector during the PVCs and SR were reconstructed. RESULTS: At the successful ablation site, an "M"-shaped discrete presystolic-potential and "W"-shaped discrete late-potential were recorded in all patients. The configuration of the inverted electrogram of the presystolic-potential was similar to that of the electrogram exhibiting the late-potential. We created coherent activation maps annotating the onset of the presystolic-potentials during the PVCs and offset of the late-potentials during SR, which suggested bidirectional conduction of the preferential pathway connecting the PVC origin to the myocardium. CONCLUSION: Detailed activation mapping of these PVCs is consistent with the presence of fibers along the aortic or pulmonic valve ring that have preferential directions for conduction. PVCs produce a presystolic-potential. In SR, the fiber is activated late and from the opposite direction, producing an inverted potential inscribed on the end of the QRS.